1.
ACS Appl Mater Interfaces ; 13(39): 46537-46548, 2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34554723

RESUMO

In capacitive deionization (CDI), coion repulsion and Faradaic reactions during charging reduce the charge efficiency (CE), thus limiting the salt adsorption capacity (SAC) and energy efficiency. To overcome these issues, membrane CDI (MCDI) based on the enhanced permselectivity of the anode and cathode is proposed using the ion-exchange polymer as the independent membrane or coating. To develop a novel and cost-effective MCDI system, we fabricated an integrated membrane electrode using a thin layer of the inorganic ion-exchange material coated on the activated carbon (AC) electrode, which effectively improves the ion selectivity. Montmorillonite (MT, Al2O9Si3) and hydrotalcite (HT, Mg6Al2(CO3)(OH)16·4H2O) were selected as the main active anion- and cation-exchange materials, respectively, for the cathode and anode. The HT-MT MCDI system employing HT-AC and MT-AC electrodes obtained a CE of 90.5% and an SAC of 15.8 mg g-1 after 100 consecutive cycles (50 h); these values were considerably higher than those of the traditional CDI system employing pristine AC electrodes (initially, a CE of 55% and an SAC of 10.2 mg g-1, which attenuated continuously to zero, and even "inverted work" occurs after 50 h, i.e., desorption during charging and adsorption during discharging). The HT-MT MCDI system showed moderate tolerance to organic matters during desalination and retained 84% SAC and 89% CE after 70 cycles in 50-200 mg L-1 sodium alginate. This study demonstrates a simple and cost-effective method for fabricating high-CE electrodes for desalination with great application potential.

2.
RSC Adv ; 9(46): 26676-26684, 2019 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-35528572

RESUMO

Capacitive deionization (CDI) is a novel low-energy green desalination technology that has attracted much attention in recent years, especially for the desalination of low salinity water. One of the key issues in CDI is the electrode materials, and many efforts have been devoted to developing materials with high specific surface areas, appropriate pore distributions, and good electronic conductivity, in order to obtain a high salt adsorption capacity. In this study, chitosan was selected as a precursor for the preparation of high-performance chitosan-based activated carbon (CTS-AC) for use in CDI electrodes via pyrolysis and KOH activation. The results show that CTS-AC800 (activated at 800 °C) has the largest BET specific surface area (2727 m2 g-1), and exhibits an appropriate pore size distribution (<10 nm), nitrogen doping (2.0%) and good electronic conductivity (2.09 S cm-1). The CDI performance results show that the CTS-AC800 electrode has a saturated salt adsorption capacity of 14.12 mg g-1 in a 500 mg L-1 NaCl solution and retains 95% capacity after 150 adsorption-desorption cycles. Thus, chitosan is a promising, sustainable precursor for CDI electrode materials.

3.
J Am Soc Mass Spectrom ; 29(7): 1376-1385, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29623663

RESUMO

The performance of miniaturized ion trap mass analyzers is limited, in part, by the accuracy with which electrodes can be fabricated and positioned relative to each other. Alignment of plates in a two-plate planar LIT is ideal to characterize misalignment effects, as it represents the simplest possible case, having only six degrees of freedom (DOF) (three translational and three rotational). High-precision motorized actuators were used to vary the alignment between the two ion trap plates in five DOFs-x, y, z, pitch, and yaw. A comparison between the experiment and previous simulations shows reasonable agreement. Pitch, or the degree to which the plates are parallel along the axial direction, has the largest and sharpest impact to resolving power, with resolving power dropping noticeably with pitch misalignment of a fraction of a degree. Lateral displacement (x) and yaw (rotation of one plate, but plates remain parallel) both have a strong impact on ion ejection efficiency, but little effect on resolving power. The effects of plate spacing (y-displacement) on both resolving power and ion ejection efficiency are attributable to higher-order terms in the trapping field. Varying the DC (axial) trapping potential can elucidate the effects where more misalignments in more than one DOF affect performance. Implications of these results for miniaturized ion traps are discussed. Graphical Abstract ᅟ.

