Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
J Dent ; 146: 105061, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38729289

RESUMO

OBJECTIVES: Orthognathic surgery (OS) has evolved with technological advancements, notably through the implementation of computer-assisted orthognathic surgery (CAOS). This article aims to elucidate various types of CAOS and their efficiency and accuracy, supplemented by a thorough literature review focusing on their clinical applications in South Korea. STUDY SELECTION, DATA, AND SOURCES: A comprehensive search strategy was employed, including systematic reviews, meta-analyses, randomized controlled trials, and observational studies published until December 2023 in the PubMed, MEDLINE, and Google Scholar databases. The literature search was limited to articles written in English. RESULTS: Static CAOS demonstrated high precision, reduced operative time, and high accuracy, suggesting its potential reliability in orthognathic procedures. Dynamic CAOS presented a promising avenue for exploration, showing an accuracy comparable to that of traditional methods. The critical considerations for CAOS include accuracy, time efficiency, and cost-effectiveness. Recent studies have indicated advancements in the time efficiency of static CAOS. Static CAOS requires less equipment and is more cost-effective than dynamic CAOS. CONCLUSIONS: CAOS offers clear advantages over conventional OS in terms of surgical convenience and accuracy in implementing the surgical plan. To achieve recognition as the gold standard method for maxillofacial deformity treatment, CAOS must overcome its limitations and undergo continuous verification via well-designed studies. CLINICAL SIGNIFICANCE: The introduction of CAOS, mainly static CAOS with high precision and reduced surgical time, signifies a notable advancement in OS. However, rigorous studies are warranted to validate CAOS as the gold standard for treating maxillofacial deformities.

2.
Bioengineering (Basel) ; 11(4)2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38671740

RESUMO

With the growing demand for orthognathic surgery and other facial treatments, the accurate identification of anatomical landmarks has become crucial. Recent advancements have shifted towards using three-dimensional radiologic analysis instead of traditional two-dimensional methods, as it allows for more precise treatment planning, primarily relying on direct identification by clinicians. However, manual tracing can be time-consuming, mainly when dealing with a large number of patients. This study compared the accuracy and reliability of identifying anatomical landmarks using artificial intelligence (AI) and manual identification. Thirty patients over 19 years old who underwent pre-orthodontic and orthognathic surgery treatment and had pre-orthodontic three-dimensional radiologic scans were selected. Thirteen anatomical indicators were identified using both AI and manual methods. The landmarks were identified by AI and four experienced clinicians, and multiple ANOVA was performed to analyze the results. The study results revealed minimal significant differences between AI and manual tracing, with a maximum deviation of less than 2.83 mm. This indicates that utilizing AI to identify anatomical landmarks can be a reliable method in planning orthognathic surgery. Our findings suggest that using AI for anatomical landmark identification can enhance treatment accuracy and reliability, ultimately benefiting clinicians and patients.

3.
J Dent ; : 105030, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38685341

RESUMO

OBJECTIVES: Temporomandibular disorder (TMD) is a common condition that affects the temporomandibular joint (TMJ) and the muscles of the jaw, resulting in pain and dysfunction. TMD is affected by both behavioral and psychological factors. Digital therapeutics (DTx) can exert therapeutic effects by controlling behavioral factors through the delivery of appropriate interventions. Here, we report an open-label randomized control trial to evaluate the efficacy of DTx for TMD. METHODS: We recruited 40 participants diagnosed with TMD. Participants were randomly divided into an intervention group (DTx use, n = 20) and a control group (n =20). The intervention group received the usual treatment process for TMD in addition to the use of the DTx. The control group received the usual treatments only. Patients in both groups were followed up for 3-4 weeks, and outcome data were collected and analyzed. RESULT: The intervention group showed a significant reduction in pain scores as measured by the numerical rating scale (NRS) (p = 0.016). Additionally, the intervention group showed a statistically significant increase in maximal mouth opening compared to the control group (p = 0.0079). However, there were no significant differences in improvement in the Jaw Functional Limitation Scale, Oral Behavior Checklist, and Patient Health Questionnaire-4 between the two groups (p = 0503, = 0.820, and = 0.943, respectively). CONCLUSION: This RCT reveals DTx potential in TMD, showing pain and mouth opening improvements with conventional treatment. But no significant changes were noted in other outcomes. The findings advocate for more extensive, long-term research to solidify DTx's role in TMD management. CLINICAL SIGNIFICANCE: This research underlines DTx potential to improve pain outcomes in TMD therapy, reinforcing its value as a complementary treatment modality.

