Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 236
Filtrar
1.
Appl Radiat Isot ; 164: 109237, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32554127

RESUMO

The procedure followed by the Nuclear Metrology Laboratory (LMN) at the IPEN-CNEN/SP, in São Paulo, for the primary standardization of 166Ho is described. The activity of 166Ho was determined by the efficiency extrapolation technique applied to a 4πß(PC)-γ coincidence system using a gas flow proportional counter in 4π geometry coupled to a 76 × 76 mm NaI(Tl) crystal. The results for the γ-rays intensities at 80.57 and 1379.45 keV were 0.0651(11) and 0.00904(11), respectively.


Assuntos
Raios gama , Hólmio/normas , Radioisótopos/normas , Padrões de Referência , Espectrometria gama/normas
2.
Appl Radiat Isot ; 154: 108846, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31442792

RESUMO

In the present work, the determinations of k0 and Q0 for 74Se, 113In, 186W and 191Ir targets were performed. The irradiations were conducted near the core of the IEA-R1 4.5 MW swimming-pool nuclear research reactor of the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP - Nuclear and Energy Research Institute), in São Paulo, Brazil. The irradiation position was chosen where the neutron spectrum shape parameter α is very close to zero. For this reason, the correction to be applied for the determination of Q0 is very close to one, thus improving the accuracy of the results. For each experiment, two irradiations were carried out in sequence: the first one with bare samples and the second with a cadmium cover around the samples. All partial uncertainties were considered, applying the covariance matrix methodology. The final results were compared with the literature.

3.
Appl Radiat Isot ; 134: 312-315, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28927836

RESUMO

The procedure followed by the Nuclear Metrology Laboratory (LMN) at the IPEN for the standardization of activity of 64Cu is described. The measurement was carried out in a 4π (PC) ß-γ coincidence system. The activity per unit mass of the solution was determined by the extrapolation technique. The events were registered using a Time to Amplitude Converter (TAC) associated with a Multi-channel Analyzer. The gamma-ray emission probability per decay of the 1345.7keV transition of 64Cu determined with a calibrated REGe gamma-ray spectrometer was (0.472 ± 0.010) %, in agreement with the literature.

4.
Appl Radiat Isot ; 109: 386-388, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26688361

RESUMO

The procedure for the standardization of (59)Fe using a 4π(PC)ß-γ software coincidence system is described. The standardization was performed with an experimental setup consisting of a thin window gas-flow proportional counter (PC) in 4π geometry coupled to a NaI(Tl) scintillator and to a HPGe detector. The data acquisition was carried out by means of a Software Coincidence System (SCS). The beta efficiency was changed by using Collodion films and aluminum foils as external absorbers.

5.
Appl Radiat Isot ; 70(9): 2091-6, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22425419

RESUMO

A series of (123)I measurements have been carried out in a 4π(e(A),X)-γ coincidence system. The experimental extrapolation curve was determined and compared to Monte Carlo simulation, performed by code ESQUEMA. From the slope of the experimental curve, the total conversion coefficient for the 159 keV total gamma transition, α(159), was determined. All radioactive sources were also measured in an HPGe spectrometry system, in order to determine the gamma-ray emission probability per decay for several gamma transitions. All uncertainties involved and their correlations were analyzed applying the covariance matrix methodology and the measured parameters were compared with those from the literature.


Assuntos
Radioisótopos do Iodo/análise , Modelos Químicos , Modelos Estatísticos , Radiometria/métodos , Simulação por Computador , Interpretação Estatística de Dados , Raios gama , Meia-Vida , Método de Monte Carlo , Doses de Radiação
6.
Appl Radiat Isot ; 70(9): 1825-30, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22445396

RESUMO

An international Key Comparison of (177)Lu has recently been carried out. Twelve laboratories performed assays for radioactivity content on aliquots of a common master solution of (177)Lu, leading to eleven results submitted for entry into the Key Comparison Database of the Mutual Recognition Arrangement. A proposed Comparison Reference Value (CRV) was calculated to be 3.288(4)MBq/g using all eleven results. Degrees of equivalence and their uncertainties were calculated for each laboratory based on the CRV. Most of the values reported by the participating laboratories were within 0.6% of the CRV.


Assuntos
Lutécio/análise , Lutécio/química , Radioisótopos/análise , Radioisótopos/química , Radiometria/instrumentação , Radiometria/normas , Lutécio/normas , Doses de Radiação , Radioisótopos/normas , Padrões de Referência , Valores de Referência
7.
Appl Radiat Isot ; 69(7): 960-4, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21478022

RESUMO

The values of k(0) and Q(0) for (64)Zn(n,γ)(65)Zn and (68)Zn(n,γ)(69m)Zn reactions were determined experimentally. The irradiations were performed near the core of the IEA-R1 3.5MW nuclear research reactor of the Nuclear and Energy Research Institute - IPEN-CNEN/SP, in São Paulo, Brazil. The results for the neutron field parameters f and α were 49.7(19) and -1.1(31)×10(-3), respectively. The resulting values of k(0) and Q(0) for (64)Zn(n,γ)(65)Zn reaction were 5.63(8)×10(-3) and 1.69(6), respectively, and the corresponding values for (68)Zn(n,γ)(69m)Zn reaction were 4.00(6)×10(-4) and 2.34(4), respectively. These results were compared with the literature.

8.
J Insect Physiol ; 57(6): 784-90, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21414319

RESUMO

The resumption of spermatogenesis in post-diapause development was examined in the sweet potato hornworm (Agrius convolvuli) with in vivo bromodeoxyuridine (BrdU) incorporation experiments used to determine the starting point. Diapausing pupae were "overwintered" by chilling at 10 °C for over 4 months, after which they initiated post-diapause development by transferring the pupae to 25 °C with a 12-h light/12-h dark photoperiod. The testes of living, post-diapause pupae were injected with BrdU, which is incorporated into newly synthesized DNA strands. During the first 2 days after diapause termination, the nuclei of spermatogonia and spermatocytes failed to label with BrdU. However, on day 3 of post-diapause pupae (PDP3), labeling studies showed that cell proliferation was initiated by spermatogonia, but not by spermatocytes. In both hemolymph and testes, ecdysteroid concentrations rose gradually, reaching 0.3 µg/ml hemolymph at PDP3. These results led to the following three conclusions. The spermatogonial cell division is highly suppressed during diapause. After a long-term diapause, spermatogenesis resumes in the spermatogonia but not in the spermatocytes of diapause-terminated pupae. Cell division begins in advance of peak ecdysteroid concentrations. The latter result indicates that in post-diapause development, high concentrations of the hormone are not required to initiate spermatogonial proliferation.


Assuntos
Mariposas/crescimento & desenvolvimento , Espermatogênese , Espermatogônias/citologia , Animais , Divisão Celular , Proliferação de Células , Ecdisteroides/metabolismo , Masculino , Mariposas/citologia , Mariposas/metabolismo , Pupa/citologia , Pupa/crescimento & desenvolvimento , Pupa/metabolismo , Espermatogônias/metabolismo
9.
Radiat Prot Dosimetry ; 140(1): 96-100, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20159919

RESUMO

In this work, the uranium (U) content in sediment and soil samples collected near the Santos and São Vicente estuaries was determined using the fission track registration technique (SSNTD). The sediment and soil samples after oven-dried and pulverised were prepared in the solution form. About 10 microl of this solution was deposited on a plastic detector and irradiated at the IPEN-IEA-R1 (3.5 MW) nuclear reactor. After the irradiation and chemical etching of the plastic foils, the fission tracks were counted with a system consisting of an optical microscope together with a video camera and a PC. The U content in the analysed samples ranged from 3.12 +/- 0.55 to 18.3 +/- 1.2 ppm for sediments and from 3.21 +/- 0.63 to 11.5 +/- 1.1 ppm for soils or in terms of (238)U equivalent activity from 38.5 +/- 6.8 to 226 +/- 15 and 39.6 +/- 7.8 to 142 +/- 14 Bq kg(-1) for sediments and soils, respectively. These results were compared with other values reported in the literature for sediments and soils collected in environments similar to the ones studied in this work. Most of the values obtained in this work are higher than the world mean and are in reasonable agreement with results found by other authors for sediments and soils from regions considered as polluted or with a high level of radioactivity.


Assuntos
Sedimentos Geológicos/análise , Poluentes Radioativos do Solo/análise , Urânio/análise , Brasil , Humanos , Monitoramento de Radiação
10.
Appl Radiat Isot ; 68(7-8): 1566-70, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20060732

RESUMO

This work describes the measurements of the K X-ray and gamma-ray emission probabilities per decay of (198)Au performed at the Nuclear Metrology Laboratory (LMN) at the IPEN, São Paulo. The radioactive sample was obtained by means of (197)Au(n, gamma)(198)Au reaction irradiating an Au foil in a thermal neutron flux near the core of the IPEN 3.5 MW research reactor. The activity of samples was determined in a 4pibeta-gamma coincidence system, setting the gamma window at the 411.80 keV total energy absorption peak. The same samples were measured in two different spectrometers: a HPGe planar spectrometer with Be window, suitable for measurements in the low energy range and a coaxial REGe spectrometer. Both spectrometers were previously calibrated in a well defined geometry by means of standard sources calibrated in a 4pibeta-gamma coincidence system. MCNP4C Monte Carlo code was used for simulating the REGe spectrometer calibration curve, and a new version of code ESQUEMA was adopted for simulating the detection processes in the coincidence system, in order to predict the efficiency extrapolation curve.


Assuntos
Radioisótopos de Ouro , Raios gama , Probabilidade , Análise Espectral , Raios X
11.
Kyobu Geka ; 62(10): 916-9, 2009 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-19764501

RESUMO

A 65-year-old woman was admitted to our hospital with a diagnosis of cerebral infarction. She had incomplete paralysis of the right upper extremity. The echocardiogram showed a soft, mobile mass on the atrial side of the mitral posterior leaflet. Surgical treatment was performed 3 weeks after the episode of cerebral infarction. The mass originated from the P1 portion of the posterior leaflet. It was soft and fragile and was carefully resected along with the endocardium of the leaflet, from which it arose. The leaflet was reconstructed with direct 6-0 proline sutures. There was no mitral insufficiency. The histological diagnosis was a papillary fibroelastoma of the mitral valve. The postoperative course was uneventful, with no neurologic complications.


Assuntos
Fibroma/cirurgia , Neoplasias Cardíacas/cirurgia , Valva Mitral , Idoso , Feminino , Fibroma/patologia , Neoplasias Cardíacas/patologia , Humanos
12.
J Bone Joint Surg Br ; 90(5): 592-6, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18450624

RESUMO

We carried out a prospective study of 132 patients (159 knees) who underwent closed-wedge high tibial osteotomy for severe medial compartment osteoarthritis between 1988 and 1997. A total of 94 patients (118 knees) was available for review at a mean of 16.4 years (16 to 20). Seven patients (7.4%) (11 knees) required conversion to total knee replacement. Kaplan-Meier survival was 97.6% (95% confidence interval 95.0 to 100) at ten years and 90.4% (95% confidence interval 84.1 to 96.7) at 15 years. Excellent and good results as assessed by the Hospital for Special Surgery knee score were achieved in 87 knees (73.7%). A pre-operative body mass index > 27.5 kg/m(2) and range of movement < 100 degrees were risk factors predicting early failure. Although our long-term results were satisfactory, strict indications for osteotomy are required if long-term survival is required.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Osteotomia/métodos , Tíbia/cirurgia , Idoso , Artroplastia do Joelho/normas , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteotomia/normas , Medição da Dor , Amplitude de Movimento Articular , Reoperação , Fatores de Tempo
13.
Appl Radiat Isot ; 66(6-7): 733-6, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18342526

RESUMO

This work describes the procedure followed by the Laboratório de Metrologia Nuclear (LMN) for the standardization of (55)Fe by the tracing method. This technique was applied using two radionuclides, which decay by the electron capture process followed by a prompt gamma-ray, namely (51)Cr and (54)Mn, as tracers. The calibration was performed in a 4pibeta-gamma coincidence system. The efficiency was obtained by selecting a gamma-ray window set at the 320keV total absorption peak for (51)Cr and at 834keV for (54)Mn.

15.
Phys Rev Lett ; 96(11): 114801, 2006 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-16605830

RESUMO

We have demonstrated for the first time the production of highly polarized short-pulse positrons with a finite energy spread in accordance with a new scheme that consists of two-quantum processes, such as inverse Compton scattering and electron-positron pair creation. Using a circularly polarized laser beam of 532 nm scattered off a high-quality, 1.28 GeV electron beam, we have obtained polarized positrons with an intensity of 2 x 10(4) e+ /bunch. The magnitude of positron polarization has been determined to be 73 +/- 15(stat) +/- 19(syst)% by means of a newly designed positron polarimeter.

16.
Phys Rev Lett ; 92(5): 054802, 2004 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-14995314

RESUMO

For high luminosity in electron-positron linear colliders, it is essential to generate low vertical emittance beams. We report on the smallest vertical emittance achieved in single-bunch-mode operation of the Accelerator Test Facility, which satisfies the requirement of the x-band linear collider. The emittances were measured with a laser-wire beam-profile monitor installed in the damping ring. The bunch length and the momentum spread of the beam were also recorded under the same conditions. The smallest vertical rms emittance measured at low intensity is 4 pm at a beam energy of 1.3 GeV, which corresponds to the normalized emittance of 1.0x1.0(-8) m. It increases by a factor of 1.5 for a bunch intensity of 10(10) electrons. The measured data agreed to the calculation of intrabeam scattering within much better than a factor of 2.

17.
Arch Androl ; 47(3): 191-4, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11695842

RESUMO

Specific assays have been developed for bioactive inhibin dimers, inhibin A and B, and inhibin alpha-subunit precursor pro alphaC. To better understand the role of serum inhibin pro alphaC in infertile men, the authors measured these forms of inhibin in sera from 39 infertile men and analyzed inhibin relationships with serum gonadotropins, testosterone, and estradiol. All subjects had oligozoospermia. Inhibin A levels were undetectable in all subjects. Inhibin B concentrations were 117 +/- 59 pg/mL. Inhibit B concentrations correlated negatively with serum FSH (r = .584, p < .0001) and positively with sperm count (p < .01) and bilateral testicular volume (r = .607, p < .0001). The concentration of pro alphaC was 556 +/- 236 pg/mL (normal range, 446 +/- 28). Inhibin pro alphaC showed no correlation with serum FSH, LH, testosterone, sperm concentration, and bilateral testicular volume. In addition, inhibin pro alphaC was not correlated with inhibin B. Pro alphaC is unlikely to be a useful marker for spermatogenesis in infertile men compared with inhibin B.


Assuntos
Infertilidade Masculina/sangue , Inibinas/sangue , Precursores de Proteínas/sangue , Adulto , Estradiol/sangue , Gonadotropinas/sangue , Humanos , Infertilidade Masculina/etiologia , Masculino , Oligospermia/sangue , Oligospermia/complicações , Valores de Referência , Contagem de Espermatozoides , Testículo/patologia , Testosterona/sangue
18.
Chemistry ; 7(14): 3134-51, 2001 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-11495440

RESUMO

The architecture of windmill hexameric zinc(II) -porphyrin array 1 is attractive as a light-harvesting functional unit in view of its three-dimensionally extended geometry that is favorable for a large cross-section of incident light as well as for a suitable energy gradient from the peripheral porphyrins to the meso-meso-linked diporphyrin core. Three core-modified windmill porphyrin arrays 2-4 were prepared for the purpose of enhancing the intramolecular energy-transfer rate and coupling these arrays with a charge-separation functional unit. Bisphenylethynylation at the meso and meso' positions of the diporphyrin core indeed resulted in a remarkable enhancement in the intramolecular S1-S1 energy transfer in 2 with tau=2 approximately 3 ps, as revealed by femtosecond time-resolved transient absorption spectroscopy. The fluorescence lifetime of the S2 state of the peripheral porphyrin energy donor determined by the fluorescence up-conversion method was 68 fs, and thus considerably shorter than that of the reference monomer (150 fs), suggesting the presence of the intramolecular energy-transfer channel in the S2 state manifold. Such a rapid energy transfer can be understood in terms of large Coulombic interactions associated with the strong Soret transitions of the donor and acceptor. Picosecond time-resolved fluorescence spectra and transient absorption spectra revealed conformational relaxation of the S1 state of the diporphyrin core with tau = 25 ps. Upon photoexcitation of models 3 and 4, which bear a naphthalenetetracarboxylic diimide or a meso-nitrated free-base porphyrin attached to the modified diporphyrin core as an electron acceptor, a series of photochemical processes proceeded, such as the collection of the excitation energy at the diporphyrin core, the electron transfer from the S1 state of the diporphyrin to the electron acceptor, and the electron transfer from the peripheral porphyrins to the diporphyrin cation radical, which are coupled to provide a fully charge-separated state such as that in the natural photosynthetic reaction center. The overall quantum yield for the full charge separation is better in 4 than in 3 owing to the slower charge recombination associated with smaller reorganization energy of the porphyrin acceptor.

19.
Kyobu Geka ; 54(8 Suppl): 719-21, 2001 Jul.
Artigo em Japonês | MEDLINE | ID: mdl-11517538

RESUMO

A 65-year-old woman was admitted to the hospital because of anterior chest pain. Computed tomography and transthoracic 2-D echocardiogram demonstrated aortic valvular stenosis with calcification of whole aortic root. Cardiac catheterization study showed a transaortic pressure gradient of 73 mmHg and coronary angiography showed 75% stenosis at the right coronary ostia. Aortic valve replacement and coronary artery bypass grafting were planned. At operation, sinotubular junction and bilateral coronary ostia severely calcified with stenosis, prompted us to translocate the aortic valve with the composite graft, a 19 mm Bicarbon prosthesis and 25 mm woven Dacron graft. The postoperative course was uneventful. On cardiac catheterization done 27 days after operation, satisfactory valve motion and patent coronary bypass grafts were confirmed.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese Vascular , Calcinose/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Idoso , Estenose da Valva Aórtica/patologia , Feminino , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...