Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Medicina (Kaunas) ; 60(1)2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38256366

RESUMO

Background and Objectives: This study aimed to analyze patients with rhabdomyolysis who presented to emergency departments and identify their distribution of related disease and prognostic factors. Materials and Methods: A retrospective cohort study was conducted on patients with rhabdomyolysis who presented to emergency departments over a 10-year period. Patient data, including patients' demographic variables (sex and age), mode of arrival, final diagnosis, statin use, rhabdomyolysis trigger factors, and levels of serum creatine phosphokinase (CPK), myoglobin, creatinine, sodium, potassium, phosphate, calcium, and lactate, were analyzed. Univariate and multivariate logistic regression analyses were conducted to identify the predictive factors of acute kidney injury (AKI). Results: Among the patients, 268 (65.6%) were found to have trigger factors without underlying diseases. Furthermore, 115 (28.2%) patients developed AKI. This comprehensive study sheds light on the diverse factors influencing the occurrence of AKI in rhabdomyolysis and provides insights into AKI predictive markers. Furthermore, we analyzed the cases by dividing them into six groups: occurrence of AKI, occurrence of infection, and simple or complex rhabdomyolysis. CPK time course was found to be important in clinical prognosis, such as AKI occurrence, dialysis or not, and mortality. Conclusions: Age, statin use, elevated creatinine and lactate levels, and initial serum CPK level emerged as significant predictors of AKI. CPK time course was also found to be an important factor in predicting the clinical outcomes of patients with rhabdomyolysis.


Assuntos
Injúria Renal Aguda , Inibidores de Hidroximetilglutaril-CoA Redutases , Humanos , Creatinina , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Diálise Renal , Estudos Retrospectivos , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Serviço Hospitalar de Emergência , Prognóstico , Ácido Láctico
2.
Medicina (Kaunas) ; 59(1)2022 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-36676714

RESUMO

Background and Objectives: The ongoing coronavirus disease 2019 (COVID-19) pandemic represents a global public health crisis that has had a serious impact on emergency department (ED) utilization trends. The aim of this study was to investigate the collateral effects of the COVID-19 pandemic on ED utilization trends by patients with mild and severe conditions as well as on 7-day fatality rates. Materials and Methods: We analyzed entries in the Korean National Health Insurance claims database between 1 January 2018 and 31 December 2020. Six target patient groups were identified using the main diagnosis codes in the 10th revision of the International Classification of Diseases. Numbers of patients visiting the ED, their age, regional differences, 7-day fatality rate, and rate of emergency procedures were compared between 2018 and 2019 as the control period and 2020, when the COVID-19 pandemic was in full force. Results: During the 2020 COVID-19 pandemic, the number of patients who visited the ED with low-acuity diseases and severe acute respiratory infection diseases sharply decreased to −46.22% and −56.05%, respectively. However, the 7-day fatality rate after ED visits for low-acuity diseases and severe acute respiratory infection diseases increased to 0.04% (p < 0.01), and 1.65% (p < 0.01), respectively, in 2020 compared to that in the control period. Conclusions: During the 2020 COVID-19 pandemic, ED utilization impacted and 7-day fatality rate after ED visit increased. Health authorities and health care providers must strive to ensure prompt delivery of optimal care in EDs for patients with severe or serious symptoms and time-dependent diseases, even during the ongoing COVID-19 or potential future pandemics.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Pandemias , Serviço Hospitalar de Emergência , Doença Aguda , República da Coreia/epidemiologia , Estudos Retrospectivos
3.
Medicina (Kaunas) ; 57(11)2021 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-34833491

RESUMO

Background and Objectives: Due to the unexpected spread of coronavirus disease 2019 (COVID-19), there was a serious crisis of emergency medical system collapse. Healthcare workers working in the emergency department were faced with psychosocial stress and workload changes. Materials and Methods: This was a cross-sectional survey of healthcare workers in the emergency department in Daegu and Gyeongbuk, Korea, from November 16 to 25, 2020. In the survey, we assessed the general characteristics of the respondents; changes in the working conditions before and after the COVID-19 pandemic; and resulting post-traumatic stress disorder, depression and anxiety statuses using 49 questions. Results: A total of 529 responses were collected, and 520 responses were included for the final analyses. Changes in working conditions and other factors due to COVID-19 varied by emergency department level, region and disease group. Working hours, intensity, role changes, depression and anxiety scores were higher in the higher level emergency department. Isolation ward insufficiency and the risk of infection felt by healthcare workers tended to increase in the lower level emergency department. Treatment and transfer delay were higher in the fever and respiratory disease groups (M = 3.58, SD = 1.18; M = 4.08, SD = 0.95), respectively. In all the disease groups, both treatment and transfer were delayed more in Gyeongbuk than in Daegu. Conclusions: Different goals should be pursued by the levels and region of the emergency department to overcome the effects of the COVID-19 pandemic and promote optimal care.


