Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Chest ; 147(5): 1299-1306, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25275253

RESUMO

BACKGROUND: Some tumors previously staged as N2 disease, using the Mountain-Dresler/American Thoracic Society (MD-ATS) map are staged as N1 per the new International Association for the Study of Lung Cancer (IASLC) lymph node (LN) map. We aimed to evaluate the effectiveness of the IASLC LN map in stratifying prognosis in patients with non-small cell lung cancer (NSCLC) and LN metastasis in nodal stations 4 or 10. METHODS: Of 2,086 patients undergoing curative surgical resection for NSCLC, we searched for patients who had LNs harboring cancer cells in nodal stations 10 or 4 (n = 531) and reclassified them into three different subgroups (N1 [N1 according to both the MD-ATS and IASLC maps], in-between [N2 according to the MD-ATS map but N1 by the IASLC map], and N2 [N2 according to both maps]) based on histopathologic results. We compared disease-free survival (DFS) among the three subgroups by using the Kaplan-Meier method and log-rank analysis. RESULTS: Of 531 patients, 295 belonged to the N1 group, 66 patients belonged to in-between group, and 170 patients belonged to N2 group, according to the IASLC map. The cumulative DFS rates at 5 years for the N1, in-between, and N2 groups were 47%, 39%, and 29%, respectively. In multivariate analysis, LN ratio was identified as significant independent prognostic factor (hazard ratio, 2.877; 95% CI, 1.391-5.950; P = .004). CONCLUSIONS: The changed definition between N1 and N2 diseases by the IASLC LN map works well, as expected, in stratifying patient prognosis. Positive LN ratio may be more valuable than the nodal stations involved in predicting patient survival in resectable NSCLC.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias Pulmonares/patologia , Feminino , Humanos , Cooperação Internacional , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias/normas , Encaminhamento e Consulta , Estudos Retrospectivos , Sociedades Científicas , Centros de Atenção Terciária
2.
Korean J Radiol ; 14(6): 968-76, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24265575

RESUMO

OBJECTIVE: To compare the diagnostic performance of light emitting diode (LED) backlight monitors and cold cathode fluorescent lamp (CCFL) monitors for the interpretation of digital chest radiographs. MATERIALS AND METHODS: We selected 130 chest radiographs from health screening patients. The soft copy image data were randomly sorted and displayed on a 3.5 M LED (2560 × 1440 pixels) monitor and a 3 M CCFL (2048 × 1536 pixels) monitor. Eight radiologists rated their confidence in detecting nodules and abnormal interstitial lung markings (ILD). Low dose chest CT images were used as a reference standard. The performance of the monitor systems was assessed by analyzing 2080 observations and comparing them by multi-reader, multi-case receiver operating characteristic analysis. The observers reported visual fatigue and a sense of heat. Radiant heat and brightness of the monitors were measured. RESULTS: Measured brightness was 291 cd/m(2) for the LED and 354 cd/m(2) for the CCFL monitor. Area under curves for nodule detection were 0.721 ± 0.072 and 0.764 ± 0.098 for LED and CCFL (p = 0.173), whereas those for ILD were 0.871 ± 0.073 and 0.844 ± 0.068 (p = 0.145), respectively. There were no significant differences in interpretation time (p = 0.446) or fatigue score (p = 0.102) between the two monitors. Sense of heat was lower for the LED monitor (p = 0.024). The temperature elevation was 6.7℃ for LED and 12.4℃ for the CCFL monitor. CONCLUSION: Although the LED monitor had lower maximum brightness compared with the CCFL monitor, soft copy reading of the digital chest radiographs on LED and CCFL showed no difference in terms of diagnostic performance. In addition, LED emitted less heat.


Assuntos
Eletrodos , Interpretação de Imagem Assistida por Computador , Neoplasias Pulmonares/diagnóstico por imagem , Intensificação de Imagem Radiográfica/instrumentação , Radiografia Torácica/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Temperatura Baixa , Apresentação de Dados , Desenho de Equipamento , Humanos , Curva ROC , Estudos Retrospectivos
3.
AJR Am J Roentgenol ; 201(3): 471-81, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23971438

RESUMO

OBJECTIVE: The number of citations an article receives after its publication reflects its impact in the scientific community. The aim of this study was to identify and characterize the 100 top-cited articles published in radiology journals. MATERIALS AND METHODS: The top-cited articles published in 12 radiology journals were identified using the database of Science Citation Index Expanded (1945-2012). The 100 top-cited articles were selected and analyzed with regard to the number of citations, year of publication, publishing journal, authorship, institution and country of origin, type of article, radiologic subspecialty, main topic, and radiologic technique. RESULTS: The 100 top-cited articles were published in eight radiology journals, led by Radiology (n=67) and followed by the American Journal of Roentgenology (n=11). These articles were published between 1939 and 2006 with a mean of 664.3 citations per article (range, 371-6931). Seventy-eight articles were published after 1979, 57 originated from the United States, and 69 were original articles. The most common subspecialties of study were interventional radiology (n=19), neuroradiology (n=15), and breast imaging (n=11). The main topics of articles were radiofrequency ablation of hepatic tumors (n=9), followed by receiver operating characteristic curves (n=6). CONCLUSION: Our study presents a detailed list and analysis of the 100 top-cited articles published in radiology journals, which provides insight into historical developments in the field of radiology.


