Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Phys Condens Matter ; 30(24): 245502, 2018 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-29726842

RESUMO

k paths exactly with [Formula: see text] symmetry allow to find triply degenerate points (TDPs) in band structures. The paths that host the type-II Dirac points in PtSe2 family materials also have the [Formula: see text] spatial symmetry. However, due to Kramers degeneracy (the systems have both inversion symmetry and time reversal symmetry), the crossing points in them are Dirac ones. In this work, based on symmetry analysis, first-principles calculations, and [Formula: see text] method, we predict that PtSe2 family materials should undergo topological transitions if the inversion symmetry is broken, i.e. the Dirac fermions in PtSe2 family materials split into TDPs in PtSeTe family materials (PtSSe, PtSeTe, and PdSeTe) with orderly arranged S/Se (Se/Te). It is different from the case in high-energy physics that breaking inversion symmetry I leads to the splitting of Dirac fermion into Weyl fermions. We also address a possible method to achieve the orderly arranged in PtSeTe family materials in experiments. Our study provides a real example that Dirac points transform into TDPs, and is helpful to investigate the topological transition between Dirac fermions and TDP fermions.

2.
Inorg Chem ; 56(9): 4990-4995, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28406625

RESUMO

Double-ReO3-type structure compound NaSbF6 undergoes a low-temperature rhombohedral to high-temperature cubic phase between 303 and 323 K, as revealed by temperature-dependent X-ray diffractions. Although many double-ReO3-type fluorides exhibit either low thermal expansion or negative thermal expansion (NTE), NaSbF6 exhibits positive thermal expansion (PTE) with a large volumetric coefficient of thermal expansion, αv = 62 ppm/K, in its cubic phase. Raman spectroscopy reveals that the low-frequency transverse vibration of fluorine atoms is stiffened in NaSbF6, compared with the typical NTE compound CaZrF6 with the same structure. The related weak contraction associated with the polyhedral rocking would be overcome by the notable elongation of the Na-F bond length on heating, thus leading to the large volumetric PTE. Unlike ScF3 and CaZrF6 which are insulators with a wide band gap, a relative small band gap of 3.76 eV was observed in NaSbF6. The small band gap can be attributed to the hybridization between the Sb 5s and F 2p orbitals.

3.
Orthop Traumatol Surg Res ; 100(7): 745-50, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25281549

RESUMO

BACKGROUND: Although cross-linked polyethylene is resistant to wear in comparison to conventional polyethylene, it remains unknown whether it can decrease the wear-related revision rate of total hip arthroplasty. OBJECTIVES: To determine whether cross-linked polyethylene decreases the wear-related revision rate of total hip arthroplasty compared with conventional polyethylene. DATA SOURCES: Electronic databases, including PubMed, EMBASE, and the Cochrane Central Register of Controlled Trials, were queried from inception to July 6, 2013. STUDY SELECTION: Randomized controlled trials (RCTs) comparing cross-linked polyethylene with conventional polyethylene were included. In addition, the standard 28-mm femoral head was used, and follow-up was performed for a minimum of 5 years. The primary outcome assessed was wear-related revision. The secondary outcome measures evaluated were the incidence of osteolysis, the linear wear rate, and the linear head penetration. DATA SYNTHESIS: The Cochrane Collaboration's tool for assessing the risk of bias was used for quality assessment. Data from eligible studies were pooled using a random effects model. RESULTS: Eight studies involving 735 patients were included in this study. Meta-analysis showed there was no significant difference between cross-linked and conventional polyethylene group in terms of osteolysis or wear-related revision. The pooled mean differences were significantly less for the linear wear rate and linear head penetration for cross-linked polyethylene than for conventional polyethylene. LIMITATIONS: The studies differed with respect to the cross-linked liner brands, manufacturing processes, and radiological evaluation methods. Moreover, the follow-up periods of the RCTs were not long enough. CONCLUSIONS: The current limited evidence suggests that cross-linked polyethylene significantly reduced the radiological wear compared with conventional polyethylene at midterm follow-up periods. However, there is no evidence that cross-linked polyethylene had an advantage over conventional polyethylene in terms of reducing osteolysis or wear-related revision. Nevertheless, future long-term RCTs on this topic are needed. KEY FINDINGS: Cross-linked polyethylene significantly reduced radiological wear but not osteolysis or wear-related revision in comparison to conventional polyethylene at midterm follow-up periods. LEVEL OF EVIDENCE: Level I, systematic review of level I studies.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Reagentes de Ligações Cruzadas , Prótese de Quadril , Polietilenos , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Reoperação/estatística & dados numéricos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...