Assuntos
COVID-19 , Serviços Médicos de Emergência , Ansiedade , Estudos Transversais , Depressão/epidemiologia , Surtos de Doenças , Serviço Hospitalar de Emergência , Pessoal de Saúde , Humanos , Pandemias , SARS-CoV-2 , Estresse Psicológico/epidemiologia , Carga de Trabalho
4.
J Appl Clin Med Phys ; 22(12): 115-124, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34783438

RESUMO

PURPOSE: To propose guidelines for lung stereotactic body radiation therapy (SBRT) when using Acuros XB (AXB) equivalent to the existing ones developed for convolution algorithms such as analytic anisotropic algorithm (AAA), considering the difference between the algorithms. METHODS: A retrospective analysis was performed on 30 lung patients previously treated with SBRT. The original AAA plans, which were developed using dynamic conformal arcs, were recalculated and then renormalized for planning target volume (PTV) coverage using AXB. The recalculated and renormalized plans were compared to the original plans based on V100% and V90% PTV coverage, as well as V105%, conformality index, D2cm , Rx/Dmax , R50, and Dmin . These metrics were analyzed nominally and on variations according to RTOG and NRG guidelines. Based on the relative difference between each metric in the AAA and AXB plans, new guidelines were developed. The relative differences in our cohort were compared to previously documented AAA to AXB comparisons found in the literature. RESULTS: AAA plans recalculated in AXB had a significant reduction in most dosimetric metrics. The most notable changes were in V100% (4%) and the conformality index (7.5%). To achieve equal PTV coverage, AXB required an average of 1.8% more monitor units (MU). This fits well with previously published data. Applying the new guidelines to the AXB plans significantly increased the number of minor violations with no change in major violations, making them comparable to those of the original AAA plans. CONCLUSION: The relative difference found between AAA and AXB for SBRT lung plans has been shown to be consistent with previous works. Based on these findings, new guidelines for lung SBRT are recommended when planning with AXB.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Radioterapia de Intensidade Modulada , Algoritmos , Humanos , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
5.
Medicina (Kaunas) ; 57(6)2021 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-34199537

RESUMO

Tetramine in gastropods can cause poisoning symptoms with various side effects. Most of these symptoms are mild and spontaneously resolved due to the rapid excretion of tetramine through the kidneys; however, patients with kidney dysfunction can present severe symptoms. A 48-year-old woman with end-stage kidney disease due to diabetic nephropathy and undergoing peritoneal dialysis (PD) visited our emergency department (ED) with complaints of general weakness, vomiting, and shortness of breath after ingesting some sea snails. On ED arrival, she was in a respiratory failure state; therefore, invasive mechanical ventilation was immediately initiated. Chest radiography showed diffuse severe pulmonary edema and her vital signs fluctuated; thus, continuous renal replacement therapy (CRRT) was initiated at the intensive care unit to treat tetramine intoxication and control volume status. Her condition gradually improved, and she was successfully weaned from mechanical ventilation on the 5th day of admission and moved to the general ward on the 10th day. CRRT was switched to PD. She fully recovered and was discharged on the 15th day of admission. Therefore, clinicians should explain the risk associated with gastropod ingestion to patients with kidney dysfunction and recognize that the clinical course of tetramine toxicity can be critical.


Assuntos
Diálise Peritoneal , Animais , Hidrocarbonetos Aromáticos com Pontes , Ingestão de Alimentos , Feminino , Humanos , Pessoa de Meia-Idade , Caramujos
6.
Phys Med Biol ; 65(5): 055001, 2020 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-31968326

RESUMO

The purpose of this study is to propose a reconstruction method of a target and its neighborhood, representative of the moment of radiotherapy delivery, based on differences in its transit images between the time of planning computed tomography (pCT) and the time of treatment beam delivery. To validate the method, a lung phantom with a target object was constructed, and CT-scanned before and after making a shift of the target. The latter scan was intended to simulate a potential organ movement at the time of treatment, and to serve as ground-truth images. Treatment planning using arc-beam delivery was done on the first pCT images. The planned beams were irradiated to the phantom after the shift, while cine transit images were acquired. Cine transit images were also calculated through the pCT images before the shift. From the ratio of the measured and calculated transit images, the amount of image changes due to the organ movement between the time of pCT and that of treatment was three-dimensionally reconstructed. By adding the reconstructed images to the pCT images before the shift, the CT images of the phantom at the time of the beam delivery were generated and compared with the ground truth images. The phantom after the shift was also scanned by on-board cone-beam computer tomography (CBCT) and reconstructed from the measured transit images (MVCT) for comparison. The proposed method reconstructed images that are very close to the ground-truth images in the volume and HU values of the target and the dose-volume coverage of the target and lung. Similar agreement was not found in the CBCT and MVCT images. The method may be used for 4D target image reconstruction, and, combined with the reconstructed image of un-irradiated areas, may offer clinically useful images of the entire region of interest.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Pulmonares/radioterapia , Movimento (Física) , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Humanos , Movimento , Imagens de Fantasmas
7.
Sensors (Basel) ; 19(1)2018 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-30585181

RESUMO

While the construction of high-rise buildings has become popular in big cities, an average of over 15,000 structure fires in those buildings are being reported in the United States. Especially because the fire in a building can result in a failure or even the collapse of the structure, assessing its integrity during and after the fire is of importance. Thus, in this paper, a framework with temperature sensors using wireless communication technology has been proposed. Associated hardware and software are carefully chosen and developed to provide an easy and effective solution for measuring fire load on large-scale structures during a fire. With an autonomous measurement system enabled, the key functions of the framework have been validated in a fire testing laboratory, using a real-scale steel column subject to standard fire. Unlike existing solutions of wireless temperature networks, the proposed solution can provide the user definable sampling frequencies based on the surface temperature and the means to assess the load redistribution of the structure due to fire loading in real-time. The results of the study show the great potential of using the developed framework for monitoring fire in a structure, allowing more accurate estimations of fire load in the design criteria, and advancing fire safety engineering.

8.
Med Phys ; 43(7): 4420, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27370157

RESUMO

PURPOSE: A method is proposed to reconstruct a four-dimensional (4D) dose distribution using phase matching of measured cine images to precalculated images of electronic portal imaging device (EPID). METHODS: (1) A phantom, designed to simulate a tumor in lung (a polystyrene block with a 3 cm diameter embedded in cork), was placed on a sinusoidally moving platform with an amplitude of 1 cm and a period of 4 s. Ten-phase 4D computed tomography (CT) images of the phantom were acquired. A planning target volume (PTV) was created by adding a margin of 1 cm around the internal target volume of the tumor. (2) Three beams were designed, which included a static beam, a theoretical dynamic beam, and a planning-optimized dynamic beam (PODB). While the theoretical beam was made by manually programming a simplistic sliding leaf motion, the planning-optimized beam was obtained from treatment planning. From the three beams, three-dimensional (3D) doses on the phantom were calculated; 4D dose was calculated by means of the ten phase images (integrated over phases afterward); serving as "reference" images, phase-specific EPID dose images under the lung phantom were also calculated for each of the ten phases. (3) Cine EPID images were acquired while the beams were irradiated to the moving phantom. (4) Each cine image was phase-matched to a phase-specific CT image at which common irradiation occurred by intercomparing the cine image with the reference images. (5) Each cine image was used to reconstruct dose in the phase-matched CT image, and the reconstructed doses were summed over all phases. (6) The summation was compared with forwardly calculated 4D and 3D dose distributions. Accounting for realistic situations, intratreatment breathing irregularity was simulated by assuming an amplitude of 0.5 cm for the phantom during a portion of breathing trace in which the phase matching could not be performed. Intertreatment breathing irregularity between the time of treatment and the time of planning CT was considered by utilizing the same reduced amplitude when the phantom was irradiated. To examine the phase matching in a humanoid environment, the matching was also performed in a digital phantom (4D XCAT phantom). RESULTS: For the static, the theoretical, and the planning-optimized dynamic beams, the 4D reconstructed doses showed agreement with the forwardly calculated 4D doses within the gamma pass rates of 92.7%, 100%, and 98.1%, respectively, at the isocenter plane given by 3%/3 mm criteria. Excellent agreement in dose volume histogram of PTV and lung-PTV was also found between the two 4D doses, while substantial differences were found between the 3D and the 4D doses. The significant breathing irregularities modeled in this study were found not to be noticeably affecting the reconstructed dose. The phase matching was performed equally well in a digital phantom. CONCLUSIONS: The method of retrospective phase determination of a moving object under irradiation provided successful 4D dose reconstruction. This method will provide accurate quality assurance and facilitate adaptive therapy when distinguishable objects such as well-defined tumors, diaphragm, and organs with markers (pancreas and liver) are covered by treatment beam apertures.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Tomografia Computadorizada Quadridimensional/instrumentação , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Modelos Anatômicos , Movimento (Física) , Imagens de Fantasmas , Poliestirenos , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador
9.
Med Phys ; 43(5): 2242, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27147336

