RESUMO

We present the outcome of the first clinical application of a new technique using an epineural flap to bridge a short nerve defect. A 28-year-old male had suffered a radial nerve laceration at the lower third of the arm, proximal to the brachioradialis branch, 3 weeks before surgery. During surgery, a neuroma-in-continuity was excised preserving the epineural sleeve. Two longitudinal epineural flaps were created, one from the proximal and one from the distal nerve stump and used to bridge a 1-cm-long nerve defect. Each epineurium flap was sutured to the intact epineurium of the other side and additionally to each other. An electromagnetic nerve stimulator was used to enhance the nerve regeneration process. Nerve regeneration was followed up for 17 months with excellent functional results.


Assuntos
Neuroma/cirurgia , Neuropatia Radial/cirurgia , Retalhos Cirúrgicos , Adulto , Humanos , Lacerações/complicações , Masculino , Regeneração Nervosa , Neuroma/etiologia , Nervos Periféricos/transplante , Período Pós-Operatório , Nervo Radial/lesões , Nervo Radial/fisiopatologia , Neuropatia Radial/etiologia , Técnicas de Sutura , Transplante Autólogo
2.
Int Orthop ; 33(2): 353-8, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17985130

RESUMO

The reliability and validity of the Hartofilakidis et al. classification system in adults with congenital hip disease (CHD) were examined. The radiographs of 102 adult patients (158 hips) with CHD were independently assessed by three senior surgeons. Interobserver variability was assessed by examining the agreement between the three raters while validity of the classification system was assessed by examining the agreement between the assessment by either one of the three raters and the intraoperative finding (reference standard). The interobserver agreement between the three observers was high ranging from 0.720 to 0.854 (substantial to excellent) while the agreement of the preoperative prediction with the intraoperative findings was 87.4% (K = 0.823, excellent agreement). The Hartofilakidis et al. classification system reliably predicts from preoperative pelvis radiographs the bone deficiencies encountered during the operation.


Assuntos
Luxação Congênita de Quadril/classificação , Adulto , Fatores Etários , Estudos de Coortes , Feminino , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/epidemiologia , Humanos , Masculino , Variações Dependentes do Observador , Ortopedia/métodos , Probabilidade , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
3.
J Bone Joint Surg Br ; 90(7): 870-3, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18591594

RESUMO

The effect of weight-bearing on the height of the patellar using four radiological indices was studied in 25 healthy men using lateral radiographs of the knee in 30 degrees of flexion non-weight-bearing and weight-bearing. The position of the patella was quantified using the Insall-Salvati, the modified Insall-Salvati, the Blackburne-Peel and the Caton indices. The contraction of the quadriceps on weight-bearing resulted in statistically significant proximal displacement of the patella with all four indices studied. The mean Insall-Salvati index was 0.919 (SD 0.063) before and 1.109 (SD 0.042) after weight-bearing (p = 0.001), while the mean modified Insall-Salvati index was 0.734 (SD 0.039) before and 0.896 (SD 0.029) after weight-bearing (p = 0.041). Similarly, the Blackburne-Peel index was 0.691 (SD 0.09) before and 0.807 (SD 0.137) after weight-bearing (p = 0.012). The mean Caton index was 0.861 (SD 0.09) before and 0.976 (SD 0.144) after weight-bearing (p = 0.023). The effect of quadriceps contraction should be considered in clinical studies where the patellar position indices are reported.


Assuntos
Contração Muscular/fisiologia , Patela/anatomia & histologia , Ligamento Patelar/fisiologia , Músculo Quadríceps/fisiologia , Suporte de Carga/fisiologia , Adulto , Humanos , Masculino , Patela/diagnóstico por imagem , Ligamento Patelar/diagnóstico por imagem , Músculo Quadríceps/diagnóstico por imagem , Radiografia
4.
J Bone Joint Surg Br ; 90(6): 724-30, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18539664

RESUMO

We have evaluated the results of total hip replacement in patients with congenital hip disease using 46 cemented all-polyethylene Charnley acetabular components implanted with the cotyloplasty technique in 34 patients (group A), and compared them with 47 metal-backed cementless acetabular components implanted without bone grafting in 33 patients (group B). Patients in group A were treated between 1988 and 1993 and those in group B between 1990 and 1995. The mean follow-up for group A was 16.6 years (12 to 18) and the mean follow-up for group B was 13.4 years (10 to 16). Revision for aseptic loosening was undertaken in 15 hips (32.6%) in group A and in four hips (8.5%) in group B. When liner exchange was included, a total of 13 hips were revised in group B (27.7%). The mean polyethylene wear was 0.11 mm/yr (0.002 to 0.43) and 0.107 mm/yr (0 to 0.62) for groups A and B, respectively. Polyethylene wear in group A was associated with linear osteolysis, and in group B with expansile osteolysis. In patients with congenital hip disease, when 80% cover of the implant can be obtained, a cementless acetabular component appears to be acceptable and provides durable fixation. However, because of the type of osteolysis arising with these devices, early exchange of a worn liner is recommended before extensive bone loss makes revision surgery more complicated.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Luxação Congênita de Quadril/cirurgia , Adulto , Idoso , Cimentos Ósseos , Feminino , Seguimentos , Luxação Congênita de Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Radiografia , Reoperação , Resultado do Tratamento
5.
J Bone Joint Surg Br ; 90(5): 579-83, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18450622

RESUMO

Our study evaluated the reliability of the Crowe and Hartofilakidis classification systems for developmental dysplasia of the hip in adults. The anteroposterior radiographs of the pelvis of 145 patients with 209 osteoarthritic hips were examined twice by three experienced hip surgeons from three European countries and the abnormal hips were rated using both classifications. The inter- and intra-observer agreement was calculated. Interobserver reliability was evaluated using weighted and unweighted kappa coefficients and for the Crowe classification, among the three pairs there was a minimum kappa coefficient with linear weighting of 0.90 for observers A and C and a maximum kappa coefficient of 0.92 for observers B and C. For the Hartofilakidis classification, the minimum kappa value was 0.85 for observers A and B, and the maximum value was 0.93 for observers B and C. With regard to intra-observer reliability, the kappa coefficients with linear weighting between the two evaluations of the same observer ranged between 0.86 and 0.95 for the Crowe classification and between 0.80 and 0.93 for the Hartofilakidis classification. The reliability of both systems was substantial to almost perfect both for serial measurements by individual readers and between different readers, although the information offered was dissimilar.


Assuntos
Luxação Congênita de Quadril/classificação , Índice de Gravidade de Doença , Adulto , Luxação Congênita de Quadril/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Acta Neurochir Suppl ; 100: 73-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17985550

RESUMO

BACKGROUND: [corrected] Nerve grafting is the most reliable used procedure to bridge a neural defect, but it is associated with donor site morbidity. In experimental surgery the search for an optimal nerve conduit led to the use of biological and artificial material. Nerve regeneration through epineural conduits for bridging short nerve defect was examined. METHODS: Four groups including 126 New Zealand rabbits were used. There were 3 study groups (A, B and C) and 1 control group (D). A 10-mm long sciatic nerve defect was bridged either with 3 variations of an epineural flap (Groups A, B and C) or with a nerve graft (Group D). Animals from all groups were examined 21, 42 and 91 days postoperatively to evaluate nerve regeneration employing light microscopy and immunocytochemistry. Nerve regeneration was studied in transverse sections at 3, 6 and 9 mm from the proximal stump. Using muscle stimulator the gastrocnemius contractility was examined at 91 days post surgery in all groups. FINDINGS: Immunohistochemical and functional evaluation showed nerve regeneration resembling the control group, especially in group A, were an advancement epineural flap was used. CONCLUSION: An epineurial flap can be used to bridge a nerve defect with success.


Assuntos
Regeneração Tecidual Guiada/métodos , Tecido Nervoso/transplante , Nervo Isquiático/cirurgia , Retalhos Cirúrgicos , Animais , Fibrina/metabolismo , Fibronectinas/metabolismo , Imuno-Histoquímica , Contração Muscular , Músculo Esquelético/inervação , Músculo Esquelético/fisiopatologia , Regeneração Nervosa , Coelhos , Nervo Isquiático/lesões , Nervo Isquiático/patologia , Nervo Isquiático/fisiopatologia , Transplante Autólogo
7.
Artigo em Inglês | MEDLINE | ID: mdl-17947811

