Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
J Hazard Mater ; 477: 135403, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39096644

RESUMO

Drug resistance poses a high risk to human health. Extensive use of non-antibiotic drugs contributes to antibiotic resistance genes (ARGs) transfer. However, how they affect the spread of broad-host plasmids in complex biological systems remains unknown. This study investigated the effect of metoprolol on the transfer frequency and host range of ARGs in both intrageneric and intergeneric pure culture systems, as well as in anammox microbiome. The results showed that environmental concentrations of metoprolol significantly promoted the intrageneric and intergeneric conjugative transfer. Initially, metoprolol induced excessive oxidative stress, resulting in high cell membrane permeability and bacterial SOS response. Meanwhile, more pili formation increased the adhesion and contact between bacteria, and the abundance of conjugation-related genes also increased significantly. Activation of the electron transport chain provided more ATP for this energy-consuming process. The underlying mechanism was further verified in the complex anammox conjugative system. Metoprolol induced the enrichment of ARGs and mobile genetic elements. The enhanced bacterial interaction and energy generation facilitated the high conjugative transfer frequency of ARGs. In addition, plasmid-borne ARGs tended to transfer to opportunistic pathogens. This work raises public concerns about the health and ecological risks of non-antibiotic drugs.

2.
Heliyon ; 10(11): e32764, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38912508

RESUMO

Enhancing selenium content in millet is a crucial strategy to address malnutrition due to selenium deficiency. Jingu 21 was used as the experimental material in this study. The effects of selenium fertilizer application amount, vertical position of fertilization, and horizontal position of fertilization on the selenium content in various millet organs were assessed using a three-factor, five-level quadratic rotation combination design. The results indicate that selenium fertilizer application amount, vertical fertilization position, and horizontal fertilization position significantly affected the selenium content in various millet organs. Analysis of the selenium accumulation for different millet organs show that the recommended optimal agronomic strategy for producing selenium-enriched millet comprises a selenium fertilizer application amount ranging from 100.65 to 120.15 kg/hm2, a vertical fertilization position of 10.28-11.76 cm, and a horizontal fertilization position of 6.74-7.29 cm. This study elucidates the patterns of selenium content accumulation under precise fertilization measures of millet and provides valuable insights for implementing selenium enhancement techniques in the production of selenium-enriched millet.

3.
Environ Res ; 256: 119160, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38754613

RESUMO

Addressing cadmium (Cd) contamination in agricultural lands is crucial, given its health implications and accumulation in crops. This study used pot experiments to evaluate the impact of foliar selenium spray (Se) (0.40 mM), corn straw biochar (1%), and pig manure (1%) on the growth of rice plants, the accumulation of Cd in rice grain, and to examine their influence on health risk indices associated with Cd exposure. The treatments were designated as follows: a control group without any amendment (CK), biochar (T1), pig manure (T2), Se (T3), Se and biochar (T4), Se and pig manure (T5), and Se along with biochar and pig manure (T6). Our results indicated that the treatments affected soil pH and redox potential and improved growth and the nitrogen and phosphorus content in rice plants. The soil-plant analysis development (SPAD) meter readings of leaves during the tillering stage indicated a 5.27%-15.86% increase in treatments T2 to T6 compared to CK. The flag leaves of T2 exhibited increases of 12.06%-38.94% for electrolyte leakage and an 82.61%-91.60% decline in SOD compared to treatments T3 to T6. Treatments T1 to T6 increased protein content; however, amylose content was significantly reduced in T6. Treatment T6 recorded the lowest Cd concentration in rice grains (0.018 mg/kg), while T2 recorded the highest (0.051 mg/kg). The CK treatment group showed a grain Cd content reduction of 29.30% compared to T2. The assessment of acceptable daily intake, hazard quotient, and carcinogenic risk revealed an ascending order as follows: T6 < T3 < T5 < T4 < T1 < CK < T2. In conclusion, the application of treatment T6 demonstrates the potential to lower oxidative stress, enhance production, reduce cancer risk, and ensure the safe cultivation of rice in environments affected by Cd contamination.


Assuntos
Cádmio , Carvão Vegetal , Esterco , Oryza , Selênio , Poluentes do Solo , Oryza/metabolismo , Oryza/química , Oryza/crescimento & desenvolvimento , Cádmio/análise , Cádmio/metabolismo , Selênio/análise , Selênio/metabolismo , Esterco/análise , Animais , Carvão Vegetal/química , Poluentes do Solo/análise , Suínos , Folhas de Planta/química , Folhas de Planta/metabolismo , Medição de Risco , Humanos
5.
Adv Drug Deliv Rev ; 207: 115201, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38331256

RESUMO

Although nanotechnology has evolutionarily progressed in biomedical field over the past decades, achieving satisfactory therapeutic effects remains difficult with limited delivery efficiency. Ultrasound could provide a deep penetration and maneuverable actuation to efficiently power micro-/nanoswimmers with little harm, offering an emerging and fascinating alternative to the active delivery platform. Recent advances in novel fabrication, controllable concepts like intelligent swarm and the integration of hybrid propulsions have promoted its function and potential for medical applications. In this review, we will summarize the mechanisms and types of ultrasonically propelled micro/nanorobots (termed here as "AcousticRobots"), including the interactions between AcousticRobots and acoustic field, practical design considerations (e.g., component, size, shape), the synthetic methods, surface modification, controllable behaviors, and the advantages when combined with other propulsion approaches. The representative biomedical applications of functional AcousticRobots are also highlighted, including drug delivery, invasive surgery, eradication on the surrounding bio-environment, cell manipulation, detection, and imaging, etc. We conclude by discussing the challenges and outlook of AcousticRobots in biomedical applications.


Assuntos
Sistemas de Liberação de Medicamentos , Nanotecnologia , Humanos , Nanotecnologia/métodos , Sistemas de Liberação de Medicamentos/métodos
6.
Food Chem ; 443: 138607, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38301552

RESUMO

Food crops provide a good selenium (Se) source for Se-deficient populations. This study assessed how boiling affects Se concentration, speciation, and bioaccessibility in common food crops to determine human Se intake. Boiling rice resulted in an 11.9% decrease in minimum Se content, while sorghum experienced a maximum (34.9%) reduction. Boiled vegetables showed a 21% - 40% Se loss. Cereals showed notable decreases in selenomethionine (SeMet) and selenocysteine (SeCys2), while most vegetables exhibited a significant reduction in Se-methylselenocysteine (SeMeCys). Boiling significantly reduced the Se bioaccessibility in all food crops, except cabbage and potato. Cereal crops were more efficacious in meeting the recommended daily intake (RDI) of Se compared to vegetables. Rice exceeds other crops and provides up to 39.2% of the WHO/FAO-recommended target minimum daily intake of 60 µg/day. This study provides insight into a substantial dissonance between the estimated daily intake (EDI) of Se and the bioaccessible Se in both raw and boiled crops. Consequently, revising EDI standards is imperative.


Assuntos
Selênio , Humanos , Selenometionina/análise , Produtos Agrícolas , Grão Comestível/química , Verduras
7.
Langmuir ; 40(6): 2815-2829, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38301280

RESUMO

The increasing health risks posed by per- and polyfluoroalkyl substances (PFASs) in the environment highlight the importance of implementing effective removal techniques. Conventional wastewater treatment processes are inadequate for removing persistent organic pollutants. Recent studies have increasingly demonstrated that metal-organic frameworks (MOFs) are capable of removing PFASs from water through adsorption techniques. However, there is still constructive discussion on the potential of MOFs in adsorbing and removing PFASs for large-scale engineering applications. This review systematically investigates the use of MOFs as adsorbents for the removal of PFAS in water treatment. This primarily involved a comprehensive analysis of existing literature to understand the adsorption mechanisms of MOFs and to identify factors that enhance their efficiency in removing PFASs. We also explore the critical aspects of regeneration and stability of MOFs, assessing their reusability and long-term performance, which are essential for large-scale water treatment applications. Finally, our study highlights the challenges of removing PFASs using MOFs. Especially, the efficient removal of short-chain PFASs with hydrophilicity is a major challenge, while medium- to long-chain PFASs are frequently susceptible to being captured from water by MOFs through multiple synergistic effects. The ion-exchange force may be the key to solving this difficulty, but its susceptibility to ion interference in water needs to be addressed in practical applications. We hope that this review can provide valuable insights into the effective removal and adsorption mechanisms of PFASs as well as advance the sustainable utilization of MOFs in the field of water treatment, thereby presenting a novel perspective.

8.
Adv Mater ; 36(7): e2306583, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37713652

RESUMO

Brain diseases, such as brain tumors, neurodegenerative diseases, cerebrovascular diseases, and brain injuries, are caused by various pathophysiological changes, which pose a serious health threat. Brain disorders are often difficult to treat due to the presence of the blood-brain barrier (BBB). Biomimetic nanovesicles (BNVs), including endogenous extracellular vesicles (EVs) derived from various cells and artificial nanovesicles, possess the ability to penetrate the BBB and thus can be utilized for drug delivery to the brain. BNVs, especially endogenous EVs, are widely distributed in body fluids and usually carry various disease-related signal molecules such as proteins, RNA, and DNA, and may also be analyzed to understand the etiology and pathogenesis of brain diseases. This review covers the exhaustive classification and characterization of BNVs and pathophysiological roles involved in various brain diseases, and emphatically focuses on nanotechnology-integrated BNVs for brain disease theranostics, including various diagnosis strategies and precise therapeutic regulations (e.g., immunity regulation, disordered protein clearance, anti-neuroinflammation, neuroregeneration, angiogenesis, and the gut-brain axis regulation). The remaining challenges and future perspectives regarding the nanotechnology-integrated BNVs for the diagnosis and treatment of brain diseases are also discussed and outlined.


Assuntos
Biomimética , Neoplasias Encefálicas , Humanos , Encéfalo/metabolismo , Barreira Hematoencefálica/metabolismo , Neoplasias Encefálicas/metabolismo , Sistemas de Liberação de Medicamentos
9.
Front Oncol ; 13: 1197447, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37333814

RESUMO

Ultrasound elastography (USE) provides complementary information of tissue stiffness and elasticity to conventional ultrasound imaging. It is noninvasive and free of radiation, and has become a valuable tool to improve diagnostic performance with conventional ultrasound imaging. However, the diagnostic accuracy will be reduced due to high operator-dependence and intra- and inter-observer variability in visual observations of radiologists. Artificial intelligence (AI) has great potential to perform automatic medical image analysis tasks to provide a more objective, accurate and intelligent diagnosis. More recently, the enhanced diagnostic performance of AI applied to USE have been demonstrated for various disease evaluations. This review provides an overview of the basic concepts of USE and AI techniques for clinical radiologists and then introduces the applications of AI in USE imaging that focus on the following anatomical sites: liver, breast, thyroid and other organs for lesion detection and segmentation, machine learning (ML) - assisted classification and prognosis prediction. In addition, the existing challenges and future trends of AI in USE are also discussed.

10.
Endosc Ultrasound ; 11(4): 252-274, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35532576

RESUMO

Physicians have used palpation as a diagnostic examination to understand the elastic properties of pathology for a long time since they realized that tissue stiffness is closely related to its biological characteristics. US elastography provided new diagnostic information about elasticity comparing with the morphological feathers of traditional US, and thus expanded the scope of the application in clinic. US elastography is now widely used in the field of diagnosis and differential diagnosis of abnormality, evaluating the degree of fibrosis and assessment of treatment response for a range of diseases. The World Federation of Ultrasound Medicine and Biology divided elastographic techniques into strain elastography (SE), transient elastography and acoustic radiation force impulse (ARFI). The ARFI techniques can be further classified into point shear wave elastography (SWE), 2D SWE, and 3D SWE techniques. The SE measures the strain, while the shear wave-based techniques (including TE and ARFI techniques) measure the speed of shear waves in tissues. In this review, we discuss the various techniques separately based on their basic principles, clinical applications in various organs, and advantages and limitations and which might be most appropriate given that the majority of doctors have access to only one kind of machine.

11.
Se Pu ; 40(4): 323-332, 2022 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-35362680

RESUMO

Nonsteroidal anti-inflammatory drugs (NSAIDs) are a class of synthetic drugs that do not contain glucocorticoids. NSAIDs are widely used for their analgesic, antipyretic, and anti-inflammatory effects. Due to their low adsorption coefficients and recalcitrance to biodegradation, NSAIDs readily enter environmental water through sewage discharge and exist stably for long periods. The long-term presence of trace amounts of NSAIDs in environmental water has adverse health effects on humans and animals. Therefore, it is important to establish an appropriately sensitive and reliable method for the determination of NSAIDs in environmental water, where their concentrations are low. Ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) is highly selective and sensitive, and so is especially suitable for detection of NSAIDs. Solid phase extraction is one of the most commonly used pretreatment methods. The extraction efficiency depends mainly on the adsorbents used. Metal-organic framework (MOF) aerogel SPE materials combine the attributes of highly selective adsorption property and high affinity. Moreover, the monolithic structure of the MOF aerogel composite simplifies the solid-liquid separation process. In this work, a novel MOF/chitosan (CS) composite designated Co-UiO-67(bpy)/CS, was prepared as the adsorbent material to enrich ketoprofen (KPF), naproxen (NPX), flurbiprofen (FPN), diclofenac (DCF), and ibuprofen (IBF) in water. This facilitated the detection of these compounds by UPLC-MS/MS. Co-UiO-67(bpy) was synthesized by a solvothermal method by mixing zirconium chloride, cobalt chloride, and the organic ligand 2,2-bipyridine-5,5 dicarboxylic acid. A CS suspension was used to prepared the hydrogel, which was freeze-dried to obtain the Co-UiO-67(bpy)/CS aerogel. The prepared material was characterized by Fourier transform-infrared spectroscopy (FT-IR) and scanning electron microscopy (SEM). Co-UiO-67 (bpy) was embedded into chitosan. A layered porous MOF composite aerogel was observed. The extraction efficiency of the five NSAIDs was investigated and optimized by assessing type of extraction material, MOF amount, extraction time, sample pH, ionic strength, formic acid concentration in eluent, elution time, and elution volume. The optimized results showed that the target compounds could be completely adsorbed within 5 min. In the UPLC-MS/MS experiment, NSAIDs were analyzed in the negative ionization multiple radiation monitoring (MRM) mode. Gradient elution was carried out with 0.01% formic acid aqueous solution and methanol as the mobile phases. The analytical method was established in the optimized extraction conditions. The five NSAIDs displayed good linearity with linear correlation coefficients greater than 0.9937. The limits of detection (LODs) and limits of quantification (LOQs) of this developed method were 0.32-2.06 ng/L and 1.05-6.78 ng/L, respectively. Satisfactory recoveries of the five analytes were achieved within 74.5%-114.1% at three spiked concentrations of 40, 250, and 1500 ng/L, as well as good precision with relative standard deviations of 1.3%-12.3% (intra-day) and 1.3%-11.5% (inter-day). The method was then used to test real-world water samples. Trace amounts of ketoprofen and flurbiprofen were detected in municipal wastewater (14.52 ng/L and 10.05 ng/L, respectively). The method exhibited good sensitivity, accuracy, and precision, and the operation process was convenient. The present study thus presents a novel method for the detection of the trace NSAIDs in environmental waters.


Assuntos
Estruturas Metalorgânicas , Animais , Anti-Inflamatórios não Esteroides , Cromatografia Líquida , Extração em Fase Sólida , Espectroscopia de Infravermelho com Transformada de Fourier , Espectrometria de Massas em Tandem , Água
12.
Eur Radiol ; 32(6): 4046-4055, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35066633

