Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 399
Filtrar
1.
Angew Chem Int Ed Engl ; 63(23): e202403585, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38565432

RESUMO

In spite of the competitive performance at room temperature, the development of sodium-ion batteries (SIBs) is still hindered by sluggish electrochemical reaction kinetics and unstable electrode/electrolyte interphase under subzero environments. Herein, a low-concentration electrolyte, consisting of 0.5M NaPF6 dissolving in diethylene glycol dimethyl ether solvent, is proposed for SIBs working at low temperature. Such an electrolyte generates a thin, amorphous, and homogeneous cathode/electrolyte interphase at low temperature. The interphase is monolithic and rich in organic components, reducing the limitation of Na+ migration through inorganic crystals, thereby facilitating the interfacial Na+ dynamics at low temperature. Furthermore, it effectively blocks the unfavorable side reactions between active materials and electrolytes, improving the structural stability. Consequently, Na0.7Li0.03Mg0.03Ni0.27Mn0.6Ti0.07O2//Na and hard carbon//Na cells deliver a high capacity retention of 90.8 % after 900 cycles at 1C, a capacity over 310 mAh g-1 under -30 °C, respectively, showing long-term cycling stability and great rate capability at low temperature.

2.
RSC Adv ; 13(39): 27054-27065, 2023 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-37693085

RESUMO

The catalytic conversion of biomass-derived glycerol into high-value-added products, such as glyceric acid (GLYA), using catalyst-supported Au nanoparticles (Au NPs) at room temperature presents a significant challenge. In this study, we constructed a series of supported Au catalysts, including Au/ZrO2@C, Au/C, Au/ZrO2, and Au/ZrO2-C, and investigated their effectiveness in selectively catalytic oxidizing glycerol to GLYA at room temperature. Among these catalysts, the Au/ZrO2@C catalyst exhibited the best catalytic performance, achieving a glycerol conversion rate of 73% and a GLYA selectivity of 79% under the optimized reaction conditions (reaction conditions: 30 mL 0.1 M glycerol, glycerol/Au = 750 mol mol-1, T = 25 °C, p(O2) = 10 bar, stirring speed = 600 rpm, time = 6 h). Physical adsorption, X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), and other characterization methods were employed to analyze the texture properties of the catalyst. The findings indicated that the support structure, the strong metal-support interactions between Au NPs and the support, and the presence of small metallic Au NPs were the primary factors contributing to the catalyst's high activity and selectivity. Moreover, the reusability of the Au/ZrO2@C catalyst was investigated, and a probable reaction mechanism for the oxidation of glycerol was proposed.

3.
ACS Appl Mater Interfaces ; 15(19): 23236-23245, 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37150942

RESUMO

O3-type layered oxides with high initial sodium content are promising cathode candidates for Na-ion batteries. However, affected by the undesired transition metal slab sliding and reaction with H2O/CO2, their further application is typically hindered by unsatisfactory cycling stability upon charging to high voltage and poor storage stability under humid air. Herein, we demonstrate a Fe/Ti cosubstitution strategy to simultaneously enhance the electrochemical performance and storage stability of pristine O3-NaNi0.5Mn0.5O2 cathode material, via employing high redox potential and inactive stabilized dopants. The resultant Fe/Ti cosubstituted Na0.95Ni0.40Fe0.15Mn0.3Ti0.15O2 undergoes highly reversible O3-P3-OP2 phase transitions with a small cell volume change of 2.8%, instead of complex O3-O'3-P3-P'3-P3'-O1 phase transitions in NaNi0.5Mn0.5O2. Consequently, the cathode displays a high specific capacity of 161.6 mAh g-1 with an average working voltage of 3.28 V and 81.8% capacity retention after 200 cycles at 5C. Furthermore, the cathode material remains very stable after exposure to air for 7 days and even after soaking in water for 1 h, owing to the prohibition of sodium losing by elevating redox potential and contracting sodium layer spacing. This work proposes an effective method to enhance the electrochemical performance and storage stability of O3-type layered oxide cathodes and promises advancing Na-ion batteries toward large-scale industrialization.