RESUMO

In order to effectively prevent osteoporosis-related fractures, one must aim to prevent both osteoporosis, as well as the events and circumstances that may lead to injury, ultimately resulting in fracture. Among all the osteoporotic fractures that can occur, hip fractures are associated with a severe decrease in quality of life and high mortality, which reaches 51% at one year post-fracture in nonagenarians. Prevention of osteoporosis should ideally begin in childhood, aiming to achieve high peak bone mass accompanied by an inherently healthy lifestyle throughout life, in order to minimize bone loss during middle and third age, and in parallel to avoid or diminish other fracture risk factors. There are numerous fracture risk factors, including age, gender, race, lifestyle and concomitant medical conditions, which either cannot or can be modified, to a greater or lesser degree. Falls consist a previously underestimated risk factor, responsible for a large percentage of fractures. International and national strategies aimed at public awareness, early identification of those at increased risk for fracture and preventive or therapeutic intervention may succeed in subduing the currently increasing prevalence of osteoporotic fractures.


Assuntos
Envelhecimento/patologia , Fraturas Ósseas/etiologia , Fraturas Ósseas/prevenção & controle , Osteoporose/complicações , Acidentes por Quedas/prevenção & controle , Acidentes por Quedas/estatística & dados numéricos , Animais , Densidade Óssea/efeitos dos fármacos , Densidade Óssea/fisiologia , Suplementos Nutricionais/normas , Terapia por Exercício/normas , Fraturas Ósseas/fisiopatologia , Fraturas do Quadril/etiologia , Fraturas do Quadril/fisiopatologia , Fraturas do Quadril/prevenção & controle , Humanos , Osteoporose/fisiopatologia , Osteoporose/prevenção & controle , Osteoporose Pós-Menopausa/complicações , Osteoporose Pós-Menopausa/fisiopatologia , Osteoporose Pós-Menopausa/prevenção & controle , Fatores de Risco
8.
J Musculoskelet Neuronal Interact ; 5(2): 170-3, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15951634

RESUMO

The medial collateral (MCL) and the anterior cruciate ligament (ACL) of the rat's knee are frequently used in biomedical research and occasionally in ligament healing studies. The contralateral normal ligament serves as a control. In this study the presence of symmetry in the biomechanical properties of the MCL and the ACL was investigated. Bilateral femur-MCL-tibia and femur-ACL-tibia preparations were obtained from the hind limbs of sixty rats and were subjected to tensile testing to failure under the same loading conditions. Tensile load to failure, stiffness and energy absorption capacity were measured and the mode of failure was recorded. All biomechanical parameters were not significantly different between the two knees of the same animal, although significant individual variation was evident. The most common mechanism of failure was mid-substance tear. Symmetry seems to exist in the biomechanical properties of the MCL and the ACL in the rat knee. When ligament healing is evaluated, increased group size is necessary and the use of a normal control group may be advisable. The contralateral normal knee ligament may serve as a control when the properties of an injured ligament are evaluated and when the parameters of tensile testing failure under similar load conditions are applied.


Assuntos
Ligamento Cruzado Anterior/fisiologia , Lateralidade Funcional , Membro Posterior/fisiologia , Ligamento Colateral Médio do Joelho/fisiologia , Estresse Mecânico , Animais , Fenômenos Biomecânicos , Técnicas In Vitro , Masculino , Ratos , Resistência à Tração/fisiologia
9.
J Hand Surg Br ; 29(1): 32-4, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14734067

RESUMO

This study investigated the effects of alkalinization and warming of lidocaine 1% on injection pain in patients undergoing carpal tunnel decompression. Sixty-four adult patients were randomly allocated into one of three groups: Group A (n=20) received plain lidocaine 1%, Group B (n=22) alkalinized lidocaine and Group C (n=22) warmed and alkalinized lidocaine. Pain on needle insertion and on infiltration was assessed using a 100mm Visual Analogue Scale (VAS). There was no significant difference regarding pain on needle insertion whereas significant differences were noted in reference to infiltration pain. In Groups B and C (alkalinized lidocaine) the VAS scores on skin infiltration were significantly lower than in Group A, while the pain score in Group C (alkalinized and warmed lidocaine) was significantly lower than in Group B.


Assuntos
Síndrome do Túnel Carpal/cirurgia , Descompressão Cirúrgica , Lidocaína/administração & dosagem , Anestesia Local , Soluções Tampão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor
SELEÇÃO DE REFERÊNCIAS