Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Infect Dis ; 104: 239-241, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33359672

RESUMO

Cowpox is a rare zoonosis transmitted to humans mainly from cats. The disease usually causes skin lesions; however, the ocular form may lead to other serious complications. We describe a case of cowpox in a rare location of the upper eyelid of an immunocompetent male, which lead to necrosis of the upper eyelid, keratitis and leucomatous opacity, and the neovascularization of the cornea. The patient underwent several surgeries, including reconstruction surgery of the eyelids, correction of the medial canthus, and corneal neurotization with supraorbicular nerve transplantation. Suspicion of cowpox should be made in patients where there are poorly healing skin lesions accompanied by a painful black eschar with erythema and local lymphadenopathy. Ocular cowpox may lead to serious complications and possibly mimic anthrax. Diagnosis of cowpox can be confirmed by detection of cowpox virus DNA by polymerase chain reaction. Patients should be advised to protect themselves while handling sick animals.


Assuntos
Vírus da Varíola Bovina/isolamento & purificação , Varíola Bovina/diagnóstico , Pálpebras/virologia , Adulto , Animais , Antraz/diagnóstico , Gatos , Varíola Bovina/patologia , Varíola Bovina/transmissão , DNA Viral/isolamento & purificação , Diagnóstico Diferencial , Pálpebras/patologia , Pálpebras/cirurgia , Humanos , Masculino , Necrose/diagnóstico , Reação em Cadeia da Polimerase , Procedimentos de Cirurgia Plástica/métodos , Pele/patologia , Zoonoses/diagnóstico , Zoonoses/transmissão
2.
J Ophthalmol ; 2018: 4691417, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30155282

RESUMO

PURPOSE: This randomized, observer-masked, crossover study investigated the effect of two hyaluronic acid/trehalose-based containing formulations, with different physical properties, on the signs and symptoms in patients with moderate to severe dry eye disease (DED). METHODS: In one group, patients received a mixture of sodium hyaluronate and trehalose (HT, Thealoz Duo®) for use during the day. In the other group, patients received a more viscous formulation consisting of hyaluronic acid, trehalose, and carbomer (HTC-gel, Thealoz Duo Gel) to use pro re nata. Both groups used HTC-gel before going to bed. Clinical standard tests for DED were performed at the beginning and end of each one-week period. Further, patient satisfaction including quality of sleep was assessed using a visual analogue scale. RESULTS: Corneal fluorescein and conjunctival lissamine green staining scores decreased, and tear breakup time (BUT) increased for both groups (p < 0.001 each). Mean instillation frequency was 3.1 ± 2.6 drops/day when using HT and 1.9 ± 2.2 drops/day when using HTC-gel (p=0.02). A significant improvement in the quality of sleep was observed with both treatments (p=0.01). CONCLUSIONS: Our results show improvement in signs and symptoms of DED in both groups. While instillation of HTC-gel resulted in a lower instillation frequency, both formulations of trehalose showed good clinical efficacy. This trial is registered with NCT02980913.

3.
Br J Ophthalmol ; 102(12): 1679-1683, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29472236

RESUMO

BACKGROUND/AIMS: There is considerable interest in novel techniques to quantify choroidal blood flow (CBF) in humans. In the present study, we investigated a novel technique to measure CBF based on laser speckle flowgraphy (LSFG) in healthy subjects. METHODS: This study included 31 eyes of 31 healthy, non-smoking subjects aged between 19 and 74 years. A commercial LSFG instrument was used to measure choroidal vessel diameter (CVD) and relative flow volume (RFV) in choroidal vessels that were identified on fundus photos, an approach that was used previously only for retinal vessels. The reproducibility and the effect of isometric exercise on these parameters were investigated. The latter was compared with measurement of subfoveal CBF using laser Doppler flowmetry (LDF). RESULTS: Intraclass correlation coefficients for CVD and RFV were higher than 0.8 indicating excellent reproducibility. During isometric exercise, we observed an increase in ocular perfusion pressure of approximately 60% (P<0.001). The increase in RFV and CBF was lower, but also highly significant versus baseline (at minute 6 of isometric exercise: RFV 10.5%±4.2%, CBF 8.3%±3.6%; P<0.001 each) indicating choroidal autoregulation. CONCLUSION: LSFG may be a novel approach to study blood flow in choroidal vessels. Data are reproducible and show good agreement with LDF data. TRIAL REGISTRATION NUMBER: NCT02102880, Results.


Assuntos
Corioide/irrigação sanguínea , Fluxometria por Laser-Doppler , Fluxo Sanguíneo Regional/fisiologia , Adolescente , Adulto , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Exercício Físico/fisiologia , Feminino , Voluntários Saudáveis , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
4.
PLoS One ; 12(9): e0184772, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28898284

RESUMO

The aim of the present study was to investigate regulation of blood flow (BF) in the optic nerve head (ONH) and a peripapillary region (PPR) during an isometric exercise-induced increase in ocular perfusion pressure (OPP) using laser speckle flowgraphy (LSFG) in healthy subjects. For this purpose, a total of 27 subjects was included in this study. Mean blur rate in tissue (MT) was measured in the ONH and in a PPR as well as relative flow volume (RFV) in retinal arteries (ART) and veins (VEIN) using LSFG. All participants performed isometric exercise for 6 minutes during which MT and mean arterial pressure were measured every minute. From these data OPP and pressure/flow curves were calculated. Isometric exercise increased OPP, MTONH and MTPRR. The relative increase in OPP (78.5 ± 19.8%) was more pronounced than the increase in BF parameters (MTONH: 18.1 ± 7.7%, MTPRR: 21.1 ± 8.3%, RFVART: 16.5 ±12.0%, RFVVEIN: 17.7 ± 12.4%) indicating for an autoregulatory response of the vasculature. The pressure/flow curves show that MTONH, MTPRR, RFVART, RFVVEIN started to increase at OPP levels of 51.2 ± 2.0%, 58.1 ± 2.4%, 45.6 ± 1.9% and 45.6 ± 1.9% above baseline. These data indicate that ONHBF starts to increase at levels of approx. 50% increase in OPP: This is slightly lower than the values we previously reported from LDF data. Signals from the PPR may have input from both, the retina and the choroid, but the relative contribution is unknown. In addition, retinal BF appears to increase at slightly lower OPP values of approximately 45%. LSFG may be used to study ONH autoregulation in diseases such as glaucoma. TRIAL REGISTRATION: ClinicalTrials.gov NCT02102880.


Assuntos
Exercício Físico , Nervo Óptico/fisiologia , Vasos Retinianos/fisiologia , Adolescente , Adulto , Pressão Sanguínea , Feminino , Humanos , Contração Isométrica , Fluxometria por Laser-Doppler/métodos , Masculino , Nervo Óptico/diagnóstico por imagem , Fluxo Sanguíneo Regional , Vasos Retinianos/diagnóstico por imagem
5.
Diabetologia ; 60(8): 1534-1540, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28547132

RESUMO

AIMS/HYPOTHESIS: The aim of this study was to compare retinal oxygen extraction in individuals with diabetes with no or mild non-proliferative diabetic retinopathy and healthy age- and sex-matched volunteers. METHODS: A total of 24 participants with type 1 diabetes and 24 healthy age- and sex-matched volunteers were included in this cross-sectional study. Retinal oxygen extraction was measured by combining total retinal blood flow measurements using a custom-built bi-directional Doppler optical coherence tomography system with measurements of oxygen saturation using spectroscopic reflectometry. Based on previously published mathematical modelling, the oxygen content in retinal vessels and total retinal oxygen extraction were calculated. RESULTS: Total retinal blood flow was higher in diabetic participants (46.4 ± 7.4 µl/min) than in healthy volunteers (40.4 ± 5.3 µl/min, p = 0.002 between groups). Oxygen content in retinal arteries was comparable between the two groups, but oxygen content in retinal veins was higher in participants with diabetes (0.15 ± 0.02 ml O2/ml) compared with healthy control participants (0.13 ± 0.02 ml O2/ml, p < 0.001). As such, the arteriovenous oxygen difference and total retinal oxygen extraction were reduced in participants with diabetes compared with healthy volunteers (total retinal oxygen extraction 1.40 ± 0.44 vs 1.70 ± 0.47 µl O2/min, respectively, p = 0.03). CONCLUSIONS/INTERPRETATION: Our data indicate early retinal hypoxia in individuals with type 1 diabetes with no or mild diabetic retinopathy as compared with healthy control individuals. Further studies are required to fully understand the potential of the technique in risk stratification and treatment monitoring. TRIAL REGISTRATION: ClinicalTrials.gov NCT01843114.


Assuntos
Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 1/patologia , Retinopatia Diabética/metabolismo , Retinopatia Diabética/patologia , Oxigênio/metabolismo , Retina/metabolismo , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Humanos , Masculino , Fluxo Sanguíneo Regional/fisiologia , Adulto Jovem
6.
Acta Ophthalmol ; 95(4): e307-e313, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27989018

RESUMO

PURPOSE: To compare the effect of a single drop of different lubricant eye gels on tear film thickness (TFT) as measured with ultrahigh-resolution optical coherence tomography (UHR-OCT) in patients with mild-to-moderate dry eye disease (DED). METHODS: The study followed a randomized, single-masked, observer-blinded parallel group design. Patients received a single dose of either unpreserved trehalose 3% + hyaluronic acid 0.15% (TH), hyaluronic acid 0.2% (HA) or polyethylene glycol 0.4% + propylene glycol 0.3% (PP) eye drops. In total, 60 patients were included and TFT was measured using a custom-built UHR-OCT system. RESULTS: The mean TFT at baseline was 3.5 ± 0.7 µm. There was a significant difference in the time-course of TFT between the three groups (p = 0.001 between groups). Ten minutes after instillation, TFT increased by 155.8 ± 86.6%, 65.7 ± 71.5% and 33.4 ± 19.6% in the PP, TH and HA group, respectively (p < 0.001 between groups). Thirty minutes after instillation, the effect of all three different agents on TFT was comparable. Sixty and 120 min after administration, a significant increase in TFT was only seen for the TH group, but not for the other products (60 min: p < 0.021 between groups; 120 min: p < 0.037 between groups). CONCLUSION: In conclusion, we observed differences in TFT after administration of the lubricant gels. Ten minutes after instillation, a pronounced increase in TFT was observed in all groups. As compared to the other products, the combination of trehalose 3% + hyaluronic acid 0.15% offers a significantly longer increase in TFT indicating for a longer residence time.


Assuntos
Síndromes do Olho Seco/tratamento farmacológico , Géis/administração & dosagem , Aumento da Imagem , Lubrificantes/administração & dosagem , Lágrimas/química , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/metabolismo , Feminino , Humanos , Ácido Hialurônico/administração & dosagem , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Polietilenoglicóis/administração & dosagem , Método Simples-Cego , Tensoativos/administração & dosagem , Lágrimas/efeitos dos fármacos , Viscossuplementos/administração & dosagem , Adulto Jovem
7.
PLoS One ; 11(12): e0168190, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27959905

RESUMO

PURPOSE: To assess the feasibility and reliability of Laser Speckle Flowgraphy (LSFG) to measure ocular perfusion in a sample of healthy white subjects and to elucidate the age-dependence of the parameters obtained. METHODS: This cross-sectional study included 80 eyes of 80 healthy, non-smoking white subjects of Western European descent between 19 and 79 years of age. A commercial LSFG instrument was applied to measure ocular blood flow at the optic nerve head (ONH) three successive times before and after pharmacological pupil dilation. The mean blur rate (MBR), a measure of relative blood flow velocity, was obtained for different regions of the ONH. Eight parameters of ocular perfusion derived from the pulse-waveform analysis of MBR including blowout time (BOT) and falling rate (FR) were also recorded. RESULTS: Artifact-free LSFG images meeting the quality criteria for automated image analysis were obtainable in 93.8% without pupil dilation and in 98.8% with pharmacological pupil dilation. Measurements of MBR showed excellent repeatability with intraclass correlation coefficients ≥ 0.937 and were barely affected by pupil dilation. The majority of pulse-waveform derived variables exhibited equally high repeatability. MBR-related blood flow indices exhibited significant age dependence (p<0.001). FR (r = 0.747, p<0.001) and BOT (r = -0.714, p<0.001) most strongly correlated with age. CONCLUSIONS: LSFG represents a reliable method for the quantitative assessment of ocular blood flow in white subjects. Our data affirms that the LSFG-derived variables FR and BOT may be useful biomarkers for age-related changes in ocular perfusion.