4.
Anal Chem ; 90(9): 5557-5562, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29613776

RESUMO

Mass spectrometric characterization of large biomolecules, such as intact proteins, requires the specificity afforded by ultrahigh resolution mass measurements performed at both the intact mass and product ion levels. Although the performance of time-of-flight mass analyzers is steadily increasing, the choice of mass analyzer for large biomolecules (e.g., proteins >50 kDa) is generally limited to the Fourier transform family of mass analyzers such as Orbitrap and ion cyclotron resonance (FTICR-MS), with the latter providing unmatched mass resolving power and measurement accuracy. Yet, protein analyses using FTMS are largely hindered by the low acquisition rates of spectra with ultrahigh resolving power. Frequency multiple detection schemes enable FTICR-MS to overcome this fundamental barrier and achieve resolving powers and acquisition speeds 4× greater than the limits imposed by magnetic field strength. Here we expand upon earlier work on the implementation of this technique for biomolecular characterization. We report the coupling of 21T FTICR-MS, 4X frequency multiplication, ion trapping field harmonization technology, and spectral data processing methods to achieve unprecedented acquisition rates and resolving power in mass spectrometry of large intact proteins. Isotopically resolved spectra of multiply charged ubiquitin ions were acquired using detection periods as short as 12 ms. Large proteins such as apo-transferrin (MW = 78 kDa) and monoclonal antibody (MW = 150 kDa) were isotopically resolved with detection periods of 384 and 768 ms, respectively. These results illustrate the future capability of accurate characterization of large proteins on time scales compatible with online separations.


Assuntos
Anticorpos Monoclonais/análise , Apoproteínas/análise , Transferrina/análise , Ubiquitina/análise , Animais , Bovinos , Eritrócitos/química , Análise de Fourier , Humanos , Espectrometria de Massas
5.
J Am Soc Mass Spectrom ; 28(5): 859-865, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28144897

RESUMO

A linear wire ion trap (LWIT) with both electron ionization (EI) and single photon ionization (SPI) sources was built. The SPI was provided by a vacuum ultraviolet (VUV) lamp with the ability to softly ionize organic compounds. The VUV lamp was driven by a pulse amplifier, which was controlled by a pulse generator, to avoid the detection of photons during ion detection. Sample gas was introduced through a leak valve, and the pressure in the system is shown to affect the signal-to-noise ratio and resolving power. Under optimized conditions, the limit of detection (LOD) for benzene was 80 ppbv using SPI, better than the LOD using EI (137 ppbv). System performance was demonstrated by distinguishing compounds in different classes from gasoline. Graphical Abstract ᅟ.

6.
Anal Chem ; 88(15): 7800-6, 2016 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-27373557

RESUMO

We report a linear ion trap (LIT) in which the electric field is formed by fine wires held under tension and accurately positioned using holes drilled in two end plates made of plastic. The coordinates of the hole positions were optimized in simulation. The stability diagram and mass spectra using boundary ejection were compared between simulation and experiment and good agreement was found. The mass spectra from experiments show peak widths (fwhm) in units of mass-to-charge of around 0.38 Th using a scan rate of 3830 Th/s. The limits of detection are 137 ppbv and 401 ppbv for benzene and toluene, respectively. Different sizes of the wire ion trap can be easily fabricated by drilling holes in scaled positions. Other distinguishing features, such as high ion and photon transmission, low capacitance, high tolerance to mechanical and assembly error, and low weight, are discussed.

7.
J Mass Spectrom ; 50(1): 160-4, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25601688

RESUMO

A two-step laser desorption lamp ionization source coupled to an ion trap mass spectrometer (LDLI-ITMS) has been constructed and characterized. The pulsed infrared (IR) output of an Nd:YAG laser (1064 nm) is directed to a target inside a chamber evacuated to ~15 Pa causing desorption of molecules from the target's surface. The desorbed molecules are ionized by a vacuum ultraviolet (VUV) lamp (filled with xenon, major wavelength at 148 nm). The resulting ions are stored and detected in a three-dimensional quadrupole ion trap modified from a Finnigan Mat LCQ mass spectrometer operated at a pressure of ≥ 0.004 Pa. The limit of detection for desorbed coronene molecules is 1.5 pmol, which is about two orders of magnitude more sensitive than laser desorption laser ionization mass spectrometry using a fluorine excimer laser (157 nm) as the ionization source. The mass spectrum of four standard aromatic compounds (pyrene, coronene, rubrene and 1,4,8,11,15,18,22,25-octabutoxy-29H,31H-phthalocyanine (OPC)) shows that parent ions dominate. By increasing the infrared laser power, this instrument is capable of detecting inorganic compounds.

8.
J Am Soc Mass Spectrom ; 24(7): 1116-22, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23633019

RESUMO

Measuring average quantities in complex mixtures can be challenging for mass spectrometry, as it requires ionization and detection with nearly equivalent cross-section for all components, minimal matrix effect, and suppressed signal from fragments and aggregates. Fragments and aggregates are particularly troublesome for complex mixtures, where they can be incorrectly assigned as parent ions. Here we study fragmentation and aggregation in six aromatic model compounds as well as petroleum asphaltenes (a naturally occurring complex mixture) using two laser-based ionization techniques: surface assisted laser desorption ionization (SALDI), in which a single laser desorbs and ionizes solid analytes; and laser ionization laser desorption mass spectrometry (L(2)MS), in which desorption and ionization are separated spatially and temporally with independent lasers. Model compounds studied include molecules commonly used as matrices in single laser ionization techniques such as matrix assisted laser desorption ionization (MALDI). We find significant fragmentation and aggregation in SALDI, such that individual fragment and aggregate peaks are typically more intense than the parent peak. These fragment and aggregate peaks are expected in MALDI experiments employing these compounds as matrices. On the other hand, we observe no aggregation and only minimal fragmentation in L(2)MS. These results highlight some advantages of L(2)MS for analysis of complex mixtures such as asphaltenes.

9.
Anal Chem ; 83(23): 8992-8, 2011 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22017421

RESUMO

A magnetic field enhanced photoelectron ionization (MEPEI) source combined with single photon ionization (SPI) was developed for an orthogonal acceleration time-of-flight mass spectrometer (oaTOFMS). A commercial radio frequency (rf) powered vacuum ultraviolet (VUV) lamp was used as SPI light source, and the photoelectrons generated by photoelectric effect were accelerated to induce electron ionization (EI). The MEPEI was obtained by applying a magnetic field of about 800 G with a permanent annular magnet. Compared to a nonmagnetic field photoelectron ionization source, the signal intensities for SO(2), SF(6), O(2), and N(2) in MEPEI were improved more than 2 orders with the photoelectron energy around 20 eV, while most of the characteristics of soft ionization still remained. Simulation with SIMION showed that the sensitivity enhancement in MEPEI was ascribed to the increase of the electron moving path and the improvement of the electrons transmission. The limits of detection for SO(2) and benzene were 750 and 80 ppbv within a detection time of 4 s, respectively. The advantages of the source, including broad range of ionizable compounds, reduced fragments, and good sensitivity with low energy MEPEI, were demonstrated by monitoring pyrolysis products of polyvinyl chloride (PVC) and the intermediate products in discharging of the SF(6) gas inpurity.

10.
Anal Chem ; 83(13): 5309-16, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21591696

RESUMO

A novel combined ion source based on a vacuum ultraviolet (VUV) lamp with both single photon ionization (SPI) and chemical ionization (CI) capabilities has been developed for an orthogonal acceleration time-of-flight mass spectrometer (oaTOFMS). The SPI was accomplished using a commercial 10.6 eV krypton discharge lamp with a photon flux of about 10(11) photons s(-1), while the CI was achieved through ion-molecule reactions with O(2)(+) reactant ions generated by photoelectron ionization at medium vacuum pressure (MVP). To achieve high ionization efficiency, the ion source pressure was elevated to 0.3 mbar and the photoionization length was extended to 36 mm. As a result, limits of detection (LODs) down to 3, 4, and 6 ppbv were obtained for benzene, toluene, and p-xylene in MVP-SPI mode, and values of 8 and 10 ppbv were obtained for toluene and chloroform, respectively, in SPI-CI mode. As it is feasible to switch between MVP-SPI mode and SPI-CI mode rapidly, this system is capable of monitoring complex organic mixtures with a wide range of ionization energies (IEs). The analytical capacity of this system was demonstrated by measuring dehydrogenation products of long-chain paraffins to olefins through direct capillary sampling and drinking water disinfection byproducts from chlorine through a membrane interface.

11.
Huan Jing Ke Xue ; 32(12): 3628-34, 2011 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-22468530

RESUMO

A home-made membrane inlet- single photon ionization/chemical ionization- time-of-flight mass spectrometer has been described. A vacuum ultraviolet (VUV) lamp with photon energy of 10.6 eV was used as the light source for single photon ionization (SPI). Chemical ionization (CI) was achieved through ion-molecule reactions with O2- reactant ions generated by photoelectron ionization. The two ionization modes could be rapidly switched by adjusting electric field in the ionization region within 2 s. Membrane inlet system used for rapid enrichment of volatile organic compounds (VOCs) in water was constructed by using a polydimethylsiloxane (PDMS) membrane with a thickness of 50 microm. A purge gas was added to accelerate desorption of analytes from the membrane surface. The purge gas could also help to prevent the pump oil back-streaming into the ionization region from the analyzer chamber and improve the signal to noise ratio (S/N). Achieved detection limits were 2 microg x L(-1) for methyl tert-butyl ether (MTBE) in SPI mode and 1 microg x L(-1) for chloroform in SPI-CI mode within 10 s analysis time, respectively. The instrument has been successfully applied to the rapid analysis of MTBE in simulated underground water nearby petrol station and VOCs in disinfected drinking water. The results indicate that the instrument has a great application prospect for online analysis of VOCs in water.


Assuntos
Sistemas On-Line/instrumentação , Espectrometria de Massa de Íon Secundário/instrumentação , Compostos Orgânicos Voláteis/análise , Poluentes Químicos da Água/análise , Desenho de Equipamento , Fótons , Espectrometria de Massa de Íon Secundário/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...