Assuntos
Bibliometria , Pesquisa Biomédica/tendências , Publicações Periódicas como Assunto/estatística & dados numéricos , Editoração/tendências , Radiologia , Humanos
4.
Chest ; 144(4): 1291-1299, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23722583

RESUMO

BACKGROUND: Little is known about the histopathology and prognosis of persistent pure ground-glass opacity nodules (GGNs) of ≥ 10 mm in diameter. We aimed to compare the morphologic features of persistent pure GGNs of ≥ 10 mm in diameter at thin-section CT (TSCT) scan with histopathology and patient prognosis. METHODS: A total of 46 resected GGNs that were evaluated with TSCT scan and followed up for ≥ 3 years were included in this study. Correlations between histopathology (adenocarcinoma in situ [AIS], minimally invasive adenocarcinoma [MIA], and invasive adenocarcinoma) and CT scan characteristics were examined. CT scan and clinicodemographic data were investigated by univariate and multivariate analyses to identify features that helped distinguish invasive adenocarcinoma from AIS or MIA. Disease recurrence was also evaluated. RESULTS: The nodules included 19 AISs (41%), nine MIAs (20%), and 18 invasive adenocarcinomas (39%). On univariate analysis, the presence of air bronchogram (P = .012), size of nodule (P = .032, cutoff = 16.4 mm in diameter), and mass of nodule (P = .040, cutoff = 0.472 g) were significant factors that differentiated invasive adenocarcinoma from AIS or MIA. On multivariate analysis, size (P = .010) and mass of nodule (P = .016) were significant determinants for invasive adenocarcinoma. There were no cases of recurrence during a follow-up period of ≥ 3 years after surgical resection. CONCLUSIONS: In persistent pure GGNs of ≥ 10 mm in diameter, the size and mass of the nodule are determinants of invasive adenocarcinoma, for which surgical resection leads to excellent prognosis.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos
5.
Eur J Radiol ; 80(2): 208-12, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20576384

RESUMO

PURPOSE: The aim of this retrospective study was to evaluate the diagnostic value of CT features of the gallbladder in the prediction of gallstone pancreatitis. MATERIALS AND METHODS: Eighty-six patients who underwent a diagnostic computed tomography (CT) scan for acute pancreatitis were included. The readers assessed the presence of pericholecystic increased attenuation of the liver parenchyma, enhancement of gallbladder (GB) and common bile duct (CBD) wall, pericholecystic fat strands, GB wall thickening, stone in the GB or CBD, and focal or diffuse manifestations of pancreatitis on abdominal CT scans. In addition, the maximal transverse luminal diameters of the GB and CBD were measured. RESULTS: The presence of pericholecystic increased attenuation of the liver parenchyma, GB wall enhancement and thickening, pericholecystic fat strands, stone in the GB or CBD, and diffuse manifestations of pancreatitis achieved statistical significance for differentiation of gallstone induced pancreatitis from non-biliary pancreatitis (p<0.05). The mean values of maximal transverse luminal diameter of GB and CBD were significantly higher in gallstone induced pancreatitis group (39.67±7.26 mm, 10.20±4.13 mm) than non-biliary pancreatitis group (27.01±6.14 mm, 3.85±2.51 mm, p<0.0001). CONCLUSION: Gallbladder features of CT in patients with pancreatitis could be the valuable clues for the diagnosis of gallstone induced pancreatitis.


Assuntos
Cálculos Biliares/complicações , Cálculos Biliares/diagnóstico por imagem , Pancreatite/diagnóstico por imagem , Pancreatite/etiologia , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Distribuição de Qui-Quadrado , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
Acta Radiol ; 51(6): 649-54, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20528649

RESUMO

BACKGROUND: Percutaneous injection of bone cement (acrylic cement) during percutaneous kyphoplasty and vertebroplasty can cause symptomatic or asymptomatic complications due to leakage, extravasation or vascular migration of cement. PURPOSE: To investigate and to compare the incidence and site of local leakage or complications of bone cement after percutaneous kyphoplasty and vertebroplasty using bone cement. MATERIAL AND METHODS: We retrospectively reviewed 473 cases of percutaneous kyphoplasty or vertebroplasty performed under fluoroscopic guidance. Of the 473 cases, follow-up CT scans that covered the treated bones were available for 83 cases (59 kyphoplasty and 24 vertebroplasty). RESULTS: The rate of local leakage of bone cement was 87.5% (21/24) for percutaneous vertebroplasty and 49.2% (29/59) for kyphoplasty. The most common site of local leakage was perivertebral soft tissue (n=8, 38.1%) for vertebroplasty. The most common site of local leakage was a perivertebral vein (n=7, 24.1%) for kyphoplasty. Two cases of pulmonary cement embolism developed: one case after kyphoplasty and one case after vertebroplasty. CONCLUSION: Local leakage of bone cement was more common for percutaneous vertebroplasty compared with kyphoplasty (P<0.005). The most common sites of local leakage were perivertebral soft tissue and perivertebral vein.


Assuntos
Cimentos Ósseos , Cifose/diagnóstico por imagem , Cifose/cirurgia , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Tomografia Computadorizada por Raios X , Vertebroplastia/efeitos adversos , Humanos , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...