Pract Radiat Oncol ; 12(1): e49-e55, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34464743

RESUMO

During the last decade, radiation oncology departments have integrated magnetic resonance imaging (MRI) equipment, procedures, and expertise into their practices. MRI safety is an important consideration because a large percentage of patients receiving radiation therapy have histories of multiple surgeries and implanted devices. However, MRI safety guidelines and workflows were traditionally designed for radiology departments. This report presents an MR safety program designed for a radiation oncology department to address its specific needs.


Assuntos
Radioterapia (Especialidade) , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
3.
J Appl Clin Med Phys ; 21(10): 241-247, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32931649

RESUMO

To present a tumor motion control system during free breathing using direct tumor visual feedback to patients in 0.35 T magnetic resonance-guided radiotherapy (MRgRT). We present direct tumor visualization to patients by projecting real-time cine MR images on an MR-compatible display system inside a 0.35 T MRgRT bore. The direct tumor visualization included anatomical images with a target contour and an auto-segmented gating contour. In addition, a beam-status sign was added for patient guidance. The feasibility was investigated with a six-patient clinical evaluation of the system in terms of tumor motion range and beam-on time. Seven patients without visual guidance were used for comparison. Positions of the tumor and the auto-segmented gating contour from the cine MR images were used in probability analysis to evaluate tumor motion control. In addition, beam-on time was recorded to assess the efficacy of the visual feedback system. The direct tumor visualization system was developed and implemented in our clinic. The target contour extended 3 mm outside of the gating contour for 33.6 ± 24.9% of the time without visual guidance, and 37.2 ± 26.4% of the time with visual guidance. The average maximum motion outside of the gating contour was 14.4 ± 11.1 mm without and 13.0 ± 7.9 mm with visual guidance. Beam-on time as a percentage was 43.9 ± 15.3% without visual guidance, and 48.0 ± 21.2% with visual guidance, but was not significantly different (P = 0.34). We demonstrated the clinical feasibility and potential benefits of presenting direct tumor visual feedback to patients in MRgRT. The visual feedback allows patients to visualize and attempt to minimize tumor motion in free breathing. The proposed system and associated clinical workflow can be easily adapted for any type of MRgRT.


Assuntos
Neoplasias , Radioterapia Guiada por Imagem , Retroalimentação Sensorial , Humanos , Imageamento por Ressonância Magnética , Neoplasias/radioterapia , Respiração
4.
J Appl Clin Med Phys ; 20(10): 53-66, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31541542

RESUMO

PURPOSE: To present lessons learned from magnetic resonance imaging (MRI) quality control (QC) tests for low-field MRI-guided radiation therapy (MR-IGRT) systems. METHODS: MRI QC programs were established for low-field MRI-60 Co and MRI-Linac systems. A retrospective analysis of MRI subsystem performance covered system commissioning, operations, maintenance, and quality control. Performance issues were classified into three groups: (a) Image noise and artifact; (b) Magnetic field homogeneity and linearity; and (c) System reliability and stability. RESULTS: Image noise and artifacts were attributed to room noise sources, unsatisfactory system cabling, and broken RF receiver coils. Gantry angle-dependent magnetic field inhomogeneities were more prominent on the MRI-Linac due to the high volume of steel shielding in the gantry. B0 inhomogeneities measured in a 24-cm spherical phantom were <5 ppm for both MR-IGRT systems after using MRI gradient offset (MRI-GO) compensation on the MRI-Linac. However, significant signal dephasing occurred on the MRI-Linac while the gantry was rotating. Spatial integrity measurements were sensitive to gradient calibration and vulnerable to shimming. The most common causes of MR-IGRT system interruptions were software disconnects between the MRI and radiation therapy delivery subsystems caused by patient table, gantry, and multi-leaf collimator (MLC) faults. The standard deviation (SD) of the receiver coil signal-to-noise ratio was 1.83 for the MRI-60 Co and 1.53 for the MRI-Linac. The SD of the deviation from the mean for the Larmor frequency was 1.41 ppm for the MRI-60 Co and 1.54 ppm for the MRI-Linac. The SD of the deviation from the mean for the transmitter reference amplitude was 0.90% for the MRI-60 Co and 1.68% for the MRI-Linac. High SDs in image stability data corresponded to reports of spike noise. CONCLUSIONS: There are significant technological challenges associated with implementing and maintaining MR-IGRT systems. Most of the performance issues were identified and resolved during commissioning.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Controle de Qualidade , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Artefatos , Radioisótopos de Cobalto , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Software
5.
Pract Radiat Oncol ; 9(4): 274-279, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30790716

RESUMO

Magnetic resonance imaging (MRI) guided radiation therapy is reported for the first time in a patient with an implantable cardioverter defibrillator (ICD) and cardiac fibroma in the left ventricle. Stereotactic body radiation therapy was delivered in 5 fractions at a dose of 700 cGy/fraction using a 0.35 T MRI-linear accelerator with real-time tumor tracking and beam gating. The average treatment time per fraction was 12.13 minutes, including gating dead time and gantry rotation, and the average duty cycle was 56.8%. Lessons learned included the need for MRI safety workflows that address the ICD and are tailored to the radiation oncology environment, selection of a suitable tracking target to ensure satisfactory duty cycle, and the presence of null band artifacts within the tracking target caused by ferrous components in the ICD.


Assuntos
Desfibriladores Implantáveis/normas , Coração/efeitos da radiação , Imageamento por Ressonância Magnética/métodos , Humanos , Masculino , Pessoa de Meia-Idade