Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ocul Immunol Inflamm ; 30(7-8): 1906-1912, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35081012

RESUMO

PURPOSE: To compare laser flare photometry (LFP) measurements of aqueous flare with Standardization of Uveitis Nomenclature (SUN) and modified SUN grading. METHODS: In this prospective study with multicenter design, uveitis patients were classified according to SUN and modified SUN grading scales. LFP was performed with Kowa FM-700 flaremeter. Mean LFP values were compared with SUN and MSUN scores. RESULTS: The study included 475 LFP measurements, of which 216, 48, 150, 31, 28 and 2 had 0, 0.5+, 1+, 1.5+, 2+ and 3+ flare, respectively. LFP values were significantly different between each two consecutive steps for both clinical gradings (all P < .05). Cut-off values for modified SUN grading steps were defined as 5.7, 9.7, 15.7 and 43.2 for 0/0.5+, 0.5+/ 1+, 1+/1.5+ and 1.5/2+ borders of clinical flare, respectively. CONCLUSIONS: LFP proves to be an objective measurement in analyzing aqueous flare comparable to both SUN and MSUN clinical grading systems.


Assuntos
Lasers , Humanos , Estudos Prospectivos
2.
Ocul Immunol Inflamm ; 30(2): 424-427, 2022 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-32966150

RESUMO

PURPOSE: To evaluate the effects of fluorescein fundus angiography (FFA) on semiautomated aqueous flare measurements. METHODS: Laser flare photometer (LFP) measurements was performed at baseline, 30 min, and 4 h after the intravenous administration of sodium fluorescein dye. FFA was performed immediately after the baseline LFP measurement. LFP values at 30 min and 4 h after FFA were compared to baseline values. Mean change in LFP measurements at 30 min and 4 hafter baseline was compared between FFA arm and controls. RESULTS: The mean flare measurement in the FFA and control arm dropped 6% (p value = 0.002) and 9% (p value = 0.04), respectively. Mean change in LFP measurement at 30 min and 4 h after baseline was not significant between FFA arm and controls. CONCLUSIONS: Administration of fluorescein dye does not increase LFP values. The decrease in the LFP measurement following FFA may be attributed to dilation drops.


Assuntos
Humor Aquoso , Uveíte Anterior , Fluoresceína/farmacologia , Angiofluoresceinografia , Humanos , Fotometria , Acuidade Visual
3.
Eur J Ophthalmol ; 32(4): 2291-2297, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34382443

RESUMO

BACKGROUND: To evaluate effect of maximal anterior cortical lens density, iris scatter and anterior chamber depth on laser flare photometry. METHODS: Patients diagnosed with clinical uveitis were enrolled in the study. Clinical flare gradings were recorded upon the Standardization of Uveitis Nomenclature. Aqueous flare was measured with an automated device (Kowa FM-700). Back-scattering from anterior cortical lens and anterior iris surface was calculated from Scheimpflug images. A curvilinear regression model was used to calculate estimated values for each clinical grade. These values were used to split cases in Group I (laser flare photometry lower than estimated) and Group II (laser flare photometry higher than estimated). Mean anterior chamber depth, pupil aperture, maximal anterior cortical lens density and iris scatter values were compared between two groups. A stepwise multiple regression analysis was performed to determine the effect of clinical flare gradings and ocular parameters on aqueous flare measurements. RESULTS: The study included 228 eyes of 114 cases. Scheimpflug images were obtained from 105 eyes. Estimated aqueous flare measurements (in photons/milliseconds) were 4.87, 8.50, 14.81, 25.83, 45.04 and 136.93 for 0, 0.5+, 1+, 1.5+, 2+ and 3+ clinical flare respectively. Group II had higher maximal anterior cortical lens density than Group I (96.6 ± 37.1 vs 77.9 ± 17.1 pixel unit, p = 0.001). The measured aqueous flare was significantly related to clinical flare, maximal anterior cortical lens density and pupil aperture (adjusted R2: 0.480, p < 0.001). CONCLUSION: The back-scattered light from anterior cortical lens could affect laser flare photometry measurements. This effect might be quantified by Scheimpflug imaging.


Assuntos
Uveíte Anterior , Uveíte , Câmara Anterior/diagnóstico por imagem , Humor Aquoso , Humanos , Lasers , Fotometria/métodos , Uveíte/diagnóstico , Uveíte Anterior/diagnóstico
4.
Am J Trop Med Hyg ; 105(6): 1782-1785, 2021 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-34544040

RESUMO

We report a case of human ocular onchocerciasis by zoonotic Onchocerca lupi presenting as nodular scleritis. Molecular analyses were used to confirm diagnosis at species level. In addition to few existing reports of human infection by O. lupi in Turkey, this case further suggests that the pathogen might be more common than previously reported, thus requiring further attention and investigations.


Assuntos
Músculos Oculomotores/patologia , Oncocercose Ocular/diagnóstico , Esclerite/diagnóstico , Diagnóstico Diferencial , Feminino , Humanos , Músculos Oculomotores/cirurgia , Oncocercose Ocular/patologia , Oncocercose Ocular/cirurgia , Turquia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...