Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Mater ; : e2310201, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38320746

RESUMO

The stability of long-term microfabricated implants is hindered by the presence of multiple water diffusion paths within artificially patterned thin-film encapsulations. Side permeation, defined as infiltration of molecules through the lateral surface of the thin structure, becomes increasingly critical with the trend of developing high-density and miniaturized neural electrodes. However, current permeability measurement methods do not account for side permeation accurately nor quantitatively. Here, a novel optical, magnesium (Mg)-based method is proposed to quantify the side water transmission rate (SWTR) through thin film encapsulation and validate the approach using micrometric polyimide (PI) and polyimide-silicon carbide (PI-SiC) multilayers. Through computed digital grayscale images collected with corroding Mg film microcells coated with the thin encapsulation, side and surface WTRs are quantified. A 4.5-fold ratio between side and surface permeation is observed, highlighting the crucial role of the PI-PI interface in lateral diffusion. Universal guidelines for the design of flexible, hermetic neural interfaces are proposed. Increasing encapsulation's width (interelectrode spacing), creating stronger interfacial interactions, and integrating high-barrier interlayers such as SiC significantly enhance the lateral hermeticity.

2.
IEEE Trans Biomed Circuits Syst ; 18(1): 27-38, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37527296

RESUMO

One challenge in designing RF wireless bioelectronic devices is the impact of the interaction between electromagnetic waves and host body tissues on far-field wireless performance. In this article, we investigate a peculiar phenomenon of implantable RF wireless devices within a small-scale host body related to the deformation of the directivity pattern. Radiation measurements of subcutaneously implanted antennas within rodent cadavers show that the direction of maximum radiation is not always identical with the direction to the closest body-air interface, as one would expect in larger-scale host bodies. For an implanted antenna in the back of a mouse, we observed the maximum directivity in the ventral direction with 4.6 dB greater gain compared to the nearest body-air interface direction. Analytic analysis within small-scale spherical body phantoms identifies two main factors for these results: the limited absorption losses due to the small body size relative to the operating wavelength and the high permittivity of the biological tissues of the host body. Due to these effects, the entire body acts as a dielectric resonator antenna, leading to deformations of the directivity pattern. These results are confirmed with the practical example of a wirelessly powered 2.4-GHz optogenetic implant, demonstrating the significance of the judicious placement of external antennas to take advantage of the deformation of the implanted antenna pattern. These findings emphasize the importance of carefully designing implantable RF wireless devices based on their placements and relative electrical dimensions in small-scale animal models.


Assuntos
Próteses e Implantes , Tecnologia sem Fio , Animais , Camundongos , Imagens de Fantasmas
3.
Adv Mater ; 34(34): e2201129, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35353928

RESUMO

Bioelectronic implantable systems (BIS) targeting biomedical and clinical research should combine long-term performance and biointegration in vivo. Here, recent advances in novel encapsulations to protect flexible versions of such systems from the surrounding biological environment are reviewed, focusing on material strategies and synthesis techniques. Considerable effort is put on thin-film encapsulation (TFE), and specifically organic-inorganic multilayer architectures as a flexible and conformal alternative to conventional rigid cans. TFE is in direct contact with the biological medium and thus must exhibit not only biocompatibility, inertness, and hermeticity but also mechanical robustness, conformability, and compatibility with the manufacturing of microfabricated devices. Quantitative characterization methods of the barrier and mechanical performance of the TFE are reviewed with a particular emphasis on water-vapor transmission rate through electrical, optical, or electrochemical principles. The integrability and functionalization of TFE into functional bioelectronic interfaces are also discussed. TFE represents a must-have component for the next-generation bioelectronic implants with diagnostic or therapeutic functions in human healthcare and precision medicine.


Assuntos
Técnicas Biossensoriais , Humanos , Técnicas Biossensoriais/métodos , Próteses e Implantes
4.
Small ; 17(40): e2103039, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34477315

RESUMO

Flexible and soft bioelectronics display conflicting demands on miniaturization, compliance, and reliability. Here, the authors investigate the design and performance of thin encapsulation multilayers against hermeticity and mechanical integrity. Partially cracked organic/inorganic multilayer coatings are demonstrated to display surprisingly year-long hermetic lifetime under demanding mechanical and environmental loading. The thin hermetic encapsulation is grown in a single process chamber as a continuous multilayer with dyads of atomic layer deposited (ALD) Al2 O3 -TiO2 and chemical vapor deposited Parylene C films with strong interlayer adhesion. Upon tensile loading, tortuous diffusion pathways defined along channel cracks in the ALD oxide films and through tough Parylene films efficiently postpone the hermeticity failure of the partially cracked coating. The authors assessed the coating performance against prolonged exposure to biomimetic physiological conditions using coated magnesium films, platinum interdigitated electrodes, and optoelectronic devices prepared on stretchable substrates. Designed extension of the lifetime preventing direct failures reduces from over 5 years yet tolerates the lifetime of 3 years even with the presence of critical damage, while others will directly fail less than two months at 37 °C. This strategy should accelerate progress on thin hermetic packaging for miniaturized and compliant implantable electronics.


Assuntos
Óxido de Alumínio , Próteses e Implantes , Eletrodos , Eletrônica , Reprodutibilidade dos Testes
5.
Adv Mater ; 31(6): e1806948, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30549118

RESUMO

Peeling from strong adhesion is hard, and sometimes painful. Herein, an approach is described to achieve both strong adhesion and easy detachment. The latter is triggered, on-demand, through an exposure to light of a certain frequency range. The principle of photodetachable adhesion is first demonstrated using two hydrogels as adherends. Each hydrogel has a covalent polymer network, but does not have functional groups for bonding, so that the two hydrogels by themselves adhere poorly. The two hydrogels, however, adhere strongly when an aqueous solution of polymer chains is spread on the surfaces of the hydrogels and is triggered to form a stitching polymer network in situ, in topological entanglement with the pre-existing polymer networks of the two hydrogels. The two hydrogels detach easily when the stitching polymer network is so functionalized that it undergoes a gel-sol transition in response to a UV light. For example, two pieces of alginate-polyacrylamide hydrogels achieve adhesion energies about 1400 and 10 J m-2 , respectively, before and after the UV radiation. Experiments are conducted to study the physics and chemistry of this strong and photodetachable adhesion, and to adhere and detach various materials, including hydrogels, elastomers, and inorganic solids.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...