Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Healthc Mater ; : e2400836, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38757738

RESUMO

Implantable neural electrodes are indispensable tools for recording neuron activity, playing a crucial role in neuroscience research. However, traditional neural electrodes suffer from limited electrochemical performance, compromised biocompatibility, and tentative stability, posing great challenges for reliable long-term studies in free-moving animals. In this study, we present a novel approach employing a hybrid film composed of poly(3,4-ethylenedioxythiophene)/functional gold nanoparticles (PEDOT/3-MPA-Au) to improve the electrode-neural interface. The deposited PEDOT/3-MPA-Au demonstrates superior cathodal charge storage capacity, reduced electrochemical impedance, and remarkable electrochemical and mechanical stability. Upon implantation into the cortex of mice for a duration of 12 weeks, the modified electrodes exhibit notably decreased levels of glial fibrillary acidic protein and increased neuronal nuclei immunostaining compared to counterparts utilizing poly(3,4-ethylenedioxythiophene)/poly(styrene sulfonate). Additionally, the PEDOT/3-MPA-Au modified electrodes consistently capture high-quality, stable long-term electrophysiological signals in vivo, enabling continuous recording of target neurons for up to 16 weeks. This innovative modification strategy offers a promising solution for fabricating low-impedance, tissue-friendly, and long-term stable neural interfaces, thereby addressing the shortcomings of conventional neural electrodes. These findings mark a significant advancement towards the development of more reliable and efficacious neural interfaces, with broad implications for both research and clinical applications. This article is protected by copyright. All rights reserved.

2.
Polymers (Basel) ; 16(6)2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38543379

RESUMO

The response and mechanism of polyimide aerogel under electron irradiations were investigated. The experimental results indicated that electron irradiation could not damage the skeleton polyimide in the aerogel due to its high stability, but could result in a discharge within. The morphology of the discharge shows some dendritic discharge patterns, and the material surrounding the discharge channels was carbonized. The numerical simulation results indicated that the incident electrons, and also large amount induced secondary electrons, would be deposited inhomogeneously within the nano-porous polyimide aerogel. This would result in forming an ultra-high electrical potential of up to about 8.5 × 1010 V/m (which is far higher than the breakdown strength (2 × 108 V/m) of bulk polyimide materials) in a local region. This may be the leading cause of the obvious discharge in the materials. Furthermore, it was found that the actual reason for the discharge is related to the residual gas within the nano-porous structure; namely, the more internal residual gas (as a shorter-time vacuum pumping in the irradiated chamber), the more serious the discharge phenomenon. Correspondingly, the phenomenon may largely consist of both residual-gas discharge and surface flashover due to ultra-high local potentials induced by unevenly deposited charges in the porous aerogel.

3.
ACS Appl Mater Interfaces ; 15(35): 41310-41323, 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37590473

RESUMO

Implantable neural microelectrodes are recognized as a bridge for information exchange between inner organisms and outer devices. Combined with novel modulation technologies such as optogenetics, it offers a highly precise methodology for the dissection of brain functions. However, achieving chronically effective and stable microelectrodes to explore the electrophysiological characteristics of specific neurons in free-behaving animals continually poses great challenges. To resolve this, poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate)/poly(vinyl alcohol) (PEDOT/PSS/PVA) interpenetrating conducting polymer networks (ICPN) are fabricated via a hydrogel scaffold precoating and electrochemical polymerization process to improve the performance of neural microelectrodes. The ICPN films exhibit robust interfacial adhesion, a significantly lower electrochemical impedance, superior mechanical properties, and improved electrochemical stability compared to the pure poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate)(PEDOT/PSS) films, which may be attributed to the three-dimensional (3D) porous microstructure of the ICPN. Hippocampal neurons and rat pheochromocytoma cells (PC12 cells) adhesion on ICPN and neurite outgrowth are observed, indicating enhanced biocompatibility. Furthermore, alleviated tissue response at the electrode-neural tissue interface and improved recording signal quality are confirmed by histological and electrophysiological studies, respectively. Owing to these merits, optogenetic modulations and electrophysiological recordings are performed in vivo, and an anxiolytic effect of hippocampal glutamatergic neurons on behavior is shown. This study demonstrates the effectiveness and advantages of ICPN-modified neural implants for in vivo applications.


