Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Sci Technol ; 2021 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34328323

RESUMO

Subway PM2.5 can be substantially sourced from the operation of the system itself. Improvements in subway air quality may be possible by examining the potential to reduce these emissions. To this end, PM2.5 was measured on the trains and station platforms of the Toronto subway system. A comparison with previously published data for this system reveals significant changes in below ground platform PM2.5. A reduction of nearly one-third (ratio (95% CI): 0.69 (0.63, 0.75)) in PM2.5 from 2011 to 2018 appears to have resulted from a complete modernization of the rolling stock on one subway line. In contrast, below ground platform PM2.5 for another line increased by a factor of 1.48 (95% CI; 1.42, 1.56). This increase may be related to an increase in emergency brake applications, the resolution of which coincided with a large decrease in PM2.5 concentrations on that line. Finally, platform PM2.5 in two newly opened stations attained, within one year of operation, typical concentrations of the neighboring platforms installed in 1963. Combined, these findings suggest that the production of platform PM2.5 is localized and hence largely freshly emitted. Further, PM2.5 changed across this subway system due to changes in its operation and rolling stock. Thus, similar interventions applied intentionally may prove to be equally effective in reducing PM2.5. Moreover, establishing a network of platform PM2.5 monitors is recommended to monitor ongoing improvements and identify impacts of future system changes on subway air quality. This would result in a better understanding of the relationship between the operations and air quality of subways.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...