Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int Orthop ; 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38619563

RESUMO

PURPOSE: Pelvic support osteotomy (PSO) is regarded to provide pelvic stability and improve abductor function to delay or even avoid total hip arthroplasty (THA) in young patients with high-riding hip dysplasia. However, some of these patients eventually have to undergo THA. Because of the double-angulation deformity of the femur after PSO, subsequent THA is challenging. This study aimed to analyze whether PSO surgery is suitable for high-riding hip dysplasia and summarize orthopaedic strategy during THA for patients with previous PSO. METHODS: This case-control study included eight cases of THA for high-riding hip dysplasia patients with previous PSO (study group) and 24 cases of high-riding hip dysplasia patients without any hip surgical therapy (control group) by a 1:3 match (from May 2018 to January 2022). We compared demographics and joint function before and after THA between two groups and recorded all patients' preoperative imaging data, surgical procedures, postoperative imaging data, and complications. The surgical techniques for patients with previous PSO were highlighted. RESULTS: There was no statistical difference between the two groups in demographic (p > 0.05). The study group had worse hip Harris score (HHS), range of motion (ROM), visual analogue scale (VAS), and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) (p < 0.05) compared with the control group before THA. All patients had concurrent THA and osteotomy at the proximal femur, but the study group experienced longer operation time (p = 0.047) with more blood loss (p = 0.027) and higher complication rate compared with the control group (p = 0.009). At the last follow-up, the study group's HHS, ROM, VAS, and WOMAC were still worse than those in the control group. CONCLUSIONS: PSO did not improve the joint function of high-riding hip dysplasia patients but brought challenges to subsequent THA and affected the surgical outcomes. In short, we suggested that PSO is unsuitable for routine high-riding hip dysplasia patients.

2.
J Orthop Surg Res ; 19(1): 176, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38459538

RESUMO

BACKGROUND: Accurate preoperative planning is crucial for successful total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH). The aim of this study was to compare the accuracy of an artificial intelligence-assisted three-dimensional (3D) planning system (AIHIP) with two-dimensional templates in predicting acetabular cup size in THA for DDH. METHOD: This study retrospectively analyzed image data from 103 DDH patients who had THA between May 2019 and August 2023. AIHIP was used for 3D planning, and two-dimensional (2D) templates were used by two experienced surgeons. Accuracy was assessed by comparing predicted and actual cup sizes, and potential factors affecting accuracy were analyzed, including gender, side, BMI, and dysplasia classification. RESULTS: AIHIP had higher accuracy in predicting the acetabular cup size compared to the 2D template. Within ± 0 size, AIHIP's accuracy was 84.1%, while the 2D template's was 64.0% (p < 0.05). Within ± 1 size, AIHIP's accuracy was 95.1%, while the 2D template's was 81.1% (p < 0.05). Accuracy was unaffected by gender, side, or BMI but was by DDH classification. In subgroup analysis, AIHIP's mean absolute error (0.21 ± 0.54) was significantly lower than the 2D template's (0.62 ± 0.95) for Crowe II and Crowe III (p < 0.05). CONCLUSION: AIHIP is superior to 2D templates in predicting the acetabular cup size accurately for THA in DDH patients. AIHIP may be especially beneficial for Crowe II and III DDH patients, as 2D templates may not accurately predict cup size in these cases.


Assuntos
Artroplastia de Quadril , Displasia do Desenvolvimento do Quadril , Luxação Congênita de Quadril , Prótese de Quadril , Humanos , Inteligência Artificial , Estudos Retrospectivos , Displasia do Desenvolvimento do Quadril/cirurgia , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/cirurgia , Software
3.
Front Bioeng Biotechnol ; 10: 1053399, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36440438

RESUMO

Prosthetic joint infection (PJI) is often considered as one of the most common but catastrophic complications after artificial joint replacement, which can lead to surgical failure, revision, amputation and even death. It has become a worldwide problem and brings great challenges to public health systems. A small amount of microbe attaches to the graft and forms a biofilm on its surface, which lead to the PJI. The current standard methods of treating PJI have limitations, but according to recent reports, bioactive materials have potential research value as a bioactive substance that can have a wide range of applications in the field of PJI. These include the addition of bioactive materials to bone cement, the use of antibacterial and anti-fouling materials for prosthetic coatings, the use of active materials such as bioactive glasses, protamine, hydrogels for prophylaxis and detection with PH sensors and fluorescent-labelled nanoparticles, and the use of antibiotic hydrogels and targeting delivery vehicles for therapeutic purposes. This review focus on prevention, detection and treatment in joint infections with bioactive materials and provide thoughts and ideas for their future applications.

4.
Front Bioeng Biotechnol ; 10: 1012653, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36267457

RESUMO

Human joints move thousands of times a day. The articular cartilage plays a vital role in joints' protection. If there is dysfunction in cartilage lubrication, cartilage cannot maintain its normal function. Eventually, the dysfunction may bring about osteoarthritis (OA). Extensive researches have shown that fluid film lubrication, boundary lubrication, and hydration lubrication are three discovered lubrication models at cartilage surface, and analyzing and simulating the mechanism of cartilage lubrication are fundamental to the treatment of OA. This essay concludes recent researches on the progress of cartilage lubrication and biomimetic cartilage, revealing the pathophysiology of cartilage lubrication and updating bio-inspired cartilage lubrication applications.

5.
Front Bioeng Biotechnol ; 10: 1014543, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36312537

RESUMO

Rheumatoid Arthritis is a universal disease that severely affects the normal function of human joints and the quality of life. Millions of people around the world are diagnosed with rheumatoid arthritis every year, carrying a substantial burden for both the individual and society. Hydrogel is a polymer material with good mechanical properties and biocompatibility, which shows great potential in the treatment of rheumatoid arthritis. With the progress of tissue engineering and biomedical material technology in recent years, more and more studies focus on the application of hydrogels in rheumatoid arthritis. We reviewed the progress of hydrogels applied in rheumatoid arthritis in recent years. Also, the needed comprehensive performance and current applications of therapeutic hydrogels based on the complex pathophysiological characteristics of rheumatoid arthritis are also concluded. Additionally, we proposed the challenges and difficulties in the application of hydrogels in rheumatoid arthritis and put forward some prospects for the future research.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...