Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Frontline Gastroenterol ; 2(2): 96-104, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28839590
2.
AJR Am J Roentgenol ; 192(6): 1682-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19457835

RESUMO

OBJECTIVE: The objective of our study was to investigate whether an increasing number of computer-aided detection (CAD) false-positives decreases reader sensitivity, specificity, and confidence for nonexpert readers of CT colonography (CTC). MATERIALS AND METHODS: Fifty CTC data sets (29 men; mean age, 65 years), 25 of which contained 35 polyps > or = 5 mm, were selected in which CAD had 100% polyp sensitivity at two sphericity settings (0 and 75) but differed in the number of false-positives. The data sets were read by five readers twice: once at each sphericity setting. Sensitivity, specificity, report time, and confidence before and after second-read CAD were compared using the paired exact and Student's t test, respectively. Receiver operating characteristic (ROC) curves were generated using reader confidence (1-100) in correct case classification (normal or abnormal). RESULTS: CAD generated a mean of 42 (range, 3-118) and 15 (range, 1-36) false-positives at a sphericity of 0 and 75, respectively. CAD at both settings increased per-patient sensitivity from 82% to 87% (p = 0.03) and per-polyp sensitivity by 8% and 10% for a sphericity of 0 and 75, respectively (p < 0.001). Specificity decreased from 84% to 79% (sphericity 0 and 75, p = 0.03 and 0.07). There was no difference in sensitivity, specificity, or reader confidence between sphericity settings (p = 1.0, 1.0, 0.11, respectively). The area under the ROC curve was 0.78 (95% CI, 0.70-0.86) and 0.77 (0.68-0.85) for a sphericity of 0 and 75, respectively. CAD added a median of 4.4 minutes (interquartile range [IQR], 2.7-6.5 minutes) and 2.2 minutes (IQR, 1.2-4.0 minutes) for a sphericity of 0 and 75, respectively (p < 0.001). CONCLUSION. CAD has the potential to increase the sensitivity of readers inexperienced with CTC, although specificity may be reduced. An increased number of CAD-generated false-positives does not negate any beneficial effect but does reduce efficiency.


Assuntos
Inteligência Artificial , Atitude do Pessoal de Saúde , Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Algoritmos , Reações Falso-Positivas , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...