5.
ACS Biomater Sci Eng ; 9(3): 1672-1681, 2023 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-36796355

RESUMO

Osteoarthritis (OA) is an inflammatory disease accompanied by synovial joint inflammation, and IL-36 plays an important role in this process. Local application of IL-36 receptor antagonist (IL-36Ra) can effectively control the inflammatory response, thereby protecting cartilage and slowing down the development of OA. However, its application is limited by the fact that it is rapidly metabolized locally. We designed and prepared a temperature-sensitive poly(lactic-co-glycolic acid)-poly(ethylene glycol)-poly(lactic-co-glycolic acid) (PLGA-PEG-PLGA) hydrogel (IL-36Ra@Gel) system carrying IL-36Ra and evaluated its basic physicochemical characteristics. The drug release curve of IL-36Ra@Gel indicated that this system could slowly release the drug over a longer period. Furthermore, degradation experiments showed that it could be largely degraded from the body within 1 month. The biocompatibility-related results showed that it had no significant effect on cell proliferation compared to the control group. In addition, the expression of MMP-13 and ADAMTS-5 was lower in IL-36Ra@Gel-treated chondrocytes than in the control group, and the opposite results appeared in aggrecan and collagen X. After 8 weeks of treatment with IL-36Ra@Gel by joint cavity injection, HE and Safranin O/Fast green staining showed that the degree of cartilage tissue destruction in the IL-36Ra@Gel-treated group was less than those in other groups. Meanwhile, the joints of mice in the IL-36Ra@Gel group had the most intact cartilage surface, the smallest thickness of cartilage erosion, and the lowest OARSI and Mankins score among all groups. Consequently, the combination of IL-36Ra and PLGA-PLEG-PLGA temperature-sensitive hydrogels can greatly improve the therapeutic effect and prolong the drug duration time, thus effectively delaying the progression of degenerative changes in OA, providing a new feasible nonsurgical treatment for OA.


Assuntos
Hidrogéis , Osteoartrite , Camundongos , Animais , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/metabolismo , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/farmacologia , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/uso terapêutico , Hidrogéis/metabolismo , Temperatura , Osteoartrite/tratamento farmacológico , Osteoartrite/metabolismo , Condrócitos/metabolismo
6.
IEEE Trans Neural Netw Learn Syst ; 34(4): 2133-2143, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34473629

RESUMO

There has been a recent surge of success in optimizing deep reinforcement learning (DRL) models with neural evolutionary algorithms. This type of method is inspired by biological evolution and uses different genetic operations to evolve neural networks. Previous neural evolutionary algorithms mainly focused on single-objective optimization problems (SOPs). In this article, we present an end-to-end multi-objective neural evolutionary algorithm based on decomposition and dominance (MONEADD) for combinatorial optimization problems. The proposed MONEADD is an end-to-end algorithm that utilizes genetic operations and rewards signals to evolve neural networks for different combinatorial optimization problems without further engineering. To accelerate convergence, a set of nondominated neural networks is maintained based on the notion of dominance and decomposition in each generation. In inference time, the trained model can be directly utilized to solve similar problems efficiently, while the conventional heuristic methods need to learn from scratch for every given test problem. To further enhance the model performance in inference time, three multi-objective search strategies are introduced in this work. Our experimental results clearly show that the proposed MONEADD has a competitive and robust performance on a bi-objective of the classic travel salesman problem (TSP), as well as Knapsack problem up to 200 instances. We also empirically show that the designed MONEADD has good scalability when distributed on multiple graphics processing units (GPUs).

7.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-1010282

RESUMO

OBJECTIVE@#To summarize and identify the available instruments/methods assessing the adequacy of acupuncture in randomized controlled trials (RCTs) for proposing a new improved instrument.@*METHODS@#A systematic literature search was carried out in 7 electronic databases from inception until 21st November 2022. Any study evaluating the adequacy or quality of acupuncture, specifying specific acupuncture treatment-related factors as criteria of subgroup analysis, or developing an instrument/tool to assess the adequacy or quality of acupuncture in an RCT was included. Basic information, characteristics and contents of acupuncture adequacy assessment were presented as frequencies and percentages.@*RESULTS@#Forty studies were included in this systematic review. Thirty-five studies (87.50%) were systematic reviews, none of which used formal methods to develop the assessment instruments/methods of acupuncture adequacy; of 5 methodological studies, only 1 study used a relatively formal method. Thirty-two studies (82.05%) assessed the components of acupuncture, while 7 (17.95%) assessed the overall quality of acupuncture. An independent assessment instrument/method was used to assess acupuncture adequacy in 29 studies (74.35%), whereas as one part of a methodological quality assessment scale in 10 (25.65%). Only 9 (23.00%) studies used the assessment results for subgroup analysis, sensitivity analysis or the criteria for inclusion in the meta-analysis.@*CONCLUSION@#Assessment contents for adequacy or quality of acupuncture in RCTs hadn't still reached consensus and no widely used assessment tools appeared. The methodology of available assessment instruments/scales is far from formal and rigorous. A new instrument/tool assessing adequacy of acupuncture should be developed using a formal method.


Assuntos
Terapia por Acupuntura/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto
8.
Journal of Geriatric Cardiology ; (12): 855-866, 2023.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-1010214

RESUMO

BACKGROUND@#It is not clear whether sacubitril/valsartan is beneficial for patients with heart failure (HF) with reduced ejection fraction (HFrEF) and low systolic blood pressure (SBP). This study aimed to investigate the efficacy and tolerability of sacubitril/valsartan in HFrEF patients with SBP < 100 mmHg.@*METHODS & RESULTS@#An observational study was conducted on 117 patients, 40.2% of whom had SBP < 100 mmHg without symptomatic hypotension, and 59.8% of whom had SBP ≥ 100 mmHg in an optimized HF follow-up management system. At the 6-month follow-up, 52.4% of patients with SBP < 100 mmHg and 70.0% of those with SBP ≥ 100 mmHg successfully reached the target dosages of sacubitril/valsartan. A reduction in the concentration of N-terminal pro-B-type natriuretic peptide was similar between patients with SBP < 100 mmHg and SBP ≥ 100 mmHg (1627.5 pg/mL and 1340.1 pg/mL, respectively; P = 0.75). The effect of sacubitril/valsartan on left ventricular ejection fraction was observed in both SBP categories, with a 10.8% increase in patients with SBP < 100 mmHg (P < 0.001) and a 14.0% increase in patients with SBP ≥ 100 mmHg (P < 0.001). The effects of sacubitril/valsartan on SBP were statistically significant and inverse across both SBP categories (P = 0.001), with an increase of 7.5 mmHg in patients with SBP < 100 mmHg and a decrease of 11.5 mmHg in patients with SBP ≥ 100 mmHg. No statistically significant differences were observed between the two groups in terms of the occurrence of symptomatic hypotension, deteriorating renal function, hyperkalemia, angioedema, or stroke.@*CONCLUSIONS@#Within an optimized HF follow-up management system, sacubitril/valsartan exhibited excellent tolerability and prompted left ventricular reverse remodeling in patients with HFrEF who presented asymptomatic hypotension.

9.
Chinese Journal of Lung Cancer ; (12): 692-700, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1010076

RESUMO

With the development of medical technology, tumor vaccines as a novel precise immunotherapy approach have gradually received attention in clinical applications. Against the backdrop of the global corona virus disease 2019 (COVID-19) outbreak, vaccine technology has further advanced. Depending on the types of antigens, tumor vaccines can be divided into whole-cell vaccines, peptide vaccines, messenger ribonucleic acid (mRNA) vaccines, recombinant virus vaccines, etc. Although some tumor vaccines have been marketed and achieved certain therapeutic effects, the results of tumor vaccines in clinical trials have been unsatisfactory in the past period. With the maturation of next-generation sequencing (NGS) technology and the continuous development of bioinformatics, dynamic monitoring of the entire process of tumor subpopulation development has become a reality, which has laid a solid foundation for personalized, neoantigen-centered therapeutic tumor vaccines. This article reviews the recent developments of tumor vaccines of different types, starts with lung cancer and summarizes the achievements of tumor vaccines in clinical applications, and provides an outlook for the future development of antigen-centered tumor vaccines.
.


Assuntos
Humanos , Vacinas Anticâncer/uso terapêutico , Antígenos de Neoplasias , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias/genética , Biologia Computacional , Imunoterapia/métodos , Pulmão
10.
Chinese Journal of Pediatrics ; (12): 61-65, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-970237

RESUMO

Objective: To investigate the clinical characteristics of children with allergic diseases suffering from SARS-CoV-2 Omicron variant strains. Methods: This was a cross-sectional study. A total of 43 pediatric patients with allergic diseases infected by SARS-CoV-2 from April 25, 2022 to June 8, 2022 in Shanghai Jiao Tong University School of Medicine were selected as the allergic disease group, while 114 cases without underlying diseases and 16 cases with other underlying diseases were selected as control groups diagnosed at the same period. Clinical data including clinical features, laboratory tests, duration of hospitalization, and the time to negative turn of novel coronavirus nucleic acid were collected and analysed. Kruskal-Wallis H test, chi-square test or Fisher exact test were used for comparison among three groups. Results: Among the 43 patients with allergic diseases, 28 were males and 15 were females, with an age of 4.4 (2.1, 8.2) years on admission, including 32 mild cases and 11 common cases. The allergic disease group included 20 cases (46.5%) of atopic dermatitis and eczema, followed by 14 cases (32.6%) of rhinitis, 8 cases (18.6%) of food allergies, 7 cases (16.3%) of asthma, 4 cases (9.3%) of allergic conjunctivitis and 2 cases (4.7%) of drug allergy. Among the 114 cases without underlying diseases, 57 were males and 57 were females, with an age of 2.8 (1.2, 5.6) years on admission, including 93 mild cases and 21 common cases. Among the 16 cases with other underlying diseases, 9 were males and 7 were females, with an age of 3.0 (2.6, 10.8) years on admission, including 13 cases mild and 3 cases common cases. Children with allergic diseases had higher frequency of sore throat and vomiting than those without underlying diseases (10 cases (23.3%) vs.9 cases (7.9%), 14 cases (32.6%) vs. 11 cases (9.6%), χ²=6.93, 12.24, both P<0.05). The lymphocyte count of patients with allergic disease was lower than those without underlying disease (1.1 (0.7,1.7)×109 vs. 1.6 (1.1,2.7)×109/L, H=-28.00,P=0.005). There were no significant differences in age, gender, typing of SARS-CoV-2, the duration of hospitalization, cycle threshold values of SARS-CoV-2 and the time to negative turn of novel coronavirus nucleic acid among the three groups (all P>0.05). Conclusions: Children with allergic diseases may suffer from sore throat and vomiting more frequently when infected with SARS-CoV-2 Omicron variant. The combination of allergic diseases hardly influenced the disease course of SARS-CoV-2 in children.


Assuntos
Masculino , Feminino , Humanos , Criança , SARS-CoV-2 , Estudos Transversais , COVID-19 , China/epidemiologia , Hipersensibilidade Alimentar , Faringite
11.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-965188

RESUMO

Objective Tto analyze the spatial distribution and characteristics of the national AIDS/HIV epidemics from 2009 to 2020 to discover its distribution, aggregation, and hot spots, and provide corresponding suggestions for AIDS prevention and control. Methods Spatial autocorrelation analysis, hot spot analysis, and Kriging interpolation prediction were used to describe, analyze, and predicting the spatial distribution of AIDS epidemics across the country. Results The national AIDS incidence and mortality rate increased yearly, but the growth rate shows a downward tendency with uneven spatial distribution,focusing on the southwest and northwest regions; the average annual incidence rate of AIDS ( Moran's I> 0, P 0, P “high-high” clusters of AIDS incidence; Sichuan, Yunnan, Guangxi,Hunan,Xinjiang and Guizhou were the areas with “high-high” clusters of average annual mortality. The “hot spot” areas were mainly concentrated in the southwestern part of China, and the “cold spot” areas were mainly concentrated in the eastern coastal and northern parts of China; Kriging interpolation predicted that Xinjiang would be the new hot spot area for future epidemics. Conclusion The spatial distribution of AIDS in China is uneven, showing spatial aggregation, hot spots and cold spots coexist, and the high-risk areas will continue to expand in the future.So the prevention and control work should be carried out in a targeted and localized manner.

12.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-980800

RESUMO

As an indicator that measures the degree of implementation of intervention measures during the implementation process, fidelity could be used for monitoring and quality evaluation of the completion degree of intervention measures, and plays an important role in improving the degree of intervention implementation and clarifying the factors that affect intervention implementation. This article aims to introduce the connotation and significance, measurement, control, and current application status of fidelity, as well as the current application status of fidelity in acupuncture-moxibustion clinical research and its inspiration for future research. Meanwhile, based on the existing evaluation tool development methods of fidelity and the characteristics of acupuncture-moxibustion clinical research, a preliminary fidelity evaluation framework is proposed. Introducing fidelity into acupuncture-moxibustion clinical research could improve the implementation quality and compliance of acupuncture-moxibustion in clinical research, increase the credibility and effectiveness of clinical research results, and promote the transformation of acupuncture-moxibustion experience into easily learnable and promotable treatment plans.