Assuntos
Hidrogéis , Polímeros , Animais , Ratos , Poliestirenos , Microeletrodos , Álcool de Polivinil
4.
Acta Biomater ; 157: 252-262, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36521677

RESUMO

Biomimetic brain structures and artificial neural networks have provided a simplified strategy for quantitatively investigating the complex structural and functional characteristics of highly interconnected neural networks. To achieve this, three-dimensional (3D) cell culture approaches have attracted much attention, which can mimic cell-cell interactions at the organism level and help better understand the function of specific neurons and neuronal networks than traditional two-dimensional cell culture methods. However, 3D scaffolds similar to the natural extracellular matrix to support the culturing, recording, and manipulation of neurons have long been an unresolved challenge. To resolve this, 3D hydrogel scaffolds can be fabricated via an innovative thermal treatment followed by an esterification process. A highly porous microstructure was formed within the bulk hydrogel scaffold, which showed a high porosity of 91% and a low Young's modulus of 6.11 kPa. Due to the merits of the fabricated hydrogel scaffolds, we constructed 3D neural networks and detected spontaneous action potentials in vitro. We successfully induced seizure-like waveforms in 3D cultured neurons and suppressed hyperactivated discharges by selectively activating γ-aminobutyric acid-ergic (GABAergic) interneurons. These results prove the advantages of our hydrogel scaffolds and demonstrate their application potential in the accurate dissection of neural circuits, which may help develop effective treatments for various neurological disorders. STATEMENT OF SIGNIFICANCE: While 3D cell culture approaches have attracted much attention and offer more advantages than two-dimensional cell culture methods, 3D scaffolds similar to the natural extracellular matrix to support the culturing, recording, and manipulation of neurons have long been an unresolved challenge. Herein, we developed a simplified and low-cost strategy for fabricating highly porous and cytocompatible hydrogel scaffolds for the construction of three-dimensional (3D) neural networks in vitro. The cultured 3D neural networks can mimic the in vivo connection among different neuron subgroups and help accurately dissect and manipulate the structure and function of specific neural circuits.


Assuntos
Materiais Biocompatíveis , Alicerces Teciduais , Alicerces Teciduais/química , Porosidade , Hidrogéis/farmacologia , Hidrogéis/química , Matriz Extracelular/química , Engenharia Tecidual/métodos , Impressão Tridimensional
5.
Polymers (Basel) ; 14(23)2022 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-36501571

RESUMO

In this work, we studied the influence of the geometry and degree of filling of glass dispersed particles on the optical and mechanical properties of flexible high-transmission composites, based on thermoplastic polyurethane. Glass spheres, glass flake and milling glass fiber were used as fillers. Studies of mechanical properties have shown that the introduction of any filler leads to a decrease in tensile strength and an increase in the elastic modulus of the composite material, however, with the introduction of glass flakes and milling glass fiber, a significant increase in the yield strength of the material is observed. The optical properties of composites with glass spheres decrease exponentially with an increase in the volume fraction of the filler. With an increase in the concentration of glass flakes and milling glass fiber to 10 vol.%, a sharp decrease in transmission is observed. With a further increase in concentration, the orientation of the filler along the film occurs, due to which the transmission in the visible range increases to values close to those of a pure polymer.

