Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Adv Sci (Weinh) ; 11(15): e2305530, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38353337

RESUMO

Considerable efforts have recently been made to augment the power density of moisture-enabled electric generators. However, due to the unsustainable ion/water molecule concentration gradients, the ion-directed transport gradually diminishes, which largely affects the operating lifetime and energy efficiency of generators. This work introduces an electrode chemistry regulation strategy into the ionic diode-type energy conversion structure, which demonstrates 1240 h power generation in ambient humidity. The electrode chemical regulation can be achieved by adding Cl-. The purpose is to destroy the passivation film on the electrode interface and provide a continuous path for ion-electron coupling conduction. Moreover, this device simultaneously satisfies the requirements of fast trapping of moisture molecules, high rectification ratio transport of ions, and sustained ion-to-electron current conversion. A single device can deliver an open-circuit voltage of about 1 V and a peak short-circuit current density of 350 µA cm-2. Finally, the first-principle calculations are carried out to reveal the mechanism by which the electrode surface chemistry affects the power generation performance.

2.
Mater Horiz ; 11(5): 1261-1271, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38164050

RESUMO

The ionic diode structure has become one of the attractive structures in the field of moisture-based power generation. However, existing devices still suffer from poor moisture trapping, low surface charge, and inefficient ion separation, resulting in low output power. Moreover, water freezes at low temperatures (<0 °C), limiting the ionic diode structure to generate electricity in cold environments. In this paper, a moisture-enabled power generator has been designed and fabricated, which assembles a negatively charged ionic hydrogel film and a positively charged anodized aluminum oxide (AAO) film to construct a heterojunction. The hydrogel polymer network is modified with a large number of sulfonate groups that dissociate to provide nanoscale pores with high surface charge to improve the rectification ratio. And the lithium chloride (LiCl) salt with high hydration ability is added to the hydrogel as a moisture-trapping and anti-freezing component. Usually salt ions reduce the Debye length, so that the ion transport is finally not controlled by the electric double layer (EDL) and the rectification fails. Interestingly, due to the natural affinity of the hydrogel polymer network for LiCl, LiCl is locked on the hydrogel side and does not easily enter the AAO pores to change the distribution of EDL within the nanochannel. As a result, the device rectification ratio is almost independent of the amount of LiCl addition, demonstrating an excellent balance of high output power and high freeze resistance. Ultimately, the device exhibits excellent power generation performance in the -20 °C to 60 °C temperature range and 15% to 93% RH humidity range. Typically, under high humidity (93% RH) at room temperature (25 °C), it provides an open-circuit voltage of 1.25 V and a short-circuit current of 300 µA cm-2, with an on-load output power of up to 71.35 µW cm-2. Under medium humidity (50% RH) at low temperature (-20 °C), it provides an open-circuit voltage of 1.11 V and a short-circuit current of 15 µA cm-2.

3.
Biosens Bioelectron ; 247: 115922, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38096720

RESUMO

Tactile sensors play an important role in human-machine interaction (HMI). Compared to contact tactile sensing, which leaves physical hardware vulnerable to wear and tear, proximity sensing is better at reacting to remote events before physical contact. The apteronotus albifrons possess ion channel receptors for remote surroundings perception. Inspired by the relevant ion channel structure and self-powered operation mode, we designed a new proximity sensor with ion rectification characteristics and self-powered capability. This bio-inspired ion channel receptor exploits the hygroelectric effect to convert the humidity information into a series of current signals when the living organism approaches, and it is insensitive to non-aquatic non-organisms. The sensor offers high sensitivity (2.3 mm-1), a suitable range (0-10 mm) for close object detection, fast response (0.3 s), and fast recovery (2.5 s). The unique combination of bio-sensitivity, non-contact detection characteristics, and humidity-based power generation capabilities enriches the functionality of future HMI electronics. As a proof of concept, the sensor has been successfully applied in different scenarios such as human health management, early warning systems, non-contact switches to prevent virus transmission, object recognition, and finger trajectory detection.


Assuntos
Técnicas Biossensoriais , Humanos , Tato/fisiologia , Eletrônica
4.
Micromachines (Basel) ; 14(12)2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38138331

RESUMO

In this work, high-frequency forced vibrations of lateral field excitation (LFE) devices with stepped electrodes based on monoclinic crystals GdCOB are modeled, and the influence laws of the device parameters (the step number, size, and thickness of the stepped electrodes) on the energy-trapping effects of the device are revealed. The results show that the step number has a significant effect on the energy-trapping effect of the device: with the increase in the step number, the stronger energy-trapping effect of the device can be obtained; with the increase in the thickness difference of two layers of electrodes, the energy-trapping effect of the device becomes stronger; with the increase in the difference of the electrode radius, the energy-trapping effect of the device is enhanced gradually. The results of this work can provide an important theoretical basis for the design of stepped-electrode LFE resonators and sensors with high-quality factors based on monoclinic crystals.

5.
Mater Horiz ; 10(11): 4940-4951, 2023 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-37609940

RESUMO

Building prosthetics indistinguishable from human limbs to accurately receive and transmit sensory information to users not only promises to radically improve the lives of amputees, but also shows potential in a range of robotic applications. Currently, a mainstream approach is to embed electrical or optical sensors with force/thermal sensing functions on the surface or inside of prosthetic fingers. Compared with electrical sensing technologies, tactile sensors based on stretchable optical waveguides have the advantages of easy fabrication, chemical safety, environmental stability, and compatibility with prosthetic structural materials. However, so far, research has mainly focused on the perception of finger joint motion or external press, and there is still a lack of study on optical sensors with fingertip tactile capabilities (such as texture, hardness, slip detection, etc.). Here we report a 3D printing prosthetic finger with flexible chromatic optical waveguides implanted at the fingertip. The finger achieves distributed displacement/force sensing detection, and exhibits high sensitivity, fast response and good stability. The finger can be used to conduct active sensory experiments, and the detection parameters include object contour, hardness, slip direction and speed, temperature, etc. Finally, exploratory research on identifying and manipulating objects is carried out with this finger. The developed prosthetic finger can artificially recreate touch perception and realize complex functions such as note-writing analysis and braille recognition.


Assuntos
Dedos , Percepção do Tato , Humanos , Dedos/fisiologia , Extremidade Superior , Tato/fisiologia , Fenômenos Mecânicos
6.
Talanta ; 265: 124855, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37406394

RESUMO

Influenza A epidemics, which occur annually in varying degrees worldwide, is a global challenge to healthcare facilities owing to several limitations of the current detection methods. Therefore, the development of a rapid, convenient, and economical method for the early diagnosis of influenza A will aid clinical treatment and epidemic control. Currently, most of the commonly used clinical rapid tests utilize colloidal gold test strips that detect specific influenza virus antigens but are limited by low sensitivity. Therefore, this study combined catalytic hairpin assembly (CHA) with colloidal gold immunochromatographic assay (GICA) to develop a highly sensitive and visual CHA-GICA test strip. Clinical sample analysis revealed that the sensitivity of the assay was 81.8% and 74% under optimal (35 °C) and room temperature (25 °C) conditions, respectively. In conclusion, this study developed a rapid nucleic acid assay for detecting influenza A virus with high sensitivity and specificity, which can improve the clinical detection of influenza A.

7.
Micromachines (Basel) ; 14(6)2023 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-37374721

RESUMO

The relaxor ferroelectric single crystal (1-x)Pb(Mg1/3Nb2/3)O3-xPbTiO3 (PMN-PT) has high piezoelectric constants, and thus has a good application prospect in the field of highly sensitive piezoelectric sensors. In this paper, for relaxor ferroelectric single crystal PMN-PT, the bulk acoustic wave characteristics on pure- and pseudo-lateral-field-excitation (pure- and pseudo-LFE) modes are investigated. LFE piezoelectric coupling coefficients and acoustic wave phase velocities for PMN-PT crystals in different cuts and electric field directions are calculated. On this basis, the optimal cuts of pure-LFE and pseudo-LFE modes of relaxor ferroelectric single crystal PMN-PT are obtained, namely, (zxt)45° and (zxtl)90°/90°, respectively. Finally, finite element simulations are carried out to verify the cuts of pure-LFE and pseudo-LFE modes. The simulation results show that the PMN-PT acoustic wave devices in pure-LFE mode have good energy-trapping effects. For PMN-PT acoustic wave devices in pseudo-LFE mode, when the device is in air, no obvious energy-trapping emerges; when the water (as a virtual electrode) is added to the surface of the crystal plate, an obvious resonance peak and the energy-trapping effect appears. Therefore, the PMN-PT pure-LFE device is suitable for gas-phase detections. While the PMN-PT pseudo-LFE device is suitable for liquid-phase detections. The above results verify the correctness of the cuts of the two modes. The research results provide an important basis for the development of highly sensitive LFE piezoelectric sensors based on relaxor ferroelectric single crystal PMN-PT.

8.
Int J Biol Macromol ; 245: 125475, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37353129

RESUMO

Breast cancer is a highly prevalent malignancy worldwide among women with an increasing incidence in recent years. Triple-negative breast cancer (TNBC), a specific type of breast cancer, occurs primarily in young women and exhibits large tumor size, high clinical stage, and extremely poor prognosis with a high rate of lymph node, liver, and lung metastases. TNBC is insensitive to endocrine therapy and trastuzumab treatment, and there is an urgent need for effective therapeutics and treatment guidelines. However, investigations into antiangiogenic agents for the treatment of TNBC are ongoing. In this study, we successfully engineered a self-assembled protein nanocarrier TfRBP9-hVEGI-192-ELP fusion protein (TVEFP) to deliver the therapeutic protein, human vascular endothelial growth inhibitor (hVEGI-192). This was found to be effective in inhibiting tumor angiogenesis in vivo. The protein nanocarrier effectively inhibited the progression of TNBC in vivo and showed the behavior of self-assembly, thermoresponsiveness, enzyme stimulation-responsiveness, tumor-targeting, biocompatibility, and biodegradability. Near-infrared imaging studies showed that fluorescent dye-stained TVEFP effectively aggregated at the tumor site. The TVEFP nanocarrier significantly expands the application of the therapeutic protein hVEGI-192 and improves the imaging and biotherapeutic effects in TNBC, chiefly based on anti-angiogenesis effects.


Assuntos
Neoplasias de Mama Triplo Negativas , Humanos , Feminino , Neoplasias de Mama Triplo Negativas/patologia , Linhagem Celular Tumoral , Receptores ErbB/metabolismo
9.
Medicine (Baltimore) ; 102(25): e34092, 2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37352076

RESUMO

BACKGROUND: This study aimed to compare the clinical efficacy and safety of microwave ablation (MWA) and radiofrequency ablation (RFA) for the treatment of spinal metastases. METHODS: A literature search was performed using the PubMed, Web of Science, and Cochrane Library databases according to the PRISMA statement (as of September 20, 2022). Two independent investigators screened articles based on the inclusion and exclusion criteria and included studies with primary outcomes of pain relief, tumor control, and complications. Article quality was assessed using the Risk Of Bias In Non-randomized Studies of Interventions tool. RESULTS: Sixteen articles were finally included in this study, including 630 patients with spinal metastases, with ages ranging from 51.4 to 71.3 years. Of these, 393 (62.4%) underwent MWA and 237 (37.6%) underwent RFA. After MWA and RFA treatment, visual analog scale scores significantly decreased, and the local tumor control rates were all above 80%. Complications were reported in 27.4% of patients treated with MWA compared with 10.9% of patients treated with RFA. CONCLUSION: The results of this systematic review suggest that MWA alone or in combination with surgery and RFA in combination with other modalities may improve pain caused by primary tumor metastasis to the spine, and MWA alone or in combination with surgery may have better local tumor control. However, MWA appears to result in more major complications than RFA in combination with other treatment modalities.


Assuntos
Ablação por Cateter , Neoplasias Hepáticas , Ablação por Radiofrequência , Neoplasias da Coluna Vertebral , Humanos , Micro-Ondas/uso terapêutico , Neoplasias da Coluna Vertebral/cirurgia , Ablação por Radiofrequência/métodos , Neoplasias Hepáticas/cirurgia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos Retrospectivos
10.
JMIR Res Protoc ; 12: e47160, 2023 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-37247211

RESUMO

BACKGROUND: Systematic reviews and meta-analyses based on observational studies have shown voluntary medical male circumcision (VMMC) may reduce HIV risk among men who have sex with men (MSM). There is a lack of randomized controlled trial (RCT) data assessing the efficacy of VMMC. OBJECTIVE: The primary objective of this study was to assess the efficacy of VMMC for preventing HIV acquisition among MSM who primarily engage in insertive anal sex. METHODS: A multicenter RCT will be conducted among MSM in 8 cities in China. Eligible participants are men aged 18-49 years who self-report ≥2 male sex partners in the past 6 months, predominantly practice insertive anal sex, and are willing to undergo circumcision. Interested men who satisfy inclusion criteria will be tested for HIV 1 month before enrollment and at enrollment, and only those who are HIV negative will be enrolled. At baseline, all enrolled participants will be asked to report sociodemographic characteristics and sexual behaviors; provide a blood sample for HIV, syphilis, and herpes simplex virus type 2 testing; and provide a penile swab for human papillomavirus testing. Participants will be randomly assigned to the intervention or control group. Those in the intervention group will receive VMMC and undergo a web-based weekly follow-up assessment of postsurgery healing for 6 consecutive weeks. All participants will be tested for HIV at 3-, 6-, 9-, and 12-month follow-ups. All participants will also be asked to report sexual behaviors and undergo repeat herpes simplex virus type 2 and human papillomavirus testing at 6- and 12-month follow-ups. The primary end point is HIV seroconversion. Secondary end points are the safety and satisfaction with VMMC and the changes in sexual behaviors after VMMC. The grouped censored data will be analyzed by intention-to-treat approach. RESULTS: Recruitment for the RCT began in August 2020 and continued through July 2022. Data collection is expected to be completed by July 2023, and full data analysis is going to be completed by September 2023. CONCLUSIONS: This study will be the first RCT to assess the efficacy of VMMC in preventing HIV infection among MSM. Results from this trial will provide preliminary evidence for the potential efficacy of VMMC to reduce incident HIV infection among MSM. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR2000039436; https://www.chictr.org.cn/showproj.html?proj=63369. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/47160.

11.
iScience ; 26(4): 106390, 2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37034995

RESUMO

Ever since the catalytic hairpin assembly (CHA) circuit has been highlighted as a powerful nucleic acid detection tool, nucleic acid detection methods based on CHA have been widely studied. However, the detection sensitivity of CHA-based methods is insufficient. The relatively high background signals resulting from the spontaneous reaction between the two hairpin probes is one of the major reasons for limiting the sensitivity of CHA. In this study, we established that the addition of deoxynucleotide triphosphates (dNTPs) to the reaction system can significantly reduce the background leakage of CHA. The dNTPs-CHA, coupled with a fluorescence lateral flow assay strip, is used for the rapid and highly sensitive detection of miRNA. It is capable of reliably detecting miRNA in serum samples down to a limit of 100 aM, which is an improvement in the lower detection limit by nearly five orders of magnitude compared to that of the pure CHA.

12.
PLoS One ; 18(3): e0268917, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36897913

RESUMO

The hybridization chain reaction (HCR) is widely used for biosensing. However, HCR does not provide the required sensitivity. In this study, we reported a method to improve the sensitivity of HCR by dampening the cascade amplification. First, we designed a biosensor based on HCR, and an initiator DNA was used to trigger the cascade amplification. Optimization of the reaction was then performed, and the results showed that the limit of detection (LOD) for the initiator DNA was about 2.5 nM. Second, we designed a series of inhibitory DNAs to dampen the HCR cascade amplification, and DNA dampeners (50 nM) were applied in the presence of the DNA initiator (50 nM). One of the DNA dampeners (D5) showed the best inhibitory efficiency of greater than 80%. This was further applied at concentrations ranging from 0 nM to 10 nM to prohibit the HCR amplification caused by a 2.5 nM initiator DNA (the limit of detection for this initiator DNA). The results showed that 0.156 nM of D5 could significantly inhibit the signal amplification (p<0.05). Additionally, the limit of detection for the dampener D5 was 16 times lower than that for the initiator DNA. Based on this detection method, we achieved a detection limit as low as 0.625 nM for HCV-RNAs. In summary, we developed a novel method with improved sensitivity to detect the target designed to prohibit the HCR cascade. Overall, this method could be used to qualitatively detect the presence of single-stranded DNA/RNA.


Assuntos
Técnicas Biossensoriais , Hepacivirus , Hepacivirus/genética , Hibridização de Ácido Nucleico/métodos , DNA/genética , RNA , Hibridização Genética , Técnicas Biossensoriais/métodos , Limite de Detecção
13.
Analyst ; 148(6): 1189-1208, 2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36825492

RESUMO

Nucleic acid testing for HIV plays an important role in the early diagnosis and monitoring of antiretroviral therapy outcomes in HIV patients and HIV-infected infants. Currently, the main molecular diagnostic methods employed are complex, time-consuming, and expensive to operate in resource-limited areas. Isothermal nucleic acid amplification technology overcomes some of the shortcomings of traditional assays and makes it possible to use point-of-care tests for molecular HIV detection. Here, we summarize and discuss the latest technological advances in isothermal nucleic acid amplification for HIV detection, with the intent of providing guidance for the development of subsequent HIV assays with high sensitivity and specificity.


Assuntos
Infecções por HIV , Ácidos Nucleicos , Humanos , Infecções por HIV/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Testes Imediatos , Técnicas de Diagnóstico Molecular , Sensibilidade e Especificidade
14.
Biomater Sci ; 11(5): 1754-1764, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36648428

RESUMO

Accurately identifying multidrug-resistant (MDR) bacteria from clinical samples has long been a challenge. Herein, we report a simple and programmable dual-mode aptasensor called DAPT to reliably detect MDR bacteria. The DAPT method comprises two elements, namely the mode of dynamic light scattering (Mode-DLS) for ultrasensitive detection and the mode of fluorescence (Mode-Flu) for reliable quantification as a potent complement. Benefiting from the states of aptamer-modified gold nanoparticles (AptGNPs) sensitively changing from dispersion to aggregation, the proposed Mode-DLS achieved the rapid, specific, and ultrasensitive detection of methicillin-resistant Staphylococcus aureus (MRSA) at the limit of detection (LOD) of 4.63 CFU mL-1 in a proof-of-concept experiment. Simultaneously, the Mode-Flu ensured the accuracy of the detection, especially at a high concentration of bacteria. Moreover, the feasibility and universality of the DAPT platform was validated with four other superbugs by simply reprogramming the corresponding sequence. Overall, the proposed DAPT method based on a dual-mode aptasensor can provide a universal platform for the rapid and ultrasensitive detection of pathogenic bacteria due to its superior programmability.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Nanopartículas Metálicas , Staphylococcus aureus Resistente à Meticilina , Ouro , Inibidores da Agregação Plaquetária , Limite de Detecção , Técnicas Biossensoriais/métodos
16.
Mol Cancer ; 22(1): 7, 2023 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-36627698

RESUMO

Gastric cancer (GC) is one of the most common tumors worldwide and the leading cause of tumor-related mortality. Endoscopy and serological tumor marker testing are currently the main methods of GC screening, and treatment relies on surgical resection or chemotherapy. However, traditional examination and treatment methods are more harmful to patients and less sensitive and accurate. A minimally invasive method to respond to GC early screening, prognosis monitoring, treatment efficacy, and drug resistance situations is urgently needed. As a result, liquid biopsy techniques have received much attention in the clinical application of GC. The non-invasive liquid biopsy technique requires fewer samples, is reproducible, and can guide individualized patient treatment by monitoring patients' molecular-level changes in real-time. In this review, we introduced the clinical applications of circulating tumor cells, circulating free DNA, circulating tumor DNA, non-coding RNAs, exosomes, and proteins, which are the primary markers in liquid biopsy technology in GC. We also discuss the current limitations and future trends of liquid biopsy technology as applied to early clinical biopsy technology.


Assuntos
Células Neoplásicas Circulantes , Neoplasias Gástricas , Humanos , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/genética , Biópsia Líquida/métodos , Biópsia/métodos , Prognóstico , Células Neoplásicas Circulantes/patologia , DNA de Neoplasias , Biomarcadores Tumorais
17.
ACS Omega ; 7(38): 33830-33836, 2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36188314

RESUMO

Ureaplasma urealyticum is a common genital mycoplasma in men and women, which can cause reproductive tract infection and infertility, and is also related to adverse pregnancy outcomes and neonatal diseases. Pathogen culture and polymerase chain reaction (PCR) are the main methods for the diagnosis of U. urealyticum. However, pathogen culture takes too long, and PCR requires professional personnel and sophisticated instruments. Here, we report a simple, convenient, sensitive, and specific detection method, which combines catalytic hairpin assembly with a lateral flow immunoassay strip. Only a water bath and a fluorescence reader are needed to detect the results in 30 min. We can realize the point-of-care testing of U. urealyticum by this method. To verify this method, we selected 10 clinical samples for testing, and the test results were exactly the same as the clinical report.

18.
Medicine (Baltimore) ; 101(42): e31099, 2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-36281182

RESUMO

BACKGROUND: Detecting circulating tumor cells (CTCs) has become a new strategy for predicting the prognosis of cancer patients. However, limited systematic research evidence is available for the detection of CTCs in various gastrointestinal tumors such as esophageal cancer (EC), colorectal cancer (CRC) and gastric cancer (GC). This topic was addressed to assess the prognostic significance of CTCs in gastrointestinal tumors. METHODS: We conducted a literature search according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist (from November 20, 2021). We performed a meta-analysis using the random effects model and Review Manager 5.3 software (The Cochrane Collaboration, Copenhagen, Denmark) according to the inclusion and exclusion criteria, data extraction and evaluation methods. RESULTS: Twenty-four articles met the inclusion criteria for this study, and they included 3803 EC, CRC and GC patients, including 1189 CTC-positive and 2462 CTC-negative cases. The meta-analysis showed that the presence of CTCs was associated with worse OS (HR = 2.05, 95% CI = 1.75-2.40, P = .060) and PFS (HR = 2.27, 95% CI = 1.79-2.89, P < .001). Further meta-regression and subgroup analyses showed that CTC-positive patients also showed worse OS and PFS in different subgroups. CONCLUSION: Our meta-analysis suggests that detecting CTCs in peripheral blood may be an important tool for improving the prognosis of patients with gastrointestinal tumors. Moreover, CTCs detection results could be used to develop personalized treatment plans in the future.


Assuntos
Neoplasias Esofágicas , Células Neoplásicas Circulantes , Neoplasias Gástricas , Humanos , Células Neoplásicas Circulantes/patologia , Prognóstico , Contagem de Células , Biomarcadores Tumorais
20.
Cell Immunol ; 372: 104472, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35093731

RESUMO

Immunotherapy has emerged as a promising treatment modality for HNSCC. However, only a small proportion of HNSCC patients experience clinical benefits from immunotherapy and identifying molecular markers that can serve as effective prognostic signatures and predictive indicators for immunotherapy response in patients with HNSCC is critical. CLEC10A has attracted attention because of its important role in improving the antitumor activity of immune cells. However, to our knowledge, no study has evaluated the role of CLEC10A in HNSCC prognosis, progression, and immune microenvironment. In the present study, we comprehensively analyzed expression profiles of CLEC10A and its association with tumor progression, HPV status, and survival of patients. Moreover, we explored the association between CLEC10A expression relative to immune infiltration and the response to immunotherapy. We explored the association between the timing of the receipt of palliative care relative to cancer diagnosis and survival. Our results revealed that CLEC10A has decreased expression in HNSCC compared with normal tissues, and that low expression of CLEC10A was associated with an advanced clinical stage and poor prognosis. Furthermore, a higher level of CLEC10A expression correlated with immune infiltration presence and response to immunotherapy in HNSCC. Thus, we demonstrated that CLEC10A could be a potential prognostic marker in patients with HNSCC, and a potential target for immunotherapy.


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias de Cabeça e Pescoço/imunologia , Neoplasias de Cabeça e Pescoço/metabolismo , Lectinas Tipo C/imunologia , Lectinas Tipo C/metabolismo , Carcinoma de Células Escamosas de Cabeça e Pescoço/imunologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/metabolismo , Biomarcadores Tumorais/genética , Biomarcadores Tumorais/imunologia , Regulação para Baixo , Regulação Neoplásica da Expressão Gênica , Neoplasias de Cabeça e Pescoço/genética , Humanos , Linfócitos do Interstício Tumoral/imunologia , Linfócitos do Interstício Tumoral/patologia , Mutação , Prognóstico , Carcinoma de Células Escamosas de Cabeça e Pescoço/genética , Microambiente Tumoral/genética , Microambiente Tumoral/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...