Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
J Magn Reson Imaging ; 59(2): 575-584, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37218596

RESUMO

BACKGROUND: Breast cancer treatment response evaluation using the response evaluation criteria in solid tumors (RECIST) guidelines, based on tumor volume changes, has limitations, prompting interest in novel imaging markers for accurate therapeutic effect determination. PURPOSE: To use MRI-measured cell size as a new imaging biomarker for assessing chemotherapy response in breast cancer. STUDY TYPE: Longitudinal; animal model. STUDY POPULATION: Triple-negative human breast cancer cell (MDA-MB-231) pellets (4 groups, n = 7) treated with dimethyl sulfoxide (DMSO) or 10 nM of paclitaxel for 24, 48, and 96 hours, and 29 mice with MDA-MB-231 tumors in right hind limbs treated with paclitaxel (n = 16) or DMSO (n = 13) twice weekly for 3 weeks. FIELD STRENGTH/SEQUENCE: Oscillating gradient spin echo and pulsed gradient spin echo sequences at 4.7 T. ASSESSMENT: MDA-MB-231 cells were analyzed using flowcytometry and light microscopy to assess cell cycle phases and cell size distribution. MDA-MB-231 cell pellets were MR imaged. Mice were imaged weekly, with 9, 6, and 14 being sacrificed for histology after MRI at weeks 1, 2, and 3, respectively. Microstructural parameters of tumors/cell pellets were derived by fitting diffusion MRI data to a biophysical model. STATISTICAL TESTS: One-way ANOVA compared cell sizes and MR-derived parameters between treated and control samples. Repeated measures 2-way ANOVA with Bonferroni post-tests compared temporal changes in MR-derived parameters. A P-value <0.05 was considered statistically significant. RESULTS: In vitro experiments showed that the mean MR-derived cell sizes of paclitaxel-treated cells increased significantly with a 24-hours treatment and decreased (P = 0.06) with a 96-hour treatment. For in vivo xenograft experiments, the paclitaxel-treated tumors showed significant decreases in cell size at later weeks. MRI observations were supported by flowcytometry, light microscopy, and histology. DATA CONCLUSIONS: MR-derived cell size may characterize the cell shrinkage during treatment-induced apoptosis, and may potentially provide new insights into the assessment of therapeutic response. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 4.


Assuntos
Neoplasias da Mama , Neoplasias de Mama Triplo Negativas , Humanos , Animais , Camundongos , Feminino , Paclitaxel/farmacologia , Paclitaxel/uso terapêutico , Neoplasias de Mama Triplo Negativas/diagnóstico por imagem , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Dimetil Sulfóxido/uso terapêutico , Linhagem Celular Tumoral , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/métodos , Tamanho Celular
2.
J Magn Reson ; 352: 107479, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37285709

RESUMO

PURPOSE: MR microscopy is in principle capable of producing images at cellular resolution (<10 µm), but various factors limit the quality achieved in practice. A recognized limit on the signal to noise ratio and spatial resolution is the dephasing of transverse magnetization caused by diffusion of spins in strong gradients. Such effects may be reduced by using phase encoding instead of frequency encoding read-out gradients. However, experimental demonstration of the quantitative benefits of phase encoding are lacking, and the exact conditions in which it is preferred are not clearly established. We quantify the conditions where phase encoding outperforms a readout gradient with emphasis on the detrimental effects of diffusion on SNR and resolution. METHODS: A 15.2 T Bruker MRI scanner, with 1 T/m gradients, and micro solenoid RF coils < 1 mm in diameter, were used to quantify diffusion effects on resolution and the signal to noise ratio of frequency and phase encoded acquisitions. Frequency and phase encoding's spatial resolution and SNR per square root time were calculated and measured for images at the diffusion limited resolution. The point spread function was calculated and measured for phase and frequency encoding using additional constant time phase gradients with voxels 3-15 µm in dimension. RESULTS: The effect of diffusion during the readout gradient on SNR was experimentally demonstrated. The achieved resolutions of frequency and phase encoded acquisitions were measured via the point-spread-function and shown to be lower than the nominal resolution. SNR per square root time and actual resolution were calculated for a wide range of maximum gradient amplitudes, diffusion coefficients, and relaxation properties. The results provide a practical guide on how to choose between phase encoding and a conventional readout. Images of excised rat spinal cord at 10 µm × 10 µm in-plane resolution demonstrate phase encoding's benefits in the form of higher measured resolution and higher SNR than the same image acquired with a conventional readout. CONCLUSION: We provide guidelines to determine the extent to which phase encoding outperforms frequency encoding in SNR and resolution given a wide range of voxel sizes, sample, and hardware properties.


Assuntos
Imageamento por Ressonância Magnética , Microscopia , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética , Razão Sinal-Ruído
3.
Magn Reson Med ; 90(2): 596-614, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37093984

RESUMO

PURPOSE: The purpose is to evaluate the relative contribution from confounding factors (T1 weighting and magnetization transfer) to the CEST ratio (CESTR)-quantified amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) (-3.5) in tumors as well as whether the CESTR can reflect the distribution of the solute concentration (fs ). METHODS: We first provided a signal model that shows the separate dependence of CESTR on these confounding factors and the clean CEST/NOE effects quantified by an apparent exchange-dependent relaxation (AREX) method. We then measured the change in these effects in the 9-L tumor model in rats, through which we calculated the relative contribution of each confounding factor. fs was also fitted, and its correlations with the CESTR and AREX were assessed to evaluate their capabilities to reflect fs . RESULTS: The CESTR-quantified APT shows "positive" contrast in tumors, which arises primarily from R1w at low powers and both R1w and magnetization transfer at high powers. CESTR-quantified NOE (-3.5) shows no or weak contrast in tumors, which is due to the cancelation of R1w and NOE (-3.5), which have opposite contributions. CESTR-quantified APT has a stronger correlation with APT fs than AREX-quantified APT. CESTR-quantified NOE (-3.5) has a weaker correlation with NOE (-3.5) fs than AREX-quantified NOE (-3.5). CONCLUSION: CESTR reflects a combined effect of T1 weighting and CEST/NOE. Both factors depend on fs , which contributes positively to the dependence of CESTR on fs in APT imaging and enhances its correlation with fs . In contrast, these factors have opposite contributions to its dependence on fs in NOE (-3.5) imaging, thereby weakening the correlation.


Assuntos
Neoplasias Encefálicas , Ratos , Animais , Neoplasias Encefálicas/patologia , Prótons , Imageamento por Ressonância Magnética/métodos , Amidas , Aumento da Imagem/métodos
4.
Magn Reson Med ; 89(6): 2432-2440, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36740894

RESUMO

PURPOSE: To quantify the variations of the power-law dependences on diffusion time t or gradient frequency f $$ f $$ of extracellular water diffusion measured by diffusion MRI (dMRI). METHODS: Model cellular systems containing only extracellular water were used to investigate the t / f $$ t/f $$ dependence of D ex $$ {D}_{ex} $$ , the extracellular diffusion coefficient. Computer simulations used a randomly packed tissue model with realistic intracellular volume fractions and cell sizes. DMRI measurements were performed on samples consisting of liposomes containing heavy water(D2 O, deuterium oxide) dispersed in regular water (H2 O). D ex $$ {D}_{ex} $$ was obtained over a broad t $$ t $$ range (∼1-1000 ms) and then fit power-law equations D ex ( t ) = D const + const · t - ϑ t $$ {D}_{ex}(t)={D}_{\mathrm{const}}+\mathrm{const}\cdotp {t}^{-{\vartheta}_t} $$ and D ex ( f ) = D const + const · f ϑ f $$ {D}_{ex}(f)={D}_{\mathrm{const}}+\mathrm{const}\cdotp {f}^{\vartheta_f} $$ . RESULTS: Both simulated and experimental results suggest that no single power-law adequately describes the behavior of D ex $$ {D}_{ex} $$ over the range of diffusion times of most interest in practical dMRI. Previous theoretical predictions are accurate over only limited t $$ t $$ ranges; for example, θ t = θ f = - 1 2 $$ {\theta}_t={\theta}_f=-\frac{1}{2} $$ is valid only for short times, whereas θ t = 1 $$ {\theta}_t=1 $$ or θ f = 3 2 $$ {\theta}_f=\frac{3}{2} $$ is valid only for long times but cannot describe other ranges simultaneously. For the specific t $$ t $$ range of 5-70 ms used in typical human dMRI measurements, θ t = θ f = 1 $$ {\theta}_t={\theta}_f=1 $$ matches the data well empirically. CONCLUSION: The optimal power-law fit of extracellular diffusion varies with diffusion time. The dependency obtained at short or long t $$ t $$ limits cannot be applied to typical dMRI measurements in human cancer or liver. It is essential to determine the appropriate diffusion time range when modeling extracellular diffusion in dMRI-based quantitative microstructural imaging.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Difusão , Modelos Biológicos , Simulação por Computador
5.
Magn Reson Imaging ; 94: 144-150, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36209946

RESUMO

BACKGROUND: It remains a clinical challenge to differentiate brain tumors from radiation-induced necrosis in the brain. Despite significant improvements, no single MRI method has been validated adequately in the clinical setting. METHODS: Multi-parametric MRI (mpMRI) was performed to differentiate 9L gliosarcoma from radiation necrosis in animal models. Five types of MRI methods probed complementary information on different scales i.e., T2 (relaxation), CEST based APT (probing mobile proteins/peptides) and rNOE (mobile macromolecules), qMT (macromolecules), diffusion based ADC (cell density) and SSIFT iAUC (cell size), and perfusion based DSC (blood volume and flow). RESULTS: For single MRI parameters, iAUC and ADC provide the best discrimination of radiation necrosis and brain tumor. For mpMRI, a combination of iAUC, ADC, and APT shows the best classification performance based on a two-step analysis with the Lasso and Ridge regressions. CONCLUSION: A general mpMRI approach is introduced to choosing candidate multiple MRI methods, identifying the most effective parameters from all the mpMRI parameters, and finding the appropriate combination of chosen parameters to maximize the classification performance to differentiate tumors from radiation necrosis.


Assuntos
Neoplasias Encefálicas , Imageamento por Ressonância Magnética Multiparamétrica , Lesões por Radiação , Animais , Meios de Contraste , Roedores , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Imageamento por Ressonância Magnética/métodos , Necrose/diagnóstico por imagem
6.
Adv Radiat Oncol ; 7(6): 101014, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36060637

RESUMO

Purpose: Our purpose was to develop a rodent model of brain radionecrosis using clinical linear accelerator based stereotactic radiosurgery. Methods and Materials: Single fraction maximum prescription points in the mouse's left hemisphere were irradiated using linear accelerator-based stereotactic radiosurgery with multiple arcs at 60 (n = 5), 100 (n = 5), and 140 (n = 5) Gy. Rats (n = 6) were similarly treated with 140 Gy. Gadolinium (Gd)-enhanced magnetic resonance imaging (MRI) was used to track radiation injury in mice over weeks (100 and 140 Gy) or months (60 Gy). Target accuracy was measured by the distance from the prescription point to the center of the earliest Gd-MRI enhancement. Confirmation of necrosis via histology was performed at the subject endpoints. Results: Radiation injury as indicated by Gd-MRI was first identified at 2 weeks (140 Gy), 4 to 6 weeks (100 Gy), and 8 months (60 Gy). A volumetric time course showed rapid growth in the volume of Gd-MRI signal enhancement after the appearance of apparent necrosis. Histopathologic features were consistent with radionecrosis. Conclusions: The presented method uses a commonly available clinical linear accelerator to induce radiation necrosis in both mice and rats. The treatment is modeled after patient therapy for a more direct model of human tissue under a range of doses used in clinical neuro-ablation techniques. The short time to onset of apparent necrosis, accurate targeting of the prescription point, high incidence of necrosis, and similar pathologic features make this a suitable animal model for further research in radionecrosis.

7.
Front Neurol ; 13: 811315, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35785345

RESUMO

Purpose: In this cross-sectional, proof-of-concept study, we propose that using the more pathologically-specific neurite orientation dispersion and density imaging (NODDI) method, in conjunction with high-resolution probabilistic tractography, white matter tract templates can improve the assessment of regional axonal injury and its association with disability of people with multiple sclerosis (pwMS). Methods: Parametric maps of the neurite density index, orientation dispersion index, and the apparent isotropic volume fraction (IVF) were estimated in 18 pwMS and nine matched healthy controls (HCs). Tract-specific values were measured in transcallosal (TC) fibers from the paracentral lobules and TC and corticospinal fibers from the ventral and dorsal premotor areas, presupplementary and supplementary motor areas, and primary motor cortex. The nonparametric Mann-Whitney U test assessed group differences in the NODDI-derived metrics; the Spearman's rank correlation analyses measured associations between the NODDI metrics and other clinical or radiological variables. Results: IVF values of the TC fiber bundles from the paracentral, presupplementary, and supplementary motor areas were both higher in pwMS than in HCs (p ≤ 0.045) and in pwMS with motor disability compared to those without motor disability (p ≤ 0.049). IVF in several TC tracts was associated with the Expanded Disability Status Scale score (p ≤ 0.047), while regional and overall lesion burden correlated with the Timed 25-Foot Walking Test (p ≤ 0.049). Conclusion: IVF alterations are present in pwMS even when the other NODDI metrics are still mostly preserved. Changes in IVF are biologically non-specific and may not necessarily drive irreversible functional loss. However, by possibly preceding downstream pathologies that are strongly associated with disability accretion, IVF changes are indicators of, otherwise, occult prelesional tissue injury.

8.
Cancer Res ; 82(19): 3603-3613, 2022 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-35877201

RESUMO

Brain metastasis is a common characteristic of late-stage lung cancers. High doses of targeted radiotherapy can control tumor growth in the brain but can also result in radiotherapy-induced necrosis. Current methods are limited for distinguishing whether new parenchymal lesions following radiotherapy are recurrent tumors or radiotherapy-induced necrosis, but the clinical management of these two classes of lesions differs significantly. Here, we developed, validated, and evaluated a new MRI technique termed selective size imaging using filters via diffusion times (SSIFT) to differentiate brain tumors from radiotherapy necrosis in the brain. This approach generates a signal filter that leverages diffusion time dependence to establish a cell size-weighted map. Computer simulations in silico, cultured cancer cells in vitro, and animals with brain tumors in vivo were used to comprehensively validate the specificity of SSIFT for detecting typical large cancer cells and the ability to differentiate brain tumors from radiotherapy necrosis. SSIFT was also implemented in patients with metastatic brain cancer and radiotherapy necrosis. SSIFT showed high correlation with mean cell sizes in the relevant range of less than 20 µm. The specificity of SSIFT for brain tumors and reduced contrast in other brain etiologies allowed SSIFT to differentiate brain tumors from peritumoral edema and radiotherapy necrosis. In conclusion, this new, cell size-based MRI method provides a unique contrast to differentiate brain tumors from other pathologies in the brain. SIGNIFICANCE: This work introduces and provides preclinical validation of a new diffusion MRI method that exploits intrinsic differences in cell sizes to distinguish brain tumors and radiotherapy necrosis.


Assuntos
Neoplasias Encefálicas , Lesões por Radiação , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Tamanho Celular , Diagnóstico Diferencial , Humanos , Imageamento por Ressonância Magnética/métodos , Necrose/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico , Lesões por Radiação/diagnóstico por imagem , Lesões por Radiação/etiologia
9.
NMR Biomed ; 35(12): e4799, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35794795

RESUMO

The goal of the current study is to include transcytolemmal water exchange in MR cell size imaging using the IMPULSED model for more accurate characterization of tissue cellular properties (e.g., apparent volume fraction of intracellular space v in ) and quantification of indicators of transcytolemmal water exchange. We propose a heuristic model that incorporates transcytolemmal water exchange into a multicompartment diffusion-based method (IMPULSED) that was developed previously to extract microstructural parameters (e.g., mean cell size d and apparent volume fraction of intracellular space v in ) assuming no water exchange. For t diff ≤ 5 ms, the water exchange can be ignored, and the signal model is the same as the IMPULSED model. For t diff ≥ 30 ms, we incorporated the modified Kärger model that includes both restricted diffusion and exchange between compartments. Using simulations and previously published in vitro cell data, we evaluated the accuracy and precision of model-derived parameters and determined how they are dependent on SNR and imaging parameters. The joint model provides more accurate d values for cell sizes ranging from 10 to 12 microns when water exchange is fast (e.g., intracellular water pre-exchange lifetime τ in ≤ 100 ms) than IMPULSED, and reduces the bias of IMPULSED-derived estimates of v in , especially when water exchange is relatively slow (e.g., τ in > 200 ms). Indicators of transcytolemmal water exchange derived from the proposed joint model are linearly correlated with ground truth τ in values and can detect changes in cell membrane permeability induced by saponin treatment in murine erythroleukemia cancer cells. Our results suggest this joint model not only improves the accuracy of IMPULSED-derived microstructural parameters, but also provides indicators of water exchange that are usually ignored in diffusion models of tissues.


Assuntos
Água Corporal , Camundongos , Animais , Água Corporal/metabolismo , Tamanho Celular , Permeabilidade da Membrana Celular , Difusão
10.
Magn Reson Imaging ; 92: 100-107, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35764217

RESUMO

PURPOSE: RACETE (refocused acquisition of chemical exchange transferred excitations) is a recently developed approach to imaging solute exchange with water. However, it lacks biophysical specificity, as it is sensitive to exchange rates, relaxation rates, solute concentration, and macromolecular content. We modified this sequence and developed a protocol and corresponding metric with specific sensitivity to the solute exchange rate and hence a means for mapping pH. THEORY AND METHODS: RACETE splits the two gradients traditionally used in a stimulated-echo sequence into one applied after exciting solutes and one applied after exciting water, hence requiring exchange for echo formation. In this work, we leverage the dependence of the stimulated-echo signal on the exchange process. By preserving the total irradiation power and using a ratio metric, the other signal dependencies cancel, leaving a specific measure of exchange rate. Additionally, artifacts due to off-resonance excitation of water are addressed using a phase cancelling approach; and a gradient-echo imaging sequence with a variable flip angle excitation is tailored for a fast read-out of RECETE prepared signals. This method is validated using numerical simulations and salicylic acid phantom experiments at 9.4 T. RESULTS: Numerical simulations and phantom experiments demonstrate that the ratio-metric is a single-variable function of exchange rate with extremely low dependence on confounding factors. Additionally, artifacts due to direct water excitation are removed and robustness to B0 and B1 inhomogeneities is demonstrated. CONCLUSION: The proposed method can be used for fast pH mapping with robustness against the confounding effects that widely exist in other methods.


Assuntos
Imageamento por Ressonância Magnética , Água , Concentração de Íons de Hidrogênio , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes
11.
Int J Radiat Oncol Biol Phys ; 113(5): 960-966, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35595157

RESUMO

PURPOSE: Effective treatment options for refractory depression are needed. Recent advancements permit both precise ablative radiation and functional neurologic connectome analysis using standard magnetic resonance imaging. We combined these innovations to perform stereotactic radiosurgical capsulotomy for the treatment of medically refractory major depressive disorder and study connectome response using a novel tractography-based approach. METHODS AND MATERIALS: Patients with medically refractory depression were enrolled on a prospective pilot single-arm observational trial from 2020 to 2021 at a single academic tertiary referral center. Bilateral ablation of the anterior limb of the internal capsule was accomplished by mask-based linear accelerator stereotactic radiosurgery. Beck's Depression Inventory measured efficacy. Montreal Cognitive Assessment evaluated cognition. RESULTS: Three patients were enrolled. Depression burden was improved by 88% at 12-month follow-up and by 55% at 18-month follow-up for patient 1 and 2, respectively. Patient 1 discontinued ketamine therapy, and patient 2 discontinued electroconvulsive therapy. Patient 3 reported global improvement in symptoms and function at 3 months. All 3 patients had reduction or resolution of suicidal ideation. No patient experienced cognitive decline or neurologic toxicity, and Montreal Cognitive Assessment score, as well as subjective patient-reported evaluations of concentration and attention, were superior after treatment. Tractography confirmed intended disruption of the cortico-striatal-thalamo-cortical loop with structural reorganization in the connectome. Connectome change was consistent between patients. Observed increases in caudate and putamen connectivity and decreases in thalamic connectivity may explain improved concentration, attention, and depression. The diversity and magnitude of connectome change may correlate with degree of clinical response. CONCLUSIONS: In 3 patients with refractory depression, radiosurgical capsulotomy significantly reduced the burden of depression. Functional connectome reorganization offers neurobiological evidence to support further investigations of the role of radiosurgery in depression.


Assuntos
Transtorno Depressivo Maior , Transtorno Depressivo Resistente a Tratamento , Transtorno Obsessivo-Compulsivo , Radiocirurgia , Transtorno Depressivo Maior/diagnóstico por imagem , Transtorno Depressivo Maior/cirurgia , Transtorno Depressivo Resistente a Tratamento/diagnóstico por imagem , Transtorno Depressivo Resistente a Tratamento/cirurgia , Imagem de Tensor de Difusão , Humanos , Imageamento por Ressonância Magnética , Transtorno Obsessivo-Compulsivo/patologia , Transtorno Obsessivo-Compulsivo/psicologia , Transtorno Obsessivo-Compulsivo/cirurgia , Estudos Prospectivos , Radiocirurgia/métodos
12.
Med Phys ; 49(1): 271-281, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34802148

RESUMO

PURPOSE: To develop a disposable point-of-care portable perfusion phantom (DP4) and validate its clinical utility in a multi-institutional setting for quantitative dynamic contrast-enhanced magnetic resonance imaging (qDCE-MRI). METHODS: The DP4 phantom was designed for single-use and imaged concurrently with a human subject so that the phantom data can be utilized as the reference to detect errors in qDCE-MRI measurement of human tissues. The change of contrast-agent concentration in the phantom was measured using liquid chromatography-mass spectrometry. The repeatability of the contrast enhancement curve (CEC) was assessed with five phantoms in a single MRI scanner. Five healthy human subjects were recruited to evaluate the reproducibility of qDCE-MRI measurements. Each subject was imaged concurrently with the DP4 phantom at two institutes using three 3T MRI scanners from three different vendors. Pharmacokinetic (PK) parameters in the regions of liver, spleen, pancreas, and paravertebral muscle were calculated based on the Tofts model (TM), extended Tofts model (ETM), and shutter speed model (SSM). The reproducibility of each PK parameter over three measurements was evaluated with the intraclass correlation coefficient (ICC) and compared before and after DP4-based error correction. RESULTS: The contrast-agent concentration in the DP4 phantom was linearly increased over 10 min (0.17 mM/min, measurement accuracy: 96%) after injecting gadoteridol (100 mM) at a constant rate (0.24 ml/s, 4 ml). The repeatability of the CEC within the phantom was 0.997 when assessed by the ICC. The reproducibility of the volume transfer constant, Ktrans , was the highest of the PK parameters regardless of the PK models. The ICCs of Ktrans in the TM, ETM, and SSM before DP4-based error correction were 0.34, 0.39, and 0.72, respectively, while those increased to 0.93, 0.98, and 0.86, respectively, after correction. CONCLUSIONS: The DP4 phantom is reliable, portable, and capable of significantly improving the reproducibility of qDCE-MRI measurements.


Assuntos
Meios de Contraste , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Imageamento por Ressonância Magnética , Perfusão , Reprodutibilidade dos Testes
13.
J Neuroimaging ; 31(5): 1003-1013, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34033187

RESUMO

BACKGROUND AND PURPOSE: Axonal injury is a key player of disability in persons with multiple sclerosis (pwMS). Yet, detecting and measuring it in vivo is challenging. The neurite orientation dispersion and density imaging (NODDI) proposes a novel framework for probing axonal integrity in vivo. NODDI at 3.0 Tesla was used to quantify tissue damage in pwMS and its relationship with disease progression. METHODS: Eighteen pwMS (4 clinically isolated syndrome, 11 relapsing remitting, and 3 secondary progressive MS) and nine age- and sex-matched healthy controls underwent a brain MRI, inclusive of clinical sequences and a multi-shell diffusion acquisition. Parametric maps of axial diffusivity (AD), neurite density index (ndi), apparent isotropic volume fraction (ivf), and orientation dispersion index (odi) were fitted. Anatomically matched regions of interest were used to quantify AD and NODDI-derived metrics and to assess the relations between these measures and those of disease progression. RESULTS: AD, ndi, ivf, and odi significantly differed between chronic black holes (cBHs) and T2-lesions, and between the latter and normal appearing white matter (NAWM). All metrics except ivf significantly differed between NAWM located next to a cBH and that situated contra-laterally. Only NAWM odi was significantly associated with T2-lesion volume, the timed 25-foot walk test and disease duration. CONCLUSIONS: NODDI is sensitive to tissue injury but its relationship with clinical progression remains limited.


Assuntos
Lesões Encefálicas , Esclerose Múltipla , Substância Branca , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética , Neuritos
14.
Mult Scler Relat Disord ; 49: 102738, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33609957

RESUMO

BACKGROUND: Axonal injury is the primary source of irreversible neurological decline in persons with multiple sclerosis (pwMS). Identifying and quantifying myelin and axonal loss in lesional and perilesional tissue in vivo is fundamental for a better understanding of multiple sclerosis (MS) outcomes and patient impairment. Using advanced magnetic resonance imaging (MRI) methods, consisting of selective inversion recovery quantitative magnetization transfer imaging (SIR-qMT) and multi-compartment diffusion MRI with the spherical mean technique (SMT), we conducted a cross-sectional pilot study to assess myelin and axonal damage in the normal appearing white matter (NAWM) surrounding chronic black holes (cBHs) and how this pathology correlates with disability in vivo. We hypothesized that lesional axonal transection propagates tissue injury in the surrounding NAWM and that the degree of this injury is related to patient disability. METHODS: Eighteen pwMS underwent a 3.0 Tesla conventional clinical MRI, inclusive of T1 and T2 weighted protocols, as well as SIR-qMT and SMT. Regions of interests (ROIs) were manually delineated in cBHs, NAWM neighboring cBHs (perilesional NAWM), distant ipsilateral NAWM and contra-lateral distant NAWM. SIR-qMT-derived macromolecular-to-free pool size ratio (PSR) and SMT-derived apparent axonal volume fraction (Vax) were extracted to infer on myelin and axonal content, respectively. Group differences were assessed using mixed-effects regression models and correlation analyses were obtained by bootstrapping 95% confidence interval. RESULTS: In comparison to perilesional NAWM, both PSR and Vax values were reduced in cBHs (p < 0.0001) and increased in distant contra-lateral NAWM ROIs (p < 0.001 for PSR and p < 0.0001 for Vax) but not ipsilateral NAWM (p = 0.176 for PSR and p = 0.549 for Vax). Vax values measured in cBHs correlated with those in perilesional NAWM (Pearson rho = 0.63, p < 0.001). No statistically relevant associations were seen between PSR/Vax values and clinical and/or MRI metrics of the disease with the exception of cBH PSR values, which correlated with the Expanded Disability Status Scale (Pearson rho = -0.63, p = 0.03). CONCLUSIONS: Our results show that myelin and axonal content, detected by PSR and Vax, are reduced in perilesional NAWM, as a function of the degree of focal cBH axonal injury. This finding is indicative of an ongoing anterograde/retrograde degeneration and suggests that treatment prevention of cBH development is a key factor for preserving NAWM integrity in surrounding tissue. It also suggests that measuring changes in perilesional areas over time may be a useful measure of outcome for proof-of-concept clinical trials on neuroprotection and repair. PSR and Vax largely failed to capture associations with clinical and MRI characteristics, likely as a result of the small sample size and cross-sectional design, however, longitudinal assessment of a larger cohort may unravel the impact of this pathology on disease progression.


Assuntos
Esclerose Múltipla , Substância Branca , Encéfalo , Estudos Transversais , Humanos , Imageamento por Ressonância Magnética , Esclerose Múltipla/complicações , Esclerose Múltipla/diagnóstico por imagem , Bainha de Mielina , Projetos Piloto , Substância Branca/diagnóstico por imagem
15.
J Neurosci Methods ; 349: 109024, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33333089

RESUMO

The detection sensitivity of diffusion MRI (dMRI) is dependent on diffusion times. A shorter diffusion time can increase the sensitivity to smaller length scales. However, the conventional dMRI uses the pulse gradient spin echo (PGSE) sequence that probes relatively long diffusion times only. To overcome this, the oscillating gradient spin echo (OGSE) sequence has been developed to probe much shorter diffusion times with hardware limitations on preclinical and clinical MRI systems. The OGSE sequence has been previously used on preclinical animal MRI systems. Recently, several studies have translated the OGSE sequence to humans on clinical MRI systems and achieved new information that is invisible using conventional PGSE sequence. This paper provides an overview of the recent progress of the OGSE neuroimaging in humans, including the technical improvements in the translation of the OGSE sequence to human imaging and various applications in different neurological disorders and stroke. Some possible future directions of the OGSE sequence are also discussed.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neuroimagem , Animais , Difusão , Humanos , Imageamento por Ressonância Magnética
16.
Magn Reson Imaging ; 77: 109-123, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33338562

RESUMO

Cytological features such as cell size and intracellular morphology provide fundamental information on cell status and hence may provide specific information on changes that arise within biological tissues. Such information is usually obtained by invasive biopsy in current clinical practice, which suffers several well-known disadvantages. Recently, novel MRI methods such as IMPULSED (imaging microstructural parameters using limited spectrally edited diffusion) have been developed for direct measurements of mean cell size non-invasively. The IMPULSED protocol is based on using temporal diffusion spectroscopy (TDS) to combine measurements of water diffusion over a wide range of diffusion times to probe cellular microstructure over varying length scales. IMPULSED has been shown to provide rapid, robust, and reliable mapping of mean cell size and is suitable for clinical imaging. More recently, cell size distributions have also been derived by appropriate analyses of data acquired with IMPULSED or similar sequences, which thus provides MRI-cytometry. This review summarizes the basic principles, practical implementations, validations, and example applications of MR cell size imaging based on TDS and demonstrates how cytometric information can be used in various applications. In addition, the limitations and potential future directions of MR cytometry are identified including the diagnosis of nonalcoholic steatohepatitis of the liver and the assessment of treatment response of cancers.


Assuntos
Tamanho Celular , Análise Espectral , Difusão , Humanos , Imageamento por Ressonância Magnética
17.
Magn Reson Med ; 85(2): 748-761, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32936478

RESUMO

PURPOSE: This report introduces and validates a new diffusion MRI-based method, termed MRI-cytometry, which can noninvasively map intravoxel, nonparametric cell size distributions in tissues. METHODS: MRI was used to acquire diffusion MRI signals with a range of diffusion times and gradient factors, and a model was fit to these data to derive estimates of cell size distributions. We implemented a 2-step fitting method to avoid noise-induced artificial peaks and provide reliable estimates of tumor cell size distributions. Computer simulations in silico, experimental measurements on cultured cells in vitro, and animal xenografts in vivo were used to validate the accuracy and precision of the method. Tumors in 7 patients with breast cancer were also imaged and analyzed using this MRI-cytometry approach on a clinical 3 Tesla MRI scanner. RESULTS: Simulations and experimental results confirm that MRI-cytometry can reliably map intravoxel, nonparametric cell size distributions and has the potential to discriminate smaller and larger cells. The application in breast cancer patients demonstrates the feasibility of direct translation of MRI-cytometry to clinical applications. CONCLUSION: The proposed MRI-cytometry method can characterize nonparametric cell size distributions in human tumors, which potentially provides a practical imaging approach to derive specific histopathological information on biological tissues.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Animais , Tamanho Celular , Simulação por Computador , Difusão , Humanos
18.
Neuroimage ; 227: 117619, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-33301942

RESUMO

Noninvasive estimation of mean axon diameter presents a new opportunity to explore white matter plasticity, development, and pathology. Several diffusion-weighted MRI (DW-MRI) methods have been proposed to measure the average axon diameter in white matter, but they typically require many diffusion encoding measurements and complicated mathematical models to fit the signal to multiple tissue compartments, including intra- and extra-axonal spaces. Here, Monte Carlo simulations uncovered a straightforward DW-MRI metric of axon diameter: the change in radial apparent diffusion coefficient estimated at different effective diffusion times, ΔD⊥. Simulations indicated that this metric increases monotonically within a relevant range of effective mean axon diameter while being insensitive to changes in extra-axonal volume fraction, axon diameter distribution, g-ratio, and influence of myelin water. Also, a monotonic relationship was found to exist for signals coming from both intra- and extra-axonal compartments. The slope in ΔD⊥ with effective axon diameter increased with the difference in diffusion time of both oscillating and pulsed gradient diffusion sequences.


Assuntos
Axônios , Imagem de Difusão por Ressonância Magnética/métodos , Substância Branca/diagnóstico por imagem , Algoritmos , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Método de Monte Carlo
19.
Magn Reson Imaging ; 74: 56-63, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32898649

RESUMO

BACKGROUND: The multi-compartment diffusion MRI using the spherical mean technique (SMT) has been suggested to enhance the pathological specificity to tissue injury in multiple sclerosis (MS) imaging, but its accuracy and precision have not been comprehensively evaluated. METHODS: A Cramer-Rao Lower Bound method was used to optimize an SMT protocol for MS imaging. Finite difference computer simulations of spins in packed cylinders were then performed to evaluate the influences of five realistic pathological features in MS lesions: axon diameter, axon density, free water fraction, axonal crossing, dispersion, and undulation. RESULTS: SMT derived metrics can be biased by some confounds of pathological variations, such as axon size and free water fraction. However, SMT in general provides valuable information to characterize pathological features in MS lesions with a clinically feasible protocol. CONCLUSION: SMT may be used as a practical MS imaging method and should be further improved in clinical MS imaging.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Axônios/patologia , Humanos , Processamento de Imagem Assistida por Computador , Esclerose Múltipla/patologia
20.
J Immunother Cancer ; 8(1)2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32581044

RESUMO

BACKGROUND: Immune checkpoint inhibitors, the most widespread class of immunotherapies, have demonstrated unique response patterns that are not always adequately captured by traditional response criteria such as the Response Evaluation Criteria in Solid Tumors or even immune-specific response criteria. These response metrics rely on monitoring tumor growth, but an increase in tumor size and/or appearance after starting immunotherapy does not always represent tumor progression, but also can be a result of T cell infiltration and thus positive treatment response. Therefore, non-invasive and longitudinal monitoring of T cell infiltration are needed to assess the effects of immunotherapies such as checkpoint inhibitors. Here, we proposed an innovative concept that a sufficiently large influx of tumor infiltrating T cells, which have a smaller diameter than cancer cells, will change the diameter distribution and decrease the average size of cells within a volume to a degree that can be quantified by non-invasive MRI. METHODS: We validated our hypothesis by studying tumor response to combination immune-checkpoint blockade (ICB) of anti-PD-1 and anti-CTLA4 in a mouse model of colon adenocarcinoma (MC38). The response was monitored longitudinally using Imaging Microstructural Parameters Using Limited Spectrally Edited Diffusion (IMPULSED), a diffusion MRI-based method which has been previously shown to non-invasively map changes in intracellular structure and cell sizes with the spatial resolution of MRI, in cell cultures and in animal models. Tumors were collected for immunohistochemical and flow cytometry analyzes immediately after the last imaging session. RESULTS: Immunohistochemical analysis revealed that increased T cell infiltration of the tumors results in a decrease in mean cell size (eg, a 10% increase of CD3+ T cell fraction results a ~1 µm decrease in the mean cell size). IMPULSED showed that the ICB responders, mice with tumor volumes were less than 250 mm3 or had tumors with stable or decreased volumes, had significantly smaller mean cell sizes than both Control IgG-treated tumors and ICB non-responder tumors. CONCLUSIONS: IMPULSED-derived cell size could potentially serve as an imaging marker for differentiating responsive and non-responsive tumors after checkpoint inhibitor therapies, a current clinical challenge that is not solved by simply monitoring tumor growth.


Assuntos
Inibidores de Checkpoint Imunológico/uso terapêutico , Linfócitos do Interstício Tumoral/imunologia , Imageamento por Ressonância Magnética/métodos , Linfócitos T/imunologia , Animais , Modelos Animais de Doenças , Feminino , Humanos , Inibidores de Checkpoint Imunológico/farmacologia , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...