RESUMO

PURPOSE: To develop and evaluate a fast Monte Carlo (MC) dose calculation model of electronic portal imaging device (EPID) based on its effective atomic number modeling in the XVMC code. METHODS: A previously developed EPID model, based on the XVMC code by density scaling of EPID structures, was modified by additionally considering effective atomic number (Zeff) of each structure and adopting a phase space file from the EGSnrc code. The model was tested under various homogeneous and heterogeneous phantoms and field sizes by comparing the calculations in the model with measurements in EPID. In order to better evaluate the model, the performance of the XVMC code was separately tested by comparing calculated dose to water with ion chamber (IC) array measurement in the plane of EPID. RESULTS: In the EPID plane, calculated dose to water by the code showed agreement with IC measurements within 1.8%. The difference was averaged across the in-field regions of the acquired profiles for all field sizes and phantoms. The maximum point difference was 2.8%, affected by proximity of the maximum points to penumbra and MC noise. The EPID model showed agreement with measured EPID images within 1.3%. The maximum point difference was 1.9%. The difference dropped from the higher value of the code by employing the calibration that is dependent on field sizes and thicknesses for the conversion of calculated images to measured images. Thanks to the Zeff correction, the EPID model showed a linear trend of the calibration factors unlike those of the density-only-scaled model. The phase space file from the EGSnrc code sharpened penumbra profiles significantly, improving agreement of calculated profiles with measured profiles. CONCLUSIONS: Demonstrating high accuracy, the EPID model with the associated calibration system may be used for in vivo dosimetry of radiation therapy. Through this study, a MC model of EPID has been developed, and their performance has been rigorously investigated for transit dosimetry.


Assuntos
Simulação por Computador , Método de Monte Carlo , Radiometria/instrumentação , Radiometria/métodos , Osso e Ossos/efeitos da radiação , Calibragem , Humanos , Pulmão/efeitos da radiação , Modelos Anatômicos , Imagens de Fantasmas , Água
10.
Radiat Oncol ; 10: 213, 2015 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-26499318

RESUMO

BACKGROUND: Exploiting biologic imaging, studies have been performed to boost dose to gross intraprostatic tumor volumes (GTV) while reducing dose elsewhere in the prostate. Interest in proton beams has increased due to superior normal-tissue sparing they afford. Our goal was to dosimetrically compare 3D conformal proton boost plans with intensity-modulated radiation therapy (IMRT) plans with respect to target coverage and avoiding organs at risk. METHODS: Treatment planning computer tomography scans of ten patients were selected. For each patient, two hypothetical but realistic GTVs each with a fixed volume were contoured in different anatomical locations of the prostate. IMRT and proton beam plans were created with a prescribed dose of 50.4 Gy to the initial planning target volume (PTV) including the PTV of the seminal vesicles (PSV), 70.2 Gy to the PTV of the prostate (PPS), and 90 Gy to the PTV of the gross tumor volumes (PGTVs). For proton plans, uncertainties of range and patient setup were accounted for; apertures were adjusted until the dose-volume coverage of PTVs matched that of the IMRT plan. For both plans, prescribed PTV doses were made identical to allow for comparing normal-tissue doses. RESULTS: Protons delivered more homogeneous but less conformal doses to PGTVs than IMRT did and comparable doses to PSV and PPS. Volumes of bladder and rectum receiving doses higher than 65 Gy were similar for both plans. However, volumes receiving less than 65 Gy were significantly reduced, i.e., protons reduced integral dose by 45.6 % and 26.5 % for rectum and bladder, respectively. This volume-sparing was also seen in femoral heads and penile bulb. CONCLUSIONS: Protons delivered comparable doses to targets in dose homogeneity and conformity and spared normal tissues from intermediate-to-low doses better than IMRT did. Further improvement of dose sparing and changes in homogeneity and conformity may be achieved by reducing proton range uncertainties and from implementing intensity modulation.


Assuntos
Neoplasias da Próstata/radioterapia , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Masculino , Dosagem Radioterapêutica
11.
J Appl Clin Med Phys ; 16(3): 5402, 2015 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-26103499