4.
Sci Rep ; 14(1): 3397, 2024 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-38336901

RESUMO

Ridge resorption can result in insufficient bone volume for implant surgery, necessitating bone substitutes to restore the resorption area. Recent advances in computer-aided design and manufacturing enable the use of alloplastic bone graft materials with customizable compositions or shapes. This randomized study evaluated the clinical effectiveness of a customized three-dimensional (3D) printed alloplastic bone material. Sixty patients requiring guided bone regeneration for implant installation following tooth extraction due to alveolar bone resorption were recruited at two institutions. The participants were randomly allocated to either a group that received 3D-printed patient-customized bone graft material or a group that received conventional block bone graft material. Implant installation with bone harvesting was performed approximately 5 months after bone grafting. Histological and radiological assessments of the harvested bone area were performed. The experimental group had a significantly higher percent bone volume and a smaller tissue surface than the control group. Bone volume, bone surface, bone surface/volume ratio, bone surface density (bone surface/total volume), and bone mineral density did not differ significantly between groups. Patient-customized bone graft materials offer convenience and reduce patient discomfort. The findings suggest 3D-printed patient-customized bone graft materials could be used as an alternative for simpler bone grafting procedures.


Assuntos
Perda do Osso Alveolar , Substitutos Ósseos , Humanos , Transplante Ósseo/métodos , Estudos Prospectivos , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/cirurgia , Regeneração Óssea , Cerâmica
5.
Bioengineering (Basel) ; 10(9)2023 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-37760107

RESUMO

Recombinant human bone morphogenetic protein-2 (rhBMP-2) has shown potential in maxillofacial surgery owing to its osteoinductive properties. However, concerns about its safety and high cost have limited its widespread use. This review presents the status of rhBMP-2 use in maxillofacial surgery, focusing on its clinical application, efficacy, safety, and limitations. Studies have demonstrated rhBMP-2's potential to reduce donor site morbidity and increase bone height in sinus and ridge augmentation; however, it may not outperform autogenous bone grafts. In medication-related osteonecrosis of the jaw treatment, rhBMP-2 has been applied adjunctively with promising results, although its long-term safety requires further investigation. However, in maxillofacial trauma, its application is limited to the restoration of large defects. Safety concerns include postoperative edema and the theoretical risk of carcinogenesis. Although postoperative edema is manageable, the link between rhBMP-2 and cancer remains unclear. The limitations include the lack of an ideal carrier, the high cost of rhBMP-2, and the absence of an optimal dosing regimen. In conclusion, rhBMP-2 is a promising graft material for maxillofacial surgery. However, it has not yet become the gold standard owing to safety and cost concerns. Further research is required to establish long-term safety, optimize dosing, and develop better carriers.

