Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Exp Nephrol ; 28(8): 773-783, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38506981

RESUMO

BACKGROUND: Agonal bacteremia, diagnosed with postmortem positive blood culture results, is considered a possible contributing factor to death. We hypothesized that some premortem organ damage, such as kidney damage, can enhance agonal bacteremia. METHODS: We performed a postmortem blood and alveolar fluid culture study in 30 cadavers and evaluated the relationship between blood culture results and clinical parameters, including organ damage (brain, heart, lung, kidney, liver and gastrointestinal tract). RESULTS: A total of 23 cases (76.7%) were positive for blood culture; the number of cultured species was one in 12 cases, two in 7 cases, and three in 4 cases. The ratio of agonal bacteremia was significantly higher in patients with heart damage (100%, n = 13) and those with kidney damage (end-stage kidney damage, acute kidney injury, obstructive kidney failure, or metastatic kidney tumours) (100%, n = 13). The mean number of cultured species was 0.67 ± 0.98 in heart or kidney damage, 1.40 ± 0.55 in heart damage only, 1.40 ± 0.55 in kidney damage only, and 2.00 ± 0.93 in heart and kidney damage. As the number of damaged organs increased (0 organs, no heart/kidney damage; 1 organ, heart or kidney damage; and 2 organs, heart and kidney damage), the mean number of cultured species increased significantly (p for trend = 0.001964). CONCLUSION: Premortem kidney damage relates to agonal bacteremia.


Assuntos
Bacteriemia , Humanos , Bacteriemia/microbiologia , Estudos Retrospectivos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Adulto , Nefropatias/microbiologia , Hemocultura , Cadáver , Rim/patologia
2.
J Infect Chemother ; 29(1): 115-117, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36183991

RESUMO

TRCReady® SARS-CoV-2 i is a reagent for transcription-reverse transcription concerted reaction (TRC) to detect SARS-CoV-2 N2 gene, used with the automated rapid isothermal nucleic acid amplification test (NAAT) analyzer TRCReady®-80. Sensitivity and specificity of TRCReady® SARS-CoV-2 i was assessed by comparison with the results of real-time reverse transcription-polymerase chain reaction (RT-PCR) using nasopharyngeal swab samples. From November 2020 to March 2021, a total of 441 nasopharyngeal swabs were obtained and analyzed both with TRCReady® SARS-CoV-2 i and RT-PCR. Sensitivity and specificity of TRCReady® SARS-CoV-2 i were 94.6% (53/56) and 99.2% (382/385), respectively. Reaction time to positivity of TRCReady® SARS-CoV-2 i ranged from 1.166 to 9.805 (median: 2.887) min, and minimum detection sensitivity of TRCReady® SARS-CoV-2 i was 9 copies per test, with reaction time as 5.014 min. Detection of SARS-CoV-2 gene from nasopharyngeal swab sample using TRCReady® SARS-CoV-2 i shows comparative diagnostic test accuracy with RT-PCR, and can be used as a useful test to diagnose SARS-CoV-2 infection.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Transcrição Reversa , Indicadores e Reagentes , Testes Diagnósticos de Rotina , Sensibilidade e Especificidade , Nasofaringe
3.
Rinsho Byori ; 64(9): 1012-1015, 2016 09.
Artigo em Japonês | MEDLINE | ID: mdl-30609453

RESUMO

Macroprolactin is mostly a complex of monomeric prolactin (PRL) with IgG and considered to be biological inactive. Its presence commonly leads to diagnostic confusion and misdiagnosis. Polyethylene-glycol (PEG) precipitation method is widely used for a screening of macroprolactinemia. We applied PEG precipi- tation method for 200 samples which was ordered test of PRL. The PRL recovery was 65.0±11.2% (mean ±SD). In our data, PRL recovery less than 42.5% (mean-2SD) indicates the presence of macroprolactin. The prevalence of macroprolactinemia was 4.5%(9/197) in total samples and 9.5%(2/21) in hyperprolac- tinemia. Our result indicates the need for PEG screening for macroprolactinemia to avoid misdiagnosis. [Short Communication].


Assuntos
Hiperprolactinemia/diagnóstico , Prolactina/sangue , Adulto , Idoso , Feminino , Humanos , Programas de Rastreamento , Pessoa de Meia-Idade , Polietilenoglicóis/química
4.
Rinsho Byori ; 62(8): 755-60, 2014 Aug.
Artigo em Japonês | MEDLINE | ID: mdl-25669026

RESUMO

We evaluated the performance of a newly-improved estradiol(E2) assay reagent (NEW LP-E2-N), which replaces murine monoclonal antibody in the present reagent (LP-E2-N) with sheep monoclonal antibody, since we had experienced discrepant E2 assay results between LP-E2-N and other commercially available E2 assay kits. Several examinations with the new assay reagent indicated a good performance in terms of the limit of quantity, reproducibility (within-run and between-day), dilution linearity, and influence of blood components except hemoglobin. Using analogues and/or metabolites of E2, low or no cross-reactivity has been shown in NEW LP-E2-N: 0.26% with 25 ng/mL of estrone (El), 0.14% with 100 ng/mL of estradiol-3-sulfate, 0.02% with 200 ng/mL of 17α-ethynylestradiol, and less than 0.001% with 100 ng/mL of estriol(E3), estra-17-glucuronide, and estramustine, respectively. Although discrepant results between NEW LP-E2-N and LP-E2-N were observed in 12 samples, including 9 cases under oral hormone therapy, data from these samples were similar to those using 2 commercially available E2 assay kits, Architect and Eclusys, suggesting that the NEW LP E2-N shows adequate clinical efficacy. A correlation study was performed with LP E2-N, Architect, and Eclusys using 149 serum samples obtained from patients and healthy volunteers, and the correlation results were as follows: r = 0.831, y = 0.98x + 40.6 against LP-E2-N, r = 0.991, y = 1.08x + 12.4 against Architect, r = 0.995, y = 0.80x - 3.7 against Eclusys. In conclusion, the NEW LP-E2-N reagent displayed a relatively favorable kit performance except for in the elevation of assay results with hemoglobin, as well as a low cross-reactivity with E2 analogues and/or metabolites.


Assuntos
Anticorpos Monoclonais/imunologia , Bioensaio , Ensaio de Imunoadsorção Enzimática , Estradiol/análise , Animais , Bioensaio/métodos , Reações Cruzadas , Ensaio de Imunoadsorção Enzimática/métodos , Estradiol/imunologia , Humanos , Camundongos , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA