Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Radiology ; 310(3): e232255, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38470237

RESUMO

Background Large language models (LLMs) hold substantial promise for medical imaging interpretation. However, there is a lack of studies on their feasibility in handling reasoning questions associated with medical diagnosis. Purpose To investigate the viability of leveraging three publicly available LLMs to enhance consistency and diagnostic accuracy in medical imaging based on standardized reporting, with pathology as the reference standard. Materials and Methods US images of thyroid nodules with pathologic results were retrospectively collected from a tertiary referral hospital between July 2022 and December 2022 and used to evaluate malignancy diagnoses generated by three LLMs-OpenAI's ChatGPT 3.5, ChatGPT 4.0, and Google's Bard. Inter- and intra-LLM agreement of diagnosis were evaluated. Then, diagnostic performance, including accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve (AUC), was evaluated and compared for the LLMs and three interactive approaches: human reader combined with LLMs, image-to-text model combined with LLMs, and an end-to-end convolutional neural network model. Results A total of 1161 US images of thyroid nodules (498 benign, 663 malignant) from 725 patients (mean age, 42.2 years ± 14.1 [SD]; 516 women) were evaluated. ChatGPT 4.0 and Bard displayed substantial to almost perfect intra-LLM agreement (κ range, 0.65-0.86 [95% CI: 0.64, 0.86]), while ChatGPT 3.5 showed fair to substantial agreement (κ range, 0.36-0.68 [95% CI: 0.36, 0.68]). ChatGPT 4.0 had an accuracy of 78%-86% (95% CI: 76%, 88%) and sensitivity of 86%-95% (95% CI: 83%, 96%), compared with 74%-86% (95% CI: 71%, 88%) and 74%-91% (95% CI: 71%, 93%), respectively, for Bard. Moreover, with ChatGPT 4.0, the image-to-text-LLM strategy exhibited an AUC (0.83 [95% CI: 0.80, 0.85]) and accuracy (84% [95% CI: 82%, 86%]) comparable to those of the human-LLM interaction strategy with two senior readers and one junior reader and exceeding those of the human-LLM interaction strategy with one junior reader. Conclusion LLMs, particularly integrated with image-to-text approaches, show potential in enhancing diagnostic medical imaging. ChatGPT 4.0 was optimal for consistency and diagnostic accuracy when compared with Bard and ChatGPT 3.5. © RSNA, 2024 Supplemental material is available for this article.


Assuntos
Nódulo da Glândula Tireoide , Humanos , Feminino , Adulto , Nódulo da Glândula Tireoide/diagnóstico por imagem , Estudos Retrospectivos , Idioma , Redes Neurais de Computação , Curva ROC
2.
Electron. j. biotechnol ; Electron. j. biotechnol;19(3): 43-48, May 2016. ilus
Artigo em Inglês | LILACS | ID: lil-787006

RESUMO

Background: D-Hydroxyphenylglycine is considered to be an important chiral molecular building-block of antibiotic reagents such as pesticides, and β-lactam antibiotics. The process of its production is catalyzed by D-hydantoinase and D-carbamoylase in a two-step enzyme reaction. How to enhance the catalytic potential of the two enzymes is valuable for industrial application. In this investigation, an Escherichia coli strain genetically engineered with D-hydantoinase was immobilized by calcium alginate with certain adjuncts to evaluate the optimal condition for the biosynthesis of D-carbamoyl-p-hydroxyphenylglycine (D-CpHPG), the compound further be converted to D-hydroxyphenylglycine (D-HPG) by carbamoylase. Results: The optimal medium to produce D-CpHPG by whole-cell immobilization was a modified Luria-Bertani (LB) added with 3.0% (W/V) alginate, 1.5% (W/V) diatomite, 0.05% (W/V) CaCl2 and 1.00 mM MnCl2.The optimized diameter of immobilized beads for the whole-cell biosynthesis here was 2.60 mm. The maximized production rates of D-CpHPG were up to 76%, and the immobilized beads could be reused for 12 batches. Conclusions: This investigation not only provides an effective procedure for biological production of D-CpHPG, but gives an insight into the whole-cell immobilization technology.


Assuntos
Escherichia coli , Amidoidrolases , Glicina/análogos & derivados , Células Imobilizadas , Glicina/biossíntese
3.
Clinics (Sao Paulo) ; 70(10): 714-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26598086

RESUMO

The aim of this study was to establish whether the use of an extramedullary or intramedullary tibial cutting guide leads to superior mechanical leg axis and implant positioning. A meta-analysis of six randomized controlled trials including 350 knees was performed. For the mechanical axis, frontal tibial component angle and tibial slope, there were no significant differences in the mean values or the number of outliers (±3°) between the extramedullary and intramedullary groups. A reduced tourniquet time was associated with the intramedullary guide. No significant difference in the complication rate was noted between the two groups. Neither extramedullary nor intramedullary tibial alignment was more accurate in facilitating the tibial cut. Use of an intramedullary guide results in a shorter tourniquet time and exhibits a similar complication rate as the extramedullary guide.


Assuntos
Artroplastia do Joelho/métodos , Tíbia/cirurgia , Viés , Humanos , Radiografia , Ensaios Clínicos Controlados Aleatórios como Assunto , Tíbia/diagnóstico por imagem , Fatores de Tempo , Torniquetes
4.
Clinics ; Clinics;70(10): 714-719, Oct. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-762964

RESUMO

The aim of this study was to establish whether the use of an extramedullary or intramedullary tibial cutting guide leads to superior mechanical leg axis and implant positioning. A meta-analysis of six randomized controlled trials including 350 knees was performed. For the mechanical axis, frontal tibial component angle and tibial slope, there were no significant differences in the mean values or the number of outliers (±3°) between the extramedullary and intramedullary groups. A reduced tourniquet time was associated with the intramedullary guide. No significant difference in the complication rate was noted between the two groups. Neither extramedullary nor intramedullary tibial alignment was more accurate in facilitating the tibial cut. Use of an intramedullary guide results in a shorter tourniquet time and exhibits a similar complication rate as the extramedullary guide.


Assuntos
Humanos , Artroplastia do Joelho/métodos , Tíbia/cirurgia , Viés , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Tempo , Torniquetes , Tíbia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA