Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Rheum Dis ; 65(12): 1649-52, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17105853

RESUMO

OBJECTIVE: To evaluate a modified American College of Rheumatology 20 (mACR20) scoring system for patients with rheumatoid arthritis. METHODS: The data were evaluated from one study on patients with methotrexate (MTX)-naive early rheumatoid arthritis (ERA) and another study on patients with DMARD-refractory late rheumatoid arthritis (LRA). For mACR20 scoring, acute-phase reactant measurements were excluded, and 20% improvement from baseline was determined by 2 or 3 of the 4 remaining ACR components. RESULTS: For full joint counts with data from patients with ERA, marked differences favoured 25 mg etanercept (ETN) over 10 mg ETN by using the unmodified ACR20 (69% v 55%), the mACR20(3 of 4) (63% v 49%) and the mACR20(2 of 4) (72% v 58%). An assessment of 28 joints showed similar findings. In the trial on patients with LRA, considerably more patients in both ETN groups achieved a clinical response compared with placebo by using the ACR20, the mACR20(3 of 4) and the mACR20(2 of 4), whether using full or 28 joint counts. The mACR20(3 of 4) and full joint counts with data on patients with ERA showed a marked difference between the MTX and 10 mg ETN groups (63% v 49%), which was not observed with the ACR20. CONCLUSION: Patterns of improvement indicated by mACR20 scores were consistent with standard ACR20 scores.


Assuntos
Antirreumáticos/uso terapêutico , Artrite Reumatoide/tratamento farmacológico , Imunoglobulina G/uso terapêutico , Receptores do Fator de Necrose Tumoral/uso terapêutico , Índice de Gravidade de Doença , Sedimentação Sanguínea , Proteína C-Reativa/análise , Relação Dose-Resposta a Droga , Etanercepte , Feminino , Humanos , Masculino , Metotrexato/uso terapêutico , Pessoa de Meia-Idade , Resultado do Tratamento
2.
Circulation ; 104(9): 1023-8, 2001 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-11524396

RESUMO

BACKGROUND: Approximately 25% of patients who receive an implantable cardioverter-defibrillator (ICD) to treat ventricular tachyarrhythmias have documented atrial tachyarrhythmias before implantation. This study assessed the ability of device-based prevention and termination therapies to reduce the burden of spontaneous atrial tachyarrhythmias. METHODS AND RESULTS: Patients with a standard indication for the implantation of an ICD and 2 episodes of atrial tachyarrhythmias in the preceding year received a dual-chamber ICD (Medtronic 7250 Jewel AF) that uses pacing and shock therapies for prevention and/or termination of atrial tachyarrhythmias. In a multicenter trial, patients were randomized to 3-month periods with atrial therapies "on" or "off" and subsequently crossed over. Analysis was performed on the 52 of 269 patients who had episodes of atrial tachyarrhythmia and had >/=30 days of follow-up with atrial therapies on and off. The atrial therapies resulted in a reduction of atrial tachyarrhythmia burden from a mean of 58.5 to 7.8 h/mo. A paired analysis (Wilcoxon signed-rank test) showed that the median difference in burden (1.1 h/mo) was highly significant (P=0.007). When the subgroup of 41 patients treated only with atrial pacing therapies was analyzed, the reduction in burden persisted (P=0.01). CONCLUSIONS: In this study, patients with a standard ICD indication and atrial tachyarrhythmias had a significant reduction in atrial tachyarrhythmia burden with use of atrial pacing and shock therapies.


Assuntos
Fibrilação Atrial/prevenção & controle , Desfibriladores Implantáveis , Taquicardia Ventricular/terapia , Idoso , Fibrilação Atrial/fisiopatologia , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...