1.
Med Biol Eng Comput ; 43(2): 212-7, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15865130

RESUMO

Heart sounds can be considered as mechanical fingerprints of myocardial function. The third heart sound normally occurs in children but disappears with maturation. The sound can also appear in patients with heart failure. The sound is characterised by its low-amplitude and low-frequency content, which makes it difficult to identify by the traditional use of the stethoscope. A wavelet-based method has recently been developed for detection of the third heart sound. This study investigated if the third heart sound could be identified in patients with heart failure using this detection method. The method was also compared with auscultation using conventional phonocardiography and with characterisation of the patients with echocardiography. In the first study, 87% of the third heart sounds were detected using the wavelet method, 12% were missed, and 6% were false positive. In study 2, the wavelet-detection method identified 87% of the patients using the third heart sound, and regular phonocardiography identified two (25%) of the subjects.


Assuntos
Auscultação Cardíaca/métodos , Insuficiência Cardíaca/diagnóstico , Ruídos Cardíacos , Processamento de Sinais Assistido por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fonocardiografia
2.
Technol Health Care ; 12(4): 323-32, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15502283

RESUMO

Reliable monitoring of respiration plays an important role in a broad spectrum of applications. Today, there are several methods for monitoring respiration, but none of them has proved to be satisfactory in all respects. We have recently developed a bioacoustic method that can accurately time respiration from tracheal sounds. The aim of this study is to tailor this bioacoustic method for monitoring purposes by introducing dedicated signal processing. The method was developed on a material of ten patients and then tested in another ten patients treated in an intensive care unit. By studying the differences in the variation of the spectral content between the different phases of respiration, the described method can distinguish between inspiration and expiration and can extract respiration frequency, and respiration pause periods. The system detected 98% of the inspirations and 99% of the expirations. This method for respiration monitoring has the advantage of being simple, robust and the sensor does not need to be placed closed to the face. A commercial heart microphone was used and we anticipate that further improvement in performance can be achieved trough optimization of sensor design.


Assuntos
Acústica , Auscultação , Monitorização Fisiológica/métodos , Respiração , Algoritmos , Humanos , Processamento de Sinais Assistido por Computador
3.
Med Biol Eng Comput ; 42(2): 253-8, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15125157

RESUMO

The third heart sound is normally heard during auscultation of younger individuals but disappears with increasing age. However, this sound can appear in patients with heart failure and is thus of potential diagnostic use in these patients. Auscultation of the heart involves a high degree of subjectivity. Furthermore, the third heart sound has low amplitude and a low-frequency content compared with the first and second heart sounds, which makes it difficult for the human ear to detect this sound. It is our belief that it would be of great help to the physician to receive computer-based support through an intelligent stethoscope, to determine whether a third heart sound is present or not. A precise, accurate and low-cost instrument of this kind would potentially provide objective means for the detection of early heart failure, and could even be used in primary health care. In the first step, phonocardiograms from ten children, all known to have a third heart sound, were analysed, to provide knowledge about the sound features without interference from pathological sounds. Using this knowledge, a tailored wavelet analysis procedure was developed to identify the third heart sound automatically, a technique that was shown to be superior to Fourier transform techniques. In the second step, the method was applied to phonocardiograms from heart patients known to have heart failure. The features of the third heart sound in children and of that in patients were shown to be similar. This resulted in a method for the automatic detection of third heart sounds. The method was able to detect third heart sounds effectively (90%), with a low false detection rate (3.7%), which supports its clinical use. The detection rate was almost equal in both the children and patient groups. The method is therefore capable of detecting, not only distinct and clearly visible/audible third heart sounds found in children, but also third heart sounds in phonocardiograms from patients suffering from heart failure.


Assuntos
Insuficiência Cardíaca/diagnóstico , Ruídos Cardíacos , Fonocardiografia/métodos , Processamento de Sinais Assistido por Computador , Adolescente , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Diagnóstico por Computador/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
J Intern Med ; 253(4): 411-7, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12653869

RESUMO

BACKGROUND: Percutaneous pericardiocentesis guided by 2-D echocardiography has been used at Linköping Heart Centre since 1983. AIM: To evaluate our experience of this method including a follow-up and also to determine the aetiology of pericardial effusion. METHODS: A retrospective study including 120 of 252 consecutive patients punctured. RESULTS: The two most common aetiologies were cardiac surgery (77% valve surgery), followed by malignant disease. The postsurgical effusions became clinically important a median of 12 days after surgery (range 0-56 days). The median survival in the group with malignant disease was 89 days (30-day survival 87%, 1-year survival 10%). Indwelling catheter was used in 93% of the patients. There was no mortality but one patient needed a second pericardiocentesis after an accidental puncture of the right ventricle. Nine patients had rhythm aberrations. Recurring effusion that needed puncture was seen in 8%. CONCLUSION: Pericardiocentesis guided by 2-D echocardiography is a safe and efficient method to treat pericardial effusion and also valuable as palliative treatment for patients with malignant aetiology of the effusion.


