1.
Ultraschall Med ; 39(5): 526-534, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30176697

RESUMO

BACKGROUND: Breast lesions classified as BI-RADS-US 3 are probably benign and observation was recommended, while a considerable number of BI-RADS-US 4 lesions were benign, resulting in excessive biopsies. We focus exclusively on BI-RADS-US 3 and 4 lesions and hypothesize that improved diagnostic performance can be achieved by integrating real-time elastography (strain ratio) into the BI-RADS-US classification system. METHOD: From April 2010 to September 2015, 1071 lesions were included in the final analysis. After the conventional ultrasound examination, the BI-RADS-US (2013) classification was used to evaluate the lesions. Then the strain ratios were calculated, and the final diagnosis was made on the basis of histological results. The sensitivity, specificity, accuracy, PPV and NPV were calculated and the AUCs were compared. Additionally, an analysis of the diagnostic performance expressed by the pretest and posttest probability of disease (POD) was performed in BI-RADS-US 3 and 4A lesions. RESULTS: With the cutoff point of 2.98, the sensitivity, specificity and accuracy of the strain ratio method were 86.9 %, 86.6 % and 82.6 %, respectively. In BI-RADS-US 3 lesions, a suspicious strain ratio significantly modified the POD from 1.3 % to a posttest POD of 29.8 %. In BI-RADS-US 4A lesions, a suspicious strain ratio significantly modified the POD from 8.5 % to a posttest POD of 48.7 %. CONCLUSION: Ultrasonographic elastography (strain ratio) yields additional diagnostic information in the evaluation of BI-RADS-US 3 and 4 breast lesions. The strain ratios should be integrated into the BI-RADS-US classification system and into daily practice.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Neoplasias da Mama/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Sensibilidade e Especificidade , Ultrassonografia Mamária
2.
Ultrasound Med Biol ; 43(5): 903-910, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28256344

RESUMO

On the basis of results of our previous studies and the findings of other scholars, the most common histologic type of false-positive diagnosis with strain elastography (SE) was papilloma. The objectives of our study were to evaluate whether SE could contribute to conventional ultrasound differentiation between benign and malignant papillary lesions and between papillary lesions and other common benign breast lesions. Data on 89 papillary lesions at our hospital, including 74 benign and 15 malignant papillary lesions, were included in our study. In addition, 198 non-papillary benign tumors were selected as the control group, including 126 fibroadenomas and 72 cases of fibrocystic mastopathy. All patients gave written informed consent. All patients with breast lesions underwent conventional ultrasound and SE examination. Breast Imaging Recording and Data System (BI-RADS) category and SE score were compared with respect to sensitivity, specificity and accuracy in differentiating between benign and malignant papillary lesions. We then explored the possibility of using BI-RADS combined with SE to differentiate papillary lesions from non-papillary benign tumors. For differentiating between benign and malignant papillary lesions, the area under the receiver operating characteristic curve (AUC) of BI-RADS was 0.568, whereas the AUC values of SE score, strain ratio and BI-RADS combined with SE were 0.517, 0.584 and 0.509, respectively (p > 0.05). For differentiating between papillary lesions and non-papillary benign lesions, the AUC of BI-RADS combined with SE was 0.835, which was higher than the values for BI-RADS (0.775) and SE (SE score: 0.648, strain ratio: 0.661) (p < 0.001). The specificity and accuracy of BI-RADS combined with SE were significantly higher than those for BI-RADS alone without a decrease in sensitivity (p < 0.05). SE could not improve the diagnostic efficiency of BI-RADS in differentiating between benign and malignant papillary lesions. However, BI-RADS combined with SE could improve the specificity of BI-RADS without decrease in sensitivity for differentiating breast papillary lesions from non-papillary benign lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Papiloma/diagnóstico por imagem , Ultrassonografia Mamária/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
3.
PLoS One ; 11(2): e0148330, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26863208

RESUMO

BACKGROUND: This study aimed to confirm whether strain ratio should be added after evaluation of lesions with 5-point elasticity scoring for differentiating benign and malignant breast lesions on ultrasonographic elastography(UE). MATERIALS AND METHODS: From June 2010 to March 2012, 1080 consecutive female patients with breast lesions were recruited into a multicenter retrospective study, which involved 8 centers across China. Each institutional ethic review board approved the study, and all the patients gave written informed consent. All the patients underwent the UE procedure and the strain ratios were calculated and the final diagnosis was made by histological findings. The sensitivity, specificity, accuracy, PPV and NPV were calculated for each of the two evaluation systems and the areas under the ROC curve were compared. RESULTS: The strain ratios of benign lesions (mean, 2.6±2.0) and malignant lesions (mean,7.9±5.8) were significantly different (p <0.01). When the cutoff point was 3.01, strain ratio method had 79.8% sensitivity, 82.8% specificity, and 81.3% accuracy, while the 5-point scoring method had 93.1% sensitivity, 73.0% specificity, and 76.8% accuracy. The areas under the ROC curve with the strain ratio method and 5-point scoring method were 0.863 and 0.865, respectively(p>0.05). The strain ratio method shows better a diagnosis performance of the lesions with elasticity score 3 and 4. CONCLUSIONS: Although the two UE methods have similar diagnostic performance, separate calculation of the strain ratios seems compulsory, especially for the large solid breast lesions and the lesions with elasticity score 3 and 4.


Assuntos
Adenocarcinoma/diagnóstico , Neoplasias da Mama/diagnóstico , Carcinoma Ductal de Mama/diagnóstico , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Adenocarcinoma/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Elasticidade , Técnicas de Imagem por Elasticidade/instrumentação , Feminino , Humanos , Glândulas Mamárias Humanas/patologia , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Ultrassonografia Mamária/instrumentação
4.
Clin Breast Cancer ; 16(3): e33-41, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26639065

RESUMO

PURPOSE: To evaluate the additive diagnostic performance of ultrasound elastography (UE) to ultrasound (US) with the 2003 or 2013 Breast Imaging Reporting and Data System (BI-RADS)-US classification systems for the differentiation of benign and malignant breast lesions. METHODS: From June 2010 to December 2012, 738 women with 770 breast lesions were recruited into this retrospective study. Breast lesions were evaluated separately by US, UE, and both. US assessment was based on the 2003 or 2013 BI-RADS-US, and UE assessment was based on a previously reported 5-point scale. Diagnostic performance of US, UE, and both was compared. RESULTS: Before category 4 lesions were subdivided, the area under the receiver operating characteristic curve (AUC) for US, UE, and both were, respectively, 0.735, 0.877, 0.878 (P < .01). When subcategories of 4 lesions were considered, the AUC for US, UE, and both were, respectively, 0.865, 0.877, and 0.883 (P > .05). Adding UE to analysis of 4A lesions can decrease the percentages of malignancy to 2.56%. CONCLUSION: When the 2003 BI-RADS was considered, UE could give US some help in differentiating breast lesions. However, when the 2013 BI-RADS was considered, UE gave little help to US, although it reduced unnecessary biopsies of benign category 4A lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Feminino , Humanos , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem