Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Pain Res ; 14: 311-324, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33568938

RESUMO

PURPOSE: Contemporary theories of pain suggest that how the body is perceived is central to the emergence of pain. The Fremantle Back Awareness Questionnaire (FreBAQ) was developed to assess body-perception specific to the back in people with chronic low back pain. However, there is no comprehensive measure to quantify self-perception of the painful area in Japanese people with neck pain. This study aimed to develop a Japanese version of a self-perception questionnaire specific to the neck and evaluate the validity and reliability of the scale using Rasch analysis. MATERIALS AND METHODS: The Fremantle Neck Awareness Questionnaire (FreNAQ-J) was developed by modifying the FreBAQ-J. One hundred people with chronic neck pain and fifty-six matched healthy controls completed the questionnaire. Rasch analysis was used to evaluate targeting, category order, unidimensionality, person fit, internal consistency, differential item functioning, and differential test functioning in the neck pain population. Validity was investigated by examining the relationship between the FreNAQ-J and clinical status. RESULTS: People with chronic neck pain endorsed FreNAQ-J items with greater frequency than healthy controls. FreNAQ-J did not reject the null hypothesis of fitting the Rasch model, had acceptable internal consistency and good test-retest reliability. Summed FreNAQ-J scores were significantly correlated with pain intensity, disability, pain-related catastrophizing and fear of movement. CONCLUSION: The individual items of the FreNAQ-J can be validly summed to provide a score of self-perception. The FreNAQ-J is the first scale developed for comprehensively evaluating disturbed body perception in Japanese patients with chronic neck pain.

2.
Nanomaterials (Basel) ; 9(7)2019 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-31331000

RESUMO

We fabricated tin phosphide-carbon (Sn4P3/C) composite film by aerosol deposition (AD) and investigated its electrochemical performance for a lithium-ion battery anode. Sn4P3/C composite powders prepared by a ball milling was used as raw material and deposited onto a stainless steel substrate to form the composite film via impact consolidation. The Sn4P3/C composite film fabricated by AD showed much better electrochemical performance than the Sn4P3 film without complexing carbon. Although both films showed initial discharge (Li+ extraction) capacities of approximately 1000 mAh g-1, Sn4P3/C films retained higher reversible capacity above 700 mAh g-1 after 100 cycles of charge and discharge processes while the capacity of Sn4P3 film rapidly degraded with cycling. In addition, by controlling the potential window in galvanostatic testing, Sn4P3/C composite film retained the reversible capacity of 380 mAh g-1 even after 400 cycles. The complexed carbon works not only as a buffer to suppress the collapse of electrodes by large volume change of Sn4P3 in charge and discharge reactions but also as an electronic conduction path among the atomized active material particles in the film.

3.
Geriatr Gerontol Int ; 18(8): 1267-1271, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29947464

RESUMO

AIM: We examined factors related to conditions of life function and falls, including eye movements and gait variability, in community-dwelling older adults in Japan. METHODS: Participants were 82 older adults (21 men, 61 women, mean age 76.1 years). We measured eye movements and gait variability during walking, and cognitive, attentional and life function. We compared two groups according to their fall history, and used a multiple logistic regression analysis to determine its relevance. RESULTS: Fixation time, which was estimated from eye movements during obstacle crossing, and gait variability (vertical) were significantly associated with falls. There was also a significant correlation between fixation time and gait variability during obstacle crossing. In other words, the higher the gait variability in older adults, the higher the risk of falls, which was due to reduced attention estimated from eye movements during obstacle crossing that required obstacle avoidance. CONCLUSIONS: These results show that poor attention during gait is a critical risk factor for falls in community-dwelling older adults. For fall prevention, it is necessary to promote exercises for attention, and to maintain an older adult-friendly pedestrian environment. Geriatr Gerontol Int 2018; 18: 1267-1271.


Assuntos
Acidentes por Quedas/prevenção & controle , Atenção/fisiologia , Marcha/fisiologia , Avaliação Geriátrica/métodos , Equilíbrio Postural/fisiologia , Acidentes por Quedas/estatística & dados numéricos , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Movimentos Oculares/fisiologia , Feminino , Humanos , Incidência , Vida Independente , Japão , Modelos Logísticos , Masculino , Análise Multivariada , Estudos Prospectivos , Medição de Risco , Distribuição por Sexo
4.
Pain Pract ; 18(2): 170-179, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28422409

RESUMO

BACKGROUND: There is a growing interest in the role of disturbed body perception in people with persistent pain problems such as chronic low back pain (CLBP). A questionnaire, the Fremantle Back Awareness Questionnaire (FreBAQ), was recently developed as a simple and quick way of assessing disturbed perceptual awareness of the back in people with CLBP and appears to have acceptable psychometric properties. The aim of the present study was to develop a Japanese version of the FreBAQ (FreBAQ-J) and evaluate its psychometric properties in a sample of Japanese people with low back pain (LBP). METHODS: Translation of the FreBAQ into Japanese was conducted using a forward-backward method. One hundred participants with LBP completed the resultant FreBAQ-J. A subset of the participants completed the FreBAQ-J again 2 weeks later. Validity was investigated by examining the relationship between the FreBAQ-J and clinical valuables. Rasch analysis was used to assess targeting, category ordering, unidimensionality, person fit, internal consistency, and differential item functioning. RESULTS: The FreBAQ-J was significantly correlated with pain in motion, disability, pain-related catastrophizing, fear of movement, and anxiety symptomatology. The FreBAQ-J had acceptable internal consistency, a minor departure from unidimensionality, and good test-retest reliability, and was functional on the category rating scale. CONCLUSIONS: The FreBAQ-J has acceptable psychometric properties and is suitable for use in people with LBP. Participants with high levels of disturbed body perception are well targeted by the scale. The functioning of one item (item 8) was poor. Further study is warranted to confirm if this item should be excluded.


Assuntos
Dor Lombar/psicologia , Psicometria/métodos , Traduções , Adulto , Idoso , Catastrofização/diagnóstico , Catastrofização/psicologia , Feminino , Humanos , Idioma , Masculino , Pessoa de Meia-Idade , Medição da Dor/métodos , Reprodutibilidade dos Testes , Inquéritos e Questionários
5.
PLoS One ; 12(6): e0179225, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28650969

RESUMO

BACKGROUND: Recent systematic reviews have demonstrated that pain associated with knee osteoarthritis (OA) is a complex phenomenon that involves various contributors. People with knee OA exhibit symptoms of impaired body-perception, including reduced tactile acuity, impairments in limb laterality recognition, and degraded proprioceptive acuity. The Fremantle Back Awareness Questionnaire (FreBAQ) was developed to assess body-perception specific to the back in people with chronic low back pain. The aim of this study was to develop and assess the psychometric properties of a knee-specific version of the FreBAQ-J (FreKAQ-J), determine whether people with knee pain experience perceptual impairments and investigate the relationship between disturbed self-perception and clinical status. METHODS: Sixty-five people with knee OA completed the FreKAQ-J. A subset of the participants completed the FreKAQ-J again two-weeks later. Rasch analysis was used to assess item order, targeting, category ordering, unidimensionality, person fit, internal consistency, and differential item functioning. Validity was investigated by examining the relationship between the FreKAQ-J and clinical valuables. RESULTS: The FreKAQ-J had acceptable internal consistency, unidimensionality, good test-retest reliability, and was functional on the category rating scale. The FreKAQ-J was significantly correlated with pain in motion, disability, pain-related catastrophizing, fear of movement, and anxiety symptomatology. CONCLUSIONS: We developed FreKAQ-J by modifying the FreBAQ-J. The FreKAQ-J fits the Rasch measurement model well and is suitable for use in people with knee OA. Altered body perception may be worth evaluating when managing people with knee OA.


Assuntos
Articulação do Joelho/fisiopatologia , Osteoartrite do Joelho/psicologia , Propriocepção/fisiologia , Autoimagem , Idoso , Catastrofização , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Medição da Dor , Psicometria , Reprodutibilidade dos Testes , Inquéritos e Questionários
6.
J Orthop Sci ; 22(2): 351-356, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28087217

RESUMO

BACKGROUND: The Pain Catastrophizing Scale (PCS) is a commonly used as measure of pain catastrophizing. The scale comprises 13 items related to magnification, rumination, and helplessness. To facilitate quick screening and to reduce participant's burden, the four-item and six-item short forms of the English version of the PCS were developed. The purpose of the present study was to evaluate the psychometric properties of a Japanese version of the short forms of PCS using a contemporary approach called Rasch analysis. METHODS: A total of 216 patients with musculoskeletal disorders were recruited in this study. Participants completed study measures, which included the pain intensity, the Pain Catastrophizing Scale (PCS), and the Tampa Scale of Kinesiophobia (TSK). Furthermore, the four-item (items 3, 6, 8, and 11) and six-item (items 4, 5, 6, 10, 11, and 13) short forms of the Japanese version of PCS were measured. We used Rasch analysis to analyze the psychometric properties of the original, four-item, and six-item short forms of PCS. RESULTS: Rasch analysis showed that both short forms of PCS had acceptable internal consistency, unidimensionality, and no notable DIF and were functional on the category rating scale. However, four-item short form of PCS had two misfit items. CONCLUSIONS: Six-item short form of PCS has acceptable psychometric properties and is suitable for use in participants with musculoskeletal pain. Thus, six-item can be used as brief instruments to evaluate pain catastrophizing.


Assuntos
Catastrofização , Dor Musculoesquelética/diagnóstico , Dor Musculoesquelética/psicologia , Medição da Dor , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Psicometria , Medição de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...