Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 22(11): 1648-55, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10598969

RESUMO

Sudden cardiac death due to ventricular tachyarrhythmia remains a significant problem in the in-hospital setting. Although the probability of survival is closely correlated with the rapidity of a response by qualified personnel, response times can be prolonged, even in specialized care units. In an effort to decrease response time, a fully automatic external cardioverter defibrillator was recently devised. This device was evaluated in the in-hospital setting to assess safety and efficacy. A total of 79 patients were studied in a multicenter trial. Patients were monitored with fully functional devices in the electrophysiology laboratory (51 patients) and in the cardiac care unit (28 patients). Performance of the device was assessed by comparing automatic responses to any sustained change in cardiac rhythm, either spontaneous or induced, to a retrospective review of stored ECG data and programmed parameters. During a total duration of 964 hours of monitoring, there were 99 episodes of sustained tachycardia. Therapy was appropriately delivered or advised in all episodes. Therapy was advised in one episode of supraventricular tachycardia. There were no episodes of inappropriate therapy delivery. There were no complications or adverse events. The device performed with a sensitivity of 100% and specificity of 98.8% with an average response time of 22 seconds. In conclusion, this automatic external defibrillator was safe, effective, and functioned as designed. Significant improvement in response time to life-threatening ventricular tachyarrhythmia in the in-hospital setting would be expected if this technology was widely adopted.


Assuntos
Cardioversão Elétrica/instrumentação , Parada Cardíaca/terapia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Adulto , Unidades de Cuidados Coronarianos , Eletrocardiografia Ambulatorial/instrumentação , Eletrodos , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Parada Cardíaca/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador/instrumentação , Taquicardia Ventricular/etiologia , Resultado do Tratamento , Fibrilação Ventricular/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...