Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Cardiol ; 386: 17-23, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37201615

RESUMO

BACKGROUND: Echocardiography-based transvalvular mean pressure gradient (ECHO-mPG) used to assess the forward valve function and structural valve deterioration could overestimate the true pressure gradient. This study evaluated the discrepancy between invasive and ECHO-mPG after transcatheter aortic valve implantation (TAVI) with respective valve type and size, its impact on a device success criterion, and predictors of a pressure discrepancy. METHODS: We analyzed 645 patients registered in a multicenter TAVI registry (balloon-expandable valve [BEV]: 500; self-expandable valve [SEV]: 145). The invasive transvalvular mPG was measured after valve implantation using two Pigtail catheters (CATH-mPG), while the ECHO-mPG was measured within 48 h after TAVI. Pressure recovery (PR) was calculated using the following formula: ECHO-mPG × effective orifice area (EOA)/ascending aortic area (AoA) × (1 - EOA/AoA). RESULTS: ECHO-mPG was weakly correlated with (r = 0.29, p < 0.0001), and consistently overestimated CATH-mPG in both BEV and SEV, and respective valve sizes. The magnitude of the discrepancy was larger for BEV than SEV (p < 0.001) and smaller valves (p < 0.001). After the correction of PR using the above formula, the pressure discrepancy remained for BEV (p < 0.001) but not SEV (p = 0.10). The proportion of patients with an ECHO-mPG > 20 mmHg decreased from 7.0% to 1.6% after correction (p < 0.0001). Among the baseline and procedural variables, post-procedural ejection fraction, BEV versus SEV, and smaller valves were associated with a larger discrepancy in mPG. CONCLUSIONS: ECHO-mPG could be overestimated after TAVI, especially in patients with a smaller BEV. A higher ejection fraction, BEV, and smaller valves were predictors of a pressure discrepancy between CATH- and ECHO-mPG.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Sistema de Registros , Resultado do Tratamento , Desenho de Prótese
2.
J Alzheimers Dis ; 58(2): 349-354, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28453490

RESUMO

To elucidate an involvement of amyloid dysmetabolism in the pathophysiology of depression, we investigated associations of plasma amyloid-ß (Aß) levels with Alzheimer's disease-related changes in neuroimaging and cognitive dysfunction in patients with late-life depression. Higher plasma Aß40, but not Aß42 nor Aß40/Aß42 ratio, was associated with higher degree of parahippocampal atrophy and lower verbal fluency performance. Indeed, high plasma Aß40 predicted poor cognitive prognosis of depressed patients with mild cognitive impairment. As an anti-depressive treatment, electroconvulsive therapy (ECT) resulted in a marginally significant reduction of plasma Aß40 compared to pharmacotherapy alone, suggesting protective effects of ECT against amyloid dysmetabolism.


Assuntos
Peptídeos beta-Amiloides/sangue , Transtorno Depressivo/sangue , Transtorno Depressivo/terapia , Fragmentos de Peptídeos/sangue , Idoso , Idoso de 80 Anos ou mais , Antidepressivos/uso terapêutico , Disfunção Cognitiva/etiologia , Transtorno Depressivo/diagnóstico por imagem , Eletroconvulsoterapia/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Escalas de Graduação Psiquiátrica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...