6.
Polymers (Basel) ; 14(17)2022 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-36080635

RESUMO

The transport behaviors of proton into nanoporous materials were investigated using different Monte Carlo simulation codes such as GEANT4, Deeper and SRIM. The results indicated that porous structure could enhance the proton scattering effects due to a higher specific surface area and more boundaries. The existence of voids can deepen and widen the proton distribution in the targets due to relatively lower apparent density. Thus, the incident protons would transport deeper and form a wider Bragg peak in the end of the range, as the target materials are in a higher porosity state and/or have a larger pore size. The existence of voids also causes the local inhomogeneity of proton/energy distribution in micro/nano scales. As compared, the commonly used SRIM code can only be used to estimate roughly the incident proton range in nanoporous materials, based on a homogeneous apparent density equivalence rule. Moreover, the estimated errors of the proton range tend to increase with the porosity. The Deeper code (designed for evaluation of radiation effects of nuclear materials) can be used to simulate the transport behaviors of protons or heavy ions in a real porous material with porosity smaller than 52.3% due to its modeling difficulty, while the GEANT4 code has shown advantages in that it is suitable and has been proven to simulate proton transportation in nanoporous materials with porosity in its full range of 0~100%. The GEANT4 simulation results are proved consistent with the experimental data, implying compatibility to deal with ion transportation into homogeneously nanoporous materials.

7.
Molecules ; 26(21)2021 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-34770975

RESUMO

Acyclovir (ACV) is an effective and selective antiviral drug, and the study of its toxicology and the use of appropriate detection techniques to control its toxicity at safe levels are extremely important for medicine efforts and human health. This review discusses the mechanism driving ACV's ability to inhibit viral coding, starting from its development and pharmacology. A comprehensive summary of the existing preparation methods and synthetic materials, such as 5-aminoimidazole-4-carboxamide, guanine and its derivatives, and other purine derivatives, is presented to elucidate the preparation of ACV in detail. In addition, it presents valuable analytical procedures for the toxicological studies of ACV, which are essential for human use and dosing. Analytical methods, including spectrophotometry, high performance liquid chromatography (HPLC), liquid chromatography/tandem mass spectrometry (LC-MS/MS), electrochemical sensors, molecularly imprinted polymers (MIPs), and flow injection-chemiluminescence (FI-CL) are also highlighted. A brief description of the characteristics of each of these methods is also presented. Finally, insight is provided for the development of ACV to drive further innovation of ACV in pharmaceutical applications. This review provides a comprehensive summary of the past life and future challenges of ACV.


Assuntos
Aciclovir/efeitos adversos , Aciclovir/análise , Antivirais/efeitos adversos , Antivirais/análise , Aciclovir/síntese química , Antivirais/síntese química , Humanos , Estrutura Molecular
8.
J Nanobiotechnology ; 18(1): 112, 2020 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-32778119

RESUMO

A method with high sensitivity, good accuracy and fast response is of ever increasing importance for the simultaneous detection of AA, DA and UA. In this paper, a simple and sensitive electrochemical sensor, which based on the polyvinylpyrrolidone (PVP)-graphene composite film modified glassy carbon electrode (PVP-GR/GCE), was presented for detecting ascorbic acid (AA), dopamine (DA) and uric acid (UA) simultaneously. The PVP-GR/GCE has excellent electrocatalytic activity for the oxidation of AA, DA and UA. The second-order derivative linear sweep voltammetry was used for the electrochemical measurements. The peak potential differences of DA-AA, DA-UA, and UA-AA (measured on the PVP-GR/GCE) were 212, 130 and 342 mV respectively. Besides, the over potential of AA, DA and UA reduced obviously, so did the peak current increase. Under the optimum conditions, the linear ranges of AA, DA and UA were 4.0 µM-1.0 mM, 0.02-100 µM, and 0.04-100 µM, respectively. The detection limits were 0.8 µM, 0.002 µM and 0.02 µM for AA, DA, and UA. The electrochemical sensor presented the advantages of high sensitivity and selectivity, excellent reproducibility and long-term stability. Furthermore, the sensor was successfully applied to the analysis of real samples.


Assuntos
Ácido Ascórbico/urina , Dopamina/urina , Técnicas Eletroquímicas/métodos , Ácido Úrico/urina , Grafite/química , Humanos , Limite de Detecção , Modelos Lineares , Povidona/química , Reprodutibilidade dos Testes
9.
J Neural Eng ; 17(2): 026001, 2020 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-32000145

RESUMO

OBJECTIVES: With the rapid development of EEG-based wearable healthcare devices and brain-computer interfaces, reliable and user-friendly EEG sensors for EEG recording, especially at forehead sites, are highly desirable and challenging. However, existing EEG sensors cannot meet the requirements, since wet electrodes require tedious setup and conductive pastes or gels, and most dry electrodes show unacceptable high contact impedance. In addition, the existing electrodes cannot absorb sweat effectively; sweat would cause cross-interferences, and even short circuits, between adjacent electrodes, especially in the moving scenarios, or a hot and humid environment. To resolve these problems, a novel printable flexible Ag/AgCl dry electrode array was developed for EEG acquisition at forehead sites, mainly consisting of screen printing the Ag/AgCl coating, conductive sweat-absorbable sponges and flexible tines. APPROACH: A systematic method was also established to evaluate the flexible dry electrode array. MAIN RESULTS: The experimental results show the flexible dry electrode array has reproducible electrode potential, relatively low electrode-skin impedance, and good stability. Moreover, the EEG signals can be effectively captured with a high quality that is comparable to that of wet electrodes. SIGNIFICANCE: All the results confirmed the feasibility of forehead EEG recording in real-world scenarios using the proposed flexible dry electrode array, with a rapid and facile operation as well as the advantages of self-application, user-friendliness and wearer comfort.


Assuntos
Interfaces Cérebro-Computador , Prata , Impedância Elétrica , Eletrodos , Eletroencefalografia , Testa
10.
Biomolecules ; 10(1)2020 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-31936417

RESUMO

A novel tantalum pentoxide nanoparticle-electrochemically reduced graphene oxide nanocomposite-modified glassy carbon electrode (Ta2O5-ErGO/GCE) was developed for the detection of oxytetracycline in milk. The composition, structure and morphology of GO, Ta2O5, and Ta2O5-ErGO were characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM). Oxytetracycline electrochemical behavior on the bare GCE, GO/GCE, ErGO/GCE, and Ta2O5-ErGO/GCE was studied by cyclic voltammetry. The voltammetric conditions (including scan rate, pH, deposition potential, and deposition time) were systematically optimized. With the spacious electrochemical active area, the Ta2O5-ErGO/GCE showed a great magnification of the oxidation signal of oxytetracycline, while that of the other electrodes (GCE, GO/GCE, ErGO/GCE) could not reach the same level. Under the optimum conditions, the currents were proportional to the oxytetracycline concentration in the range from 0.2 to 10 µM, and a low detection limit of 0.095 µM (S/N = 3) was detectable. Moreover, the proposed Ta2O5-ErGO/GCE performed practically with satisfactory results. The preparation of Ta2O5-ErGO/GCE in the current work provides a minor outlook of detecting trace oxytetracycline in milk.


Assuntos
Antibacterianos/análise , Grafite/química , Nanopartículas/química , Óxidos/química , Oxitetraciclina/análise , Tantálio/química , Animais , Técnicas Eletroquímicas/métodos , Análise de Alimentos/métodos , Limite de Detecção , Leite/química , Nanopartículas/ultraestrutura
11.
Nanomaterials (Basel) ; 10(1)2020 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-31936567

RESUMO

In this paper, an electrochemical method for the measurement of tryptophan (Trp) was developed based on a glassy carbon electrode modified with polyvinylpyrrolidonefunctionalized graphene (PVP-GR)/glassy carbon electrode (GCE). In 0.1 M phosphate buffer solution (PBS, pH = 2.2), compared with bare GCE, PVP/GCE, and GR/GCE, the oxidation peak current of Trp increased dramatically at PVP-GR/GCE. The oxidation mechanism of Trp on the PVP-GR/GCE was discussed and the experimental conditions were optimized. Under the best experimental conditions, the oxidation peak current of Trp was proportional to its concentration in the range of 0.06 µM-10.0 µM and 10.0-100.0 µM, and the limit of detection (LOD) was 0.01 µM (S/N = 3). The target modified electrode with excellent repeatability, stability and selectivity, was successfully applied to detectTrp in drugs and biological samples.

12.
Bioelectrochemistry ; 131: 107393, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31698180

RESUMO

A tryptophan (Trp) molecularly imprinted electrochemical sensor was fabricated by drop-coating an imprinted chitosan film on the surface of a glassy carbon electrode modified with multi-walled carbon nanotubes (MIP-MWCNTs/GCE). The surface morphology and electrochemical properties of the MIP-MWCNTs/GCE were characterized by scanning electron microscopy (SEM) and cyclic voltammetry (CV), respectively. The formation of hydrogen bonds between the functional polymer and the template molecule was confirmed by infrared spectroscopy. The electrochemical performance of the MIP-MWCNTs/GCE with Trp showed that the signal of the oxidation current of Trp obtained with MIP-MWCNTs/GCE was significantly enhanced relative to that of the uncovered GCE, indicating that the modified electrode can accelerate electron transfer and has strong selectivity for Trp. The experimental conditions were optimized in parallel, and under the optimal conditions, the MIP-MWCNTs/GCE showed a good linear relationship between the Trp oxidation peak current and Trp concentrations in the ranges of 2.0 nM-0.2 µM, 0.2 µM-10 µM and 10 µM-100 µM The limit of detection (LOD) was 1.0 nM (S/N = 3), and the modified electrode had good reproducibility and stability. Finally, the MIP-MWCNTs/GCE was successfully applied to the determination of Trp in the human serum samples.


Assuntos
Carbono/química , Eletrodos , Impressão Molecular , Nanotubos de Carbono/química , Triptofano/análise , Técnicas Eletroquímicas/métodos , Reprodutibilidade dos Testes , Espectroscopia de Infravermelho com Transformada de Fourier
13.
Nanomaterials (Basel) ; 9(10)2019 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-31640135

RESUMO

For the enhancement of the anticorrosion and antibacterial performance of the biomedical alloy Ti6Al4V, a novel Cu incorporated multilayer Ta2O5ceramic composite coating Cu-Ta2O5/Ta2O5/Ta2O5-TiO2/TiO2/Ti (coating codeCu-MTa2O5) was developed by radio frequency (RF) and direct current (DC) reactive magnetron sputtering. Meanwhile, to better display the multilayer Ta2O5 coating mentioned above, a monolayer Ta2O5 ceramic coating was deposited onto the surface of Ti6Al4V alloy as a reference. The surface morphology, microstructure, phase constituents, and elemental states of the coating were evaluated by atomic force microscopy, scanning electron microscopy, X-ray diffraction, and X-ray photoelectron spectroscopy, respectively. The adhesion strength, wettability, anticorrosion and antibacterial properties of the coating were examined by a scratch tester, contact angle measurement, electrochemical workstations, and plate counting method, respectively. The results showed that the deposited coatings were amorphous and hydrophobic. Cu doped into the Ta2O5 coating existed as CuO and Cu2O. A Ta2O5-TiO2/TiO2/Ti multi-interlayer massively enhanced the adhesion strength of the coating, which was 2.9 times stronger than that of the monolayer Ta2O5coating. The multilayer Cu-MTa2O5 coating revealed a higher corrosion potential and smaller corrosion current density as compared to the uncoated Ti6Al4V, indicating the better anticorrosion performance of Ti6Al4V. Moreover, a 99.8% antibacterial effect of Cu-MTa2O5 coated against Staphylococcus aureuswas obtained.

14.
Biomolecules ; 9(7)2019 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-31336671

RESUMO

In this paper, a tryptophan (Trp) molecularly imprinted chitosan film was prepared on the surface of an acetylene black paste electrode using chitosan as the functional polymer, Trp as the template molecule and sulfuric acid as the crosslinking agent. The surface morphologies of non-imprinted and imprinted electrodes were characterized by scanning electron microscopy (SEM). The formation of hydrogen bonds between the functional polymer and the template molecule was confirmed by infrared spectroscopy. Some factors affecting the performance of the imprinted electrode such as the concentration of chitosan, the mass ratio of chitosan to Trp, the dropping amount of the chitosan-Trp mixture, the solution pH, and the accumulation potential and time were discussed. The experimental results show that the imprinted electrode exhibit good affinity and selectivity for Trp. The dynamic linear ranges of 0.01-4 M, 4-20 M and 20-100 M were obtained by second derivative linear sweep voltammetry, and the detection limit was calculated to be 8.0 nM. The use of the imprinted electrode provides an effective method for eliminating the interference of potentially interfering substances. In addition, the sensor has high sensitivity, reproducibility and stability, and can be used for the determination of Trp in pharmaceutical preparations and human serum samples.


Assuntos
Quitosana/química , Impressão Molecular/métodos , Polímeros/química , Triptofano/química
15.
Nanomaterials (Basel) ; 9(7)2019 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-31262035

RESUMO

In this paper, the preparation, characterization, and electrochemical application of Cu2O nanoparticles and an electrochemical reduced graphene oxide nanohybrid modified glassy carbon electrode (denoted as Cu2O NPs‒ERGO/GCE) are described. This modified electrode was used as an electrochemical sensor for the catalytic oxidation of rhodamine B (RhB), and it exhibited an excellent electrochemical performance for RhB. The oxidation potential of RhB was decreased greatly, and the sensitivity to detect RhB was improved significantly. Under optimum conditions, a linear dynamic range of 0.01-20.0 µM and a low detection limit of 0.006 µM were obtained with the Cu2O NPs‒ERGO/GCE by using second‒order derivative linear sweep voltammetry. In addition, the selectivity of the prepared modified electrode was analyzed for the determination of RhB. The practical application of this sensor was investigated for the determination of RhB in food samples, and satisfactory results were obtained.

16.
Nanomaterials (Basel) ; 9(6)2019 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-31142057

RESUMO

l-tryptophan is one of the eight kinds of essential amino acids for sustainable human life activity. It is common to detect the concentration of tryptophan in human serum for diagnosing and preventing brain related diseases. Herein, in this study, GCE (glassy carbon electrode) modified by Ta2O5-reduced graphene oxide (-rGO) composite (Ta2O5-rGO-GCE) is synthesized by the hydrothermal synthesis-calcination methods, which is used for detecting the concentration of tryptophan in human serum under the as-obtained optimal detection conditions. As a result, the obtained Ta2O5-rGO-GCE shows larger electrochemical activity area than other bare GCE and rGO-GCE due to the synergistic effect of Ta2O5 NPs and rGO. Meanwhile, Ta2O5-rGO-GCE shows an excellent response to tryptophan during the oxidation process in 0.1 M phosphate buffer solution (pH = 6). Moreover, three wide linear detection range (1.0-8.0 µM, 8.0-80 µM and 80-800 µM) and a low limit of detection (LOD) of 0.84 µM (S/N = 3) in the detection of tryptophan are also presented, showing the larger linear ranges and lower detection limit by employing Ta2O5-rGO-GCE. Finally, the as-proposed Ta2O5-rGO-GCE with satisfactory recoveries (101~106%) is successfully realized for the detection of tryptophan in human serum. The synthesis of Ta2O5-rGO-GCE in this article could provide a slight view for the synthesis of other electrochemical catalytic systems in detection of trace substance in human serum.

17.
Biomolecules ; 9(5)2019 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-31072043

RESUMO

In this paper, a nanocomposite of cuprous oxide and electrochemically reduced graphene oxide (Cu2O‒ERGO) was prepared by a simple and low-cost method; hereby, a new method for the electrochemical determination of tryptophan (Trp) by this composite modified glassy carbon electrode (GCE) is proposed. The prepared materials and modified electrodes were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), and cyclic voltammetry (CV). The results showed that Cu2O‒ERGO/GCE had good electrocatalytic activity for Trp. The effects of supporting electrolyte, scanning rate, accumulation potential, and accumulation time on the determination of Trp were studied. Under the optimum experimental conditions, Trp was quantitatively analyzed by square-wave voltammetry (SWV). The oxidation peak current of Trp had a good linear relationship with its concentration in the range of 0.02‒20 µM, and the detection limit was 0.01 µM (S/N = 3). In addition, the modified electrode has high sensitivity, good repeatability, and long-term stability. Finally, the proposed method has been successfully applied in the determination of Trp concentration in practical samples.