Assuntos
Fluxometria por Laser-Doppler , Disco Óptico/irrigação sanguínea , Adolescente , Adulto , Fatores Etários , Idoso , Artefatos , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Estudos Transversais , Feminino , Voluntários Saudáveis , Hemodinâmica , Humanos , Processamento de Imagem Assistida por Computador , Lasers , Masculino , Microcirculação/fisiologia , Pessoa de Meia-Idade , Pigmentação , Pupila/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Reprodutibilidade dos Testes , Fatores Sexuais , Fatores de Tempo , População Branca , Adulto Jovem
8.
Invest Ophthalmol Vis Sci ; 57(13): 5417-5425, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27756076

RESUMO

PURPOSE: This study evaluated the validity of retinal perfusion measurements using laser speckle flowgraphy (LSFG) by means of in vitro experiments and direct comparison with dual-beam Doppler optical coherence tomography (D-OCT) in a healthy Caucasian population. METHODS: The flow velocity of scattering solution pumped through a glass capillary was measured at 17 different flow velocities (range, 0.5-47 mm/s) using LSFG. The flow within the glass capillary was produced by a computer-controlled infusion pump. In vivo, three consecutive LSFG scans were obtained in 20 eyes of 20 healthy Caucasian subjects before and after pharmacological pupil dilation. Relative flow volume (RFV), the primary output parameter of LSFG, was comparatively validated relative to absolute measurements of retinal blood flow and velocity as obtained from D-OCT. RESULTS: In the in vitro experiments, RFV was found to saturate at a level of approximately 700 arbitrary units (au) or 23.5 mm/s of actual velocity. In vivo, RFV was in significant agreement with absolute blood flow measurements as obtained from D-OCT in arteries (r = 0.69, P = 0.001) and veins (r = 0.74, P < 0.001). However, linear regression analysis revealed significant positive zero offset values for RFV of 223.4 and 282.7 au in arteries and veins, respectively. CONCLUSIONS: Measurements of RFV were successfully obtainable, reproducible, and not influenced by pharmacological pupil dilation. Nevertheless, our data revealed flaws in the LSFG method of measuring retinal perfusion in Caucasians. Adjustment to the technique is required to address apparent issues with RFV, especially saturation effects with higher arterial flow rates. The present dataset may provide a valuable tool to do so. (Clinicaltrials.gov number NCT02582411).


Assuntos
Fluxometria por Laser-Doppler/métodos , Fluxo Sanguíneo Regional/fisiologia , Vasos Retinianos/fisiologia , Tomografia de Coerência Óptica/métodos , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Vasos Retinianos/diagnóstico por imagem
9.
JAMA Ophthalmol ; 134(10): 1169-1176, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27584715

RESUMO

IMPORTANCE: Corneal abrasions are frequent after standard (epithelium-off [epi-off]) corneal collagen cross-linking (CXL) in patients with progressive keratoconus. A new matrix therapy agent (ReGeneraTing Agent [RGTA]) has been developed to promote corneal wound healing. OBJECTIVE: To assess the effect of the new type of matrix therapy agent on corneal wound healing after epi-off CXL in patients with keratoconus. DESIGN, SETTING, AND PARTICIPANTS: This double-masked randomized clinical trial enrolled 40 patients with keratoconus undergoing epi-off CXL from July 18, 2014, to October 21, 2015, when the last follow-up was completed. The analysis of the intention-to-treat population was performed at the Department of Clinical Pharmacology in cooperation with the Center for Medical Physics and Biomedical Engineering and the Department of Ophthalmology and Optometry of the Medical University of Vienna. INTERVENTIONS: Patients were randomized to receive the matrix therapy agent or hyaluronic acid-containing eyedrops, 0.1%, every other day starting immediately after surgery. The size of the corneal defect was measured using ultrahigh-resolution optical coherence tomography (OCT) and slitlamp photography (SLP) with fluorescein staining. MAIN OUTCOMES AND MEASURES: Corneal wound healing rate, defined as the size of the defect over time. RESULTS: Among the 40 patients undergoing epi-off CXL (31 men; 9 women; mean [SD] age, 31 [10] years), wound healing was significantly faster in the matrix therapy agent group compared with the hyaluronic acid group (4.4 vs 6.1 days; mean difference, 1.7 days; 95% CI, 0.25-3.15 days; P = .008). The defect size was smaller in the matrix therapy agent group than in the hyaluronic acid group as measured with OCT (12.4 vs 23.9 mm2; mean difference, 11.6 mm2; 95% CI, 0.8-23.5 mm2; P = .045) and SLP (11.9 vs 23.5 mm2; mean difference, 11. 6 mm2; 95% CI, 1.3-22.9 mm2; P = .03). A correlation between the defect size measured with OCT and SLP was found (r = 0.89; P < .001). No ocular or serious adverse events occurred. CONCLUSIONS AND RELEVANCE: Use of a new matrix therapy agent appears to improve corneal wound healing after CXL in patients with keratoconus. Monitoring of corneal wound healing using ultrahigh-resolution OCT might be an attractive alternative to SLP because OCT provides an objective and 3-dimensional evaluation of the corneal defect. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT02119039.


Assuntos
Colágeno/uso terapêutico , Reagentes de Ligações Cruzadas/uso terapêutico , Epitélio Corneano/efeitos dos fármacos , Ceratocone/tratamento farmacológico , Cicatrização/efeitos dos fármacos , Adolescente , Adulto , Epitélio Corneano/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Ácido Hialurônico/uso terapêutico , Ceratocone/diagnóstico , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Estudos Retrospectivos , Fatores de Tempo , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Viscossuplementos/uso terapêutico , Acuidade Visual , Adulto Jovem
10.
Invest Ophthalmol Vis Sci ; 57(9): OCT121-9, 2016 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-27409462

RESUMO

PURPOSE: To compare retinal vessel calibers extracted from phase-sensitive optical coherence tomography (OCT) images with vessel calibers as obtained from the Retinal Vessel Analyzer (RVA). METHODS: Data from previously published studies in 13 healthy subjects breathing room air (n = 214 vessels) and 7 subjects breathing 100% oxygen (n = 101 vessels) were used. Vessel calibers from OCT phase images were measured vertically along the optical axis by three independent graders. The data from RVA fundus images were corrected for magnification to obtain absolute values. RESULTS: The average vessel diameter as obtained from OCT images during normoxia was lower than from RVA images (83.8 ± 28.2 µm versus 86.6 ± 28.0 µm, P < 0.001). The same phenomenon was observed during 100% oxygen breathing (OCT: 81.0 ± 22.4 µm, RVA: 85.5 ± 26.0 µm; P = 0.001). Although the agreement between the two methods was generally high, the difference in individual vessels could be as high as 40%. These differences were neither dependent on absolute vessel size nor preferably found in specific subjects. Interobserver differences between OCT evaluators were much lower than differences between the techniques. CONCLUSIONS: Extracting vessel calibers from OCT phase images may be an attractive approach to overcome some of the problems associated with fundus imaging. The source of differences in vessel caliber between the two methods remains to be investigated. In addition, it remains unclear whether OCT-based vessel caliber measurement is superior to fundus camera-based imaging in risk stratification for systemic or ocular disease. (ClinicalTrials.gov numbers, NCT00914407, NCT02531399.).


Assuntos
Angiofluoresceinografia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Artéria Retiniana/diagnóstico por imagem , Veia Retiniana/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Feminino , Fundo de Olho , Voluntários Saudáveis , Humanos , Masculino , Fotografação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA