Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Drug Test Anal ; 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605570

RESUMO

Doping analyses are essential for sporting events because some athletes might use prohibited substances to win games. To obtain reliable results from doping analyses, it is important to use both reliable standard solutions and validated analytical methods at accredited laboratories. Among the focused compounds related to prohibited substances listed by the World Anti-Doping Agency, we developed a certified reference material (CRM) for 3ß,4α-dihydroxy-5α-androstan-17-one (DHAS), a metabolite of formestane that is used to conceal prohibited anabolic steroids, in methanol solution (NMIJ CRM 6212-a). To develop a CRM traceable to the International System of Units (SI), we newly applied different analytical methods with an SI-traceable internal standard for quantitative NMR (qNMR) instead of mass balance approach because this CRM solution was required to develop rapidly using a limited amount of high-purity DHAS. One method was gravimetric blending using the purity of DHAS powder evaluated by both qNMR and a combination of qNMR and high-performance liquid chromatography (HPLC), and the other was direct quantification of the DHAS mass fraction in the candidate solution CRM by both qNMR and qNMR/HPLC. Because the values obtained by gravimetric blending and direct quantification of the mass fraction were comparable, the arithmetic mean was applied to obtain the certified value. Considering homogeneity and stability according to ISO Guide 35: 2017, the certified values with expanded uncertainties (coverage factor k = 2, approximate 95% confidence interval) were (135.2 ± 9.5) µg/g for the mass fraction and (107.0 ± 7.5) µg/ml for the mass concentration.

2.
J Biol Chem ; 299(10): 105254, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37716701

RESUMO

Listeriosis, caused by infection with Listeria monocytogenes, is a severe disease with a high mortality rate. The L. monocytogenes virulence factor, internalin family protein InlA, which binds to the host receptor E-cadherin, is necessary to invade host cells. Here, we isolated two single-domain antibodies (VHHs) that bind to InlA with picomolar affinities from an alpaca immune library using the phage display method. These InlA-specific VHHs inhibited the binding of InlA to the extracellular domains of E-cadherin in vitro as shown by biophysical interaction analysis. Furthermore, we determined that the VHHs inhibited the invasion of L. monocytogenes into host cells in culture. High-resolution X-ray structure analyses of the complexes of VHHs with InlA revealed that the VHHs bind to the same binding site as E-cadherin against InlA. We conclude that these VHHs have the potential for use as drugs to treat listeriosis.

3.
Anal Bioanal Chem ; 415(12): 2261-2269, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36939882

RESUMO

Trichloroacetic acid is known as one of the harmful disinfection byproducts with chlorine of tap water and is regulated according to legally binding standards in Japanese Drinking Water Quality Standards. We developed a high-purity trichloroacetic acid reference material, NMIJ CRM 4074-a, with certified purity as a traceability source of standard solution supplied under the Japan Calibration Service System (JCSS). As trichloroacetic acid is hygroscopic, water could be the main impurity. Although all impurities in the sample can be possibly detected by the freezing point depression method (FPD), it was unclear for trichloroacetic acid whether water was detected by FPD owing to evaporation of water from the sample during fusion. Therefore, we confirmed that water in trichloroacetic acid was detected as an impurity by FPD. The procedure was validated from an increment of purity by FPD due to reduction of water content and an agreement of purity by FPD with those by neutralization titrimetry (NT) and mass balance approach (MBA), both methods were based on different measurement principles from FPD. The certified value was determined to be (0.999 ± 0.003) kg kg-1 from the purity assay by FPD and NT, and uncertainties due to the homogeneity and stability of the CRM were included in the expanded uncertainty. The reliability of the certified value was verified by the agreement of purities by FPD, NT, and MBA.

4.
Chem Pharm Bull (Tokyo) ; 69(1): 18-25, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33390516

RESUMO

Mogroside V is one of the characteristic and effective components of luohanguo extract, a food additive used as a sweetener in Japan as per Japan's Standards and Specifications for Food Additives (JSFA; 9th ed.). JSFA stipulates that the quantitative determination for mogroside V content in luohanguo extract applies HPLC using analytical standard mogroside V. However, no mogroside V reagents with proven purities are commercially available. Therefore the current JSFA determination method is not particularly suited for daily quality control operations involving luohanguo extract. In this study, we applied an alternative quantitative method using a single reference with relative molar sensitivity (RMS). It was possible to calculate the accurate RMS by an offline combination of 1H-quantitative NMR spectroscopy (1H-qNMR) and an HPLC/variable-wavelength detector (VWD). Using the RMS of mogroside V to a commercial certified reference material grade caffeine, the mogroside V contents in luohanguo extracts could be determined using HPLC/VWD without analytical standard mogroside V. There was no significant difference between the mogroside V contents in luohanguo extracts determined using the method employing single-reference caffeine with the RMS and using the JSFA method. The absolute calibration curve for the latter was prepared using an analytical standard mogroside V whose purity was determined by 1H-qNMR. These results demonstrate that our proposed method using a single reference with RMS is suitable for quantitative determination of mogroside V in luohanguo extract and can be used as an alternative method to the current assay method in JSFA.


Assuntos
Cafeína/análise , Cucurbitaceae/química , Aditivos Alimentares/análise , Extratos Vegetais/análise , Triterpenos/análise , Cafeína/normas , Cromatografia Líquida de Alta Pressão/normas , Aditivos Alimentares/normas , Japão , Espectroscopia de Ressonância Magnética/normas , Extratos Vegetais/normas , Controle de Qualidade , Triterpenos/normas
5.
Chem Pharm Bull (Tokyo) ; 68(9): 868-878, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32565492

RESUMO

NMR spectroscopy has recently been utilized to determine the absolute amounts of organic molecules with metrological traceability since signal intensity is directly proportional to the number of each nucleus in a molecule. The NMR methodology that uses hydrogen nucleus (1H) to quantify chemicals is called quantitative 1H-NMR (1H qNMR). The quantitative method using 1H qNMR for determining the purity or content of chemicals has been adopted into some compendial guidelines and official standards. However, there are still few reports in the literature regarding validation of 1H qNMR methodology. Here, we coordinated an international collaborative study to validate a 1H qNMR based on the use of an internal calibration methodology. Thirteen laboratories participated in this study, and the purities of three samples were individually measured using 1H qNMR method. The three samples were all certified via conventional primary methods of measurement, such as butyl p-hydroxybenzoate Japanese Pharmacopeia (JP) reference standard certified by mass balance; benzoic acid certified reference material (CRM) certified by coulometric titration; fludioxonil CRM certified by a combination of freezing point depression method and 1H qNMR. For each sample, 1H qNMR experiments were optimized before quantitative analysis. The results showed that the measured values of each sample were equivalent to the corresponding reference labeled value. Furthermore, assessment of these 1H qNMR data using the normalized error, En-value, concluded that statistically 1H qNMR has the competence to obtain the same quantification performance and accuracy as the conventional primary methods of measurement.


Assuntos
Espectroscopia de Ressonância Magnética/normas , Ácido Benzoico/química , Calibragem , Dioxóis/química , Hidroxibenzoatos/química , Cooperação Internacional , Espectroscopia de Ressonância Magnética/métodos , Pirróis/química , Padrões de Referência , Reprodutibilidade dos Testes
6.
Food Chem ; 298: 125011, 2019 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-31261011

RESUMO

A scallop midgut gland certified reference material, NMIJ CRM 7520-a, was developed for validation and quality assurance during the inspection of shellfish for diarrhetic shellfish toxins. The candidate material was prepared by using naturally-toxic and nontoxic boiled midgut glands spiked with okadaic acid (OA). The homogeneity and stability of the material were found to be appropriate. For the characterization of OA and dinophysistoxin-1 (DTX1), nine participants were involved in a co-laboratory study based on the Japanese Official Testing Method, where the compounds were assayed by liquid chromatography-tandem mass spectrometry following alkaline hydrolysis. The analytical values were obtained by the standard addition method with a standard spiking solution calibrated using the standard-solution certified reference materials OA and DTX1. The certified concentrations with expanded uncertainties (coverage factor k = 2, approximate 95% confidence interval) were determined to be (0.205 ±â€¯0.061) mg/kg for OA and (0.45 ±â€¯0.11) mg/kg for DTX1.


Assuntos
Diarreia/complicações , Toxinas Marinhas/análise , Pectinidae/química , Piranos/análise , Frutos do Mar/análise , Animais , Calibragem , Cromatografia Líquida , Humanos , Intestinos/química , Toxinas Marinhas/normas , Toxinas Marinhas/toxicidade , Ácido Okadáico/análise , Piranos/normas , Piranos/toxicidade , Padrões de Referência , Intoxicação por Frutos do Mar/complicações , Espectrometria de Massas em Tandem
7.
Anal Bioanal Chem ; 411(23): 6091-6100, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31289897

RESUMO

Two 600-bp DNA solutions (DNA600-G and DNA600-T) were developed as certified reference material, NMIJ CRM 6205-a, for the validation of DNA quantification methods. Both DNA600-G and DNA600-T are ideal as "spike-in control" because these materials have artificial nucleic acid sequences. The certified values were determined as the mass concentration of total DNA (whole DNA materials in sample solution regardless of sequence) at 25 °C by formic acid hydrolysis/liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) and inductively coupled plasma-mass spectrometry (ICP-MS) based on the amount of phosphorus. DNAs were synthesized, and plasmids including the synthesized DNAs were cloned into Escherichia coli DH5α. The amplified plasmids were digested with a restriction enzyme and highly purified. Then, the purified DNAs were diluted with water to approximately 1 ng/µL. By using the CRM-validated methods in fields where DNA quantification is required, the reliability of DNA quantification could be improved. Graphical abstract.


Assuntos
DNA/análise , Espectrometria de Massas/métodos , Sequência de Bases , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , DNA/genética , Formiatos/química , Hidrólise , Espectrometria de Massas/normas , Plasmídeos/análise , Plasmídeos/genética , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase/normas , Padrões de Referência
8.
J Nat Med ; 73(3): 566-576, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31016636

RESUMO

Perillaldehyde (PRL) is one of the essential oil components derived from perilla plants (Perilla frutescens Britton) and is a characteristic compound of the traditional medicine "perilla herb ()" listed in the The Japanese Pharmacopoeia, 17th edition (JP17). HPLC using an analytical standard of PRL has been used to quantitatively determine the PRL content in perilla herb. However, PRL reagents have been reported to decompose easily. In this study, we utilized an alternative quantitative method using on a single reference with relative molar sensitivity (RMS) based on the results of experiments performed in two laboratories. It was possible to calculate the exact RMS using an offline combination of 1H-quantitative NMR spectroscopy (1H-qNMR) and an HPLC/photodiode array (PDA) detector (or an HPLC/variable-wavelength detector [VWD]). Using the RMS of PRL to the single-reference compound diphenyl sulfone (DFS), which is an inexpensive and stable compound, the PRL content in the perilla herb could be determined using HPLC/PDA or HPLC/VWD without the need for the analytical standard of PRL. There was no significant difference between the PRL contents of perilla herb determined using the method employing the single-reference DFS with RMS and using the JP17 assay, the calibration curve of which was generated using the analytical standard of PRL with adjusted purity measured by 1H-qNMR. These results demonstrate that our proposed method using a single reference with RMS is suitable for quantitative assays of perilla herb and can be an alternative method for the current assay method defined in the JP17.


Assuntos
Monoterpenos/análise , Óleos Voláteis/análise , Perilla frutescens/química , Sulfonas/química , Cromatografia Líquida de Alta Pressão/métodos , Espectroscopia de Ressonância Magnética
9.
Artigo em Inglês | MEDLINE | ID: mdl-30668225

RESUMO

We have been developing a high-performance liquid chromatography/photodiode array (HPLC/PDA) employing relative molar sensitivities (RMSs) and adopted it to the accurate quantification of carnosol (CL) and carnosic acid (CA) which are the antioxidants in rosemary extract. The method requires no references of CL or CA and instead uses RMSs with respect to diphenylamine (DPA) whose certified reference material is available from a reagent manufacturer. The molar and response ratios of the analytes to the reference in an artificial mixture of them were determined using 1H-quantitative nuclear magnetic resonance spectroscopy (1H-qNMR) and HPLC/PDA at a wavelength of 284 nm under isocratic condition, respectively, and then RMSs were calculated to be 0.111 for CL/DPA and 0.0809 for CA/DPA as averaged values in three HPLC-PDA instruments. The RMS values varied by up to 1.1% as relative standard deviation. To evaluate the performance of HPLC/PDA with the RMSs, the CL and CA contents in rosemary extracts were determined using DPA as a reference. The CL and CA contents were compared with those determined using calibration curves of CL and CA obtained by HPLC measurement of standard solutions prepared from their reagents whose absolute purities were determined using 1H-qNMR. The differences between the two methods for CL and CA were ≤3% as relative error. This chromatographic method with RMSs allows a simple and reliable quantification when reference of the analyte is unavailable.


Assuntos
Abietanos/análise , Antioxidantes/análise , Difenilamina/química , Rosmarinus/química , Cromatografia Líquida de Alta Pressão
10.
Shokuhin Eiseigaku Zasshi ; 59(1): 1-10, 2018.
Artigo em Japonês | MEDLINE | ID: mdl-29743461

RESUMO

We designed an off-line combination of HPLC/photodiode array detector (PDA) and 1H-quantitative NMR (1H-qNMR) to estimate the relative molar sensitivity (RMS) of an analyte to a reference standard. The RMS is calculated as follows: a mixture of the analyte and the reference is analyzed using 1H-qNMR and HPLC/PDA. The response ratio of the analyte and the reference obtained by HPLC/PDA is then corrected using the molar ratio obtained by 1H-qNMR. We selected methylparaben (MPB), which is a certified reference material, as the reference standard and hesperidin (Hes) and monoglucosylhesperidin (MGHes) as analytes, and the RMSs of Hes283 nm/MPB255 nm and MGHes283 nm/MPB255 nm were determined as 1.25 and 1.32, respectively. We determined the contents of Hes and MGHes in processed foods by the conventional absolute calibration method and by the internal standard method employing the RMS values with respect to MPB. The differences between the values obtained with the two methods were less than 2.0% for Hes and 3.5% for MGHes.


Assuntos
Análise de Alimentos/métodos , Manipulação de Alimentos , Hesperidina/análogos & derivados , Hesperidina/análise , Espectroscopia de Ressonância Magnética/métodos , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Parabenos/análise
11.
Food Chem ; 252: 366-372, 2018 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-29478555

RESUMO

An interlaboratory comparison (ILC) was organized as a measure of the analytical competency in the liquid chromatography-tandem mass spectrometry quantification of okadaic acid (OA) and dinophysistoxin-1 (DTX1) in scallop midgut gland samples. The test sample was prepared using boiled midgut glands of naturally contaminated scallops with DTX1 and its esters by spiking with OA, and homogeneity and stability of this test sample was assessed to be appropriate. Twenty laboratories participated in the ILC based on the Japanese official testing method; they submitted two sets of analytical concentrations of target analytes along with the details of their analytical protocols. For assessing these data, assigned values were established from another ILC where ten participants quantified the target analytes by the standard addition method. The mean analytical results of the former ILC showed good agreement with the assigned values, and the corresponding relative reproducibility standard deviations met the criterion of CODEX STAN 292. Meanwhile, the results of more than half of the participants were out of the uncertainty range of the assigned values; these participants were encouraged to investigate their protocols to improve their analytical capability.