RESUMO

OBJECTIVES: To evaluate the diagnostic value of computer-aided diagnosis (CAD) software on ultrasound in distinguishing benign and malignant breast masses and avoiding unnecessary biopsy. METHODS: This prospective, multicenter study included patients who were scheduled for pathological diagnosis of breast masses between April 2019 and November 2020. Ultrasound images, videos, CAD analysis, and BI-RADS were obtained. The AUC, accuracy, sensitivity, specificity, PPV, and NPV were calculated and compared with radiologists. RESULTS: Overall, 901 breast masses in 901 patients were enrolled in this study. The accuracy, sensitivity, specificity, PPV and NPV of CAD software were 89.6%, 94.2%, 87.0%, 80.4%, and 96.3, respectively, in the long-axis section; 89.0%, 91.4%, 87.7%, 80.8%, and 94.7%, respectively, in the short-axis section. With BI-RADS 4a as the cut-off value, CAD software has a higher AUC (0.906 vs 0.734 vs 0.696, all p < 0.001) than both experienced and less experienced radiologists. With BI-RADS 4b as the cut-off value, CAD software showed better AUC than less experienced radiologists (0.906 vs 0.874, p < 0.001), but not superior to experienced radiologists (0.906 vs 0.883, p = 0.057). After the application of CAD software, the unnecessary biopsy rate of BI-RADS categories 4 and 5 was significantly decreased (33.0% vs 11.9%, 37.8% vs 14.5%), and the malignant rate of biopsy in category 4a was significantly increased (11.6% vs 40.7%, 7.4% vs 34.9%, all p < 0.001). CONCLUSIONS: CAD software on ultrasound can be used as an effective auxiliary diagnostic tool for differential diagnosis of benign and malignant breast masses and reducing unnecessary biopsy. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov (NCT03887598) KEY POINTS: • Prospective multicenter study showed that computer-aided diagnosis software provides greater diagnostic confidence for differentiating benign and malignant breast masses. • Computer-aided diagnosis software can help radiologists reduce unnecessary biopsy. • The management of patients with breast masses becomes more appropriate.


Assuntos
Neoplasias da Mama , Mama , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Computadores , Diagnóstico por Computador/métodos , Feminino , Humanos , Estudos Prospectivos , Sensibilidade e Especificidade , Ultrassonografia Mamária/métodos
13.
J Hazard Mater ; 429: 128333, 2022 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-35093751

RESUMO

Global concerns stem from the environmental crisis have compelled researchers to develop selective and sensitive methods for the identification and measurement of emerging pollutants in the environmental matrices. The cationic F-TMU-66+Cl-/polyvinylidene fluoride metal-organic frameworks (MOFs) mixed matrix membrane (F-TMU-66+Cl-/PVDF MMM) was synthesized and used as a versatile adsorbent with multiple binding sites for the simultaneous extraction of twelve anionic perfluorinated compounds (PFCs) from reservoir water samples. The physical and chemical characteristics of the materials, as well as adsorption mechanism were fully surveyed by various instrumental techniques. Important extraction parameters, including amount of MOFs, pH, desorption conditions, and salinity were systematically investigated and optimized. The combination of dispersive membrane solid extraction based on F-TMU-66+Cl-/PVDF MMM with ultra-high performance liquid chromatography-tandem mass spectrometry provided ultra-low limit of detections within the range of 0.03-0.48 ng/L. By virtue of the simplicity and robustness of the extraction procedure, high sensitivity of detection scheme, good stability and selectivity of the F-TMU-66+Cl-/PVDF MMM, the developed method exhibits excellent practicability for ultra-trace analysis of anionic PFCs in water samples.


Assuntos
Estruturas Metalorgânicas , Poluentes Químicos da Água , Adsorção , Cromatografia Líquida de Alta Pressão/métodos , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Água , Poluentes Químicos da Água/análise
14.
J Hazard Mater ; 424(Pt D): 127687, 2022 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-34776299

RESUMO

A simple method based on magnetic solid-phase extraction (MSPE) was developed for the simultaneous extraction of eleven emerging aromatic disinfection byproducts (DBPs) in water samples coupled with ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) determination. A magnetic covalent-organic framework (COF) material, namely, Fe3O4 @TpBD, was facilely synthesized and fully characterized, followed by an MSPE process. Several important MSPE parameters, such as the magnetic ratio, Fe3O4 @TpBD amount and sample pH, were systematically investigated. Under optimal conditions, the limits of detection and quantification of this COF-MSPE-UHPLC-MS/MS method were as low as 0.07-1.81 ng/L and 0.24-5.99 ng/L, respectively. Good precision was obtained with relative standard deviations (RSDs) of 1.3-10.9% (intraday) and 4.3-15.9% (interday). Furthermore, the validated method was proven applicable to real water samples; for example, the recoveries were 86.8-115.1% for the secondary effluent, and several DBPs in swimming pool water were detected. Notably, the MSPE process required only 7 min, ensuring that the DBPs were relatively stable during the whole analysis process and that Fe3O4 @TpBD demonstrated excellent reusability. The COF-based MSPE method with simplicity, rapidity and efficiency provided an ideal sample pretreatment alternative to determine trace DBPs in complex matrices.


Assuntos
Estruturas Metalorgânicas , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão , Desinfecção , Limite de Detecção , Fenômenos Magnéticos , Extração em Fase Sólida , Água
15.
Artigo em Inglês | MEDLINE | ID: mdl-36613038

RESUMO

Metal organic framework based mixed matrix membranes (MOF-MMMs) were synthesized and applied for dispersive membrane extraction (DME) of four neonicotinoid insecticides (nitenpyram, thiacloprid, imidacloprid, and acetamiprid) in environmental water, combined with high performance liquid chromatography (HPLC) for determination. Several experimental conditions were optimized in detail, involving dosage percentage of MOF, extraction time, sample pH, salinity, type and volume of eluent, and elution time. High sensitivity with limits of detection and quantification were achieved as 0.013-0.064 µg L-1 and 0.038-0.190 µg L-1, respectively, and good precision with relative standard deviations were obtained as 3.07-12.78%. The proposed method has been successfully applied to determine four neonicotinoid insecticides in tap water, surface water, and seawater, satisfactory recoveries of spiked water samples were between 72.50 and 117.98%. Additionally, the MOF-MMMs showed good reusability with the extraction efficiencies almost remaining stable after 14 cycles. The MOF-MMMs based DME followed by the HPLC method can be a promising utility for the determination of neonicotinoid insecticides in environmental water samples, with high sensitivity and convenient operation.


Assuntos
Inseticidas , Inseticidas/análise , Cromatografia Líquida de Alta Pressão/métodos , Água/química , Neonicotinoides/análise , Água do Mar , Extração em Fase Sólida/métodos
16.
Front Oncol ; 11: 779612, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34858859

RESUMO

OBJECTIVE: This study aimed to explore the value of elasticity score (ES) and strain ratio (SR) combined with conventional ultrasound in distinguishing benign and malignant breast masses and reducing biopsy of BI-RADS (Breast Imaging Reporting and Data System) 4a lesions. METHODS: This prospective, multicenter study included 910 patients from nine different hospitals. The acquisition and analysis of conventional ultrasound and strain elastography (SE) were obtained by radiologists with more than 5 years of experience in breast ultrasound imaging. The diagnostic sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under curve (AUC) of conventional ultrasound alone and combined tests with ES and/or SR were calculated and compared. RESULTS: The optimal cutoff value of SR for differentiating benign from malignant masses was 2.27, with a sensitivity of 60.2% and a specificity of 84.8%. When combined with ES and SR, the AUC of the new BI-RADS classification increased from 0.733 to 0.824 (p < 0.001); the specificity increased from 48.1% to 68.5% (p < 0.001) without a decrease in the sensitivity (98.5% vs. 96.4%, p = 0.065); and the PPV increased from 52.2% to 63.7% (p < 0.001) without a loss in the NPV (98.2% vs. 97.1%, p = 0.327). All three combinations of conventional ultrasound, ES, and SR could reduce the biopsy rate of category 4a lesions without reducing the malignant rate of biopsy (from 100% to 68.3%, 34.9%, and 50.4%, respectively, all p < 0.001). CONCLUSIONS: SE can be used as a useful and non-invasive additional method to improve the diagnostic performance of conventional ultrasound by increasing AUC and specificity and reducing the unnecessary biopsy of BI-RADS 4a lesions.

17.
Front Oncol ; 11: 709339, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34557410

RESUMO

PURPOSE: This study aimed to develop a radiomics nomogram based on contrast-enhanced ultrasound (CEUS) for preoperatively assessing microvascular invasion (MVI) in hepatocellular carcinoma (HCC) patients. METHODS: A retrospective dataset of 313 HCC patients who underwent CEUS between September 20, 2016 and March 20, 2020 was enrolled in our study. The study population was randomly grouped as a primary dataset of 192 patients and a validation dataset of 121 patients. Radiomics features were extracted from the B-mode (BM), artery phase (AP), portal venous phase (PVP), and delay phase (DP) images of preoperatively acquired CEUS of each patient. After feature selection, the BM, AP, PVP, and DP radiomics scores (Rad-score) were constructed from the primary dataset. The four radiomics scores and clinical factors were used for multivariate logistic regression analysis, and a radiomics nomogram was then developed. We also built a preoperative clinical prediction model for comparison. The performance of the radiomics nomogram was evaluated via calibration, discrimination, and clinical usefulness. RESULTS: Multivariate analysis indicated that the PVP and DP Rad-score, tumor size, and AFP (alpha-fetoprotein) level were independent risk predictors associated with MVI. The radiomics nomogram incorporating these four predictors revealed a superior discrimination to the clinical model (based on tumor size and AFP level) in the primary dataset (AUC: 0.849 vs. 0.690; p < 0.001) and validation dataset (AUC: 0.788 vs. 0.661; p = 0.008), with a good calibration. Decision curve analysis also confirmed that the radiomics nomogram was clinically useful. Furthermore, the significant improvement of net reclassification index (NRI) and integrated discriminatory improvement (IDI) implied that the PVP and DP radiomics signatures may be very useful biomarkers for MVI prediction in HCC. CONCLUSION: The CEUS-based radiomics nomogram showed a favorable predictive value for the preoperative identification of MVI in HCC patients and could guide a more appropriate surgical planning.

18.
Med Sci Monit ; 27: e931957, 2021 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-34552043

RESUMO

Computer-aided diagnosis (CAD) systems have attracted extensive attention owing to their performance in the field of image diagnosis and are rapidly becoming a promising auxiliary tool in medical imaging tasks. These systems can quantitatively evaluate complex medical imaging features and achieve efficient and high-diagnostic accuracy. Deep learning is a representation learning method. As a major branch of artificial intelligence technology, it can directly process original image data by simulating the structure of the human brain neural network, thus independently completing the task of image recognition. S-Detect is a novel and interactive CAD system based on a deep learning algorithm, which has been integrated into ultrasound equipment and can help radiologists identify benign and malignant nodules, reduce physician workload, and optimize the ultrasound clinical workflow. S-Detect is becoming one of the most commonly used CAD systems for ultrasound evaluation of breast and thyroid nodules. In this review, we describe the S-Detect workflow and outline its application in breast and thyroid nodule detection. Finally, we discuss the difficulties and challenges faced by S-Detect as a precision medical tool in clinical practice and its prospects.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia/métodos , Mama/diagnóstico por imagem , Diagnóstico por Computador/métodos , Feminino , Humanos , Masculino , Sensibilidade e Especificidade , Glândula Tireoide/diagnóstico por imagem
19.
Se Pu ; 39(8): 896-904, 2021 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-34212590

