Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-698176

RESUMO

Background:Previous study has found that harmine inhibited the proliferation of gastric cancer cells by down-regulating cyclooxygenase-2(COX-2)expression. However,its molecular mechanism is not fully clear. Aims:To investigate the effect of harmine on proliferation and apoptosis of gastric cancer cells,and explore the role of PTEN/Akt/MDM2 signaling pathway in this process. Methods:Human gastric adenocarcinoma cell line SGC-7901 and MKN-45 were treated with harmine at different concentrations(2,4,8,16,32 μg/mL)for 24,48,and 72 hours. The cell proliferation and apoptosis were detected by MTT assay and Hoechst staining,respectively. The expressions of PTEN,COX-2, phosphorylated Akt(p-Akt)and p-MDM2 were measured by Western blotting. Results:Harmine dose- and time-dependently inhibited proliferation and induced apoptosis of SGC-7901 and MKN-45 cells. Also,harmine dose-dependently increased PTEN expression,and inhibited p-Akt,p-MDM2 and COX-2 expressions in SGC-7901 and MKN-45 cells. Conclusions:Harmine may inhibit proliferation and induce apoptosis of gastric cancer cells via down-regulating COX-2 expression through PTEN/Akt/MDM2 signaling pathway.

2.
Chinese Journal of Medical Imaging ; (12): 609-612,616, 2017.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-706375

RESUMO

Purpose To explore the application of single index,double exponential and tensile density index model diffusion weighted imaging and other parameters on endometrial carcinoma diagnosis to offer new ideas for it.Materials and Methods Intravoxel incoherent motion imaging data of 28 endometrial carcinoma patients and 24 patients of normal endometrium were analyzed retrospectively.Single index,double exponential and DWI parameter of endometrial carcinoma tissue and normal endometrial tissue were measured respectively,including standard apparent diffusion coefficient (ADC-stand),slow apparent diffusion coefficient (ADC-slow),fast apparent diffusion coefficient (ADC-fast,perfusion fraction (f),distributed diffusion coefficient (DDC) and a.Receiver operator characteristic (ROC) curve was adopted to assess threshold value and diagnostic efficiency of each parameter,and analyzed difference among each parameter in two groups and relativity of each parameter in the same group.Results ADC-stand,ADC-slow,f,DDC and a in endometrial carcinoma group were all lower than those in normal endometrium group.The difference was statistically significant (P<0.05).The difference of ADC-fast was not statistically significant (P>0.05).Areas of ADC-stand and ADC-slow on ROC curve were 0.949 and 0.911 respectively,and threshold values were 1.245×10-3 mm2/s and 0.998× 10-3 mm2/s.ADC-stand in endometrial carcinoma group was positive correlated with ADC-slow and DDC value (r=0.787 and 0.880,P<0.05).ADC-slow was significantly lower than ADC-stand (P<0.05).Conclusion The differences in single index,double exponential and DWI can provide new ideas for endometrial carcinoma diagnosis.

3.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-495295

RESUMO

Objective To apply the BestSeqTM new generation pathogenic gene detection technology to perform the genetic detec‐tion in the patients with progressive muscular dystrophy (PMD) validating its sensitivity and specificity .Methods The BestSeqTM new generation pathogenic gene detection technology was used to perform the gene sequencing in 2 cases of limb‐girdle muscular dystrophy(LGMD) and 6 cases of Dunchenne′s muscular dystrophy(DMD) ,and the found point mutations were confirmed by the Sanger sequencing method .Results This study completed the genetic detection in above 8 cases ,2 cases of large fragment deletion and 10 cases of micromutations were detected ,in which 8 micromutations were the new mutation discovered ffor the first time and verified by the Sanger sequencing .Conclusion The BestSeqTM new generation pathogenic gene detection technology greatly increa‐ses the detection efficiency by using the high density imbricate type probe and multiple tag technology ,and has the better clinical ap‐plication prospects .

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...