Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Diagnostics (Basel) ; 14(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38535076

RESUMO

BACKGROUND AND AIMS: Endoscopic retrograde cholangiopancreatography (ERCP) procedures can result in significant patient radiation exposure. This retrospective multicenter study aimed to assess the influence of procedural complexity and other clinical factors on radiation exposure in ERCP. METHODS: Data on kerma-area product (KAP), air-kerma at the reference point (Ka,r), fluoroscopy time, and the number of exposures, and relevant patient, procedure, and operator factors were collected from 2641 ERCP procedures performed at four university hospitals. The influence of procedural complexity, assessed using the American Society for Gastrointestinal Endoscopy (ASGE) and HOUSE complexity grading scales, on radiation exposure quantities was analyzed within each center. The procedures were categorized into two groups based on ERCP indications: primary sclerosing cholangitis (PSC) and other ERCPs. RESULTS: Both the ASGE and HOUSE complexity grading scales had a significant impact on radiation exposure quantities. Remarkably, there was up to a 50-fold difference in dose quantities observed across the participating centers. For non-PSC ERCP procedures, the median KAP ranged from 0.9 to 64.4 Gy·cm2 among the centers. The individual endoscopist also had a substantial influence on radiation dose. CONCLUSIONS: Procedural complexity grading in ERCP significantly affects radiation exposure. Higher procedural complexity is typically associated with increased patient radiation dose. The ASGE complexity grading scale demonstrated greater sensitivity to changes in radiation exposure compared to the HOUSE grading scale. Additionally, significant variations in dose indices, fluoroscopy times, and number of exposures were observed across the participating centers.

2.
Diagnostics (Basel) ; 12(7)2022 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-35885608

RESUMO

(1) Background: Villous atrophy is an indication for small bowel capsule endoscopy (SBCE). However, SBCE findings are not described uniformly and atrophic features are sometimes not recognized; (2) Methods: The Delphi technique was employed to reach agreement among a panel of SBCE experts. The nomenclature and definitions of SBCE lesions suggesting the presence of atrophy were decided in a core group of 10 experts. Four images of each lesion were chosen from a large SBCE database and agreement on the correspondence between the picture and the definition was evaluated using the Delphi method in a broadened group of 36 experts. All images corresponded to histologically proven mucosal atrophy; (3) Results: Four types of atrophic lesions were identified: mosaicism, scalloping, folds reduction, and granular mucosa. The core group succeeded in reaching agreement on the nomenclature and the descriptions of these items. Consensus in matching the agreed definitions for the proposed set of images was met for mosaicism (88.9% in the first round), scalloping (97.2% in the first round), and folds reduction (94.4% in the first round), but granular mucosa failed to achieve consensus (75.0% in the third round); (4) Conclusions: Consensus among SBCE experts on atrophic lesions was met for the first time. Mosaicism, scalloping, and folds reduction are the most reliable signs, while the description of granular mucosa remains uncertain.

3.
Gastrointest Endosc ; 94(3): 589-597.e1, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33848508

RESUMO

BACKGROUND AND AIMS: Little is known about small-bowel (SB) capsule endoscopy (CE) in patients with a history of gastric surgery. This study aims to evaluate the feasibility and diagnostic yield (DY) of orally ingested SB-CE in patients with surgically altered gastric anatomy. METHODS: Twenty-four European centers retrospectively identified patients who had SB-CE after total or subtotal gastrectomy. The primary outcome was the DY of SB-CE (intermediate P1 to highly P2 relevant findings). Secondary outcomes were gastric and SB transit times, completion, cleanliness, and adverse event rates. RESULTS: Studied were 248 procedures from 243 patients (mean age, 62 years) with a history of partial gastrectomy (Billroth I, 13.1%; Billroth II, 34.6%), total gastrectomy (7.4%), Whipple procedure (12.8%), sleeve gastrectomy (7.2%), or gastric bypass surgery (24.7%). Obscure GI bleeding was the most frequent indication (85.1%). SB completion rate was 84.3%. One capsule retention in the SB was noted (adverse event rate, .4%). Median SB transit time was 286 minutes (interquartile range [235; 387]). Cleanliness was rated as adequate in 92.1% of procedures. After exclusion of abnormalities found at the upper anastomotic site, the DY was 43.6%, with inflammatory/ulcerated lesions observed more frequently (23.4%) than vascular lesions (21.0%). CONCLUSIONS: SB-CE seems to be feasible and safe in selected patients with a history of major gastric surgery and comes with a high DY. The spectrum of abnormal SB findings in these patients may be different from what is known from the literature in nonoperated patients.


Assuntos
Endoscopia por Cápsula , Estudos de Viabilidade , Hemorragia Gastrointestinal/etiologia , Humanos , Intestino Delgado , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
Endosc Int Open ; 9(1): E22-E30, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33403232

RESUMO

Background and study aims The aim of this study was to elucidate the differences in image-enhanced endoscopy (IEE) findings between Helicobacter - pylori -associated and autoimmune gastritis. Patients and methods Seven H. pylori -naïve, 21 patients with H. pylori -associated gastritis and seven with autoimmune gastritis were enrolled. Mucosal atrophy in the corpus was evaluated using autofluorescence imaging and classified into small, medium and large. In a 2 × 2-cm area of the lesser curvature of the lower corpus, micromucosal pattern was evaluated by magnifying narrow band imaging and proportion of foveola (FV)- and groove (GR)-type mucosa was classified into FV > 80 %, FV 50 % to 80 %, GR 50 % to 80 %, and GR > 80 %, then a biopsy specimen was taken. Results Fifteen of 21 (71 %) H. pylori -associated gastritis patients exhibited medium-to-large atrophic mucosa at the corpus lesser curvature. All autoimmune gastritis patients had large atrophic mucosa throughout the corpus ( P  < 0.001). All H. pylori -naïve patients had the FV > 80 % micromucosal pattern. Nineteen of 21 (90 %) H. pylori -associated gastritis patients had varying proportions of GR- and FV-type mucosae and five of seven (71 %) autoimmune gastritis patients showed FV > 80 % mucosa ( P  < 0.001). Compared with patients who were H. pylori -naïve, patients with H. pylori -associated and autoimmune gastritis exhibited a higher grade of atrophy ( P  < 0.001), but only patients with H. pylori -associated gastritis showed a higher grade of intestinal metaplasia ( P  = 0.022). Large mucosal atrophy with FV > 80 % micromucosal pattern had sensitivity of 71 % (95 % CI: 29 %-96 %) and specificity of 100 % (95 % CI: 88 % to 100 %) for diagnosis of autoimmune gastritis. Conclusions IEE findings of the gastric corpus differed between H. pylori -associated and autoimmune gastritis, suggesting different pathogenesis of the two diseases.

5.
J Clin Med ; 9(9)2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32942749

RESUMO

BACKGROUND: Conventional colonoscopy (CC) allows access for colonic investigation and intervention; in the small group in whom CC is unsuccessful alternative imaging is often sufficient. There remains a subset, however, requiring full colonic visualisation or intervention. Balloon-assisted colonoscopy (BAC) gives a further option when access is difficult. Aims: This study aims to present the experience with BAC of two European tertiary referral centres. Methods: Procedures were carried out under local protocol over 15-years (2006-2020). Markers of procedural quality such as caecal intubation, complications and comfort were retrospectively compiled and analysed. Published evidence was summarised for comparison. Results: 122 procedures were undertaken, with polyps the most frequent indication and 90.2% having at least one previously incomplete CC. Features associated with difficult colonoscopy were common, including intraabdominal surgery (32.0%). 92.6% reached the caecum; completion was higher (96.3%) in those failing CC due to discomfort and lower in those failing due to anatomical difficulties (90.7%) or previous surgery (84.6%). Mean time to the caecum was 20.9 minutes and mean midazolam and fentanyl doses were 2.6 mg and 49.9 µg with low discomfort scores. Conclusion(s): Balloon-assisted colonoscopy is successful in >90% of patients, is well-tolerated, and is safe.

6.
United European Gastroenterol J ; 8(1): 99-107, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32213061

RESUMO

BACKGROUND: In the medical literature, the nomenclature and descriptions (ND) of small bowel (SB) ulcerative and inflammatory (U-I) lesions in capsule endoscopy (CE) are scarce and inconsistent. Inter-observer variability in interpreting these findings remains a major limitation in the assessment of the severity of mucosal lesions, which can impact negatively on clinical care, training and research on SB-CE. OBJECTIVE: Focusing on SB-CE in Crohn's disease (CD), our aim is to establish a consensus on the ND of U-I lesions. METHODS: An international panel of experienced SB-CE readers was formed during the 2016 United European Gastroenterology Week meeting. A core group of five CE and inflammatory bowel disease (IBD) experts established an Internet-based, three-round Delphi consensus but did not participate in the voting process. The core group built illustrated questionnaires, including SB-CE still frames of U-I lesions from patients with documented CD. Twenty-seven other experts were asked to rate and comment on the different proposals for the ND of the most frequent SB U-I lesions. For each round, we used a 6-point rating scale (varying from 'strongly disagree' to 'strongly agree'). The consensus was reached when at least 80 % of the voting members scored the statement within the 'agree' or 'strongly agree' categories. RESULTS: A 100% participation rate was obtained for all the rounds. Consensual ND were reached for the following seven U-I lesions: aphthoid erosion, deep ulceration, superficial ulceration, stenosis, edema, hyperemia and denudation. CONCLUSION: Considering the most frequent SB U-I lesions seen in CE in CD, a consensual ND was reached by the international group of experts. These descriptions and names are useful not only for daily practice and medical education, but also for medical research.


Assuntos
Endoscopia por Cápsula/normas , Doença de Crohn/diagnóstico , Intestino Delgado/diagnóstico por imagem , Terminologia como Assunto , Consenso , Doença de Crohn/imunologia , Doença de Crohn/patologia , Técnica Delphi , Gastroenterologia/normas , Humanos , Cooperação Internacional , Intestino Delgado/imunologia , Intestino Delgado/patologia , Variações Dependentes do Observador , Semântica
7.
J Clin Med ; 8(11)2019 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-31718057

RESUMO

Data on malignancy in patients with collagenous colitis (CC) is scarce. We aimed to determine the incidence of cancers in patients with CC. In a two-stages, observational study, data on cancers in patients diagnosed with CC during 2000-2015, were collected from two cohorts. The risk was calculated according to the age-standardized rate for the first cohort and according to the standardized incidence ratio for the second cohort. The first cohort comprised 738 patients (394 from Scotland and 344 from Sweden; mean age 71 ± 11 and 66 ± 13 years, respectively). The incidence rates for lung cancer (RR 3.9, p = 0.001), bladder cancer (RR 9.2, p = 0.019), and non-melanoma skin cancer (NMSC) (RR 15, p = 0.001) were increased. As the majority of NMSC cases (15/16) came from Sweden, a second Swedish cohort, comprising 1141 patients (863 women, mean age 65 years, range 20-95 years) was collected. There were 93 cancer cases (besides NMSC). The risk for colon cancer was decreased (SIR 0.23, p= 0.0087). The risk for cutaneous squamous cell carcinoma was instead markedly increased (SIR 3.27, p = 0.001).

8.
Therap Adv Gastroenterol ; 11: 1756284818758929, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29531578

RESUMO

BACKGROUND: Video capsule endoscopy (VCE) is a noninvasive method enabling excellent visualization of the small bowel (SB) mucosa. The aim of this study was to examine the impact and safety of VCE performed in children and adolescents with suspected or established Crohn's disease (CD). METHODS: A total of 180 VCE examinations in 169 consecutive patients conducted in 2003-14 in a single center were retrospectively analyzed. The median age was 13 years (range 3-17 years) and indications for VCE were suspected (125 cases, 69%) and established (55 cases, 31%) CD. VCE was performed with a PillCam SB (Given Imaging, Yokneam, Israel) VCE system with 8-12 h of registration without bowel preparation. RESULTS: A total of 154 of 180 (86%) patients swallowed the capsule and 26 (14%) had the capsule endoscopically placed in the duodenum. Patency capsule examination was performed in 71 cases prior to VCE to exclude SB obstruction. VCE detected findings consistent with SB CD in 71 (40%) examinations and 17 (9%) procedures showed minor changes not diagnostic for CD. A total of 92 (51%) examinations displayed normal SB mucosa. The capsule did not reach the colon within the recording time in 30 (17%) procedures and were defined as incomplete examinations. A change in diagnosis or therapy was recommended in 56 (31%) patients based on VCE results. Capsule retention occurred in one patient. CONCLUSIONS: VCE is a safe method in children with suspected or established CD. VCE often leads to a definitive diagnosis and has a significant impact on the clinical management of pediatric patients with CD.