Assuntos
Cobre/química , Eletroquímica/métodos , Grafite/química , Nanocompostos/química , Nanopartículas/química , Triptofano/análise , Calibragem , Eletrodos , Humanos , Limite de Detecção , Nanopartículas/ultraestrutura , Oxirredução , Reprodutibilidade dos Testes , Ácidos Sulfúricos/química , Triptofano/sangue , Difração de Raios X
18.
Molecules ; 24(6)2019 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-30934654

RESUMO

The nanohybrid of electrochemically-reduced graphene oxide (ERGO) nanosheets decorated with MnO2 nanorods (MnO2 NRs) was modified on the surface of a glassy carbon electrode (GCE). Controlled potential reduction was applied for the reduction of graphene oxide (GO). The characterization was performed by scanning electron microscopy, X-ray diffraction and cyclic voltammetry. Compared with the poor electrochemical response at bare GCE, a well-defined oxidation peak of sunset yellow (SY) was observed at the MnO2 NRs-ERGO/GCE, which was attributed to the high accumulation efficiency as well as considerable electrocatalytic activity of ERGO and MnO2 NRs on the electrode surface. The experimental parameters for SY detection were optimized in detail. Under the optimized experiment conditions, the MnO2 NRs-ERGO/GCE showed good linear response to SY in concentration range of 0.01⁻2.0 µM, 2.0⁻10.0 µM and 10.0⁻100.0 µM with a detection limit of 2.0 nM. This developed method was applied for SY detection in soft drinks with satisfied detected results.


Assuntos
Técnicas Eletroquímicas , Eletrodos , Corantes de Alimentos/análise , Grafite/química , Compostos de Manganês/química , Nanotubos/química , Óxidos/química , Concentração de Íons de Hidrogênio , Nanotubos/ultraestrutura , Reprodutibilidade dos Testes , Análise Espectral
19.
Nanomaterials (Basel) ; 9(3)2019 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-30871263

RESUMO

4-nitrophenol (4-NP) is a hazardous waste and a priority toxic pollutant identified by US Environmental Protection Agency (EPA). Hence, in this paper, a voltammetric sensor was proposed for the direct and sensitive detection of 4-nitrophenol (4-NP) at nanomolar level in complex matrices by using graphene and acetylene black paste hybridized electrode (GR/ABPE). Under optimal conditions, the calibration curve demonstrates a linear relationship for 4-NP in the range from 20 nM to 8.0 µM and 8.0 µM to 0.1 mM separately with the detection limit of 8.0 nM. In addition to it, the performance of the GR/ABPE in practical applications was evaluated by detecting 4-NP in various water samples, and satisfactory recoveries were realized. Therefore, GR/ABPE may have a great potential application for facile and sensitive detection of 4-NP in complex matrices at nanomolar level.

20.
Nanomaterials (Basel) ; 9(1)2019 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-30669370

RESUMO

A new electrochemical sensor for nanomolar rutin detection based on amine-functionalized Fe3O4 nanoparticles and electrochemically reduced graphene oxide nanocomposite modified glassy carbon electrode (NH2-Fe3O4 NPs-ErGO/GCE) was fabricated through a simple method, and the X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), scanning electron microscope (SEM), transmission electron microscope (TEM), vibrating sample magnetometer (VSM) and electrochemical technique were used to characterize the modified electrode. The electrochemical behavior of rutin on the Fe3O4 NPs-ErGO/GCE was studied in detail. The electrochemical response of rutin at this modified electrode was remarkably higher than that of the bare GCE or other modified GCE (GO/GCE, Fe3O4 NPs-GO/GCE, and ErGO/GCE). Under the optimum determination conditions, Fe3O4 NPs-ErGO/GCE provided rutin with a broader detection range of 6.0 nM⁻0.1 µM; 0.1⁻8.0 µM and 8.0⁻80 µM, a minimum detectable concentration of 4.0 nM was obtained after 210 s accumulation. This novel method was applied in determination of rutin in pharmaceutical tablets and urine samples with satisfactory results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...