Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transl Vis Sci Technol ; 12(7): 15, 2023 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-37440248

RESUMO

Purpose: To investigate whether the trajectories of saccadic eye movements (SEMs) significantly differ between glaucoma patients and controls. Methods: SEMs were recorded by video-based infrared oculography in 53 patients with glaucoma and 41 age-matched controls. Participants were asked to bilaterally view 24°-horizontal, 14°-vertical, and 20°-diagonal eccentric Goldmann III-sized stimuli. SEMs were evaluated with respect to the saccadic reaction time (SRT), the mean velocity, amplitude, and two novel measures: departure angle (DA) and arrival angle (AA). These parameters were compared between the groups and the associations of SEM parameters with glaucoma parameters and integrated visual field defects were investigated. Results: Glaucoma patients exhibited increased mean SRT, DA, and AA values compared with controls for 14°-vertical visual targets (P = 0.05, P < 0.01, and P < 0.01, respectively). The SRT, DA, and AA were significantly associated with the mean and pattern standard deviations of perimetry and with the mean RNFL thickness by OCT (all P < 0.001). Glaucoma was associated with the AA (P = 0.05) and both the SRT (P = 0.01) and DA (P = 0.04) were associated with integrated visual field defects. Conclusions: The saccadic trajectories of glaucoma patients depart in an erroneous path and compensate the disparity by deviating the trajectory at arrival. Translational Relevance: The initial deviation that we observed (despite continuous exposure to the stimulus) suggests the disoriented spatial perception of glaucoma patients which may be relevant to difficulties encountered daily.


Assuntos
Glaucoma , Movimentos Sacádicos , Humanos , Campos Visuais , Glaucoma/diagnóstico , Testes de Campo Visual/métodos , Transtornos da Visão , Biometria
2.
Transl Vis Sci Technol ; 11(7): 24, 2022 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-35895054

RESUMO

Purpose: In acquiring images of the posterior eye, magnetic resonance imaging (MRI) provides low spatial resolution of the overall shape of the eye while optical coherence tomography (OCT) offers high spatial resolution of the limited range. Through the merger of the two devices, we attempted to acquire detailed anatomy of the posterior eye. Methods: Optical and display distortions in OCT images were corrected using the Listing reduced eye model. The 3.0T orbital MRI images were placed on the three-dimensional coordinate system of the computer-aided design (CAD) program. Employing anterior scleral canal opening, visual axis, and scleral curvature as references, original and corrected OCT images were ported into the CAD application. The radii of curvature of the choroid-scleral interfaces (Rc values) of all original and corrected OCT images were compared to the MRI images. Results: Sixty-five eyes of 33 participants (45.58 ± 19.82 years) with a mean Rc of 12.94 ± 1.24 mm on axial MRI and 13.66 ± 2.81 mm on sagittal MRI were included. The uncorrected horizontal OCT (30.51 ± 9.34 mm) and the uncorrected vertical OCT (34.35 ± 18.09 mm) lengths differed significantly from the MRI Rc values (both P < 0.001). However, the mean Rc values of the corrected horizontal (12.50 ± 1.21 mm) and vertical (13.05 ± 1.98 mm) images did not differ significantly from the Rc values of the corresponding MRI planes (P = 0.065 and P = 0.198, respectively). Conclusions: Features identifiable only on OCT and features only on MRI were successfully integrated into a unitary posterior eye. Translational Relevance: Our CAD-based converging method may establish the collective anatomy of the posterior eye and the neural canal, beyond the range of the OCT.


Assuntos
Imageamento Tridimensional , Tomografia de Coerência Óptica , Desenho Assistido por Computador , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Esclera , Tomografia de Coerência Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...