RESUMO

Radiographic film dosimetry suffers from its energy dependence in proton dosimetry. This study sought to develop a method of measuring proton beams by the film and to evaluate film response to proton beams for the constancy check of depth dose (DD). It also evaluated the film for profile measurements. To achieve this goal, from DDs measured by film and ion chamber (IC), calibration factors (ratios of dose measured by IC to film responses) as a function of depth in a phantom were obtained. These factors imply variable slopes (with proton energy and depth) of linear characteristic curves that relate film response to dose. We derived a calibration method that enables utilization of the factors for acquisition of dose from film density measured at later dates by adapting to a potentially altered processor condition. To test this model, the characteristic curve was obtained by using EDR2 film and in-phantom film dosimetry in parallel with a 149.65 MeV proton beam, using the method. An additional validation of the model was performed by concurrent film and IC measurement perpendicular to the beam at various depths. Beam profile measurements by the film were also evaluated at the center of beam modulation. In order to interpret and ascertain the film dosimetry, Monte Carlos simulation of the beam was performed, calculating the proton fluence spectrum along depths and off-axis distances. By multiplying respective stopping powers to the spectrum, doses to film and water were calculated. The ratio of film dose to water dose was evaluated. Results are as follows. The characteristic curve proved the assumed linearity. The measured DD approached that of IC, but near the end of the spread-out Bragg peak (SOBP), a spurious peak was observed due to the mismatch of distal edge between the calibration and measurement films. The width of SOBP and the proximal edge were both reproducible within a maximum of 5mm; the distal edge was reproducible within 1 mm. At 5 cm depth, the dose was reproducible within 10%. These large discrepancies were identified to have been contributed by film processor uncertainty across a layer of film and the misalignment of film edge to the frontal phantom surface. The deviations could drop from 5 to 2 mm in SOBP and from 10% to 4.5% at 5 cm depth in a well-controlled processor condition(i.e., warm up). In addition to the validation of the calibration method done by the DD measurements, the concurrent film and IC measurement independently validated the model by showing the constancy of depth-dependent calibration factors. For profile measurement, the film showed good agreement with ion chamber measurement. In agreement with the experimental findings, computationally obtained ratio of film dose to water dose assisted understanding of the trend of the film response by revealing relatively large and small variances of the response for DD and beam profile measurements, respectively. Conclusions are as follows. For proton beams, radiographic film proved to offer accurate beam profile measurements. The adaptive calibration method proposed in this study was validated. Using the method, film dosimetry could offer reasonably accurate DD constancy checks, when provided with a well-controlled processor condition. Although the processor warming up can promote a uniform processing across a single layer of the film, the processing remains as a challenge.


Assuntos
Algoritmos , Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Modelos Estatísticos , Radioterapia de Alta Energia/instrumentação , Radioterapia de Alta Energia/métodos , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Prótons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Med Phys ; 40(7): 072102, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23822446

RESUMO

PURPOSE: The continuous scanning mode of electronic portal imaging devices (EPID) that offers time-resolved information has been newly explored for verifying dynamic radiation deliveries. This study seeks to determine operating conditions (dose rate stability and time resolution) under which that mode can be used accurately for the time-resolved dosimetry of intensity-modulated radiation therapy (IMRT) beams. METHODS: The authors have designed the following test beams with variable beam holdoffs and dose rate regulations: a 10 × 10 cm open beam to serve as a reference beam; a sliding window (SW) beam utilizing the motion of a pair of multileaf collimator (MLC) leaves outside the 10 × 10 cm jaw; a step and shoot (SS) beam to move the pair in step; a volumetric modulated arc therapy (VMAT) beam. The beams were designed in such a way that they all produce the same open beam output of 10 × 10 cm. Time-resolved ion chamber measurements at isocenter and time-resolved and integrating EPID measurements were performed for all beams. The time-resolved EPID measurements were evaluated through comparison with the ion chamber and integrating EPID measurements, as the latter are accepted procedures. For two-dimensional, time-resolved evaluation, a VMAT beam with an infield MLC travel was designed. Time-resolved EPID measurements and Monte Carlo calculations of such EPID dose images for this beam were performed and intercompared. RESULTS: For IMRT beams (SW and SS), the authors found disagreement greater than 2%, caused by frame missing of the time-resolved mode. However, frame missing disappeared, yielding agreement better than 2%, when the dose rate of irradiation (and thus the frame acquisition rates) reached a stable and planned rate as the dose of irradiation was raised past certain thresholds (a minimum 12 s of irradiation per shoot used for SS IMRT). For VMAT, the authors found that dose rate does not affect the frame acquisition rate, thereby causing no frame missing. However, serious inplanar nonuniformities were found. This could be overcome by sacrificing temporal resolution (10 frames or 0.95 s/image): the continuous images agreed with ion chamber responses at the center of EPID and the calculation two-dimensionally in a time-resolved manner. CONCLUSIONS: The authors have determined conditions under which the continuous mode can be used for time-resolved dosimetry of fixed-gantry IMRT and VMAT and demonstrated it for VMAT.