Assuntos
Moxibustão , Terapia por Acupuntura
13.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-1007844

RESUMO

OBJECTIVE@#This study aimed to reveal the insomnia burden and relevant influencing factors among informal caregivers (ICs) of hospitalized patients with lung cancer.@*METHODS@#A cross-sectional study on ICs of hospitalized patients with lung cancer was conducted from December 31, 2020 to December 31, 2021. ICs' burden was assessed using the Caregiver Reaction Assessment (CRA), Hospital Anxiety and Depression Scale (HADS), and Insomnia Severity Index (ISI). Linear and logistic regression models were used to identify the influencing factors.@*RESULTS@#Among 289 ICs of hospitalized patients with lung cancer, 83 (28.72%), 53 (18.34%), and 14 (4.84%) ICs experienced mild, moderate, and severe insomnia, respectively. The scores concerning self-esteem, lack of family support, financial problems, disturbed schedule, and health problems were 4.32 ± 0.53, 2.24 ± 0.79, 2.84 ± 1.14, 3.63 ± 0.77, and 2.44 ± 0.95, respectively. ICs with higher Activities of Daily Living Scale (ADLS) scores were associated with a lower risk of insomnia, with an odd ratio ( OR) and 95% confidence interval ( CI) of 0.940 (0.898-0.983). Among the ICs, female gender ( OR = 2.597), alcohol consumption ( OR = 3.745), underlying medical conditions ( OR = 11.765), long-term caregiving experience ( OR = 37.037), and higher monthly expenses ( OR = 5.714) were associated with a high risk of insomnia.@*CONCLUSION@#Of the hospitalized patients with lung cancer, 51.9% experienced insomnia. Patients' ADL, ICs gender, alcohol consumption, underlying medical conditions, caregiving duration, and monthly expenses were influencing factors. Therefore, prompt screening and early intervention for ICs of patients with lung cancer is necessary.


Assuntos
Humanos , Feminino , Cuidadores , Atividades Cotidianas , Estudos Transversais , Distúrbios do Início e da Manutenção do Sono/epidemiologia , Neoplasias Pulmonares/epidemiologia
14.
Chinese Acupuncture & Moxibustion ; (12): 1315-1323, 2023.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-1007489

RESUMO

OBJECTIVES@#To evaluate the report quality, methodological quality and evidence quality of the systematic reviews and meta-analyses (SRs/MAs) of acupuncture for in vitro fertilization-embryo transfer (IVF-ET).@*METHODS@#The SRs/MAs of acupuncture for IVF-ET were searched electronically from databases of CNKI, Wanfang, VIP, SinoMed, PubMed, Embase, Cochrane Library, from inception of each database to September 27th, 2022. Two reviewers independently screened the literature and extracted the data. Using PRISMA statement, the AMSTAR 2 scale and the GRADE system, the report quality, methodological quality and evidence quality of the included SRs/MAs were assessed.@*RESULTS@#A total of 28 SRs/MAs were included, with PRISMA scores ranging from 8.5 points to 27 points. The problems of report quality focused on protocol and registration, retrieval, risk of bias in studies, additional analysis, limitations and funding. The methodological quality of included studies was generally low, reflecting on items 2, 3, 7, 10, 12 and 16. A total of 85 outcome indexes were included in the GRADE system for evidence grade evaluation. Most of the evidences were low or very low in quality. The reasons for the downgrade were related to study limitations, inconsistency, imprecision and publication bias.@*CONCLUSIONS@#Acupuncture therapy improves the outcomes of IVF-ET, but the methodological quality and evidence quality of related SRs/MAs are low. It is recommended to conduct more high-quality studies in the future to provide more reliable evidences.


