1.
Ultrasonics ; 54(3): 754-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24199954

RESUMO

High performance limiters are described in this paper for applications in high frequency ultrasound imaging systems. Limiters protect the ultrasound receiver from the high voltage (HV) spikes produced by the transmitter. We present a new bipolar power transistor (BPT) configuration and compare its design and performance to a diode limiter used in traditional ultrasound research and one commercially available limiter. Limiter performance depends greatly on the insertion loss (IL), total harmonic distortion (THD) and response time (RT), each of which will be evaluated in all the limiters. The results indicated that, compared with commercial limiter, BPT-based limiter had less IL (-7.7 dB), THD (-74.6 dB) and lower RT (43 ns) at 100 MHz. To evaluate the capability of these limiters, they were connected to a 100 MHz single element transducer and a two-way pulse-echo test was performed. It was found that the -6 dB bandwidth and sensitivity of the transducer using BPT-based limiter were better than those of the commercial limiter by 22% and 140%, respectively. Compared to the commercial limiter, BPT-based limiter is shown to be capable of minimizing signal attenuation, RT and THD at high frequencies and is thus suited for high frequency ultrasound applications.


Assuntos
Amplificadores Eletrônicos , Aumento da Imagem/instrumentação , Transistores Eletrônicos , Ultrassonografia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Imagens de Fantasmas
2.
Artigo em Inglês | MEDLINE | ID: mdl-23143580

RESUMO

The goal of this research was to develop a novel diced 1-3 piezocomposite geometry to reduce pulse-echo ring down and acoustic crosstalk between high-frequency ultrasonic array elements. Two PZT-5H-based 1-3 composites (10 and 15 MHz) of different pillar geometries [square (SQ), 45° triangle (TR), and pseudo-random (PR)] were fabricated and then made into single-element ultrasound transducers. The measured pulse-echo waveforms and their envelopes indicate that the PR composites had the shortest -20-dB pulse length and highest sensitivity among the composites evaluated. Using these composites, 15-MHz array subapertures with a 0.95λ pitch were fabricated to assess the acoustic crosstalk between array elements. The combined electrical and acoustical crosstalk between the nearest array elements of the PR array subapertures (-31.8 dB at 15 MHz) was 6.5 and 2.2 dB lower than those of the SQ and the TR array subapertures, respectively. These results demonstrate that the 1-3 piezocomposite with the pseudo-random pillars may be a better choice for fabricating enhanced high-frequency linear-array ultrasound transducers; especially when mechanical dicing is used.


Assuntos
Transdutores , Ultrassonografia/instrumentação , Cerâmica , Impedância Elétrica , Desenho de Equipamento
3.
J Ultrasound Med ; 31(11): 1795-802, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23091251

RESUMO

We have developed a blood flow measurement system using Doppler ultrasound flow sensors fabricated of thin and flexible piezoelectric-polymer films. These flow sensors can be wrapped around a blood vessel and accurately measure flow. The innovation that makes this flow sensor possible is the diffraction-grating transducer. A conventional transducer produces a sound beam perpendicular to its face; therefore, when placed on the wall of a blood vessel, the Doppler shift in the backscattered ultrasound from blood theoretically would be 0. The diffraction-grating transducer produces a beam at a known angle to its face; therefore, backscattered ultrasound from the vessel will contain a Doppler signal. Flow sensors were fabricated by spin coating a poly(vinylidene fluoride-trifluoroethylene) copolymer film onto a flexible substrate with patterned gold electrodes. Custom-designed battery-operated continuous wave Doppler electronics along with a laptop computer completed the system. A prototype flow sensor was evaluated experimentally by measuring blood flow in a flow phantom and the infrarenal aorta of an adult New Zealand White rabbit. The flow phantom experiment demonstrated that the error in average velocity and volume blood flow was less than 6% for 30 measurements taken over a 2.5-hour period. The peak blood velocity through the rabbit infrarenal aorta measured by the flow sensor was 118 cm/s, within 1.7% of the measurement obtained using a duplex ultrasound system. The flow sensor and electronics operated continuously during the course of the 5-hour experiment after the incision on the animal was closed.


Assuntos
Artérias/diagnóstico por imagem , Artérias/fisiologia , Cuidados Pós-Operatórios/instrumentação , Próteses e Implantes , Refratometria/instrumentação , Transdutores , Ultrassonografia Doppler/instrumentação , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Módulo de Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Coelhos
4.
Artigo em Inglês | MEDLINE | ID: mdl-21156380

RESUMO

We have developed a dual-modality biomedical imaging probe utilizing intravascular ultrasound (IVUS) and optical coherence tomography (OCT). It consists of an OCT probe, a miniature ultrasonic transducer and a fixed mirror. The mirror was mounted at the head of the hybrid probe 45° relative to the light and the ultrasound beams to change their propagation directions. The probe was designed to be able to cover a larger area in blood vessel by IVUS and then visualize a specific point at a much finer image resolution using OCT. To demonstrate both its feasibility and potential clinical applications, we used this ultrasound-guide OCT probe to image a rabbit aorta in vitro. The results offer convincing evidence that the complementary natures of these two modalities may yield beneficial results that could not have otherwise been obtained.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia de Coerência Óptica/instrumentação , Ultrassonografia de Intervenção/instrumentação , Animais , Aorta/anatomia & histologia , Aorta/diagnóstico por imagem , Desenho de Equipamento , Imagens de Fantasmas , Coelhos , Processamento de Sinais Assistido por Computador , Tomografia de Coerência Óptica/métodos , Transdutores , Ultrassonografia de Intervenção/métodos
5.
J Biomed Opt ; 15(1): 010512, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20210424

RESUMO

We report on a dual-modality optical coherence tomography (OCT) ultrasound (US) system for intravascular imaging. To the best of our knowledge, we have developed the first integrated OCT-US probe that combines OCT optical components with an US transducer. The OCT optical components mainly consist of a single-mode fiber, a gradient index lens for light-beam focusing, and a right-angled prism for reflecting light into biological tissue. A 40-MHz piezoelectric transducer (PZT-5H) side-viewing US transducer was fabricated to obtain the US image. These components were integrated into a single probe, enabling both OCT and US imaging at the same time. In vitro OCT and ultrasound images of a rabbit aorta were obtained using this dual-modality imaging system. This study demonstrates the feasibility of an OCT-US system for intravascular imaging, which is expected to have a prominent impact on early detection and characterization of atherosclerosis.


Assuntos
Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/métodos , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos , Animais , Aorta/anatomia & histologia , Desenho de Equipamento , Coelhos
6.
Opt Lett ; 34(10): 1591-3, 2009 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-19448831

RESUMO

We have developed photoacoustic endoscopy with a miniaturized imaging probe. A light-guiding optical fiber, an ultrasonic sensor, and a mechanical scanning unit are integrated to enable circumferential sector scanning, which produces B-scan images. Biological tissues, including the gastrointestinal tract of a rat, have been imaged ex vivo or in situ.


Assuntos
Endoscopia/métodos , Fenômenos Ópticos , Abdome/cirurgia , Animais , Carbono , Fibra de Carbono , Fibras Ópticas , Ratos , Ultrassom