Assuntos
Equipamentos e Provisões Elétricas , Radioterapia Guiada por Imagem/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Radiometria , Fatores de Tempo
13.
Med Phys ; 40(5): 051702, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23635250

RESUMO

PURPOSE: When an intensity-modulated radiation beam is delivered to a moving target, the interplay effect between dynamic beam delivery and the target motion due to miss-synchronization can cause unpredictable dose delivery. The portal dose image in electronic portal imaging device (EPID) represents radiation attenuated and scattered through target media. Thus, it may possess information about delivered radiation to the target. Using a continuous scan (cine) mode of EPID, which provides temporal dose images related to target and beam movements, the authors' goal is to perform four-dimensional (4D) dose reconstruction. METHODS: To evaluate this hypothesis, first, the authors have derived and subsequently validated a fast method of dose reconstruction based on virtual beamlet calculations of dose responses using a test intensity-modulated beam. This method was necessary for processing a large number of EPID images pertinent for four-dimensional reconstruction. Second, cine mode acquisition after summation over all images was validated through comparison with integration mode acquisition on EPID (IAS3 and aS1000) for the test beam. This was to confirm the agreement of the cine mode with the integrated mode, specifically for the test beam, which is an accepted mode of image acquisition for dosimetry with EPID. Third, in-phantom film and exit EPID dosimetry was performed on a moving platform using the same beam. Heterogeneous as well as homogeneous phantoms were used. The cine images were temporally sorted at 10% interval. The authors have performed dose reconstruction to the in-phantom plane from the sorted cine images using the above validated method of dose reconstruction. The reconstructed dose from each cine image was summed to compose a total reconstructed dose from the test beam delivery, and was compared with film measurements. RESULTS: The new method of dose reconstruction was validated showing greater than 95.3% pass rates of the gamma test with the criteria of dose difference of 3% and distance to agreement of 3 mm. The dose comparison of the reconstructed dose with the measured dose for the two phantoms showed pass rates higher than 96.4% given the same criteria. CONCLUSIONS: Feasibility of 4D dose reconstruction was successfully demonstrated in this study. The 4D dose reconstruction demonstrated in this study can be a promising dose validation method for radiation delivery on moving organs.


Assuntos
Equipamentos e Provisões Elétricas , Tomografia Computadorizada Quadridimensional/instrumentação , Doses de Radiação , Radioterapia Guiada por Imagem/instrumentação , Tomografia Computadorizada de Feixe Cônico , Estudos de Viabilidade , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
14.
Med Phys ; 39(12): 7593-602, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23231307

RESUMO

PURPOSE: Fast and accurate transit portal dosimetry was investigated by developing a density-scaled layer model of electronic portal imaging device (EPID) and applying it to a clinical environment. METHODS: The model was developed for fast Monte Carlo dose calculation. The model was validated through comparison with measurements of dose on EPID using first open beams of varying field sizes under a 20-cm-thick flat phantom. After this basic validation, the model was further tested by applying it to transit dosimetry and dose reconstruction that employed our predetermined dose-response-based algorithm developed earlier. The application employed clinical intensity-modulated beams irradiated on a Rando phantom. The clinical beams were obtained through planning on pelvic regions of the Rando phantom simulating prostate and large pelvis intensity modulated radiation therapy. To enhance agreement between calculations and measurements of dose near penumbral regions, convolution conversion of acquired EPID images was alternatively used. In addition, thickness-dependent image-to-dose calibration factors were generated through measurements of image and calculations of dose in EPID through flat phantoms of various thicknesses. The factors were used to convert acquired images in EPID into dose. RESULTS: For open beam measurements, the model showed agreement with measurements in dose difference better than 2% across open fields. For tests with a Rando phantom, the transit dosimetry measurements were compared with forwardly calculated doses in EPID showing gamma pass rates between 90.8% and 98.8% given 4.5 mm distance-to-agreement (DTA) and 3% dose difference (DD) for all individual beams tried in this study. The reconstructed dose in the phantom was compared with forwardly calculated doses showing pass rates between 93.3% and 100% in isocentric perpendicular planes to the beam direction given 3 mm DTA and 3% DD for all beams. On isocentric axial planes, the pass rates varied between 95.8% and 99.9% for all individual beams and they were 98.2% and 99.9% for the composite beams of the small and large pelvis cases, respectively. Three-dimensional gamma pass rates were 99.0% and 96.4% for the small and large pelvis cases, respectively. CONCLUSIONS: The layer model of EPID built for Monte Carlo calculations offered fast (less than 1 min) and accurate calculation for transit dosimety and dose reconstruction.


Assuntos
Modelos Estatísticos , Método de Monte Carlo , Radiometria/instrumentação , Radiometria/métodos , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/métodos , Ecrans Intensificadores para Raios X , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Dosagem Radioterapêutica
15.
J Appl Clin Med Phys ; 12(2): 3368, 2011 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-21587185

RESUMO

Almost 20 years ago, Emami et al. presented a comprehensive set of dose tolerance limits for normal tissue organs to therapeutic radiation, which has proven essential to the field of radiation oncology. The paradigm of stereotactic body radiotherapy (SBRT) has dramatically different dosing schemes but, to date, there has still been no comprehensive set of SBRT normal organ dose tolerance limits. As an initial step toward that goal, we performed an extensive review of the literature to compare dose limits utilized and reported in existing publications. The impact on dose tolerance limits of some key aspects of the methods and materials of the various authors is discussed. We have organized a table of 500 dose tolerance limits of normal structures for SBRT. We still observed several dose limits that are unknown or not validated. Data for SBRT dose tolerance limits are still preliminary and further clinical trials and validation are required. This manuscript presents an extensive collection of normal organ dose tolerance limits to facilitate both clinical application and further research.


Assuntos
Radiometria/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Encefálicas/radioterapia , Criança , Ensaios Clínicos como Assunto , Comorbidade , Relação Dose-Resposta à Radiação , Humanos , Tolerância a Radiação , Dosagem Radioterapêutica , Fatores de Tempo , Distribuição Tecidual
16.
J Appl Clin Med Phys ; 12(1): 3365, 2010 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-21330986

RESUMO

The Stereotactic Alignment for Linear Accelerator (S. A. Linac) system is developed to conveniently improve the alignment accuracy of a conventional linac equipped with stereotactic cones. From the Winston-Lutz test, the SAlinac system performs three-dimensional (3D) reconstruction of the quality assurance (QA) ball coordinates with respect to the radiation isocenter, and combines this information with digital images of the laser target to determine the absolute position of the room lasers. A handheld device provides near-real-time repositioning advice to enable the user to align the QA ball and room lasers to within 0.25 mm of the centroid of the radiation isocenter. The results of 37 Winston-Lutz tests over 68 days showed that the median 3D QA ball alignment error was 0.09 mm, and 97% of the time the 3D error was ≤ 0.25 mm. All 3D isocentric errors in the study were 0.3 mm or less. The median x and y laser alignment coordinate error was 0.09 mm, and 94% of the time the x and y laser error was ≤ 0.25 mm. A phantom test showed that the system can make submillimeter end-to-end accuracy achievable, making a conventional linac a "Submillimeter Knife".


Assuntos
Radiocirurgia/métodos , Técnicas Estereotáxicas , Humanos , Processamento de Imagem Assistida por Computador , Lasers , Controle de Qualidade , Radiocirurgia/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Phys Med Biol ; 54(17): 5223-36, 2009 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-19671973

RESUMO

A straightforward and accurate method was developed to verify the delivery of intensity-modulated radiation therapy (IMRT) and to reconstruct the dose in a patient. The method is based on a computational algorithm that linearly describes the physical relationship between beamlets and dose-scoring voxels in a patient and the dose image from an electronic portal imaging device (EPID). The relationship is expressed in the form of dose response functions (responses) that are quantified using Monte Carlo (MC) particle transport techniques. From the dose information measured by the EPID the received patient dose is reconstructed by inversely solving the algorithm. The unique and novel non-iterative feature of this algorithm sets it apart from many existing dose reconstruction methods in the literature. This study presents the algorithm in detail and validates it experimentally for open and IMRT fields. Responses were first calculated for each beamlet of the selected fields by MC simulation. In-phantom and exit film dosimetry were performed on a flat phantom. Using the calculated responses and the algorithm, the exit film dose was used to inversely reconstruct the in-phantom dose, which was then compared with the measured in-phantom dose. The dose comparison in the phantom for all irradiated fields showed a pass rate of higher than 90% dose points given the criteria of dose difference of 3% and distance to agreement of 3 mm.


Assuntos
Doses de Radiação , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/instrumentação , Reprodutibilidade dos Testes
18.
Brachytherapy ; 8(2): 240-247, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19230789

RESUMO

PURPOSE: To evaluate and report volumetric dose specification of clinical target volume (CTV) and organs at risk with three-dimensional CT-based brachytherapy. In this study, we analyzed CTV volumes and correlated the dose specification from CT-based volumes with doses at classical point A and International Commission on Radiation Units and Measurements (ICRU) points. METHODS AND MATERIALS: Ten patients who underwent definitive high-dose-rate brachytherapy for cervical cancer between May 2006 and March 2007 were retrospectively identified for this study. Each patient underwent five intracavitary insertions with CT-compatible ring and tandem applicators using a universal cervical Smit sleeve. Dose of 6.0Gy per fraction was prescribed to the 100% isodose line. The dose distribution was modified using the feature of "geometry optimization" to achieve maximum CTV coverage and to spare the organs at risk. The minimal doses for most irradiated 2, 1, 0.1cm(3) of bladder (D(BV2) , D(BV1), and D(BV0.1)) and rectum (D(RV2), D(RV1), and D(RV0.1)) were determined from dose-volume histograms and were compared with the doses estimated at the ICRU reference points. RESULTS: The mean CTV of the 10 patients had a shrinkage trend over the five fractions, with a mean of 77.4cm(3) from the first fractions and a mean of 65.5cm(3) from the last fractions (r=-0.911, p=0.031). CTV volumes directly correlated with dose to point A (r=0.785, p=0.007). Eight of 10 patients achieved an average dose received by at least 90% of volume (D(90)) >/=6.0Gy. For bladder, the doses determined from the 3-dimensional (3D) plan correlated significantly with the doses to the ICRU reference bladder point, for example, D(BV2) (r=0.668, p<0.001), D(BV1) (r=0.666, p<0.001), and D(BV0.1) (r=0.655, p<0.001). However, for rectum, the estimated doses to the ICRU reference rectal point did not correlate significantly with doses determined from 3D plan, for example, D(RV2) (r=0.251, p=0.079), D(RV1) (r=0.279, p=0.049), and D(BV0.1) (r=0.282, p=0.047). CONCLUSIONS: Our experience showed that excellent dose coverage of CTV can be achieved with image-guided CT-based planning with geometric optimization although maximal sparing of rectum was not achieved. Careful dose constraints and standardization of D(90) should be considered when optimizing doses to target tissues such that normal tissue constraints can be met.


Assuntos
Braquiterapia/métodos , Imageamento Tridimensional/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias do Colo do Útero/radioterapia , Adulto , Relação Dose-Resposta à Radiação , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Neoplasias do Colo do Útero/diagnóstico por imagem
19.
Radiat Oncol ; 1: 13, 2006 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-16722546

RESUMO

PURPOSE: To evaluate intensity-modulated radiation therapy (IMRT) as an alternative to conformal radiotherapy (CRT) or 4-field box boost (4FB) in women with gynecologic malignancies who are unsuitable for brachytherapy for technical or medical reasons. METHODS: Dosimetric and toxicity information was analyzed for 12 patients with cervical (8), endometrial (2) or vaginal (2) cancer previously treated with external beam pelvic radiotherapy and a CRT boost. Optimized IMRT boost treatment plans were then developed for each of the 12 patients and compared to CRT and 4FB plans. The plans were compared in terms of dose conformality and critical normal tissue avoidance. RESULTS: The median planning target volume (PTV) was 151 cm(3) (range 58-512 cm(3)). The median overlap of the contoured rectum with the PTV was 15 (1-56) %, and 11 (4-35) % for the bladder. Two of the 12 patients, both with large PTVs and large overlap of the contoured rectum and PTV, developed grade 3 rectal bleeding. The dose conformity was significantly improved with IMRT over CRT and 4FB (p < or = 0.001 for both). IMRT also yielded an overall improvement in the rectal and bladder dose-volume distributions relative to CRT and 4FB. The volume of rectum that received the highest doses (>66% of the prescription) was reduced by 22% (p < 0.001) with IMRT relative to 4FB, and the bladder volume was reduced by 19% (p < 0.001). This was at the expense of an increase in the volume of these organs receiving doses in the lowest range (<33%). CONCLUSION: These results indicate that IMRT can improve target coverage and reduce dose to critical structures in gynecologic patients receiving an external beam radiotherapy boost. This dosimetric advantage will be integrated with other patient and treatment-specific factors, particularly internal tumor movement during fractionated radiotherapy, in the context of a future image-guided radiation therapy study.


Assuntos
Neoplasias do Endométrio/radioterapia , Radiometria/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias do Colo do Útero/radioterapia , Neoplasias Vaginais/radioterapia , Fracionamento da Dose de Radiação , Feminino , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Resultado do Tratamento
20.
Med Phys ; 31(7): 1960-3, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15305446

RESUMO

Recently the EDR2 (extended dose range) film has been introduced commercially for applications in radiation therapy dosimetry. In addition to characterizing the wide dynamic range, several authors have reported a reduced energy dependence of this film compared to that of X-Omatic Verification (XV) films for megavoltage photon beams. However, those investigations were performed under limited geometrical conditions. We have investigated the dosimetric performance of EDR2 film for the verification of IMRT fields at more clinically relevant conditions by comparing the film doses with the doses measured with an ion chamber and XV films. The effects of using a low energy scattered photon filter on EDR2 film dosimetry was also studied. In contrast to previous reports our results show that EDR2 film still exhibits considerable energy dependence (a maximum discrepancy of 9%, compared with an ion chamber) at clinically relevant conditions (10 cm depth for IMRT fields). However, by using the low-energy filters the discrepancy is reduced to within 3%. Therefore, EDR2 film, in combination with the filters, is found to be a promising two-dimensional dosimeter for verification of IMRT treatment fields.


Assuntos
Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/métodos , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...