6.
Bioengineering (Basel) ; 10(8)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37627799

RESUMO

Maxillofacial skeletal surgery often involves the use of patient-specific implants. However, errors in obtaining patient data and designing and manufacturing patient-specific plates and guides can occur even with accurate virtual surgery. To address these errors, bespoke Snowman plates were designed to allow movement of the mandible. This study aimed to compare the stability of bespoke four-hole miniplates with that of a bespoke Snowman plate for bilateral sagittal split ramus osteotomy (SSRO), and to present a method to investigate joint cavity changes, as well as superimpose virtual and actual surgical images of the mandible. This retrospective study included 22 patients who met the inclusion criteria and underwent orthognathic surgery at a university hospital between 2015 and 2018. Two groups were formed on the basis of the plates used: a control group with four-hole bespoke plates and a study group with bespoke Snowman plates. Stability was assessed by measuring the condyle-fossa space and superimposing three-dimensional virtual surgery images on postoperative cone-beam computed tomography (CBCT) scans. No significant differences were observed in the condyle-fossa space preoperatively and 1 year postoperatively between the control and study groups. Superimposing virtual surgery and CBCT scans revealed minimal differences in the landmark points, with no variation between groups or timepoints. The use of bespoke Snowman plates for stabilizing the mandible following SSRO exhibited clinical stability and reliability similar to those with bespoke four-hole plates. Additionally, a novel method was introduced to evaluate skeletal stability by separately analyzing the condyle-fossa gap changes and assessing the mandibular position.

7.
J Dent ; 137: 104650, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37544353

RESUMO

OBJECTIVES: Surgeons often encounter challenges when treating maxillofacial fractures using conventional methods that involve trimming or bending ready-made titanium plates for open reduction and internal fixation (ORIF) since it can be time-consuming, imprecise, and inconvenient. This retrospective case series aimed to introduce a novel bone reduction method that utilizes virtual planning, patient-specific surgical guides, and titanium plates. METHODS: Seven patients with mandibular symphysis or subcondylar fractures resulting from facial trauma underwent cone-beam computed tomography (CBCT) or facial CT scans, and their medical histories were documented. Virtual surgery was conducted based on three-dimensional (3D) stereolithography images derived from CT scans using the FaceGide software (MegaGen, Daegu, Korea). ORIF was performed using patient-specific surgical guides and plates that were designed, printed, and milled. Radiographic, clinical, and occlusal evaluations were conducted at two weeks and six weeks postoperatively. Subsequently, 3D images from virtual surgery and postoperative CT scans were compared. RESULTS: The comparison of 3D virtual surgery and postoperative images revealed minimal surface differences of less than 1 mm. T-scan evaluations indicated that there were no statistically significant differences between the two- and six-week postoperative assessments. Favorable clinical outcomes were observed. CONCLUSION: This novel method demonstrated stable outcomes in terms of occlusion and healing, with no notable complications. Consequently, this approach may serve as a viable alternative to conventional methods. CLINICAL SIGNIFICANCE: Facial fracture surgery that utilizes patient-specific surgical guides and plates within a digital workflow can facilitate meticulous surgical planning, reducing the risk of complications and minimizing operation time.


Assuntos
Fixação Interna de Fraturas , Fraturas Ósseas , Humanos , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Titânio , Fraturas Ósseas/cirurgia , Tomografia Computadorizada por Raios X
8.
Sci Rep ; 13(1): 10603, 2023 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-37391453

RESUMO

Distortion of dentition may occur in cone-beam computed tomography (CBCT) scans due to artifacts, and further imaging is frequently required to produce digital twins. The use of a plaster model is common; however, it has certain drawbacks. This study aimed to assess the feasibility of different digital dentition models over that of plaster casts. Plaster models, alginate impressions, intraoral scan (IOS) images, and CBCT images of 20 patients were obtained. The desktop model scanner was used to scan the alginate impression twice, five minutes and two hours after impression-making. Using an IOS, the full arch was scanned in segments using CS 3600 and simultaneously with i700 wireless. The digital twins obtained from the alginate impression and IOS were superimposed with those obtained from the plaster cast. The differences and distances at each reference point were measured. Scans of alginate impressions after two hours showed the greatest discrepancies, but these were all less than the CBCT voxel size of 0.39 mm. Alginate impression scans and IOS are suitable supplements to CBCT compared to the plaster model. Accuracy can be improved by scanning the alginate impression within five minutes or by intraoral scanning of the entire arch with segmentation.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Dentição , Humanos , Alginatos , Artefatos , Hematopoiese Clonal
9.
Bioengineering (Basel) ; 10(5)2023 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-37237615

RESUMO

BACKGROUND: Multi-dimensional facial imaging is increasingly used in hospital clinics. A digital twin of the face can be created by reconstructing three-dimensional (3D) facial images using facial scanners. Therefore, the reliability, strengths, and weaknesses of scanners should be investigated and approved; Methods: Images obtained from three facial scanners (RayFace, MegaGen, and Artec Eva) were compared with cone-beam computed tomography images as the standard. Surface discrepancies were measured and analyzed at 14 specific reference points; Results: All scanners used in this study achieved acceptable results, although only scanner 3 obtained preferable results. Each scanner exhibited weak and strong points because of differences in the scanning methods. Scanner 2 exhibited the best result on the left endocanthion; scanner 1 achieved the best result on the left exocanthion and left alare; and scanner 3 achieved the best result on the left exocanthion (both cheeks); Conclusions: These comparative analysis data can be used when creating digital twins through segmentation, selecting and merging data, or developing a new scanner to overcome all shortcomings.

10.
Sci Rep ; 12(1): 20585, 2022 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-36446924

RESUMO

Lateral cephalograms and related analysis constitute representative methods for orthodontic treatment. However, since conventional cephalometric radiographs display a three-dimensional structure on a two-dimensional plane, inaccuracies may be produced when quantitative evaluation is required. Cone-beam computed tomography (CBCT) has minimal image distortion, and important parts can be observed without overlapping. It provides a high-resolution three-dimensional image at a relatively low dose and cost, but still shows a higher dose than a lateral cephalogram. It is especially true for children who are more susceptible to radiation doses and often have difficult diagnoses. A conventional lateral cephalometric radiograph can be obtained by reconstructing the Digital Imaging and Communications in Medicine data obtained from CBCT. This study evaluated the applicability and consistency of lateral cephalograms generated by CBCT using an artificial intelligence analysis program. Group I comprised conventional lateral cephalometric radiographs, group II comprised lateral cephalometric radiographs generated from CBCT using OnDemand 3D, and group III comprised lateral cephalometric radiographs generated from CBCT using Invivo5. All measurements in the three groups showed non-significant results. Therefore, a CBCT scan and artificial intelligence programs are efficient means when performing orthodontic analysis on pediatric or orthodontic patients for orthodontic diagnosis and planning.


Assuntos
Inteligência Artificial , Tomografia Computadorizada de Feixe Cônico , Humanos , Criança , Cefalometria , Radiografia , Assistência Odontológica
11.
J Funct Biomater ; 13(4)2022 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-36412880

RESUMO

The aim of this study was to compare the mechanical behaviors of three dental implant fixtures with different abutment connection designs. Three implant systems were studied: the control (BLX implant), test group 1 (TORX++ implant), and test group 2 (IU implant). Three samples from each group were subjected to static compression to fracture tests to determine the maximum fracture load, and twelve samples were exposed to fatigue tests that measured how many cycles the implants could endure before deformation or fracture. Detailed images of the implant-abutment assemblies were obtained using micro-computed tomography imaging, and fractured or deformed areas were observed using a scanning electron microscope (SEM). The mean maximum breaking loads of 578.45 ± 42.46 N, 793.26 ± 57.43 N, and 862.30 ± 74.25 N were obtained for the BLX, TORX++, and IU implants, respectively. All samples in the three groups withstood 5 × 106 cycles at 50% of the nominal peak value, and different fracture points were observed. All abutment connection designs showed suitable mechanical properties for intraoral use. Microscopic differences in the fracture patterns may be due to the differences in the fixture design or abutment connection, and mechanical complications could be prevented by lowering the overload reaching the implant or preventing peri-implantitis.

12.
Bioengineering (Basel) ; 9(10)2022 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-36290451

RESUMO

(1) Background: The stability of implants plays a significant role in the success of osseointegration. The stability of the connection between the fixture and the abutment is one of the critical factors affecting osseointegration. When restoring multiple, non-parallel, and splinted implants, achieving a passive fit can be complicated and challenging. A new EZ post non-engaging abutment system of the BlueDiamond® (BD) implant allows a wide connection angle while achieving a passive prosthesis fit. This study aimed to confirm the new abutment system's clinical applicability by evaluating its biomechanical characteristics using finite element analysis (FEA). (2) Methods: The implant-supported fixed three-unit dental prostheses model was reproduced for two groups of AnyOne® (AO) and BD implants using FEA. The loading conditions were a preload of 200 N in the first step and loads of 100 N (axial), 100 N (15°), or 30 N (45°) in the second step. (3) Results: The peak Von Mises stress (PVMS) value of the fixture in the BD group was more than twice that in the AO group. In contrast, the PVMS values of the abutment and abutment screws were lower in the BD group than in the AO group. The AO group revealed higher maximal principal stress (MPS) values than that of the BD group in the cortical bone, cancellous bone, and crown. The average stress of the outer surface of the abutment was lower in the AO group than in the BD group. The stress distribution for the inner surface of the fixture confirmed that the BD group displayed a lower stress distribution than the AO group under axial and 15° loads; however, the average stress was 1.5 times higher at the 45° load. The stress values of the entire surface where the cortical and cancellous bone were in contact with the fixture were measured. The AO group showed a higher stress value than the BD group in both cortical and cancellous bone. (4) Conclusions: In the AO group, the PVMS value of the fixture and the stress distribution at the contact surface between the fixture and the abutment were lower than those of the BD group, suggesting that the stability of the fixture would be high. However, due to the high stress in the fastening area of the abutment and abutment screw, the risk of abutment fracture in the AO group is higher than that of the BD group. Therefore, the new EZ post non-engaging abutment of the BD implant can be used without any problems in clinics, similar to the non-engaging abutment of the AO implant, which has been widely used in clinical practice.

13.
Scanning ; 2022: 8221514, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35316954

RESUMO

Cone-beam computed tomography (CBCT) can distort dentition, and additional imaging is often required. A plaster model to help digitize dental images has been widely used in clinical practice, but there are some inconveniences such as complexity of the process and the risk of damage. The aim of this study was to evaluate the potential for improving dentition imaging with CBCT scans using an intraoral scanner instead of a plaster model. The study used laser model-scanned images of plaster models, imaging from two intraoral scanners, and CBCT images from 20 patients aged 12-18 years. CS 3600 (Carestream Dental, Atlanta, USA) and i700 (Medit, Seoul, Korea) were used as intraoral scanners. The full arch was scanned at once or in three sections using intraoral scanners. The segmented scans were merged to obtain full-arch images. With i700, full-arch images were additionally acquired using its "smart stich" function. The virtual skull-dentition hybrid images obtained from intraoral scanners were superimposed with images obtained using a plaster cast. The difference and distance of coordinate values at each reference point were measured. The average distances from the images obtained with the plaster cast were smaller than 0.39 mm, which is the voxel size of CBCT. Scanning the complete or partial arch using CS 3600 or i700 satisfactorily complemented the CBCT when compared to the plaster model. The virtual skull-dentition hybrid image obtained from intraoral scanners will be clinically useful, especially for patients and surgeons who have difficulty in scanning the complete arch at once.