RESUMO

Phenoxy acid herbicides are widely used because of their excellent efficiency and low cost. However, owing to their strong polarity and water solubility, these herbicides do not degrade easily in a water environment and persist for a long time in water bodies. These herbicides readily enter water bodies via surface runoff, infiltration, and other migration routes, thus affecting water quality safety. Therefore, it is of great significance to establish a sensitive and simple method for the quantitative analysis of phenoxy acid herbicides in environmental water. Given the low concentration of such contaminants in environmental water, appropriate detection methods are important. Ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has high sensitivity and accuracy, thus being well suited for the phenoxy acid herbicides analysis. Sample preparation techniques are also important for the extraction and enrichment of contaminants in environmental water. Dispersive solid phase extraction (DSPE) has attracted considerable attention owing to its low cost, ease of operation, and low solvent consumption. In general, the selectivity and efficiency of solid phase extraction are largely dependent on the characteristics of the solid adsorbent materials. Ionic metal-organic frameworks (iMOFs) have excellent ion-exchange properties and show selective absorptivity to ionic compounds. In this work, a metal-organic framework (MOF) MIL-101-NH2 was synthesized by a facile hydrothermal method. Then, a cationic MOF mixed matrix membrane (MMM) was fabricated by soaking the MOFs in a polyvinylidene fluoride (PVDF) solution and further functionalization with quaternary amine groups. A method was developed for the determination of seven phenoxy acid herbicides in water by UPLC-MS/MS based on DSPE. The prepared material was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy to determine its functional groups and morphology. The results showed that there were quaternary amine groups in the material, and that the functionalization did not have any obvious effect on the chemical and crystal structures of MIL-101-NH2. The prepared MIL-101-$NMe_{3}^{+}$-PVDF MMM was used as an adsorbent for DSPE to enrich the seven phenoxy acid herbicides in water. It is well known that the key factors influencing extraction efficiency are the adsorption and elution conditions. To establish the optimum extraction conditions, the influence of some important factors, including the adsorbent amount, sample pH, extraction time, elution solvent, elution volume, and elution time, was investigated in detail. Gradient elution was carried out with 0.01% formic acid aqueous solution and acetonitrile as the mobile phase. The target analytes were separated on an ACQUITY UPLC BEH C18 column (100 mm×2.1 mm, 1.7 µm), and multiple reaction monitoring (MRM) was conducted in the negative electrospray ionization mode. The external standard method was used for quantitative analysis. The established method was verified in terms of the linear ranges, limits of detection (LODs), limits of quantification (LOQs), recoveries, and precision. Under the optimal conditions, the seven phenoxy acid herbicides showed good linear relationships in their respective concentration ranges, and the correlation coefficients were all higher than 0.997. The LODs and LOQs were 0.00010-0.00090 µg/L and 0.00033-0.00300 µg/L, respectively. The recoveries were tested at three spiked levels of 0.005, 0.05, and 0.2 µg/L. The average recoveries of the seven compounds were in the range of 80% to 102%. The intra-day and inter-day relative standard deviations were within 1.4% to 9.4% and 4.2% to 12.6%, respectively. The established method was applied to the analysis of the phenoxy acid herbicides in tap water and reservoir water. Three levels of spiked samples were adopted to investigate the accuracy of the method. The results demonstrated that our method is applicable to the detection of trace phenoxy acid herbicides in water samples. In summary, this method has the advantages of simplicity, rapidity, and sensitivity, and it is suitable for the detection of the seven phenoxy acid herbicides in environmental water.

20.
Front Oncol ; 11: 575166, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33987082

RESUMO

OBJECTIVE: The purpose of this study was to improve the differentiation between malignant and benign thyroid nodules using deep learning (DL) in category 4 and 5 based on the Thyroid Imaging Reporting and Data System (TI-RADS, TR) from the American College of Radiology (ACR). DESIGN AND METHODS: From June 2, 2017 to April 23, 2019, 2082 thyroid ultrasound images from 1396 consecutive patients with confirmed pathology were retrospectively collected, of which 1289 nodules were category 4 (TR4) and 793 nodules were category 5 (TR5). Ninety percent of the B-mode ultrasound images were applied for training and validation, and the residual 10% and an independent external dataset for testing purpose by three different deep learning algorithms. RESULTS: In the independent test set, the DL algorithm of best performance got an AUC of 0.904, 0.845, 0.829 in TR4, TR5, and TR4&5, respectively. The sensitivity and specificity of the optimal model was 0.829, 0.831 on TR4, 0.846, 0.778 on TR5, 0.790, 0.779 on TR4&5, versus the radiologists of 0.686 (P=0.108), 0.766 (P=0.101), 0.677 (P=0.211), 0.750 (P=0.128), and 0.680 (P=0.023), 0.761 (P=0.530), respectively. CONCLUSIONS: The study demonstrated that DL could improve the differentiation of malignant from benign thyroid nodules and had significant potential for clinical application on TR4 and TR5.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA