Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Water Sci Technol ; 87(8): 2005-2019, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37119169

RESUMO

Owing to the low ratio of chemical oxygen demand to total nitrogen (SCOD/TN), effective removal of nutrient pollutants from black water is difficult. In this study, to enhance nitrogen and phosphorus removal from such wastewater, a series of operational modification strategies was investigated and applied to a plant-scale semi-centralized system used for black water treatment. The results showed that 21 mg Fe3+/L was the optimal dosage for the chemical-enhanced pretreatment process, achieving average removal efficiencies of 51.1 and 74.1% for organics and phosphorus, respectively, with a slight enhancement in nitrogen removal by 2.3%. However, nitrogen and phosphorus removal could be further enhanced to 88 and 96%, by the addition of carbon sources in the post-anoxic zone of the reversed anaerobic-anoxic-aerobic process. Contrastingly, neither the addition of carbon sources in the pre-anoxic zone nor the prolongation of the time for pre-denitrification could significantly improve the nitrogen and phosphorus removal efficiencies. Furthermore, reducing the aeration intensity promoted simultaneous nitrification and denitrification in aerobic reactors, thereby making it a potential energy-saving method for system operation.


Assuntos
Fósforo , Purificação da Água , Eliminação de Resíduos Líquidos/métodos , Desnitrificação , Nitrogênio , Reatores Biológicos , Nitrificação , Purificação da Água/métodos , Carbono , Esgotos
2.
Sci Rep ; 11(1): 16962, 2021 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-34417482

RESUMO

In engineering practice, the measured bearing capacity of a sand pile composite foundation in a mucky soil layer is much larger than the design value. Based on the sand pile construction and the load application process, a method of calculating the bearing capacity of the foundation based on the effective stress was proposed. Cavity diameter expansion in sand pile construction was simplified into a planar problem, and the cavity expansion theory was used to establish the expression of the rate of displacement and the horizontal stress increase. Based on the e-p curve and the calculation of the degree of consolidation, the relationships between the horizontal and vertical effective stress and the void ratio were obtained. According to the close relationship between the bearing capacity of the foundation in a mucky soil layer and the water content, an expression describing the relationships between the bearing capacity of the foundation, effective stress, void ratio, and water content was established. For the temporary engineering foundation treatment project, which needs a high bearing capacity but allows large foundation deformation, the design of sand pile composite foundations uses these relationships to take the consolidation effect of mucky soil into consideration, thereby reducing the replacement rate and lowering the construction cost.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...