Assuntos
Terapia por Acupuntura/métodos , Bases de Dados Factuais , Transferência Embrionária , Fertilização in vitro , Viés de Publicação , Revisões Sistemáticas como Assunto
15.
Chinese Pharmacological Bulletin ; (12): 1438-1443, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1013954

RESUMO

Aim To observe the effect of betulinic acid (BA) on the migration and invasion of human gastric cancer MKN-45 cells induced by transforming growth factor-pi (TGF-β1), and to explore the effect of BA on epithelial-mesenchymal transition (EMT) and the potential mechanism. Methods The MKN-45 cells were cultivated in vitro, and the effects of different concentrations of BA on the proliferation of MKN-45 cells at 24, 48 and 72 h were detected using CCK-8 method. The effects of BA (5, 10, 20 jjunol • L) and TGF-01 inhibitor LY2109761 (10

16.
Chinese Pharmacological Bulletin ; (12): 580-587, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1013842

RESUMO

Aim To study the hypnotic effect and safety of compound anshen essential oil. Methods Gas chromatograph-mass spectrometer (GC-MS) was used to analyze the main active components of compound anshen essential oil. The mouse model of insomnia was established by intraperitoneal injection of para-chloro-phenyl alanine ( PC PA ) , combined with pentobarbital sodium sleep experiment and EEG characteristic monitoring in rats to study the hypnotic effect and mechanism. The safety of compound anshen essential oil was evaluated by acute toxicity test, skin irritation/allergy test and 90-day repeated administration toxicity test. The clinical effect and safety were evaluated by using the sleep monitoring technology for micro-motion sensitive mattress. Results Four components, including Atractylone (34.61%), (+) -Limonene (17.80%) , Linalool (11.63%), and Ocimene (11.67%) , were detected as the main active components of compound anshen essential oil. Compound anshen essential oil in-halation administration for seven days could effectively reduce the autonomic activity of insomnia mice, shorten the sleep latency (P <0.05) , improve the sleep duration, increase of neurotransmitters such as 5-hydroxy tryptamine (5-HT) and -γ-aminobutyric acid (GABA) in brain of mice with insomnia, and the medium dose group had better hypnotic effect. There was no death or adverse reaction in the safety evaluation test. The sleep balance index of 10 subjects with difficulty in falling a-sleep significantly increased (P <0.05), sleep latency was significantly shortened (P <0.05) , total sleep duration and sleep efficiency were improved, and no ad¬verse reactions were found after using the compound anshen essential oil for two days. Conclusions The compound anshen essential oil developed by the research team is safe and effective in relieving sleep disorders, which may be closely related to the co-regulation of the levels of neurotransmitters such as 5-HT and GABA by the four main active components.

17.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-985936

RESUMO

Objective: To investigate the quality of life and associated factors in patients with coronary heart disease (CHD) in China. Methods: A cross-sectional study of 25 provinces and cities in China was performed from June to September 2020. A questionnaire was used to collect the socio-demographic and clinical information of patients with CHD, while the European Five-dimensional Quality of Life Scale (EQ-5D) was used to assess the quality of life. Multiple linear regression model was performed to analyze the associated factors. Results: The median age of the 1 075 responders was 60 (52, 67) years, and 797 (74.1%) were men. The EQ-5D and EQ-VAS indices were 0.7 (0.5, 0.8) and 60.0 (40.0, 80.0). Among the five dimensions in the quality of life scale, the frequency of anxiety/depression was the highest (59.8%), while problems in self-care was the lowest (35.8%). In the multiple linear regression model, female, increasing age, obesity, comorbidity(ies), anxiety/depression, social media channels, and receiving the CABG therapy were associated with the lower EQ-5D index (all P<0.05). In addition, increasing age, obesity, comorbidity (ies), depression, anxiety and depression, social media channels, and receiving the CABG therapy were associated with lower EQ-VAS index (all P<0.05). Conclusion: Over half of the patients with CHD in China have a low quality of life, which is related to gender, age, obesity, treatment pathway, the presence or absence of comorbidity (ies), and psychological state. In addition to managing the adverse effects of traditional socio-demographic factors on the quality of life, clinical practices should pay attention to the psychological state of patients. Moreover, establishing a WeChat group for doctor-patient communication could improve the quality of life of CHD patients.


Assuntos
Masculino , Humanos , Feminino , Qualidade de Vida/psicologia , Autorrelato , Estudos Transversais , Doença das Coronárias , Inquéritos e Questionários , Obesidade
18.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-985515

RESUMO

Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.


Assuntos
Gravidez , Criança , Humanos , Feminino , Hemoglobinas Glicadas , Estudos de Coortes , Diabetes Mellitus/diagnóstico , Sensibilidade e Especificidade , Curva ROC
19.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-985507

RESUMO

Objective: To analyze the drug resistance and multilocus sequence typing of five types of diarrheagenic Escherichia coli (DEC) isolated from diarrhea outpatients of diarrhea comprehensive monitoring designated hospital in Qingpu District, Shanghai from 2015 to 2019. Methods: From January 2015 to December 2019, five types of DEC, isolated and identified from diarrhea outpatient cases' anal swabs of the Qingpu branch of Zhongshan Hospital were collected to determine the minimal inhibitory concentration by using the micro broth dilution susceptibility test. The strains, resistant to the third-generation cephalosporins or carbapenems, or producing ESBLs, were selected based on the results of sensitivity tests and determined by WGS. The MLST typing of DEC was analyzed based on the WGS technology and the minimum spanning tree was constructed by BioNumerics 7.6 software to analyze the local dominant flora. Results: A total of 513 strains of DEC were detected and isolated from 4 494 anal swabs, with a detection rate of 11.42%. About 500 strains were tested for drug sensitivity to nine antibiotics in four classes, including 330 strains of enterotoxigenic E.coli (ETEC), 72 strains of enteroaggregative E.coli (EAEC), 95 strains of enteropathogenic E.coli (EPEC), 1 strain of enterohemorrhagic E.coli (EHEC), and 2 strains of enteroinvasive E.coli (EIEC). From 2015 to 2019, the resistance rate of cefotaxime-clavulanic acid was significantly different (P<0.05). The resistance rate of virulence types of DEC to nalixic acid was significantly different (P<0.05). About 71 strains of DEC were determined by WGS, and 77 drug-resistant genes were detected. Strains were classified into 32 ST subtypes, with the dominant genotypes being ST-1491 (29.6%, 21/71) and ST-10 Complex (23.9%, 17/71). All ST-1491 produced ESBLs, which were blaCTX-M gene mutant strains. The dominant type of ST-10 complex was ST-218 (35.3%, 6/17). In addition, 8 strains of EAEC, 14 strains of EPEC and 49 strains of ETEC were classified into 7, 14 and 18 ST subtypes, respectively. Conclusion: The drug resistance of DEC strains from the diarrhea outpatient case of Qingpu District is serious. The ST types of EAEC and EPEC are highly polymorphic. The dominant ST types of DEC are basically consistent with the common genotypes in southeast China.

20.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1009165

RESUMO

OBJECTIVE@#To observe the clinical efficacy of intercondylar fossa plasty in preventing intercondylar fossa impingement syndrome after high tibial osteotomy.@*METHODS@#From August 2018 to August 2020, 84 patients with inverted knee osteoarthritis were treated by arthroscopy combined with high tibial osteotomy, and were divided into two groups with 42 cases in each group according to different surgical methods. In the intercondylar fossa plasty group, there were 13 males and 29 females, age ranged from 52 to 67 years old with an average of(58.27±4.32) years old, and arthroscopic intercondylar fossa plasty was performed first, and then high tibial osteotomy. In the arthroscopic cleansing group, 16 males and 26 females, age ranged from 50 to 71 years old with an average of (59.02±5.14) years old, underwent arthroscopic cleansing and then high tibial osteotomy. Postoperative treatment was evaluated using visual analogue scale(VAS), hospital for special surgery (HSS) score for the knee, and the occurrence of intercondylar percussa impingement.@*RESULTS@#All 84 patients were followed up, the duration ranged from 12 to 18 months with an average of (14.1±1.6) months. The VAS and HSS score of knee joint at 6, 12 and 18 months after surgery were significantly improved compared with preoperative period, and there was no significant difference between the two groups (P>0.05), but the incidence of intercondylar fossa index and intercondylar fossa impact between the two groups was significantly compared 18 months after surgery (P<0.05).@*CONCLUSION@#Intercondylar fossa plasty can effectively prevent the incidence of intercondylar fossa impact after high tibial osteotomy, and has a more significant effect on postoperative knee pain and function improvement.


Assuntos
Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Tíbia/cirurgia , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/cirurgia , Resultado do Tratamento , Osteotomia/métodos , Dor Pós-Operatória , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...