Assuntos
Tamponamento Cardíaco/cirurgia , Ecocardiografia/métodos , Derrame Pericárdico/cirurgia , Pericardiocentese/métodos , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico/diagnóstico por imagem , Derrame Pericárdico/etiologia , Estudos Retrospectivos , Resultado do Tratamento
5.
J Biomech Eng ; 124(3): 288-93, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12071263

RESUMO

Understanding cardiac blood flow patterns is important in the assessment of cardiovascular function. Three-dimensional flow and relative pressure fields within the human left ventricle are demonstrated by combining velocity measurements with computational fluid mechanics methods. The velocity field throughout the left atrium and ventricle of a normal human heart is measured using time-resolved three-dimensional phase-contrast MRI. Subsequently, the time-resolved three-dimensional relative pressure is calculated from this velocity field using the pressure Poisson equation. Noninvasive simultaneous assessment of cardiac pressure and flow phenomena is an important new tool for studying cardiac fluid dynamics.


Assuntos
Função do Átrio Esquerdo/fisiologia , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Modelos Cardiovasculares , Reologia/métodos , Pressão Ventricular/fisiologia , Velocidade do Fluxo Sanguíneo , Feminino , Hemodinâmica , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Pressão
6.
J Am Soc Echocardiogr ; 14(10): 959-69, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11593200

RESUMO

The goals of this study were to evaluate possible normal age-related changes in regional myocardial relaxation as detected by color Doppler myocardial imaging (CDMI) velocities and to compare the extent of any such changes with age-induced changes in global diastolic function. In 80 healthy subjects (aged 21 to 72 years, equally subdivided by decades) the mitral flow velocities in early diastole (E) and atrial contraction (A) were recorded as were the velocities of left ventricular (LV) motion of early (EDV) and late diastole (LDV) in the 16 standard LV segments, and their ratios were calculated. In healthy persons younger than 40 years, all segments showed an EDV/LDV ratio > 1, whereas in healthy persons aged 40 years or older the mean EDV of all segments decreased, and the mean LDV increased, resulting in a significant decrease of the mean EDV/LDV ratio with age. Values of EDV/LDV ratios were higher than E/A ratios (P <.0001), but their changes with age correlated well with each other (r = 0.805). With increasing age, an EDV/LDV ratio <1 was observed more often in basal segments (P <.001, compared with mid and apical segments) and less often in segments of anteroseptal and posterior walls viewed from the parasternal window. The presence of >50% segments with an EDV/LDV ratio <1 was associated with an E/A ratio <1. Regional diastolic function indexes as evaluated by CDMI changed with increasing age in a heterogeneous way and influenced global diastolic function parameters.


Assuntos
Envelhecimento/fisiologia , Pressão Sanguínea/fisiologia , Ecocardiografia Doppler em Cores , Adulto , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Projetos de Pesquisa
7.
Clin Physiol ; 21(5): 621-8, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11576164

RESUMO

AIMS: Mitral atrioventricular plane displacement (AVPD) provides information about left ventricular systolic function. M-mode of systolic annulus amplitude or tissue Doppler imaging of systolic annulus velocity are the current methods of evaluating AVPD. A correlation to ejection fraction (EF) has been demonstrated in patients with coronary artery disease and left ventricular dysfunction. Our aim was (i) to investigate the mitral AVPD of normal subjects with different physical work capacities and (ii) to further evaluate AVPD as an index of left ventricular systolic function. METHODS AND RESULTS: Twenty-eight healthy men mean age 28 years (20-39) were included: endurance trained (ET) (n=10), strength trained (ST) (n=9) and untrained (UT) (n=9). The systolic AVPD was recorded at four sites, septal, lateral, anterior and posterior, using M-mode. Left ventricular volumes were calculated according to Simpson's rule. Systolic AVPD was higher in endurance trained, 16.9 +/- 1.5 mm, as compared with both strength trained, 13 +/- 1.6 (P<0.001) and untrained, 14 +/- 1.6 (P<0.001). Left ventricular systolic AVPD correlated strongly with end-diastolic volume (r=0.82), stroke volume (r=0.80) and maximal oxygen consumption per body weight (r=0.72). The correlation between AVPD and EF was poor (r=0.22). CONCLUSION: In the subjects studied, with a range of normal cardiac dimensions, AVPD correlated to stroke volume, end-diastolic volume and maximal oxygen consumption per body weight, but not to EF. On theoretical grounds, it also seems reasonable that a dimension like AVPD is related to other cardiac dimensions and volumes, rather than to a fraction, like EF. AVPD is one parameter that is useful for evaluation of left ventricular systolic function but is not interchangeable with other measurements such as EF.


