Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 67(20)2022 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-36170871

RESUMO

Objective.GPU-oriented Monte Carlo dose (GPUMCD) is a fast dose calculation algorithm used for treatment planning on the Unity MR-linac. Treatments for the MR-linac must be calculated quickly and accurately, and must account for two important MR-linac aspects: off-axis positions and angular transmission through the cryostat, couch and MR-coils. Therefore, the aim of this research is to quantify the system-related errors for GPUMCD calculations over the range of clinically-relevant field configurations and gantry angles.Approach.Dose profiles (crossline, inline and PDD) were measured and calculated for varying field sizes, off-axis positions and depths. Eleven different (off-axis) positions were included. The angular transmission was investigated by measuring and calculating the transmission for multiple angles, taking the cryostat, couch and coils into account.Main results.Differences between absolute point doses were found to be within 1.7% for field sizes 2 × 2 cm2and larger. The relative dose profiles in the crossline, inline and PDD direction illustrated maximum mean dose differences of 0.9pp, 0.8pp and 0.7pp ofDmaxin the central region for field sizes 2 × 2 cm2and larger. The 1 × 1 cm2field size showed larger dosimetric errors for absolute point doses and relative dose profiles. The maximum mean DTA in the penumbra was 0.7 mm. The mean difference in angular transmission ranged from -0.33% ± 0.60% to 0.27% ± 0.91% using three treatment machines. Additionally, 77.1%-93.7% of the datapoints remained within 1% transmission difference. The largest transmission differences were present at the edges of the table.Significance.This research showed that the GPUMCD algorithm provides reliable dose calculations with a low uncertainty for field sizes 2 × 2 cm2and larger, focusing on off-axis fields and angular transmission.


Assuntos
Aceleradores de Partículas , Radiometria , Algoritmos , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos
2.
Med Phys ; 46(8): 3739-3745, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31131902

RESUMO

PURPOSE: Reference dosimetry in a strong magnetic field is made more complex due to (a) the change in dose deposition and (b) the change in sensitivity of the detector. Potentially it is also influenced by thin air layers, interfaces between media, relative orientations of field, chamber and radiation, and minor variations in ion chamber stem or electrode construction. The PTW30013 and IBA FC65-G detectors are waterproof Farmer-type ion chambers that are suitable for reference dosimetry. The magnetic field correction factors have previously been determined for these chamber types. The aim of this study was to assess the chamber-to-chamber variation and determine whether generic chamber type-specific magnetic field correction factors can be applied for each of the PTW30013 and FC65-G type ion chambers when they are oriented anti-parallel (ǁ) to, or perpendicular (⊥) to, the magnetic field. METHODS: The experiment was conducted with 12 PTW30013 and 13 FC65-G chambers. The magnetic field correction factors were measured using a practical method. In this study each chamber was cross-calibrated against the local standard chamber twice; with and without magnetic field. Measurements with 1.5 T magnetic field were performed with the 7 MV FFF beam of the MRI-linac. Measurements without magnetic field (0 T) were performed with the 6 MV conventional beam of an Elekta Agility linac. A prototype MR-compatible PTW MP1 phantom was used along with a prototype holder that facilitated measurements with the chamber aligned 90° counter-clockwise (⊥) and 180° (ǁ) to the direction of the magnetic field. A monitor chamber was also mounted on the holder and all measurements were normalized so that the effect of variations in the output of each linac was minimized. Measurements with the local standard chamber were repeated during the experiment to quantify the experimental uncertainty. Recombination was measured in the 6 MV beam. Beam quality correction factors were applied. Differences in recombination and beam quality between beams are constant within each chamber type. By comparing the results for the two cross calibrations the magnetic field correction factors can be determined for each chamber, and the variation within the chamber-type determined. RESULTS: The magnetic field correction factors within both PTW30013 and FC65-G chamber-types were found to be very consistent, with observed standard deviations for the PTW30013 of 0.19% (ǁ) and 0.13% (⊥), and for the FC65-G of 0.15% (ǁ) and 0.17% (⊥). These variations are comparable with the standard uncertainty (k = 1) of 0.24%. CONCLUSION: The consistency of the results for the PTW30013 and FC65-G chambers implies that it is not necessary to derive a new factor for every new PTW30013 or FC65-G chamber. Values for each chamber-type (with careful attention to beam energy, magnetic field strength and beam-field-chamber orientations) can be applied from the literature.


Assuntos
Campos Magnéticos , Radiometria/instrumentação , Calibragem , Aceleradores de Partículas , Imagens de Fantasmas
3.
Phys Med Biol ; 63(12): 125008, 2018 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-29786612

RESUMO

A generic formalism is proposed for reference dosimetry in the presence of a magnetic field. Besides the regular correction factors from the conventional reference dosimetry formalisms, two factors are used to take into account magnetic field effects: (1) a dose conversion factor to correct for the change in local dose distribution and (2) a correction of the reading of the dosimeter used for the reference dosimetry measurements. The formalism was applied to the Elekta MRI-Linac, for which the 1.5 T magnetic field is orthogonal to the 7 MV photon beam. For this setup at reference conditions it was shown that the dose decreases with increasing magnetic field strength. The reduction in local dose for a 1.5 T transverse field, compared to no field is 0.51% ± 0.03% at the reference point of 10 cm depth. The effect of the magnetic field on the reading of the dosimeter was measured for two waterproof ionization chambers types (PTW 30013 and IBA FC65-G) before and after multiple ramp-up and ramp-downs of the magnetic field. The chambers were aligned perpendicular and parallel to the magnetic field. The corrections of the readings of the perpendicularly aligned chambers were 0.967 ± 0.002 and 0.957 ± 0.002 for respectively the PTW and IBA ionization chambers. In the parallel alignment the corrections were small; 0.997 ± 0.001 and 1.002 ± 0.003 for the PTW and IBA chamber respectively. The change in reading due to the magnetic field can be measured by individual departments. The proposed formalism can be used to determine the correction factors needed to establish the absorbed dose in a magnetic field. It requires Monte Carlo simulations of the local dose and measurements of the response of the dosimeter. The formalism was successfully implemented for the MRI-Linac and is applicable for other field strengths and geometries.


Assuntos
Campos Magnéticos , Fótons , Dosímetros de Radiação/normas , Humanos , Método de Monte Carlo , Radiometria/normas , Padrões de Referência
4.
Phys Med Biol ; 63(8): 085015, 2018 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-29521280

RESUMO

As a prerequisite for clinical treatments it was necessary to characterize the Elekta 1.5 T MRI-linac 7 MV FFF radiation beam. Following acceptance testing, beam characterization data were acquired with Semiflex 3D (PTW 31021), microDiamond (PTW 60019), and Farmer-type (PTW 30013 and IBA FC65-G) detectors in an Elekta 3D scanning water phantom and a PTW 1D water phantom. EBT3 Gafchromic film and ion chamber measurements in a buildup cap were also used. Special consideration was given to scan offsets, detector effective points of measurement and avoiding air gaps. Machine performance has been verified and the system satisfied the relevant beam requirements of IEC60976. Beam data were acquired for field sizes between 1 × 1 and 57 × 22 cm2. New techniques were developed to measure percentage depth dose (PDD) curves including the electron return effect at beam exit, which exhibits an electron-type practical range of 1.2 ± 0.1 cm. The Lorentz force acting on the secondary charged particles creates an asymmetry in the crossline profiles with an average shift of +0.24 cm. For a 10 × 10 cm2 beam, scatter from the cryostat contributes 1% of the dose at isocentre. This affects the relative output factors, scatter factors and beam profiles, both in-field and out-of-field. The average 20%-80% penumbral width measured for small fields with a microDiamond detector at 10 cm depth is 0.50 cm. MRI-linac penumbral widths are very similar to that of the Elekta Agility linac MLC, as is the near-surface dose PDD(0.2 cm) = 57%. The entrance surface dose is ∼36% of Dmax. Cryostat transmission is quantified for inclusion within the treatment planning system. As a result, the 1.5 T MRI-linac 7 MV FFF beam has been characterised for the first time and is suitable for clinical use. This was a key step towards the first clinical treatments with the MRI-linac, which were delivered at University Medical Center Utrecht in May 2017 (Raaymakers et al 2017 Phys. Med. Biol. 62 L41-50).


Assuntos
Imageamento por Ressonância Magnética/métodos , Aceleradores de Partículas , Imagens de Fantasmas , Radiometria/métodos , Elétrons , Humanos , Campos Magnéticos , Posicionamento do Paciente , Água
5.
Phys Med Biol ; 63(5): 05NT04, 2018 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-29239857

RESUMO

Accurate small-field dosimetry is critical for a magnetic resonance linac (MRI-linac). The PTW 60019 microDiamond is close to an ideal detector for small field dosimetry due to its small physical size, high signal-to-noise ratio and approximate water equivalence. It is important to fully characterise the performance of the detector in a 1.5 T magnetic field prior to its use for MRI-linac commissioning and quality assurance. Standard techniques of detector testing have been implemented, or adapted where necessary to suit the capabilities of the MRI-linac. Detector warmup, constancy, dose linearity, dose rate linearity, field size dependence and leakage were within tolerance. Measurements with the detector were consistent with ion chamber measurements for medium sized fields. The effective point of measurement of the detector when used within a 1.5 T magnetic field was determined to be 0.80 ± 0.23 mm below the top surface of the device, consistent with the existing vendor recommendation and alignment mark at 1.0 mm. The angular dependence was assessed. Variations of up to 9.7% were observed, which are significantly greater than in a 0 T environment. Within the expected range of use, the maximum effect is approximately 0.6% which is within tolerance. However for large beams within a magnetic field, the divergence and consequent variation in angle of photon incidence means that the microDiamond would not be ideal for characterising the profiles and it would not be suitable for determining large-field beam parameters such as symmetry. It would also require a correction factor prior to use for patient-specific QA measurements where radiation is delivered from different gantry angles. The results of this study demonstrate that the PTW 60019 microDiamond detector is suitable for measuring small radiation fields within a 1.5 T magnetic field and thus is suitable for use in MRI-linac commissioning and quality assurance.


Assuntos
Imageamento por Ressonância Magnética/métodos , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Radiometria/instrumentação , Humanos , Campos Magnéticos , Fótons , Radiometria/métodos , Água
6.
Phys Med Biol ; 63(2): 02NT02, 2018 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-29176067

RESUMO

To perform patient plan quality assurance (QA) on a newly installed MR-linac (MRL) it is necessary to have an MR-compatible QA device. An MR compatible device (MR-Delta4) has been developed together with Scandidos AB (Uppsala, Sweden). The basic characteristics of the detector response, such as short-term reproducibility, dose linearity, field size dependency, dose rate dependency, dose-per-pulse dependency and angular dependency, were investigated for the clinical Delta4-PT as well as for the MR compatible version. All tests were performed with both devices on a conventional linac and the MR compatible device was tested on the MRL as well. No statistically significant differences were found in the short-term reproducibility (<0.1%), dose linearity (⩽0.5%), field size dependency (<2.0% for field sizes larger than 5 × 5 cm2), dose rate dependency (<1.0%) or angular dependency for any phantom/linac combination. The dose-per-pulse dependency (<0.8%) was found to be significantly different between the two devices. This difference can be explained by the fact that the diodes in the clinical Delta4-PT were irradiated with a much larger dose than the MR-Delta4-PT ones. The absolute difference between the devices (<0.5%) was found to be small, so no clinical impact is expected. For both devices, the results were consistent with the characteristics of the Delta4-PT device reported in the literature (Bedford et al 2009 Phys. Med. Biol. 54 N167-76; Sadagopan et al 2009 J. Appl. Clin. Med. Phys. 10 2928). We found that the characteristics of the MR compatible Delta4 phantom were found to be comparable to the clinically used one. Also, the found characteristics do not differ from the previously reported characteristics of the commercially available non-MR compatible Delta4-PT phantom. Therefore, the MR compatible Delta4 prototype was found to be safe and effective for use in the 1.5 tesla magnetic field of the Elekta MR-linac.


Assuntos
Imageamento por Ressonância Magnética/métodos , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Processamento de Imagem Assistida por Computador , Radiometria/métodos
7.
Phys Med Biol ; 62(23): L41-L50, 2017 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-29135471

RESUMO

The integration of 1.5 T MRI functionality with a radiotherapy linear accelerator (linac) has been pursued since 1999 by the UMC Utrecht in close collaboration with Elekta and Philips. The idea behind this integrated device is to offer unrivalled, online and real-time, soft-tissue visualization of the tumour and the surroundings for more precise radiation delivery. The proof of concept of this device was given in 2009 by demonstrating simultaneous irradiation and MR imaging on phantoms, since then the device has been further developed and commercialized by Elekta. The aim of this work is to demonstrate the clinical feasibility of online, high-precision, high-field MRI guidance of radiotherapy using the first clinical prototype MRI-Linac. Four patients with lumbar spine bone metastases were treated with a 3 or 5 beam step-and-shoot IMRT plan. The IMRT plan was created while the patient was on the treatment table and based on the online 1.5 T MR images; pre-treatment CT was deformably registered to the online MRI to obtain Hounsfield values. Bone metastases were chosen as the first site as these tumors can be clearly visualized on MRI and the surrounding spine bone can be detected on the integrated portal imager. This way the portal images served as an independent verification of the MRI based guidance to quantify the geometric precision of radiation delivery. Dosimetric accuracy was assessed post-treatment from phantom measurements with an ionization chamber and film. Absolute doses were found to be highly accurate, with deviations ranging from 0.0% to 1.7% in the isocenter. The geometrical, MRI based targeting as confirmed using portal images was better than 0.5 mm, ranging from 0.2 mm to 0.4 mm. In conclusion, high precision, high-field, 1.5 T MRI guided radiotherapy is clinically feasible.


Assuntos
Neoplasias Ósseas/radioterapia , Região Lombossacral/efeitos da radiação , Imageamento por Ressonância Magnética/instrumentação , Aceleradores de Partículas/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Neoplasias da Coluna Vertebral/radioterapia , Idoso , Neoplasias Ósseas/secundário , Humanos , Pessoa de Meia-Idade , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Neoplasias da Coluna Vertebral/patologia
8.
Med Phys ; 43(7): 3961, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27370114

RESUMO

PURPOSE: A protocol for reference dosimetry for the MR-linac is under development. The 1.5 T magnetic field changes the mean path length of electrons in an air-filled ionization chamber but has little effect on the electron trajectories in a surrounding phantom. It is therefore necessary to correct the response of an ionization chamber for the influence of the magnetic field. Solid phantoms are used for dosimetry measurements on the MR-linac, but air is present between the chamber wall and phantom insert. This study aimed to determine if this air influences the ion chamber measurements on the MR-linac. The absolute response of the chamber and reproducibility of dosimetry measurements were assessed on an MR-linac in solid and water phantoms. The sensitivity of the chamber response to the distribution of air around the chamber was also investigated. METHODS: Measurements were performed on an MR-linac and replicated on a conventional linac for five chambers. The response of three waterproof chambers was measured with air and with water between the chamber and the insert to measure the influence of the air volume on absolute chamber response. The distribution of air around the chamber was varied indirectly by rotating each chamber about the longitudinal chamber axis in a solid phantom and a water phantom (waterproof chambers only) and measuring the angular dependence of the chamber response, and varied directly by displacing the chamber in the phantom insert using a paper shim positioned at different orientations between the chamber casing and the insert. RESULTS: The responses of the three waterproof chambers measured on the MR-linac were 0.7%-1.2% higher with water than air in the chamber insert. The responses of the chambers on the conventional linac changed by less than 0.3% when air in the insert was replaced with water. The angular dependence of the chambers ranged from 0.6% to 1.9% in the solid phantom on the MR-linac but was less than 0.5% in water on the MR-linac and less than 0.3% in the solid phantom on the conventional linac. Inserting a shim around the chamber induced changes of the chamber response in a magnetic field of up to 2.2%, but the change in chamber response on the conventional linac was less than 0.3%. CONCLUSIONS: The interaction between the magnetic field and secondary electrons in the air around the chamber reduces the charge collected from 0.7% to 1.2%. The large angular dependence of ion chambers measured in the plastic phantom in a magnetic field appears to arise from a change of air distribution as the chamber is moved within the insert, rather than an intrinsic isotropy of the chamber sensitivity to radiation. It is recommended that reference dosimetry measurements on the MR-linac can be performed only in water, rather than in existing plastic phantoms.


Assuntos
Ar , Imageamento por Ressonância Magnética/instrumentação , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/métodos , Desenho de Equipamento , Imageamento por Ressonância Magnética/métodos , Radioterapia Guiada por Imagem/instrumentação , Radioterapia Guiada por Imagem/métodos , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...