9.
United European Gastroenterol J ; 5(5): 677-686, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28815031

RESUMO

BACKGROUND: The most concerning complication of video capsule endoscopy (VCE) is capsule retention (CR) in the gastrointestinal (GI) tract although clinical outcome and management of patients with CR are still uncertain in a large single center material. OBJECTIVES: The aim of this retrospective study was to investigate incidence, causes, risk factors, management and clinical outcomes of CR in a large single center between 2001 and 2011. RESULTS: 2401 consecutive small-bowel (SB) VCEs were performed. CR was detected in 25 cases (1%). CR in patients with suspected and known Crohn's disease (CD) undergoing VCE occurred in 14/1370 (1%) including known CD 9/390 (2.3%) and suspected CD 5/980 (0.5%). CR in patients with obscure GI bleeding was observed in 11/816 (1.3%) cases. The SB was the most common site of CR with 17 cases followed by the esophagus (4 cases), colon (2 cases), and stomach (2 cases). Emergency endoscopic intervention (3 cases) and surgery (2 cases) was needed in 5 cases of CR. Elective capsule removal was performed by surgery in 6 cases and endoscopically in 8 cases. Three retained capsules dislodged after steroid treatment and another 3 cases of CR resolved without any intervention. CONCLUSION: This large clinical material demonstrates that CR is a rare complication with a favorable clinical outcome. Most patients with CR can be electively managed with non-surgical intervention.

11.
Ann Transl Med ; 5(9): 195, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28567375

RESUMO

BACKGROUND: Colon capsule endoscopy (CCE) offers direct mucosal visualisation without sedation or gas insufflation required in conventional colonoscopy (CC). However, evidence for the role of CCE as an adjunct or alternative to CC remains equivocal. In this observational cohort study, we report our experience of using CCE to investigate patients with suspected colon pathology at a tertiary referral centre. METHODS: From 2007-2015, consecutive patients requiring colonoscopy were recruited from a tertiary care centre in Malmo, Sweden. Data collected: patient demographics, indication for CCE, findings, bowel cleansing, colon transit time (CTT) and completeness of colon examination. RESULTS: Seventy-seven patients (57 F/20 F, median age 56 years) were included. The reason for CCE was previously incomplete or refused CC in 39 and 26 cases, and follow up of previous findings in 12 cases, respectively. The main clinical indications were gastrointestinal (GI) bleeding (n=28; 36%) and suspected inflammatory bowel disease (IBD) or follow-up of known IBD (n=23; 30%). CCE was complete in 58/77 (75%) patients. In 3 patients the colon was not reached; in the other 16, the capsule reached the rectum (n=4), sigmoid (n=6), descending colon (n=5) and transverse colon (n=1). Findings were: normal CCE (n=15; 19%) colonic diverticula (n=29; 38%), polyps (n=17; 22%), active IBD (n=12; 16%), haemorrhoids (n=8; 10%), colonic angioectasia (n=4; 5%) and cancer (n=1; 1%). Small-bowel findings were recorded in 8 (10%) patients. All patients tolerated bowel preparation and CCE well. Two patients with an ulcerated small-bowel stricture and cancer respectively experienced temporary capsule retention with spontaneous resolution. CONCLUSIONS: CCE is a well-tolerated alternative to CC, but requires technological improvement and optimisation of clinical practice to meet current reference standards. Although further technical development is required, CCE may complement or even replace CC for certain clinical indications.

12.
Lakartidningen ; 1142017 05 15.
Artigo em Sueco | MEDLINE | ID: mdl-28510243

RESUMO

High quality colonoscopy must be secured Colonoscopy plays a key role in the work-up of digestive diseases and constitutes the cornerstone in colorectal cancer diagnosis and prevention. Data suggest that the quality of colonoscopy varies widely between different endoscopists. This article summarizes current evidence and expert consensus on quality indicators, along with the evidence supporting their use in benchmarking, quality reporting, and continuous quality improvement in order to secure high quality colonoscopy. In particular, four quality indicators, i.e. adenoma detection rate, compliance with guidelines on intervals for endoscopic surveillance, cecal intubation rate and complications, should be monitored in endoscopy units to ensure that colonoscopy practice is of high quality. Proper performance and documentation of high quality colonoscopy is critical for reducing colorectal cancer incidence and mortality.


Assuntos
Colonoscopia/normas , Garantia da Qualidade dos Cuidados de Saúde , Indicadores de Qualidade em Assistência à Saúde , Adenoma/diagnóstico , Adenoma/prevenção & controle , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/prevenção & controle , Fidelidade a Diretrizes , Humanos
13.
Endosc Int Open ; 4(9): E964-9, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27652302

RESUMO

BACKGROUND AND AIMS: The patency capsule is designed to evaluate the patency of the small bowel before administration of small-bowel capsule endoscopy (SBCE) in patients at high risk of retention. The utilization of a patency capsule may be associated with a risk of symptomatic retention, but very few cases have been reported to date. The aim of our study was to describe our experience with this rare complication of a patency capsule. METHODS: This was a multicenter retrospective case series. The medical records of patients who underwent a patency capsule test were scanned and all cases of symptomatic retention were collected. RESULTS: In total, 20 symptomatic cases of retention out of 1615 (1.2 %) patency capsule tests were identified; in one patient, the patency capsule was retained in the esophagus, in the rest, the capsule was detected in the small bowel resulting in abdominal pain or small-bowel obstruction. One patient (5 %) required surgery; all other patients resolved spontaneously or after corticosteroid therapy. CONCLUSIONS: Symptomatic patency capsule retention is a very rare complication with a favorable prognosis. It should be recognized but its use in patients with suspected small-bowel stenosis should not be discouraged.

14.
Endoscopy ; 48(4): 373-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26561918

RESUMO

BACKGROUND AND STUDY AIMS: Video capsule endoscopy (VCE) is invaluable in the diagnosis of small-bowel pathology. Capsule retention is a major concern in patients with Crohn's disease. The patency capsule was designed to evaluate small-bowel patency before VCE. However, the actual benefit of the patency capsule test in Crohn's disease remains unclear. The aim of this study was to evaluate the clinical impact of patency capsule use on the risk of video capsule retention in patients with established Crohn's disease. PATIENTS AND METHODS: This was a retrospective, multicenter study of patients with established Crohn's disease who underwent VCE for clinical need. The utilization strategy for the patency capsule was classified as selective (only in patients with obstructive symptoms, history of intestinal obstruction or surgery, or per treating physician's request) or nonselective (all patients with Crohn's disease). The main outcome was video capsule retention in the entire cohort and within each utilization strategy. RESULTS: A total of 406 patients who were referred for VCE were included in the study. VCE was performed in 132 /406 patients (32.5 %) without a prior patency capsule test. The patency capsule test was performed in 274 /406 patients (67.5 %) and was negative in 193 patients. Overall, VCE was performed in 343 patients and was retained in the small bowel in 8 (2.3 %). In this cohort, the risk of video capsule retention in the small bowel was 1.5 % without use of a prior patency capsule and 2.1 % after a negative patency test (P = 0.9). A total of 18 patients underwent VCE after a positive patency capsule test, with a retention rate of 11.1 % (P = 0.01). Patency capsule administration strategy (selective vs. nonselective) was not associated with the risk of video capsule retention. CONCLUSIONS: Capsule retention is a rare event in patients with established Crohn's disease undergoing VCE. The risk of video capsule retention was not reduced by the nonselective use of the patency capsule. Furthermore, VCE after a positive patency capsule test in patients with Crohn's disease was associated with a high risk of video capsule retention.


Assuntos
Endoscopia por Cápsula/efeitos adversos , Doença de Crohn/diagnóstico , Remoção de Dispositivo/métodos , Obstrução Intestinal/cirurgia , Intestino Delgado/patologia , Adulto , Endoscopia por Cápsula/instrumentação , Cápsulas , Estudos Transversais , Desenho de Equipamento , Falha de Equipamento , Feminino , Seguimentos , Humanos , Obstrução Intestinal/diagnóstico , Obstrução Intestinal/etiologia , Masculino , Estudos Retrospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...