Assuntos
Toxinas Marinhas/análise , Ácido Okadáico/análise , Pectinidae/química , Piranos/análise , Frutos do Mar/análise , Animais , Cromatografia Líquida , Intestinos/química , Toxinas Marinhas/toxicidade , Ácido Okadáico/toxicidade , Piranos/toxicidade , Reprodutibilidade dos Testes , Intoxicação por Frutos do Mar/etiologia , Espectrometria de Massas em Tandem
12.
Artigo em Inglês | MEDLINE | ID: mdl-29447580

RESUMO

To accurately determine carminic acid (CA) and its derivative 4-aminocarminic acid (4-ACA), a novel, high-performance liquid chromatography with photodiode array detector (HPLC/PDA) method using relative molar sensitivity (RMS) was developed. The method requires no analytical standards of CA and 4-ACA; instead it uses the RMS values with respect to caffeine (CAF), which is used as an internal standard. An off-line combination of 1H-quantitative nuclear magnetic resonance spectroscopy (1H-qNMR) and HPLC/PDA was able to precisely determine the RMSs of CA274nm/CAF274nm and 4-ACA274nm/CAF274nm. To confirm the performance of the HPLC/PDA method using RMSs, the CA and 4-ACA contents in test samples were tested using four different HPLC-PDA instruments and one HPLC-UV. The relative standard deviations of the results obtained from five chromatographs and two columns were less than 2.7% for CA274nm/CAF274nm and 1.1% for 4-ACA274nm/CAF274nm. The 1H-qNMR method was directly employed to analyse the CA and 4-ACA contents in test samples. The differences between the quantitative values obtained from both methods were less than 5% for CA and 3% for 4-ACA. These results demonstrate that the HPLC/PDA method using RMSs to CAF is a simple and reliable quantification method that does not require CA and 4-ACA certified reference materials.


Assuntos
Cafeína/química , Carmim/análogos & derivados , Carmim/análise , Contaminação de Alimentos/análise , Cromatografia Líquida de Alta Pressão , Estrutura Molecular
13.
Anal Sci ; 33(11): 1241-1245, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29129862

RESUMO

To prepare metrologically traceable amino acid mixed standard solutions, it is necessary to determine the stability of each amino acid present in the mixed solutions. In the present study, we prepared amino acid mixed solutions using certified reference standards of 17 proteinogenic amino acids, and examined the stability of each of these amino acids in 0.1 N HCl. We found that the concentration of glutamic acid decreased significantly during storage. LC/MS analysis indicated that the instability of glutamic acid was due to the partial degradation of glutamic acid to pyroglutamic acid in 0.1 N HCl. Using accelerated degradation tests, we investigated several solvent compositions to improve the stability of glutamic acid in amino acid mixed solution, and determined that the change of the pH by diluting the mixed solution improved the stability of glutamic acid.


Assuntos
Armazenamento de Medicamentos/normas , Ácido Glutâmico/análise , Ácido Glutâmico/química , Proteínas/química , Estabilidade de Medicamentos , Ácido Clorídrico/química , Concentração de Íons de Hidrogênio , Padrões de Referência , Soluções , Solventes/química , Temperatura , Fatores de Tempo
14.
Anal Chem ; 89(13): 6963-6968, 2017 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-28581717

RESUMO

We have applied a combination of 1H quantitative NMR spectroscopy (1H-qNMR) and chromatography (GC or LC) to establish reliable analytical methods (qNMR/GC and qNMR/LC) for organic compounds. In this method, a reference standard is used as an internal standard for both 1H-qNMR and chromatography to estimate relative molar sensitivity (RMS) for analytes. The RMS values are calculated from the molar ratios between analytes and the reference standard obtained by 1H-qNMR; and the response ratio between them obtained by chromatography. Concentrations of analytes in the organic solution can be simultaneously determined from the RMS and amount of the reference standard added in the sample solution. This analytical method is an innovative one because only one reference standard with International System of Units (SI)-traceable property value, purity, or concentration, is necessary to determine accurate concentrations of multiple organic components in organic solutions, without the respective certified reference standards for various analytes. To verify this method, a certified reference material, NIST SRM 1647f, was used. Among the 16 polycyclic aromatic hydrocarbons (PAHs) included in NIST SRM 1647f, naphthalene and benzo[a]pyrene were selected as analytes for this method, using 1,4-bis(trimethylsilyl)benzene-d4 as the reference standard. Each quantitative value obtained by qNMR/GC and qNMR/LC agreed with each certified value within its expanded uncertainty.

15.
Anal Sci ; 33(3): 369-373, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28302980

RESUMO

We describe a procedure to determine concentrations of amino acid standard solutions by quantitative NMR spectroscopy using an internal standard. The measurement samples were prepared by solvent exchange to remove any intense solvent signal in the 1H NMR spectra. The method was demonstrated on valine aqueous solutions of different concentrations. The accuracy of the measured concentrations that fell well within the range of the expanded uncertainty is also discussed. All of the results are in good agreement with the preparation values. We believe that this approach should be useful to determine the concentrations of standard solutions whose solute components are difficult to weigh because of extremely small amount or hygroscopicity.


Assuntos
Aminoácidos/análise , Espectroscopia de Prótons por Ressonância Magnética/normas , Padrões de Referência , Soluções , Água/química
16.
Toxins (Basel) ; 8(10)2016 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-27754382

RESUMO

ERETIC2 (Electronic Reference To access In vivo Concentrations 2) based on PULCON (Pulse Length-based Concentration determination) methodology is a quantitative NMR (qNMR) using an external standard. The performance of the PULCON method was assessed using maleic acid (MA). Quantification of the diarrhetic shellfish toxin and okadaic acid by PULCON was successfully consistent with that obtained by a conventional internal standard method, demonstrating that the PULCON method is useful for the quantification of invaluable marine toxins without any contaminations by an internal standard.


Assuntos
Toxinas Marinhas/análise , Ácido Okadáico/análise , Espectroscopia de Ressonância Magnética/métodos , Maleatos/análise
17.
J Chromatogr A ; 1468: 109-115, 2016 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-27665496

RESUMO

Liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) with formic acid hydrolysis was established for the accurate quantification of λDNA. The over-decomposition of nucleobases in formic acid hydrolysis was restricted by optimizing the reaction temperature and the reaction time, and accurately corrected by using deoxynucleotides (dNMPs) and isotope-labeled dNMPs as the calibrator and the internal standard, respectively. The present method could quantify λDNA with an expanded uncertainty of 4.6% using 10fmol of λDNA. The analytical results obtained with the present method were validated by comparing with the results of phosphate-base quantification by inductively coupled plasma-mass spectrometry (ICP-MS). The results showed good agreement with each other. We conclude that the formic acid hydrolysis/LC-IDMS method can quantify λDNA accurately and is promising as the primary method for the certification of DNA as reference material.