Assuntos
Circulação Sanguínea , Ecocardiografia , Volume Sistólico , Função Ventricular Esquerda , Adulto , Humanos , Masculino , Valva Mitral/fisiologia , Educação Física e Treinamento , Resistência Física , Valores de Referência , Esportes , Sístole
8.
J Thorac Cardiovasc Surg ; 122(2): 287-95, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11479501

RESUMO

OBJECTIVES: We sought to evaluate the Doppler assessment of effective orifice area in aortic prosthetic valves. The effective orifice area is a less flow-dependent parameter than Doppler gradients that is used to assess prosthetic valve function. However, in vivo reference values show a pronounced spread of effective orifice area and smaller orifices than expected compared with the geometric area. METHODS: Using Doppler echocardiography, we studied patients who received a bileaflet St Jude Medical valve (n = 75; St Jude Medical, Inc, St Paul, Minn) or a tilting disc Omnicarbon valve (n = 46; MedicalCV, Incorporated, Inver Grove Heights, Minn). The prosthetic valves were also investigated in vitro in a steady-flow model with Doppler and catheter measurements in the different orifices. The effective orifice area was calculated according to the continuity equation. RESULTS: In vivo, there was a wide distribution with the coefficient of variation (SD/mean x 100%) for different valve sizes ranging from 21% to 39% in the St Jude Medical valve and from 25% to 33% in the Omnicarbon valve. The differences between geometric orifice area and effective orifice area in vitro were 1.26 +/- 0.41 cm(2) for St Jude Medical and 1.17 +/- 0.38 cm(2) for Omnicarbon valves. The overall effective orifice areas and peak catheter gradients were similar: 1.35 +/- 0.37 cm(2) and 25.9 +/- 16.1 mm Hg for St Jude Medical and 1.46 +/- 0.49 cm(2) and 24.6 +/- 17.7 mm Hg for Omnicarbon. However, in St Jude Medical valves, more pressure was recovered downstream, 11.6 +/- 6.3 mm Hg versus 3.4 +/- 1.6 mm Hg in Omnicarbon valves (P =.0001). CONCLUSIONS: In the patients, we found a pronounced spread of effective orifice areas, which can be explained by measurement errors or true biologic variations. The in vitro effective orifice area was small compared with the geometric orifice area, and we suspect that nonuniformity in the spatial velocity profile causes underestimation. The St Jude Medical and Omnicarbon valves showed similar peak catheter gradients and effective orifice areas in vitro, but more pressure was recovered in the St Jude Medical valve. The effective orifice area can therefore be misleading in the assessment of prosthetic valve performance when bileaflet and tilting disc valves are compared.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia Doppler , Próteses Valvulares Cardíacas , Valva Aórtica/fisiopatologia , Determinação da Pressão Arterial , Hemodinâmica , Humanos , Técnicas In Vitro , Modelos Lineares , Modelos Cardiovasculares , Desenho de Prótese
11.
Heart ; 86(1): 31-8, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11410558

RESUMO

OBJECTIVE: To evaluate new echocardiographic modes in the diagnosis of arrhythmogenic right ventricular cardiomyopathy (ARVC). DESIGN: Prospective observational study. SETTING: University Hospital. SUBJECTS: 15 patients with ARVC and a control group of 25 healthy subjects. METHODS: Transthoracic echocardiography included cross sectional measurements of the right ventricular outflow tract, right ventricular inflow tract, and right ventricular body. Wall motion was analysed subjectively. M mode and pulsed tissue Doppler techniques were used for quantitative measurement of tricuspid annular motion at the lateral, septal, posterior, and anterior positions. Doppler assessment of tricuspid flow and systemic venous flow was also performed. RESULTS: Assessed by M mode, the total amplitude of the tricuspid annular motion was significantly decreased in the lateral, septal, and posterior positions in the patients compared with the controls. The tissue Doppler velocity pattern showed decreased early diastolic peak annular (E(A)) velocity and an accompanying decrease in early (E(A)) to late diastolic (A(A)) velocity ratio in all positions; the systolic annular velocity was significantly decreased only in the lateral position. Four patients had normal right ventricular dimensions and three were judged to have normal right ventricular wall motion. The patient group had also a significantly decreased tricuspid flow E:A ratio. CONCLUSIONS: Tricuspid annular measurements are valuable, easy to obtain, and allow quantitative assessment of right ventricular function. ARVC patients showed an abnormal velocity pattern that may be an early but non-specific sign of the disease. Normal right ventricular dimensions do not exclude ARVC, and subjective detection of early changes in wall motion may be difficult.


Assuntos
Displasia Arritmogênica Ventricular Direita/diagnóstico por imagem , Ecocardiografia/métodos , Adulto , Estudos de Casos e Controles , Ecocardiografia Doppler de Pulso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos
12.
J Am Soc Echocardiogr ; 14(5): 391-5, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11337685

RESUMO

Constrictive pericarditis and restrictive cardiomyopathy can be difficult to differentiate on clinical examination. Cardiac ultrasonography is increasingly being used as the noninvasive method of choice for confirming the specific morphologic and hemodynamic abnormalities associated with either condition. Interrogation of atrioventricular valve plane motion by Doppler myocardial imaging (DMI) has been suggested as a valuable new approach that can help differentiate one from the other. We report the color DMI, pulsed DMI, and strain rate findings in 2 cases of constrictive pericarditis in which consideration of the annular motion pattern alone would not have allowed such differentiation.


Assuntos
Ecocardiografia Doppler , Pericardite Constritiva/diagnóstico por imagem , Cardiomiopatia Restritiva/diagnóstico por imagem , Diagnóstico Diferencial , Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Humanos , Masculino , Pessoa de Meia-Idade
13.
Eur J Echocardiogr ; 2(3): 178-86, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11882451

RESUMO

AIMS: Doppler myocardial imaging is potentially a sensitive tool to assess regional myocardial velocities pre- and post-percutaneous transluminal coronary angioplasty (PTCA) as a marker of contractility to evaluate short- to medium-term information on functional myocardial recovery following the release of ischaemia. METHODS: Thirty patients with single vessel disease were studied to assess regional myocardial peak systolic velocity, systolic velocity time integral and mitral valve plane excursion in longitudinal direction one day pre-, one day post- and 3 months post-PTCA. The patients were assigned to group A with coronary stenoses >70% and group B with stenoses < 70%. RESULTS: In group A pre-PTCA the ischaemic segments showed a significantly lower peak systolic velocity and velocity time integral compared with the values one day after PTCA (5.8 +/- 1.4 vs 7.7 +/- 1.4cm.s(-1); 1.06 +/- 0.22 vs 1.23 +/-0.28cm;P< 0.03). In contrast, mitral valve plane excursion in this group remained unchanged after PTCA for both the ischaemic and non-ischaemic left ventricular wall. In group B no changes of these parameters and no differences in mitral valve plane excursion of the ischaemic and the non-ischaemic left ventricular wall could be seen. CONCLUSION: With Doppler myocardial imaging it was possible to quantify a number of indices which changed due to the successful release of ischaemia.


Assuntos
Ecocardiografia Doppler de Pulso , Isquemia Miocárdica/diagnóstico por imagem , Angioplastia Coronária com Balão , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Humanos , Pessoa de Meia-Idade , Isquemia Miocárdica/terapia , Estudos Prospectivos
14.
Echocardiography ; 17(7): 639-51, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11107200

RESUMO

The objective was to compare velocity information derived from either a tissue mimicking phantom or normal contracting myocardium by both pulsed wave and color Doppler myocardial imaging (PWDMI and CDMI). Both CDMI and PWDMI allow quantitative assessment of regional myocardial contraction and relaxation velocities, but their potential clinical applications have not yet been investigated. Moreover, no information is available as to whether they can be used interchangeably for regional velocity assessment. For the in vitro study, a rotating, circular-shaped, tissue-mimicking sponge driven by a motor at speeds of 15, 30, 60, 90 rpm was used to derive velocity data from the same eight points of interest by using PWDMI or CDMI techniques. For the in vivo study, 25 normal subjects were examined at rest using parasternal and apical approaches. Velocity profiles were derived from the same 26 areas of interest (18 left ventricular segments, 3 right ventricular segments, and 5 measurement points for the tricuspid and mitral annuli) for each technique. Peak maximal velocities were detected by PWDMI and peak mean velocities were measured using CDMI. The results of the in vitro study phantom showed excellent correlation (r = 0.99, P < 0. 001) and satisfactory agreement (0.04 cm/sec; 3.3 cm/sec) between both Doppler techniques. PWDMI velocities were higher than CDMI velocities by up to 20% and overestimated the real velocity value (0. 37 +/- 0.29 cm/sec) while CDMI underestimated predicted velocity by 1.35 +/- 0.36 cm/sec. Good correlation (r = 0.87, P < 0.001), but poor agreement (-2.1 cm/sec; 5.4 cm/sec) was shown in vivo for all segments with regard to peak systolic and diastolic velocities. Both Doppler techniques cannot be used interchangeably for comparing peak velocities in the clinical situation. However, with adequate temporal resolution, they can be used interchangeably for velocity profile recording and for timing of events.


Assuntos
Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Contração Miocárdica/fisiologia , Adolescente , Adulto , Idoso , Análise de Variância , Intervalos de Confiança , Interpretação Estatística de Dados , Diástole/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Sístole/fisiologia
16.
Med Eng Phys ; 22(6): 425-33, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11086254

RESUMO

It is well known that the flow of air through the trachea during respiration causes vibrations in the tissue near the trachea, which propagate to the surface of the body and can be picked up by a microphone placed on the throat over the trachea. Since the vibrations are a direct result of the airflow, accurate timing of inspiration and expiration is possible. This paper presents a signal analysis solution for automated monitoring of breathing and calculation of the breathing frequency. The signal analysis approach uses tracheal sound variables in the time and frequency domains, as well as the characteristics of the disturbances that can be used to discriminate tracheal sound from noise. One problem associated with the bioacoustic method is its sensitivity for acoustic disturbances, because the microphone tends to pick up all vibrations, independent of their origin. A signal processing method was developed that makes the bioacoustic method clinically useful in a broad variety of situations, for example in intensive care and during certain heart examinations, where information about both the precise timing and the phases of breathing is crucial.


Assuntos
Acústica/instrumentação , Monitorização Fisiológica/métodos , Ventilação Pulmonar/fisiologia , Sons Respiratórios/fisiologia , Processamento de Sinais Assistido por Computador , Adulto , Feminino , Humanos , Masculino , Modelos Biológicos , Monitorização Fisiológica/instrumentação , Tempo de Reação/fisiologia , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador/instrumentação , Traqueia/fisiologia
17.
Am J Cardiol ; 86(4A): 4G-9G, 2000 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-10997344

RESUMO

The clinical evaluation of regional delays in myocardial motion (myocardial asynchrony) has proved problematic, yet it remains an important functional parameter to evaluate. Prior attempts to quantify regional asynergy have met with limited success, often thwarted by the low temporal resolution of imaging-system data acquisition. If a delay in onset of motion of 30-40 msec is clinically important to measure, then data acquisition at frame rates of 50-100 per second is required. This is out of the current temporal resolution of angiographic, nuclear, or magnetic resonance studies. Only cardiac ultrasound can currently achieve the necessary frame rates. Furthermore, quantitative studies into the accuracy with which a trained observer can identify computed regional myocardial asynchrony in a left-ventricular 2-dimensional (2-D) image have shown that regional delays of < 80 msec are not normally recognized in a moving image. This may be improved to 60 msec when either training is undertaken or comparative image review is used. However, this is still out of the temporal resolution required in clinical practice. Thus, visual interpretation of asynchrony is not sufficiently accurate. Two ultrasound data sets based on either integrated backscatter or Doppler myocardial imaging data may provide the solution. Doppler myocardial imaging is a new ultrasound technique which, in either its pulsed or color Doppler format, can achieve the required temporal resolution (with temporal resolutions of 8 msec and 16 msec, respectively). In contrast, color Doppler myocardial imaging, in its curved M-mode format, can display the timing of events during the cardiac cycle for all in-plane myocardial segments. This should allow the quantitation of regional delay for all systolic and diastolic events. Potentially, asynchrony due to regional ischemia, bundle branch block, ventricular premature beats, and ventricular preexcitation could all be identified and the degree of delay quantified. This overview will aim to establish the potential role of these new ultrasound methodologies in the recognition and quantitation of left-ventricular asynergy and how they might best be introduced into clinical practice.


Assuntos
Ecocardiografia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Ecocardiografia/métodos , Ecocardiografia Doppler , Ecocardiografia Doppler em Cores , Humanos
18.
Scand Cardiovasc J ; 34(3): 331-8, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10935782

RESUMO

Abnormal right heart function after cardiac surgery is a well-known finding. Inadequate preservation during the operation and restricted cardiac motion due to pericardial adhesions have been proposed as underlying mechanisms. This study focuses on the impact of a pericardial substitute implantation on right ventricular function, using echocardiography and magnetic resonance imaging. A test group of six patients (mean age 54 years) was examined before surgery, and 4-15 days and 5-9 months after coronary artery bypass surgery, where the pericardium was closed with a biodegradable pericardial patch. A group of 11 patients (mean age 63 years) in whom the pericardium was left open served as controls. Tricuspid annulus motion was markedly decreased, abnormal septal motion was present and decreased systolic to diastolic ratio in the vena cava superior flow was present in all patients in both groups one week after surgery. At the late follow-up, all patients still had decreased tricuspid annulus motion, while 17% of the patients in the test group and 22% of the patients in the control group (ns) demonstrated normal septal motion. We conclude that closing the pericardium with a biodegradable patch does not affect the postoperative changes in right heart function normally seen after open-heart surgery.


Assuntos
Ponte de Artéria Coronária , Ecocardiografia , Imageamento por Ressonância Magnética , Pericárdio/cirurgia , Poliésteres , Complicações Pós-Operatórias/diagnóstico , Implantação de Prótese , Função Ventricular Direita/fisiologia , Idoso , Ecocardiografia Doppler , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Aderências Teciduais/prevenção & controle , Valva Tricúspide/fisiopatologia , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/fisiopatologia
19.
Z Kardiol ; 89 Suppl 1: 86-96, 2000.
Artigo em Alemão | MEDLINE | ID: mdl-10907306

RESUMO

The intravenous application of an ultrasound contrast agent induces enhanced display of blood in all its pathways. Within cardiology, this principle is mainly utilized for signal enhancement of color Doppler and spectral Doppler in order to improve quantification of congenital and acquired valvular lesions and also for improved endocardial delineation during stress tests and in the evaluation of LV function. The new domaine of myocardial perfusion imaging by contrast echocardiography, however, needed profound technical developments before realization of the clinical potential could even be conceived. These are based on the complex reactions of microbubbbles in the acoustic field in order to allow the sensitive and bubble specific display of intramyocardial contrast effects. The presently available acquisition techniques, second harmonic imaging and harmonic power Doppler, demonstrate significant improvements if compared to traditional fundamental 2-d echocardiography; however, they are still subjected to important limitations. There are many anatomical, physiological, and technical reasons for insufficient display of intramyocardial microbubbles, the most important one being attenuation. It is hoped that the most recently developed imaging modality, pulse inversion technique, allows the necessary diagnostic accuracy and reproducibility in myocardial perfusion imaging.


Assuntos
Meios de Contraste , Ecocardiografia Doppler em Cores , Cardiopatias/diagnóstico por imagem , Cardiopatias/fisiopatologia , Hemodinâmica/fisiologia , Humanos , Aumento da Imagem , Sensibilidade e Especificidade
20.
Magn Reson Med ; 43(5): 734-8, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10800039

RESUMO

The acceleration-induced displacement artifact impairs the accuracy of MR velocity measurements. This study proposes a post processing method for correction of this artifact. Velocity measurements were performed in a flow phantom containing a constriction. Velocity curves were obtained from streamlines parallel to the frequency, phase, and slice directions, respectively. The acceleration-induced displacement artifact was most prominent when the frequency encoding direction was aligned with the flow direction. After correction, velocity assignment improved and a more accurate description of the flow was obtained. In vivo measurements were performed in the aorta in a patient with a repaired aortic coarctation. The correction method was applied to velocity data along a streamline parallel to the frequency encoding direction. The result after correction was a new location of the peak velocity and improved estimates of the velocity gradients.


Assuntos
Artefatos , Velocidade do Fluxo Sanguíneo , Imageamento por Ressonância Magnética , Adulto , Algoritmos , Aorta Torácica/patologia , Constrição Patológica , Humanos , Masculino , Modelos Estruturais