Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Methods Enzymol ; 688: 195-222, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37748827

RESUMO

This chapter discusses the use of diffraction simulators to improve experimental outcomes in macromolecular crystallography, in particular for future experiments aimed at diffuse scattering. Consequential decisions for upcoming data collection include the selection of either a synchrotron or free electron laser X-ray source, rotation geometry or serial crystallography, and fiber-coupled area detector technology vs. pixel-array detectors. The hope is that simulators will provide insights to make these choices with greater confidence. Simulation software, especially those packages focused on physics-based calculation of the diffraction, can help to predict the location, size, shape, and profile of Bragg spots and diffuse patterns in terms of an underlying physical model, including assumptions about the crystal's mosaic structure, and therefore can point to potential issues with data analysis in the early planning stages. Also, once the data are collected, simulation may offer a pathway to improve the measurement of diffraction, especially with weak data, and might help to treat problematic cases such as overlapping patterns.


Assuntos
Análise de Dados , Software , Simulação por Computador , Cristalografia , Substâncias Macromoleculares
2.
J Synchrotron Radiat ; 30(Pt 2): 390-399, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36891852

RESUMO

Full-field X-ray nanoimaging is a widely used tool in a broad range of scientific areas. In particular, for low-absorbing biological or medical samples, phase contrast methods have to be considered. Three well established phase contrast methods at the nanoscale are transmission X-ray microscopy with Zernike phase contrast, near-field holography and near-field ptychography. The high spatial resolution, however, often comes with the drawback of a lower signal-to-noise ratio and significantly longer scan times, compared with microimaging. In order to tackle these challenges a single-photon-counting detector has been implemented at the nanoimaging endstation of the beamline P05 at PETRA III (DESY, Hamburg) operated by Helmholtz-Zentrum Hereon. Thanks to the long sample-to-detector distance available, spatial resolutions of below 100 nm were reached in all three presented nanoimaging techniques. This work shows that a single-photon-counting detector in combination with a long sample-to-detector distance allows one to increase the time resolution for in situ nanoimaging, while keeping a high signal-to-noise level.

3.
Opt Express ; 30(19): 33652-33663, 2022 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-36242395

RESUMO

X-ray ptychography is a cutting edge imaging technique providing ultra-high spatial resolutions. In ptychography, phase retrieval, i.e., the recovery of a complex valued signal from intensity-only measurements, is enabled by exploiting a redundancy of information contained in diffraction patterns measured with overlapping illuminations. For samples that are considerably larger than the probe we show that during the iteration the bulk information has to propagate from the sample edges to the center. This constitutes an inherent limitation of reconstruction speed for algorithms that use a flat initialization. Here, we experimentally demonstrate that a considerable improvement of computational speed can be achieved by utilizing a low resolution sample wavefront retrieved from measured diffraction patterns as object initialization. In addition, we show that this approach avoids phase artifacts associated with large phase gradients and may alleviate the requirements on phase structure within the probe. Object initialization is computationally fast, potentially beneficial for bulky sample and compatible with flat samples. Therefore, the presented approach is readily adaptable with established ptychographic reconstruction algorithms implying a wide spread use.

4.
Nat Commun ; 13(1): 4971, 2022 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-36038564

RESUMO

Understanding morphological changes of nanoparticles in solution is essential to tailor the functionality of devices used in energy generation and storage. However, we lack experimental methods that can visualize these processes in solution, or in electrolyte, and provide three-dimensional information. Here, we show how X-ray ptychography enables in situ nano-imaging of the formation and hollowing of nanoparticles in solution at 155 °C. We simultaneously image the growth of about 100 nanocubes with a spatial resolution of 66 nm. The quantitative phase images give access to the third dimension, allowing to additionally study particle thickness. We reveal that the substrate hinders their out-of-plane growth, thus the nanocubes are in fact nanocuboids. Moreover, we observe that the reduction of Cu2O to Cu triggers the hollowing of the nanocuboids. We critically assess the interaction of X-rays with the liquid sample. Our method enables detailed in-solution imaging for a wide range of reaction conditions.

5.
Sci Rep ; 12(1): 6203, 2022 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-35418587

RESUMO

Imaging large areas of a sample non-destructively and with high resolution is of great interest for both science and industry. For scanning coherent X-ray diffraction microscopy, i. e., ptychography, the achievable scan area at a given spatial resolution is limited by the coherent photon flux of modern X-ray sources. Multibeam X-ray ptychography can improve the scanning speed by scanning the sample with several parallel mutually incoherent beams, e. g., generated by illuminating multiple focusing optics in parallel by a partially coherent beam. The main difficulty with this scheme is the robust separation of the superimposed signals from the different beams, especially when the beams and the illuminated sample areas are quite similar. We overcome this difficulty by encoding each of the probing beams with its own X-ray phase plate. This helps the algorithm to robustly reconstruct the multibeam data. We compare the coded multibeam scans to uncoded multibeam and single beam scans, demonstrating the enhanced performance on a microchip sample with regular and repeating structures.

6.
Opt Express ; 29(9): 14025-14032, 2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-33985128

RESUMO

We report on the manufacturing and testing of the first nanofocusing refractive lenses made of single-crystal silicon carbide. We introduce the fabrication process based on lithography, followed by deep isotropic etching. The lenses were characterized at the energy of 12 keV at the beamline P06 of the synchrotron radiation source PETRA III. A focal spot of 186 nm×275 nm has been achieved with a lens working distance of 29 mm.

7.
J Synchrotron Radiat ; 28(Pt 3): 1030, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33950011

RESUMO

A correction in the paper by Seiboth et al. [(2018). J. Synchrotron Rad. 25, 108-115] is made.

8.
Sci Rep ; 11(1): 1500, 2021 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-33452343

RESUMO

Ptychographic X-ray microscopy is an ideal tool to observe chemical processes under in situ conditions. Chemical reactors, however, are often thicker than the depth of field, limiting the lateral spatial resolution in projection images. To overcome this limit and reach higher lateral spatial resolution, wave propagation within the sample environment has to be taken into account. Here, we demonstrate this effect recording a ptychographic projection of copper(I) oxide nanocubes grown on two sides of a polyimide foil. Reconstructing the nanocubes using the conventional ptychographic model shows the limitation in the achieved resolution due to the thickness of the foil. Whereas, utilizing a multi-slice approach unambiguously separates two sharper reconstructions of nanocubes on both sides of the foil. Moreover, we illustrate how ptychographic multi-slice reconstructions are crucial for high-quality imaging of chemical processes by ex situ studying copper(I) oxide nanocubes grown on the walls of a liquid cell.

9.
J Synchrotron Radiat ; 27(Pt 5): 1121-1130, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32876586

RESUMO

Modern subtractive and additive manufacturing techniques present new avenues for X-ray optics with complex shapes and patterns. Refractive phase plates acting as glasses for X-ray optics have been fabricated, and spherical aberration in refractive X-ray lenses made from beryllium has been successfully corrected. A diamond phase plate made by femtosecond laser ablation was found to improve the Strehl ratio of a lens stack with a numerical aperture (NA) of 0.88 × 10-3 at 8.2 keV from 0.1 to 0.7. A polymer phase plate made by additive printing achieved an increase in the Strehl ratio of a lens stack at 35 keV with NA of 0.18 × 10-3 from 0.15 to 0.89, demonstrating diffraction-limited nanofocusing at high X-ray energies.

10.
J Appl Crystallogr ; 53(Pt 4): 957-971, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32788903

RESUMO

Ptychographic X-ray imaging at the highest spatial resolution requires an optimal experimental environment, providing a high coherent flux, excellent mechanical stability and a low background in the measured data. This requires, for example, a stable performance of all optical components along the entire beam path, high temperature stability, a robust sample and optics tracking system, and a scatter-free environment. This contribution summarizes the efforts along these lines to transform the nanoprobe station on beamline P06 (PETRA III) into the ptychographic nano-analytical microscope (PtyNAMi).

11.
Opt Lett ; 44(18): 4622-4625, 2019 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-31517948

RESUMO

In this Letter, we report on the creation of hard x-ray beams carrying orbital angular momentum of topological charge -ℏ and -3ℏ at a photon energy of 8.2 keV via spiral phase plates made out of fused silica by ultrashort-pulsed laser ablation. The phase plates feature a smooth phase ramp with a 0.5 µm nominal step height and a surface roughness of 0.5 µm. The measured vortex beams show submicrometer-sized donut rings and agree well with numerical modeling. Fused silica phase plates are potentially suited to manipulate the electromagnetic field in highly intense x-ray beams at x-ray free-electron laser sources.

12.
J Synchrotron Radiat ; 26(Pt 5): 1769-1781, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31490169

RESUMO

Two in situ `nanoreactors' for high-resolution imaging of catalysts have been designed and applied at the hard X-ray nanoprobe endstation at beamline P06 of the PETRA III synchrotron radiation source. The reactors house samples supported on commercial MEMS chips, and were applied for complementary hard X-ray ptychography (23 nm spatial resolution) and transmission electron microscopy, with additional X-ray fluorescence measurements. The reactors allow pressures of 100 kPa and temperatures of up to 1573 K, offering a wide range of conditions relevant for catalysis. Ptychographic tomography was demonstrated at limited tilting angles of at least ±35° within the reactors and ±65° on the naked sample holders. Two case studies were selected to demonstrate the functionality of the reactors: (i) annealing of hierarchical nanoporous gold up to 923 K under inert He environment and (ii) acquisition of a ptychographic projection series at ±35° of a hierarchically structured macroporous zeolite sample under ambient conditions. The reactors are shown to be a flexible and modular platform for in situ studies in catalysis and materials science which may be adapted for a range of sample and experiment types, opening new characterization pathways in correlative multimodal in situ analysis of functional materials at work. The cells will presently be made available for all interested users of beamline P06 at PETRA III.


Assuntos
Catálise , Ciência dos Materiais/instrumentação , Microscopia Eletrônica , Elétrons , Desenho de Equipamento , Ouro/química , Síncrotrons , Temperatura , Raios X , Zeolitas/química
13.
J Synchrotron Radiat ; 25(Pt 1): 108-115, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29271759

RESUMO

Wavefront errors of rotationally parabolic refractive X-ray lenses made of beryllium (Be CRLs) have been recovered for various lens sets and X-ray beam configurations. Due to manufacturing via an embossing process, aberrations of individual lenses within the investigated ensemble are very similar. By deriving a mean single-lens deformation for the ensemble, aberrations of any arbitrary lens stack can be predicted from the ensemble with \bar{\sigma} = 0.034λ. Using these findings the expected focusing performance of current Be CRLs are modeled for relevant X-ray energies and bandwidths and it is shown that a correction of aberrations can be realised without prior lens characterization but simply based on the derived lens deformation. The performance of aberration-corrected Be CRLs is discussed and the applicability of aberration-correction demonstrated over wide X-ray energy ranges.

14.
Nat Commun ; 8: 14623, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28248317

RESUMO

Due to their short wavelength, X-rays can in principle be focused down to a few nanometres and below. At the same time, it is this short wavelength that puts stringent requirements on X-ray optics and their metrology. Both are limited by today's technology. In this work, we present accurate at wavelength measurements of residual aberrations of a refractive X-ray lens using ptychography to manufacture a corrective phase plate. Together with the fitted phase plate the optics shows diffraction-limited performance, generating a nearly Gaussian beam profile with a Strehl ratio above 0.8. This scheme can be applied to any other focusing optics, thus solving the X-ray optical problem at synchrotron radiation sources and X-ray free-electron lasers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...