Assuntos
Técnicas de Química Analítica/métodos , Cromatografia Líquida , DNA/análise , Formiatos/química , Espectrometria de Massas , Bacteriófago lambda/genética , Calibragem , Técnicas de Química Analítica/normas , Hidrólise , Marcação por Isótopo
18.
Biomed Chromatogr ; 30(2): 280-4, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26037490

RESUMO

A novel method of amino acid analysis using derivatization of multiple functional groups (amino, carboxyl, and phenolic hydroxyl groups) was applied to measure glycated amino acids in order to quantify glycated peptides and evaluate the degree of glycation of peptide. Amino and carboxyl groups of amino acids were derivatized with 1-bromobutane so that the hydrophobicities and basicities of the amino acids, including glycated amino acids, were improved. These derivatized amino acids could be detected with high sensitivity using LC-MS/MS. In this study, 1-deoxyfructosyl-VHLTPE and VHLTPE, which are N-terminal peptides of the ß-chains of hemoglobin, were selected as target compounds. After reducing the peptide sample solution with sodium borohydride, the obtained peptides were hydrolyzed with hydrochloric acid. The released amino acids were then derivatized with 1-bromobutane and analyzed with LC-MS/MS. The derivatized amino acids, including glycated amino acids, could be separated using an octadecyl silylated silica column and good sharp peaks were detected. We show a confirmatory experiment that the proposed method can be applied to evaluate the degree of glycation of peptides, using mixtures of glycated and non-glycated peptide.


Assuntos
Aminoácidos/análise , Aminoácidos/química , Cromatografia Líquida/métodos , Hemoglobinas/análise , Hemoglobinas/química , Espectrometria de Massas em Tandem/métodos , Aminoácidos/metabolismo , Glicosilação , Hemoglobinas/metabolismo , Limite de Detecção
19.
Anal Sci ; 31(8): 805-14, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26256605

RESUMO

To ensure the reliability of amino acid analyses, the National Metrology Institute of Japan of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST) has developed high-purity certified reference materials (CRMs) for 17 proteinogenic amino acids. These CRMs are intended for use as primary reference materials to enable the traceable quantification of amino acids. The purity of the present CRMs was determined based on two traceable methods: nonaqueous acidimetric titration and nitrogen determination by the Kjeldahl method. Since neither method could distinguish compounds with similar structures, such as amino acid-related impurities, impurities were thoroughly quantified by combining several HPLC methods, and subtracted from the obtained purity of each method. The property value of each amino acid was calculated as a weighted mean of the corrected purities by the two methods. The uncertainty of the property value was obtained by combining measurement uncertainties of the two methods, a difference between the two methods, the uncertainty from the contribution of impurities, and the uncertainty derived from inhomogeneity. The uncertainty derived from instability was considered to be negligible based on stability monitoring of some CRMs. The certified value of each amino acid, property value with uncertainty, was given for both with or without enantiomeric separation.


Assuntos
Aminoácidos/análise , Cromatografia Líquida de Alta Pressão/normas , Proteínas/química , Aminoácidos/química , Padrões de Referência , Reprodutibilidade dos Testes , Estereoisomerismo , Incerteza
20.
J Chromatogr A ; 1406: 210-4, 2015 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-26141274

RESUMO

We have developed a highly sensitive method for the analysis of deoxynucleotide monophosphates (dNMPs), which involves the use of liquid chromatography/mass spectrometry (LC/MS) and a new metal-free column. The new column solves the problem that the phosphate group in dNMPs interacts with the metal portion of the device or column. After optimization of the analytical conditions, the limits of detection (LODs) of dNMPs were from 5.4ng/g to 6.3ng/g. Those values were 10 times lower than the LODs of previous methods. We applied the method to the determination of the base composition and the quantification of 20-mer oligonucleotide. Despite use of a very small sample amount of 14.5ng, we were able to determine the base composition, and the result was consistent with theoretical values. We were also able to quantify the mass fraction of oligonucleotide with 8.2% expanded uncertainty (k=2). By means of the developed method, we were able to analyze dNMPs with high sensitivity as well as determine the base composition and quantify the mass fraction of oligonucleotide despite use of a small amount of sample.


Assuntos
Técnicas de Química Analítica/métodos , Cromatografia Líquida , Espectrometria de Massas , Oligonucleotídeos/análise , Fosfatos de Dinucleosídeos/análise , Limite de Detecção , Metais/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...