Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Nanobiotechnology ; 20(1): 6, 2022 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-34983543

RESUMO

BACKGROUND: Gold nanoparticles (AuNPs) have been widely used in local surface plasmon resonance (LSPR) immunoassays for biomolecule sensing, which is primarily based on two conventional methods: absorption spectra analysis and colorimetry. The low figure of merit (FoM) of the LSPR and high-concentration AuNP requirement restrict their limit of detection (LOD), which is approximately ng to µg mL-1 in antibody detection if there is no other signal or analyte amplification. Improvements in sensitivity have been slow in recent for a long time, and pushing the boundary of the current LOD is a great challenge of current LSPR immunoassays in biosensing. RESULTS: In this work, we developed spectral image contrast-based flow digital nanoplasmon-metry (Flow DiNM) to push the LOD boundary. Comparing the scattering image brightness of AuNPs in two neighboring wavelength bands near the LSPR peak, the peak shift signal is strongly amplified and quickly detected. Introducing digital analysis, the Flow DiNM provides an ultrahigh signal-to-noise ratio and has a lower sample volume requirement. Compared to the conventional analog LSPR immunoassay, Flow DiNM for anti-BSA detection in pure samples has an LOD as low as 1 pg mL-1 within only a 15-min detection time and 500 µL sample volume. Antibody assays against spike proteins of SARS-CoV-2 in artificial saliva that contained various proteins were also conducted to validate the detection of Flow DiNM in complicated samples. Flow DiNM shows significant discrimination in detection with an LOD of 10 pg mL-1 and a broad dynamic detection range of five orders of magnitude. CONCLUSION: Together with the quick readout time and simple operation, this work clearly demonstrated the high sensitivity and selectivity of the developed Flow DiNM in rapid antibody detection. Spectral image contrast and digital analysis further provide a new generation of LSPR immunoassay with AuNPs.


Assuntos
Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/isolamento & purificação , Ressonância de Plasmônio de Superfície/métodos , Anticorpos Antivirais/imunologia , COVID-19/imunologia , Teste Sorológico para COVID-19/instrumentação , Desenho de Equipamento , Ouro/química , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos , Nanopartículas Metálicas/química , SARS-CoV-2/imunologia , Saliva/virologia , Glicoproteína da Espícula de Coronavírus/imunologia , Ressonância de Plasmônio de Superfície/instrumentação
2.
Analyst ; 146(18): 5584-5591, 2021 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-34369484

RESUMO

COVID-19 has shown that a highly specific and rapid diagnostic system is a necessity. A spectral imaging-based surface plasmon resonance (SPRi) platform with an integrated microfluidic biosensor to detect oligonucleotide sequences has been proposed to be a promising alternative for infectious diseases due to its safe and straightforward use. Approaches to reduce the DNA probe loading onto gold nanoparticles with various types of polyethylene glycol (PEG) were explored. Here, we demonstrated the stability of functionalised gold nanoparticles with unmodified PEG whilst lowering the probe loading density. The system was evaluated by performing the detection of a mimicking COVID-19 target sequence, single point-mutation sequence and fully mismatch sequence. Highly specific binding of the mimicking COVID-19 target sequence was observed and analysed by the spectral imaging SPR approach. Our work has demonstrated the potential of a controlled probe density using unmodified PEG as an especially promising functionalisation strategy in SPR spectral imaging assays.


Assuntos
COVID-19 , Nanopartículas Metálicas , Ouro , Humanos , Limite de Detecção , SARS-CoV-2 , Ressonância de Plasmônio de Superfície
3.
Sci Rep ; 9(1): 8094, 2019 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-31147570

