Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nurs Open ; 10(11): 7382-7393, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37694450

RESUMO

AIM: The present study aimed to develop an ethical behaviour rubric for nurses and evaluate its reliability and validity. METHOD: This study was to designed to construct a rubric and evaluate the reliability and validity. The ethical behaviour rubric was distributed to 241 nurses and 154 were completed and returned. The intra-rater and inter-rater reliability were evaluated by intraclass correlation coefficient (ICC) for all 10 items on the ethical behaviour rubric, and the internal consistency reliability was evaluated using Cronbach's α. Construct validity was tested with explanatory factor analysis, and criterion validity was tested using the known-groups method. RESULTS: Intra-rater reliability had a high interrater agreement (ICC = 0.9), and inter-rater reliability had a high interrater agreement (ICC = 0.84). The Cronbach's α coefficient was 0.96. There was a linear correlation between the number of years of nursing experience and rubric scores p < 0.001. Exploratory factor analysis revealed 10 items loading on four factors. The result of factor analysis is that Cronbach's α was 0.93 for the first factor, 0.83 for the second factor, 0.91 for the third factor, and 0.77 for the fourth factor. CONCLUSIONS: Our rubric was found to be a valid and reliable tool for the assessment of ethical behaviour among nurses in Japan.


Assuntos
Reprodutibilidade dos Testes , Humanos , Japão
2.
J Pharm Biomed Anal ; 223: 115127, 2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36327577

RESUMO

In this study, the imaging methods for evaluating the kinetics of nanoparticles as drug delivery systems in tumor tissues were improved in BxPC3 tumor-bearing mice. First, Förster resonance energy transfer (FRET) live imaging was selected to quantitatively evaluate nanoparticle kinetics in the tumor tissue of mice. Briefly, and 1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine iodide (as an acceptor)-and 1,1'-dioctadecyl-3,3,3',3'-tetramethylindodicarbocyanine, 4-chlorobenzenesulfonate salt (as a donor)-coloaded nanoparticles were administered intravenously to the mice, and imaging was performed using a fluorescence in vivo imager. The fluorescence intensities of images were acquired in the FRET, donor, and acceptor channels, and the nanoparticle kinetics in the tumor region was quantified by compensating for bleed-through. Second, in the cleared tumor tissue of mice, the difference in evaluation properties between the two- and three-dimensional visualization of the nanoparticles was examined. In brief, 1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate (DiI)-loaded nanoparticles were intravenously administered to the mice after fluorescently labeled tomato lectin treatment to visualize tumor vessels. Excised tumor tissue was cleared and observed using laser-scanning confocal microscopy, and three-dimensional images were reconstructed. The three-dimensional minimum distances traveled by DiI from the tumor vessels were calculated using information about the two-dimensional distance and the slicing position using the Pythagoras theorem. These imaging techniques should facilitate the development of drug delivery systems for cancer.


Assuntos
Nanopartículas , Neoplasias , Animais , Camundongos , Transferência Ressonante de Energia de Fluorescência/métodos , Cinética , Sistemas de Liberação de Medicamentos/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico
3.
Ann Thorac Surg ; 81(6): e24-6, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16731108

RESUMO

A 56-year-old woman was referred to our hospital for airway compromise. Relapsing polychondritis was diagnosed by bronchial cartilage biopsy. Bronchoscopy showed tracheobronchial malacia due to the disappearance of bronchial cartilage as a result of chondritis. Stent insertion using a Dynamic stent (Rüsch; Kernen, Germany), Ultraflex stent (Boston Scientific International, Colombes, France) and TM stent (Fuji Systems Corp, Tokyo, Japan) was repeated for more than 7 years. Dramatic improvement of dyspnea was obtained each time. The patient survived during this period without oxygen inhalation or mechanical ventilation before she suddenly died due to suffocation caused by difficulty of sputum discharge.


Assuntos
Obstrução das Vias Respiratórias/cirurgia , Broncopatias/cirurgia , Policondrite Recidivante/cirurgia , Implantação de Prótese , Stents , Doenças da Traqueia/terapia , Obstrução das Vias Respiratórias/etiologia , Asfixia/etiologia , Broncopatias/complicações , Broncoscopia , Morte Súbita , Dispneia/etiologia , Evolução Fatal , Feminino , Reação a Corpo Estranho/etiologia , Reação a Corpo Estranho/patologia , Tecido de Granulação/patologia , Humanos , Pessoa de Meia-Idade , Policondrite Recidivante/complicações , Recidiva , Escarro , Stents/efeitos adversos , Doenças da Traqueia/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...