1.
Int J Numer Method Biomed Eng ; 39(6): e3705, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37005088

RESUMO

Extracorporeal membrane oxygenation (ECMO) is a life support system used in the treatment of severe respiratory and circulatory failure. High shear stress caused by the high rotational speed of centrifugal blood pumps can cause hemolysis and platelet activation, which are among the major factors leading to the complications of the ECMO system. In this study, a novel blood pump named rotary displacement blood pump (RDBP), which can considerably reduce rotational speed and shear stress while ensuring the normal pressure flow relationship, was proposed. We employed computational fluid dynamics (CFD) analysis to investigate the performance of RDBP under adult ECMO support operating conditions (5 L/min with 350 mmHg). The efficiency and H-Q curves of the RDBP were calculated to evaluate its hydraulic performance, and pressure, flow patterns, and shear stress distribution were analyzed to estimate the hemodynamic characteristics in the pump. In addition, the modified index of hemolysis (MIH) was calculated for the RDBP based on a Eulerian approach. The hydraulic efficiency of the RDBP was 47.28%. The velocity distribution of flow field in the pump was relatively uniform. Most of the liquid (more than 75%) in the pump was exposed to low scale shear stress (<1 Pa), which was close to normal physiological conditions. The gap area was the main distribution location of high scale shear stress. The high wall shear stress (>9 Pa) volume fraction of the RDBP was small and located in the boundary areas between the rotor's edge and the housing. The MIH value of the RDBP was 9.87 ± 0.93 (mean ± SD). The RDBP can achieve better hydraulic efficiency and hemodynamic performance at lower rotational speed. The design of this novel pump is expected to provide a new direction for developing a blood pump for ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Humanos , Desenho de Equipamento , Hemólise , Hemodinâmica/fisiologia
2.
Comput Methods Programs Biomed ; 215: 106617, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35021137

RESUMO

BACKGROUND AND OBJECTIVE: Coil embolization has become a new treatment method for pulsatile tinnitus (PT) caused by sigmoid sinus diverticulum (SSD). Although this therapy has achieved good results in clinical reports, the hemodynamic mechanism of coils in the treatment of PT in SSD remained unclear. METHODS: Finite element method (FEM) and computational fluid dynamics (CFD) were combined to explore the hemodynamic mechanism of coil embolization in SSD treatment. Three personalized geometric models of sigmoid sinus were established according to the CTA data of patients. Coil model were established by FEM, and the hemodynamic differences of SSD before and after coiling were compared by transient CFD method. RESULTS: Velocity streamlines disappeared in the SSD after coiling. At the peak time (t1 = 0.22 s), the SSD-average velocity decreased in every patient. The average value of the decreased in three patients was 0.154 ± 0.028 m/s (mean ± SD). Wall average pressure (Pavg) also showed a decline in every patient. Average of decrements of three patients was 17.69 ± 4.91 Pa (mean ± SD). Average WSS (WSSavg) was also reduced in every patient. The average value of WSS drop was 9.74 ± 3.02 Pa (mean ± SD). After coiling, the proportion of low-velocity region in the sigmoid sinus cortical plate dehiscence (SSCPD) area increased. Average of increments was 22.1 ± 5.36% (mean ± SD). CONCLUSIONS: A reduction in SSD-average velocity, wall pressure, and WSS were the short-term hemodynamic mechanism of coil embolization for PT. Coil embolization increased the proportion of low-velocity region in the SSCPD area, thereby creating a hemodynamic environment that easily produced thrombus and protects blood vessels from the impact of blood flow. This phenomenon was the long-term effect of coil embolization.


Assuntos
Divertículo , Zumbido , Cavidades Cranianas , Divertículo/complicações , Hemodinâmica , Humanos , Hidrodinâmica , Zumbido/etiologia , Zumbido/terapia