RESUMO

Adenocarcinoma, large cell carcinoma and squamous cell carcinoma are the most commonly diagnosed subtypes of non-small cell lung cancers (NSCLC). Numerous lung cancer cell types have exhibited electrotaxis under direct current electric fields (dcEF). Physiological electric fields (EF) play key roles in cancer cell migration. In this study, we investigated electrotaxis of NSCLC cells, including human large cell lung carcinoma NCI-H460 and human lung squamous cell carcinoma NCI-H520 cells. Non-cancerous MRC-5 lung fibroblasts were included as a control. After dcEF stimulation, NCI-H460 and NCI-H520 cells, which both exhibit epithelial-like morphology, migrated towards the cathode, while MRC-5 cells, which have fibroblast-like morphology, migrated towards the anode. The effect of doxycycline, a common antibiotic, on electrotaxis of MRC-5, NCI-H460 and NCI-H520 cells was examined. Doxycycline enhanced the tested cells' motility but inhibited electrotaxis in the NSCLC cells without inhibiting non-cancerous MRC-5 cells. Based on our finding, further in-vivo studies could be devised to investigate the metastasis inhibition effect of doxycycline in an organism level.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Movimento Celular/efeitos dos fármacos , Doxiciclina/farmacologia , Fenômenos Eletrofisiológicos , Neoplasias Pulmonares/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/patologia , Linhagem Celular Tumoral , Movimento Celular/fisiologia , Doxiciclina/uso terapêutico , Ensaios de Seleção de Medicamentos Antitumorais , Fibroblastos/efeitos dos fármacos , Humanos , Pulmão/citologia , Pulmão/patologia , Neoplasias Pulmonares/patologia , Testes de Toxicidade
4.
Analyst ; 143(19): 4715-4722, 2018 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-30188550

RESUMO

The clinical assessment of short-stranded nucleic acid biomarkers such as miRNAs could potentially provide useful information for monitoring disease progression, prompting definitive treatment decisions. In the past decade, advancements in biosensing technology have led to a shift towards rapid, real-time and label-free detection systems; as such, surface plasmon resonance (SPR) biosensor-based technology has become of high interest. Here, we developed an automated multiplex transmissive surface plasmon resonance (t-SPR) platform with the use of a capped gold nanoslit integrated microfluidic surface plasmon resonance (SPR) biosensor. The automated platform was custom designed to allow the analysis of spectral measurements using wavelength shift (dλ), intensity (dI) and novel area change (dA) for surface binding reactions. A simple and compact nanostructure based biosensor was fabricated with multiplex real-time detection capabilities. The sensitivity and specificity of the microfluidic device was demonstrated through the use of functionalised AuNPs for target molecule isolation and signal enhancement in combination with probes on the CG nanoslit surface. Our work allows for the multiplex detection of miRNA at femtomolar concentrations in complex media such as urine.


Assuntos
Técnicas Biossensoriais , MicroRNAs/urina , Ressonância de Plasmônio de Superfície , Biomarcadores/urina , Ouro , Humanos , Dispositivos Lab-On-A-Chip , Nanopartículas Metálicas
5.
J Biomed Mater Res B Appl Biomater ; 101(6): 939-49, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23529912

RESUMO

Plasma electrolytic oxidation (PEO) is a relatively new surface modification process that may be used as an alternative to plasma spraying methods to confer bioactivity to Ti alloy implants. The aim of this study was to compare physical, chemical and biological surface characteristics of two coatings applied by PEO processes, containing different calcium phosphate (CaP) and titanium dioxide phases, with a plasma-sprayed hydroxyapatite (HA) coating. Coating characteristics were examined by X-ray diffraction, energy dispersive X-ray spectroscopy, scanning electron microscopy, surface profilometry, and wettability tests. The biological properties were determined using the human osteoblastic cell line MG-63 to assess cell viability, calcium and collagen synthesis. The tests showed that PEO coatings are significantly more hydrophilic (6%) and have 78% lower surface roughness (Ra) than the plasma-sprayed coatings. Cell behavior was demonstrated to be strongly dependent on the phase composition and surface distribution of elements in the PEO coating. MG-63 viability for the TiO2 -based PEO coating containing amorphous CaPs was significantly lower than that for the PEO coating containing crystalline HA and the plasma-sprayed coating. However, collagen synthesis on both the CaP and the TiO2 PEO coatings was significantly higher (92% and 71%, respectively) than on the plasma-sprayed coating after 14 days. PEO has been demonstrated to be a promising method for coating of orthopedic implant surfaces.


Assuntos
Materiais Revestidos Biocompatíveis/química , Durapatita/química , Titânio/química , Ligas/química , Linhagem Celular , Sobrevivência Celular , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Osteoblastos/citologia , Próteses e Implantes , Espectrometria por Raios X , Propriedades de Superfície , Molhabilidade , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA