Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 46(5): 588-99, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18598201

RESUMO

BACKGROUND: Cancer antigen CA125 is known as a valuable marker for the management of ovarian cancer. METHODS: The analytical and clinical performance of the Access OV Monitor Immunoassay System (Beckman Coulter) was evaluated at five different European sites and compared with a reference system, defined as CA125 on the Elecsys System (Roche Diagnostics). RESULTS: Total imprecision (% CV) of the OV Monitor ranged between 3.1% and 8.8%, and inter-laboratory reproducibility between 4.7% and 5.0%. Linearity upon dilution showed a mean recovery of 100% (SD + 8.1%). Endogenous interferents had no influence on OV Monitor levels (mean recoveries: hemoglobin 107%, bilirubin 103%, triglycerides 103%). There was no high-dose hook effect up to 27,193 kU/L. Clinical performance investigated in sera from 1811 individuals showed a good correlation between the Access OV Monitor and Elecsys CA125 (R = 0.982, slope = 0.921, intercept = +1.951). OV Monitor serum levels were low in healthy individuals (n = 267, median = 9.7 kU/L, 95th percentile = 30.8 kU/L), higher in individuals with various benign diseases (n = 549, medians = 10.9-16.4 kU/L, 95th percentiles = 44.2-355 kU/L) and even higher in individuals suffering from various cancers (n = 995, medians = 12.4-445 kU/L; 95th percentiles = 53.4-4664 kU/L). Optimal diagnostic accuracy for cancer detection against the relevant benign control group by the OV Monitor was found for ovarian cancer [area under the curve (AUC) 0.898]. Results for the reference CA125 assay were comparable (AUC 0.899). CONCLUSIONS: The Access OV Monitor provides very good methodological characteristics and demonstrates an excellent analytical and clinical correlation with Elecsys CA125. The best diagnostic accuracy for the OV Monitor was found in ovarian cancer. Our results also suggest a clinical value of the OV Monitor in other cancers.


Assuntos
Anticorpos/sangue , Antígeno Ca-125/análise , Imunoensaio/métodos , Neoplasias Ovarianas/diagnóstico , Europa (Continente) , Feminino , Humanos , Imunoensaio/instrumentação , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Clin Chem Lab Med ; 46(5): 600-11, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18598202

RESUMO

BACKGROUND: Gastrointestinal cancer antigen CA19-9 is known as a valuable marker for the management of patients with pancreatic cancer. METHODS: The analytical and clinical performance of the Access GI Monitor assay (Beckman Coulter) was evaluated on the UniCel Dxl 800 Immunoassay System at five different European sites and compared with a reference method, defined as CA19-9 on the Elecsys System (Roche Diagnostics). RESULTS: Total imprecision (%CV) of the GI Monitor ranged between 3.4% and 7.7%, and inter-laboratory reproducibility between 3.6% and 4.0%. Linearity upon dilution showed a mean recovery of 97.4% (SD + 7.2%). Endogenous interferents had no influence on GI Monitor levels (mean recoveries: hemoglobin 103%, bilirubin 106%, triglycerides 106%). There was no high-dose hook effect up to 115,000 kU/L. Clinical performance investigated in sera from 1811 individuals showed a good correlation between the Access GI Monitor and Elecsys CA19-9 (R = 0.959, slope = 1.004, intercept = +0.17). GI Monitor serum levels were low in healthy individuals (n = 267, median = 6.0 kU/L, 95th percentile=23.1 kU/L), higher in individuals with various benign diseases (n = 550, medians = 5.8-13.4 kU/L, 95th percentiles = 30.1-195.5 kU/L) and even higher in individuals suffering from various cancers (n = 995, medians = 8.4-233.8 kU/L, 95th percentiles = 53.7-13,902 kU/L). Optimal diagnostic accuracy for cancer detection against the relevant benign control group by the GI Monitor was found for pancreatic cancer [area under the curve (AUC) 0.83]. Results for the reference CA19-9 assay were comparable (AUC 0.85). CONCLUSIONS: The Access GI Monitor provides very good methodological characteristics and demonstrates an excellent analytical and clinical correlation with the Elecsys CA19-9. The GI Monitor shows the best diagnostic accuracy in pancreatic cancer. Our results also suggest a clinical value of the GI Monitor in other cancers.


Assuntos
Anticorpos/química , Antígeno CA-19-9/sangue , Imunoensaio/métodos , Neoplasias Pancreáticas/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Europa (Continente) , Feminino , Humanos , Imunoensaio/instrumentação , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/sangue , Reprodutibilidade dos Testes
3.
Clin Chem Lab Med ; 46(5): 612-22, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18598203

RESUMO

BACKGROUND: Cancer antigen CA15-3 antigen is known as a valuable marker for the management of breast cancer. METHODS: The analytical and clinical performance of the Access BR Monitor Immunoassay System (Beckman Coulter) was evaluated at five different European sites and compared with a reference system, defined as CA15-3 on the Elecsys System (Roche Diagnostics). RESULTS: Total imprecision (% CV) of the BR Monitor ranged between 5.5% and 11.7%, and inter-laboratory reproducibility between 3.4% and 5.1%. Linearity upon dilution showed a mean recovery of 98.5% (SD + 9.1%). Endogenous interferents had no influence on BR Monitor levels (mean recoveries: hemoglobin 112%, bilirubin 111%, triglycerides 108%). There was no high-dose hook effect up to 13,540 kU/L. Clinical performance investigated in sera from individuals showed a general correlation between the Access BR Monitor and Elecsys CA15-3 (R = 0.797), with a slope of 1.383. CA15-3 serum levels, as measured by the BR Monitor, were low in healthy individuals (n = 267, median = 11.9 kU/L, 95th percentile = 23.5 kU/L), higher in individuals with various benign diseases (n = 549, medians = 11.3-15.6 kU/L, 95th percentiles = 21.6-54.6 kU/L) and even higher in individuals suffering from various cancers (n = 995, medians = 11.2-22.8 kU/L, 95th percentiles = 30.0-429.7 kU/L). Best diagnostic accuracy for cancer detection against the relevant benign control group by the BR Monitor was found for locoregional and metastatic breast cancer, as well as for ovarian cancer [area under the curve (AUC) 0.619, 0.897 and 0.774]. Results for the reference CA15-3 assay were comparable (AUC 0.611, 0.887 and 0.818). CONCLUSIONS: The Access BR Monitor provides accurate methodological characteristics and demonstrates an analytical and clinical correlation with Elecsys CA15-3. Best diagnostic accuracy for the BR Monitor was found in breast and ovarian cancer. Our results also suggest a clinical value of the BR Monitor in other cancers.


Assuntos
Anticorpos/química , Neoplasias da Mama/diagnóstico , Imunoensaio/métodos , Mucina-1/sangue , Neoplasias Ovarianas/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Neoplasias da Mama/sangue , Europa (Continente) , Feminino , Humanos , Imunoensaio/instrumentação , Pessoa de Meia-Idade , Neoplasias Ovarianas/sangue , Padrões de Referência , Reprodutibilidade dos Testes
4.
Cereb Cortex ; 16(3): 376-85, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15930370

RESUMO

A novel Hebbian stimulation paradigm was employed to examine physiological correlates of motor memory formation in humans. Repetitive pairing of median nerve stimulation with transcranial magnetic stimulation over the contralateral motor cortex (paired associative stimulation, PAS) may decrease human motor cortical excitability at interstimulus intervals of 10 ms (PAS10) or increase excitability at 25 ms (PAS25). The properties of this plasticity have previously been shown to resemble associative timing-dependent long-term depression (LTD) and long-term potentiation (LTP) as established in vitro. Immediately after training a novel dynamic motor task, the capacity of the motor cortex to undergo plasticity in response to PAS25 was abolished. PAS10-induced plasticity remained unchanged. When retested after 6 h, PAS25-induced plasticity recovered to baseline levels. After training, normal PAS25-induced plasticity was observed in the contralateral training-naive motor cortex. Motor training did not reduce the efficacy of PAS25 to enhance cortical excitability when PAS10 was interspersed between the training and application of the PAS25 protocol. This indicated that the mechanism supporting PAS25-induced plasticity had remained intact immediately after training. Behavioral evidence was obtained for continued optimization of force generation at a time when PAS25-induced plasticity was blocked in the training motor cortex. Application of the PAS protocols after motor training did not prevent the consolidation of motor skills evident as performance gains at later retesting. The results are consistent with a concept of temporary suppression of associative cortical plasticity by neuronal mechanisms involved in motor training. Although it remains an open question exactly which element of motor training was responsible for this effect, our findings may link dynamic properties of LTP formation, as established in animal experiments, with human motor memory formation and possibly dynamic motor learning.


Assuntos
Aprendizagem/fisiologia , Potenciação de Longa Duração/fisiologia , Córtex Motor/fisiologia , Destreza Motora/fisiologia , Inibição Neural/fisiologia , Plasticidade Neuronal/fisiologia , Estimulação Magnética Transcraniana/métodos , Adulto , Potencial Evocado Motor/fisiologia , Feminino , Humanos , Masculino , Fatores de Tempo
5.
Eur J Neurosci ; 20(4): 885-95, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15305857

RESUMO

Although it has been postulated that adult neurogenesis, i.e. the generation of functional neurons from progenitor cells in the mammalian brain, is involved in both the pathogenesis of depressive disorders and the therapeutic effect of antidepressant drugs, its regulation is still poorly understood. Nitric oxide, a gaseous messenger molecule, represents a possible modulating agent as it is involved in learning and memory formation as well as synapto- and morphogenesis. Here we investigated whether adult neurogenesis is altered in mice lacking endothelial nitric oxide synthase (NOS-III). Compared to wild-type littermates, NOS-III-deficient mice showed a significant reduction in neuronal progenitor cell proliferation in the dentate gyrus, suggesting a role for NOS-III in the stimulation of neuroneogenesis. NeuN, beta-III-tubulin and GFAP double-immunolabelling demonstrated that proliferating progenitor cells differentiate preferentially into neurons but not into astrocytes. However, when the survival rate of newly formed cells was examined no difference between wild-type and NOS-III knockout mice was found, suggesting that NOS-III selectively exerts its effects on the proliferation of progenitor cells. This might be mediated by a decrease in vascular endothelial growth factor (VEGF) transcripts in the hippocampus of knockout animals. At the behavioural level, while NOS-III knockout mice displayed better and faster learning in a learned helplessness paradigm, no depression-like behaviours were observed. In conclusion, our results indicated that NOS-III is involved in the proliferation of neuronal progenitor cells, although behavioural analysis does not provide evidence for a pro-depressive effect of reduced neuroneogenesis.


Assuntos
Encéfalo/citologia , Encéfalo/enzimologia , Desamparo Aprendido , Neurônios/enzimologia , Óxido Nítrico Sintase/fisiologia , Células-Tronco/enzimologia , Animais , Aprendizagem da Esquiva/fisiologia , Encéfalo/fisiologia , Diferenciação Celular/genética , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Neurônios/citologia , Óxido Nítrico Sintase/deficiência , Óxido Nítrico Sintase/genética , Óxido Nítrico Sintase Tipo II , Óxido Nítrico Sintase Tipo III , Células-Tronco/citologia
6.
J Neurophysiol ; 92(1): 66-72, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-14724259

RESUMO

The role of attention in generating motor memories remains controversial principally because it is difficult to separate the effects of attention from changes in kinematics of motor performance. We attempted to disentangle attention from performance effects by varying attention while plasticity was induced in human primary motor cortex by external stimulation in the absence of voluntary movement. A paired associative stimulation (PAS) protocol was employed consisting of repetitive application of single afferent electric stimuli, delivered to the right median nerve, paired with single-pulse transcranial magnetic stimulation (TMS) over the optimal site for activation of the right abductor pollicis brevis muscle (APB) to generate near-synchronous events in the left primary motor cortex. In experiment 1, the spatial location of attention was varied. PAS failed to induce plasticity when the subject's attention was directed to their left hand, away from the right target hand the cortical representation of which was being stimulated by PAS. In experiment 2, the grade of attention to the target hand was manipulated. PAS-induced plasticity was maximal when the subject viewed their target hand, and its magnitude was slightly reduced when the subject could only feel their hand. Conversely, plasticity was completely blocked when the subject's attention was diverted from the target hand by a competing cognitive task. A similar modulation by attention was observed for PAS-induced changes in the duration of the silent period evoked by TMS in voluntarily contracted muscle. Associative plasticity in the human motor cortex depends decisively on attention.


Assuntos
Associação , Atenção/fisiologia , Potencial Evocado Motor/fisiologia , Córtex Motor/fisiologia , Plasticidade Neuronal/fisiologia , Adulto , Análise de Variância , Estimulação Elétrica/métodos , Eletromiografia/métodos , Feminino , Humanos , Masculino
7.
Suppl Clin Neurophysiol ; 57: 563-9, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-16106657

RESUMO

Paired associative stimulation (PAS) refers to a paradigm consisting of slow-rate repetitive low-frequency median nerve stimulation combined with transcranial magnetic stimulation (TMS) over the contralateral motor cortex. This protocol has been shown to induce plastic changes of excitability in the human motor cortex. Its principles of design were shaped after associative long-term potentiation (LTP) in experimental animals, a cellular mechanism likely to be relevant for learning and memory. PAS-induced changes of cortical excitability share a number of physiological properties with LTP. Of particular importance is the fact that the sign of PAS-induced changes of the size of amplitudes of the motor evoked potentials (MEPs) depends on the exact interval between the afferent and the magnetic pulse during the intervention. A number of observations suggest that PAS-induced excitability changes may have functional significance. PAS-induced plasticity may contribute to elucidating the pathogenesis of neurological disorders where neuroplasticity is thought to have a pathogenetic role. Finally, PAS-induced plasticity may itself have therapeutic potential.


Assuntos
Córtex Cerebral/efeitos da radiação , Estimulação Elétrica , Plasticidade Neuronal/efeitos da radiação , Animais , Córtex Cerebral/anatomia & histologia , Córtex Cerebral/fisiologia , Eletromiografia/métodos , Potencial Evocado Motor/fisiologia , Potencial Evocado Motor/efeitos da radiação , Potenciais Somatossensoriais Evocados/fisiologia , Potenciais Somatossensoriais Evocados/efeitos da radiação , Lateralidade Funcional , Humanos , Aprendizagem/fisiologia , Magnetismo , Plasticidade Neuronal/fisiologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA