Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Chinese Medical Journal ; (24): 172-180, 2024.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-1007740

RESUMO

BACKGROUND@#Oral anti-coagulants (OAC) are the intervention for the prevention of stroke, which consistently improve clinical outcomes and survival among patients with atrial fibrillation (AF). The main purpose of this study is to identify problems in OAC utilization among hospitalized patients with AF in China.@*METHODS@#Using data from the Improving Care for Cardiovascular Disease in China-Atrial Fibrillation (CCC-AF) registry, guideline-recommended OAC use in eligible patients was assessed.@*RESULTS@#A total of 52,530 patients with non-valvular AF were enrolled from February 2015 to December 2019, of whom 38,203 were at a high risk of stroke, 9717 were at a moderate risk, and 4610 were at a low risk. On admission, only 20.0% (6075/30,420) of patients with a diagnosed AF and a high risk of stroke were taking OAC. The use of pre-hospital OAC on admission was associated with a lower risk of new-onset ischemic stroke/transient ischemic attack among the diagnosed AF population (adjusted odds ratio: 0.54, 95% confidence interval: 0.43-0.68; P  <0.001). At discharge, the prescription rate of OAC was 45.2% (16,757/37,087) in eligible patients with high stroke risk and 60.7% (2778/4578) in eligible patients with low stroke risk. OAC utilization in patients with high stroke risk on admission or at discharge both increased largely over time (all P  <0.001). Multivariate analysis showed that OAC utilization at discharge was positively associated with in-hospital rhythm control strategies, including catheter ablation (adjusted odds ratio [OR] 11.63, 95% confidence interval [CI] 10.04-13.47; P <0.001), electronic cardioversion (adjusted OR 2.41, 95% CI 1.65-3.51; P <0.001), and anti-arrhythmic drug use (adjusted OR 1.45, 95% CI 1.38-1.53; P <0.001).@*CONCLUSIONS@#In hospitals participated in the CCC-AF project, >70% of AF patients were at a high risk of stroke. Although poor performance on guideline-recommended OAC use was found in this study, over time the CCC-AF project has made progress in stroke prevention in the Chinese AF population.Registration:ClinicalTrials.gov, NCT02309398.


Assuntos
Humanos , Administração Oral , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Alta do Paciente , Pacientes , Sistema de Registros , Fatores de Risco , Acidente Vascular Cerebral/tratamento farmacológico
2.
Chinese Medical Journal ; (24): 2451-2458, 2023.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-1007688

RESUMO

BACKGROUND@#The age, biomarkers, and clinical history (ABC)-atrial fibrillation (AF)-Stroke score have been proposed to refine stroke risk stratification, beyond what clinical risk scores such as the CHA2DS2-VASc score can offer. This study aimed to identify risk factors associated with thromboembolism and evaluate the performance of the ABC-AF-Stroke score in predicting thromboembolism in non-anticoagulated AF patients following successful ablations.@*METHODS@#A total of 2692 patients who underwent successful ablations with discontinued anticoagulation after a 3-month blanking period in the Chinese Atrial Fibrillation Registry (CAFR) between 2013 and 2019 were included. Cox regression analysis was conducted to present the association of risk factors with thromboembolism risk. The ABC-AF-Stroke score was evaluated in terms of discrimination, including concordance index (C-index), net reclassification improvement (NRI) and integrated discrimination improvement (IDI), clinical utilization by decision curve analysis (DCA), and calibration by comparing the predicted risk with the observed annualized event rate.@*RESULTS@#After a median follow-up of 3.5 years, 64 patients experienced thromboembolism events. Age, prior history of stroke/transient ischemic attack (TIA), high-sensitivity cardiac troponin T (cTnT-hs), and N-terminal pro-B-type natriuretic peptide (NT-proBNP) were independently associated with thromboembolism risk. The ABC-AF-Stroke score performed statistically significantly better than the CHA2DS2-VASc score in terms of C-index (0.67, 95% confidence interval [CI]: 0.59-0.74 vs. 0.60, 95% CI: 0.52-0.67, P = 0.030) and reclassification capacity. The DCA implied that the ABC-AF-Stroke score could identify more thromboembolism events without increasing the false positive rate compared to the CHA2DS2-VASc score. The calibration curve showed that the ABC-AF-Stroke score was well calibrated in this population.@*CONCLUSIONS@#In this real-world study enrolling non-anticoagulated AF patients following successful ablations, age, prior history of stroke/TIA, level of NT-proBNP, and cTnT-hs were independently associated with an increased risk of thromboembolism. The ABC-AF-Stroke score was well-calibrated and statistically significantly outperformed the CHA2DS2-VASc score in predicting thromboembolism risk.


Assuntos
Humanos , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , População do Leste Asiático , Ataque Isquêmico Transitório , Sistema de Registros , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Tromboembolia/etiologia , Troponina T
3.
Chinese Journal of Cardiology ; (12): 595-601, 2019.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-805705

RESUMO

Objectives@#This study explored the relationship between weight control and atrial fibrillation (AF) recurrence after catheter ablation in overweight and obese patients.@*Methods@#We prospectively enrolled consecutive 333 overweight and obese patients aged 28 to 87 years old, who underwent catheter ablation for AF in Beijing Anzhen Hospital between October 2015 and February 2016. Data of patients′ characteristics, laboratory examination and treatment were collected at baseline. Each patient was followed up at 3, 6 and 12 months after ablation to collect information on weight, AF recurrence, stroke, major bleeding, hospitalization for cardiovascular reasons and death, etc. Patients were divided into weight controlled group (ΔBMI<-1 kg/m2) and weight uncontrolled group (ΔBMI≥-1 kg/m2), according to the changes in the most recent exposure BMI before AF recurrence in patients with recurrence or the BMI at 12 months′ follow-up in patients without recurrence and the BMI at baseline. Multivariate logistic regression was performed to adjust other known risk factors of AF recurrence and to explore the association between weight control and AF recurrence after catheter ablation.@*Results@#There were 54 patients in weight controlled group and 279 patients in weight uncontrolled group. There were no significant differences in age, gender, education level, left atrial size and history of hypertension between the two groups (all P>0.05). The proportion of patients using angiotensin-converting enzyme inhibitors/angiotensin receptor blockers was higher in the weight controlled group (50.0%(27/54) vs. 34.8%(97/279), P=0.034). However, there was no significant difference in the proportion of patients with obesity (33.3% (18/54) vs. 29.7% (83/279)), paroxysmal AF (59.3% (32/54) vs. 56.6% (158/279)) and AF duration less than 5 years (76.9% (40/52) vs. 65.4% (178/272)) between the weight controlled group and the uncontrolled group. During 1-year follow-up after ablation, the recurrence rate of AF was significantly lower in the weight controlled group than that in the weight uncontrolled group (14.8% (8/54) vs. 32.6%(91/279), P=0.009). Multivariable logistic regression analysis shows that weight control is independently associated with a lower postoperative AF recurrence rate (OR=0.40, 95%CI 0.18-0.90, P=0.026).@*Conclusion@#Weight control is strongly associated with a lower AF recurrence rate after catheter ablation in overweight and obese patients.

4.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-615628

RESUMO

Objective The recurrence of perimitral atrial tachycardia is common after initial ablation of persistent atrial fibrillation (AF). The aim of the study is to explore a preferable ablation approach for perimitral atrial tachycardia in the redo ablation of persistent AF. Methods Seventy-four patients with perimitral atrial tachycardia after initial ablation for persistent AF were included in our study. Patients were distinguished into either the group of having ablation during tachycardia (Group A) or the group having ablation after cardioversion to sinus rhythm (Group B) according to the different ablation strategies. The procedural endpoints were pulmonary vein isolation and bidirectional conduction block of all the ablated lines. The primary endpoint of the study was freedom from atrial tachyarrhythmia recurrence during the follow-up period. Results There were statistical differences in baseline clinical data between the 2 groups. During the redo procedure, conduction recovery rate across the mitral isthmus (MI),cavotricuspid isthmus and left atial roofline were 100%, 40.5% and 48.6% respectively. The procedural time, fluoroscopy time, mapping time were longer in the patients of group A. During a mean follow-up of (16.9±6.3) months, 31 (72.1%) patients in group A and 21(67.7%) patients in group B maintained in sinus rhythm in the absence of antiarrhythmic durgs (P =0.771) . Conclusion In patients with perimitral atrial tachycardia after initial ablation for persistent AF,ablation in sinus rhythm is a more simplified method and as effective as ablation during tachycardia.

5.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-611370

RESUMO

Objective Cryoballoon ablation of pulmonary vein (PV) ostia often induces a vagal response.This prospective study was designed to assess the effectiveness of prophylactic intravenous administration of atropine on hemodynamic impairment induced by cryoballoon ablation in patients with atrial fibrillation.Methods Twenty-five patients with paroxysmal atrial fibrillation undergoing cryoballoon ablation were prospectively enrolled and assigned to either the trial group on the control group.First twelve patients (the trial group) were administered 1 mg of atropine before deflation of the cryoballoon,while the following 13 patients (the control group) were given atropine only after the onset of the hemodynamic variation (decrease in heart rate and/or blood pressure).Treatment was considered effective when the hemodynamic variations were restored.Results In the trial group,three patients with transient hypotension did not require further supportive care throughout the procedures and one patient with hypotension required supportive management.In the control group,hypotension,bradycardia and mixed bradycardia with hypotension requiring supportive care occurred in six,three,and three patients,respectively.Overall,the rate of marked vagal responses was significantly lower when prophylactic atropine was administrated (4/12 vs.12/13 patients,P < 0.01).Conclusions Atropine is effective in the prevention of all types of vasovagal responses induced by cryoballoon ablation in patients with atrial fibrillation.

6.
Chinese Medical Journal ; (24): 1033-1038, 2014.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-253203

RESUMO

<p><b>BACKGROUND</b>Neutrophil/lymphocyte ratio (NLR) has been proposed as a novel marker of systemic inflammation and oxidative stress. The objective of this study was to ascertain the relationship between levels of NLR and recurrence of lone atrial fibrillation (AF) after catheter ablation.</p><p><b>METHODS</b>A total of 379 lone AF patients who underwent catheter ablation were enrolled in the study. The NLR before and after catheter ablation was determined. Cox regression analyses were used to estimate the relationship between NLR and the recurrence of lone AF.</p><p><b>RESULTS</b>After a mean follow-up of (30.5 ± 5.3) months, 124 (32.7%) patients had AF recurrences. The patients who developed AF recurrence had a higher postablation NLR (post-NLR) than patients with no recurrence (5.74 ± 1.55 vs. 4.66 ± 1.27, P < 0.001). Multivariate Cox regression analysis revealed that post-NLR (hazard ratio (HR) 1.514, 95% confidence interval (CI) 1.364-1.680, P < 0.001), left atrium diameter (HR 1.035, 95% CI 1.001-1.071, P = 0.04) and body mass index (HR 1.028, 95% CI 1.002-1.054, P = 0.03) were independent predictors of AF recurrence. Using a cut-off level of 5.15, post-NLR predicted AF recurrence with a sensitivity of 73% and specificity of 67%.</p><p><b>CONCLUSIONS</b>Our results indicate that an elevated post-NLR is associated with a high rate of lone AF recurrence. A simple measurement of NLR may help us to identify high-risk patients who need pharmacologic intervention to prevent recurrence.</p>


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial , Cirurgia Geral , Ablação por Cateter , Linfócitos , Alergia e Imunologia , Neutrófilos , Alergia e Imunologia , Modelos de Riscos Proporcionais
7.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-451327

RESUMO

Objective To identify the electrophysiological charateristics and cause of ridge gap related reentry after MI ablation in atrial ifbrillation patients. Methods Activation and entrainment mapping was performed in 82 redo cases for OAT recurrence in whom MI was ablated during the index produre. Once ridge gap related reentry was conifrmed, detailed mapping was performed in MI and ridge region. In addition, in 36 cases undergoing MI ablation and fulfilling criterion for bidirectional block, differential pacing was repeated at the ridge to identify a ridge gap. Results Out of 82 redo cases for OAT recurrence in whom MI was ablated during the index produre, 7 (8.5%) was found to be ridge gap related reentry. TCL was (247.9±19.2) ms, and the left atrial endocardial activation time was (145.4±17.7) ms, accounting for (58.5±3.2)%of TCL. However, wide double potential was recorded along the previous ablated MI line where PPI was (34.3±6.6) ms longer than TCL, while PPI was signiifcantly shorter at the ridge[PPI-TCL (11.4±3.9) ms, P<0.001]. Tachycardia was terminated at the ridge in 6 cases and at the corresponding site in coronary sinus in 1 case. No recurrence was found during follow-up for (11.1±4.5) months. In addition, in 36 patients undergoing MI ablation in whom criterion of bi-directional block was fuliflled, conduction gap located at the ridge was found in 5 (13.9%) cases. Conclusions MI ridge gap related reentry is a distinctive OAT, in which the ridge was used as the critical isthmus, whereas the previous ablated MI line is not part of the reentry. MI pseudo-block due to the ridge gap may lead to this type of recurrent tachycardia.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...