Assuntos
Dentição , Modelos Dentários , Adolescente , Criança , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Imageamento Tridimensional/métodos , Crânio/diagnóstico por imagem
14.
Biology (Basel) ; 11(3)2022 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-35336755

RESUMO

Aim. To investigate the effect of changes in incisor tip, apex movement, and inclination on skeletal points A and B and characterize changes in skeletal points A and B to the soft tissue points A and B after incisor retraction in Angle Class I bimaxillary dentoalveolar protrusion. Methods. Twenty-two patients with Angle Class I bimaxillary dentoalveolar protrusion treated with four first premolar extractions were included in this study. The displacement of skeletal and soft tissue points A and B was measured using cone-beam computed tomography (CBCT) using a three-dimensional coordinate system. The movement of the upper and lower incisors was also measured using CBCT-synthesized lateral cephalograms. Results. Changes in the incisal tip, apex, and inclination after retraction did not significantly affect the position of points A and B in any direction (x, y, z). Linear regression analysis showed a statistically significant relationship between skeletal point A and soft tissue point A on the anteroposterior axis (z). Skeletal point A moved forward by 0.07 mm, and soft tissue point A moved forward by 0.38 mm, establishing a ratio of 0.18: 1 (r = 0.554, p < 0.01). Conclusion. The positional complexion of the skeletal points A and B was not directly influenced by changes in the incisor tip, apex, and inclination. Although the results suggest that soft tissue point A follows the anteroposterior position of skeletal point A, its clinical significance is suspected. Thus, hard and soft tissue analysis should be considered in treatment planning.

15.
Int J Mol Sci ; 22(21)2021 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-34768914

RESUMO

Our aim was to investigate the bone regeneration capacity of powder-type biphasic ceramic scaffold (BCP powder), block-type BCP (BCP block), and collagen-added block-type BCP (BCP collagen) with different concentrations of recombinant human bone morphogenetic protein 2 (rhBMP-2) in an animal model. Four rabbits were assigned to each of the following groups: no graft + rhBMP-2 (0.1/0.2 mg/mL), BCP powder + rhBMP-2 (0.1/0.2 mg/mL), BCP block + rhBMP-2 (0.1/0.2 mg/mL), and BCP collagen + rhBMP-2 (0.1/0.2 mg/mL), i.e., a total of 32 rabbits. Polycarbonate tubes (Φ 7 mm × 5 mm) for supporting scaffolds were fixed into a 7 mm round border. Subsequently, 0.1 mL of rhBMP-2 solutions with different concentrations was injected into the tubes. Both radiological and histomorphometric analyses showed that osteogenesis was not enhanced by increasing the concentration of rhBMP-2 in all groups at both 3 and 6 weeks. Radiological analysis showed that bone formation was higher in the BCP collagen group than in the BCP powder and BCP block groups at both rhBMP-2 concentrations at 3 weeks. rhBMP-2 enhanced bone formation; however, as the concentration increased, bone formation could not be enhanced infinitely. Collagen-added alloplastic graft material may be useful for mediating rapid bone formation in initial stages.


Assuntos
Doenças Ósseas/terapia , Proteína Morfogenética Óssea 2/administração & dosagem , Regeneração Óssea , Cerâmica/química , Osteogênese , Fraturas Cranianas/terapia , Alicerces Teciduais/química , Fator de Crescimento Transformador beta/administração & dosagem , Animais , Doenças Ósseas/metabolismo , Doenças Ósseas/patologia , Proteína Morfogenética Óssea 2/metabolismo , Masculino , Coelhos , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/metabolismo , Fraturas Cranianas/metabolismo , Fraturas Cranianas/patologia , Fator de Crescimento Transformador beta/metabolismo
16.
Int J Mol Sci ; 22(22)2021 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-34830400

RESUMO

This study aimed to evaluate the bone regeneration capacity of a customized alloplastic material and xenograft with recombinant human bone morphogenetic protein-2 (rhBMP-2). We prepared hydroxyapatite (HA)/tricalcium phosphate (TCP) pure ceramic bone blocks made using a 3D printing system and added rhBMP-2 to both materials. In eight beagle dogs, a total of 32 defects were created on the lower jaws. The defective sites of the negative control group were left untreated (N group; 8 defects), and those in the positive control group were filled with particle-type Bio-Oss (P group; 12 defects). The defect sites in the experimental group were filled with 3D-printed synthetic bone blocks (3D group; 12 defects). Radiographic and histological evaluations were performed after healing periods of 6 and 12 weeks and showed no significant difference in new bone formation and total bone between the P and 3D groups. The 3D-printed custom HA/TCP graft with rhBMP-2 showed bone regeneration effects similar to that of particulate Bio-Oss with rhBMP-2. Through further study and development, the application of 3D-printed customized alloplastic grafts will be extended to various fields of bone regeneration.


Assuntos
Proteína Morfogenética Óssea 2/genética , Regeneração Óssea/genética , Anormalidades Maxilomandibulares/terapia , Desenvolvimento Maxilofacial/genética , Fator de Crescimento Transformador beta/genética , Animais , Proteína Morfogenética Óssea 2/farmacologia , Regeneração Óssea/efeitos dos fármacos , Substitutos Ósseos/farmacologia , Fosfatos de Cálcio/farmacologia , Cães , Durapatita/farmacologia , Humanos , Arcada Osseodentária/patologia , Anormalidades Maxilomandibulares/genética , Anormalidades Maxilomandibulares/patologia , Impressão Tridimensional , Proteínas Recombinantes/genética , Proteínas Recombinantes/farmacologia , Crânio/efeitos dos fármacos , Crânio/crescimento & desenvolvimento , Crânio/patologia , Fator de Crescimento Transformador beta/farmacologia
17.
J Clin Med ; 10(19)2021 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-34640397

RESUMO

During extraction surgery, the inferior alveolar nerve (IAN) can occasionally be observed in the extraction socket of the mandibular third molar (M3). The purpose of this study was to investigate and compare the incidence of IAN injury in groups with and without intraoperative IAN exposure during surgical extraction of M3, and to identify additional risk factors for the IAN injury in addition to the IAN exposure. A total of 288 cases in 240 patients, who underwent surgical extraction of M3 by a single surgeon, were divided into the exposed group (n = 69) and the unexposed group (n = 219). The surgeon recorded the information regarding the procedure when the clinical observation of IAN exposure was made during the surgery. The incidence of IAN injury after the extraction surgery was significantly higher in the exposed group than in the unexposed group (4.3% versus 0%, p < 0.05). Paresthesia was recognized in three cases of the exposed group, but it showed complete recovery within three postoperative months. No case of permanent paresthesia was detected in both groups. According to the logistic regression, the only significant risk factor of IAN injury in the exposed group was the increase of age (OR 1.108, p < 0.05). Intraoperative IAN exposure during surgical extraction of M3 may show a higher incidence of IAN injury than the case without IAN exposure, representing an incidence of 4.3%. Even if the paresthesia associated with IAN exposure occurs, it is likely to be a temporary injury, and this risk may increase with age.

18.
Sci Rep ; 11(1): 11470, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34075179

RESUMO

This study evaluated the bone regeneration capacity and mechanical properties of block-type hydroxyapatite (HA)/tricalcium phosphate (TCP) scaffolds in response to different concentrations of polydeoxyribonucleotide (PDRN) and recombinant human bone morphogenic protein 2 (rhBMP-2). Thirty-two male white rabbits were used as a model of calvarial bone defect and classified into eight groups according to type and concentration of growth factor administered, viz., control group (only HA/TCP scaffold), scaffold + PDRN (0.1, 1, 5, and 10 mg/mL each) and scaffold + rhBMP-2 (0.01, 0.05, and 0.1 mg/mL each). The specimens were evaluated using histomorphometric and radiological analyses. Histomorphometric analyses indicated that the administration of PDRN did not increase bone formation. However, significant increases in bone formation were observed with the administration of rhBMP-2 at 0.05 and 0.10 mg/mL on week 8 compared to the control (p < 0.05). Radiological analyses revealed a significant increase in bone formation at week 8 with the administration of PDRN at 5 mg/mL and 10 mg/mL, and rhBMP-2 at 0.05 or 0.10 mg/mL compared to the control (p < 0.05). Our findings show that block-type HA/TCP scaffolds possess sufficient mechanical strength and bone regeneration capacity when used with optimal concentrations of growth factors.


Assuntos
Proteína Morfogenética Óssea 2 , Regeneração Óssea/efeitos dos fármacos , Cerâmica/química , Oligonucleotídeos/química , Crânio , Animais , Proteína Morfogenética Óssea 2/química , Proteína Morfogenética Óssea 2/farmacocinética , Proteína Morfogenética Óssea 2/farmacologia , Fosfatos de Cálcio/química , Durapatita/química , Humanos , Masculino , Oligonucleotídeos/farmacocinética , Oligonucleotídeos/farmacologia , Coelhos , Proteínas Recombinantes/química , Proteínas Recombinantes/farmacocinética , Proteínas Recombinantes/farmacologia , Crânio/lesões , Crânio/metabolismo
19.
Biomed Res Int ; 2021: 5545620, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33816614

RESUMO

It was hypothesized that periodontal diseases could be influenced by nutrition and food types. However, the role of nutritional factors in the risk of periodontal disease has not been clearly elucidated. This study was aimed at investigating the relationship between coffee, green tea, or soft drink intake and periodontitis. This prospective cohort study used epidemiological data from 2004 to 2016 from the Korean Genome and Epidemiology Study. Among 173,209 participants, 9,933 with periodontitis and 124,922 controls were selected. The frequency histories of coffee/green tea/soft drink intake among the participants were analyzed, and intake was categorized as no drink, mild drink (one time a month through six times a week), and heavy drink (one or more times a day). Variable factors were adjusted using logistic regression analysis (adjusted model). The chi-square test and independent t-test were used for statistical analysis. Adjusted odds ratio (aOR) for coffee or green tea intake and periodontitis were not statistically significant. The aOR was 1.16 (95% confidence interval (CI) = 1.11-1.21, P < 0.001) for mild soft drink intake and 1.02 (95%CI = 0.96-1.09, P = 0.518) for heavy soft drink intake. Subgroup analysis showed that mild soft drink intake was significant across all groups (P < 0.05), whereas coffee and green tea intakes were not significant in any subgroup. Overall, the study elucidated an association between mild soft drink intake and periodontitis.


Assuntos
Bebidas Gaseificadas/efeitos adversos , Café/efeitos adversos , Bases de Dados Factuais , Periodontite , Chá/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estado Nutricional , Periodontite/induzido quimicamente , Periodontite/epidemiologia , Estudos Prospectivos , Fatores de Risco
20.
J Clin Med ; 10(8)2021 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-33918920

RESUMO

OBJECTIVE: Orthognathic surgery (OGS) is a surgical intervention that corrects dentofacial deformities through the movement of maxillary and mandibular segments to achieve adequate masticatory function, joint health, and facial harmony. However, some patients present with occlusal discrepancies, condylar sag, and/or temporomandibular disorders after OGS. Various methods have been employed to solve these problems after surgery. This study aimed to evaluate the effectiveness of early screw removal in patients with occlusal discrepancies after OGS using three-dimensional cone-beam computed tomography (CBCT). METHODS: In 44 patients with dentofacial deformities, patient-customized OGSs with customized plates were performed to correct facial deformities using customized guides with computer-aided surgical simulation. Of the 44 patients, eight patients complained of occlusal discrepancies and temporomandibular disorders after OGS. These eight patients underwent screw removal under local anesthesia around four weeks. The temporomandibular joint spaces at three time points (pre-surgical, post-surgical, and after screw removal) in the sagittal and coronal planes were compared using CBCT. RESULTS: Eight patients showed an increase in joint space on CBCT images immediately after surgery (T1), but after early screw removal (T2), these spaces almost returned to their pre-surgical state, and the temporomandibular joint problem disappeared. CONCLUSIONS: The removal of screws located in the distal segment under local anesthesia between three and four weeks post-surgically may be a treatment option for patients with post-OGS occlusal discrepancies, condylar sag, and/or temporomandibular disorder.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...