1.
Cancers (Basel) ; 16(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38201648

RESUMO

BACKGROUND: This study aims to present the feasibility of developing a synchrotron-based proton ultra-high dose rate (UHDR) pencil beam scanning (PBS) system. METHODS: The RF extraction power in the synchrotron system was increased to generate 142.4 MeV pulsed proton beams for UHDR irradiation at ~100 nA beam current. The charge per spill was measured using a Faraday cup. The spill length and microscopic time structure of each spill was measured with a 2D strip transmission ion chamber. The measured UHDR beam fluence was used to derive the spot dwell time for pencil beam scanning. Absolute dose distributions at various depths and spot spacings were measured using Gafchromic films in a solid-water phantom. RESULTS: For proton UHDR beams at 142.4 MeV, the maximum charge per spill is 4.96 ± 0.10 nC with a maximum spill length of 50 ms. This translates to an average beam current of approximately 100 nA during each spill. Using a 2 × 2 spot delivery pattern, the delivered dose per spill at 5 cm and 13.5 cm depth is 36.3 Gy (726.3 Gy/s) and 56.2 Gy (1124.0 Gy/s), respectively. CONCLUSIONS: The synchrotron-based proton therapy system has the capability to deliver pulsed proton UHDR PBS beams. The maximum deliverable dose and field size per pulse are limited by the spill length and extraction charge.

2.
Int J Part Ther ; 8(1): 62-72, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34285936

RESUMO

PURPOSE: To describe an implementation of dual-energy computed tomography (DECT) for calculation of proton stopping-power ratios (SPRs) in a commercial treatment-planning system. The process for validation and the workflow for safe deployment of DECT is described, using single-energy computed tomography (SECT) as a safety check for DECT dose calculation. MATERIALS AND METHODS: The DECT images were acquired at 80 kVp and 140 kVp and were processed with computed tomography scanner software to derive the electron density and effective atomic number images. Reference SPRs of tissue-equivalent plugs from Gammex (Middleton, Wisconsin) and CIRS (Computerized Imaging Reference Systems, Norfolk, Virginia) electron density phantoms were used for validation and comparison of SECT versus DECT calculated through the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, California) application programming interface scripting tool. An in-house software was also used to create DECT SPR computed tomography images for comparison with the script output. In the workflow, using the Eclipse system application programming interface script, clinical plans were optimized with the SECT image set and then forward-calculated with the DECT SPR for the final dose distribution. In a second workflow, the plans were optimized using DECT SPR with reduced range-uncertainty margins. RESULTS: For the Gammex phantom, the root mean square error in SPR was 1.08% for DECT versus 2.29% for SECT for 10 tissue-surrogates, excluding the lung. For the CIRS Phantom, the corresponding results were 0.74% and 2.27%. When evaluating the head and neck plan, DECT optimization with 2% range-uncertainty margins achieved a small reduction in organ-at-risk doses compared with that of SECT plans with 3.5% range-uncertainty margins. For the liver case, DECT was used to identify and correct the lipiodol SPR in the SECT plan. CONCLUSION: It is feasible to use DECT for proton-dose calculation in a commercial treatment planning system in a safe manner. The range margins can be reduced to 2% in some sites, including the head and neck.

3.
Radiother Oncol ; 155: 212-218, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33186682

RESUMO

PURPOSE: Proton Pencil Beam Scanning (PBS) is an attractive solution to realize the advantageous normal tissue sparing elucidated from FLASH high dose rates. The mechanics of PBS spot delivery will impose limitations on the effective field dose rate for PBS. METHODS: This study incorporates measurements from clinical and FLASH research beams on uniform single energy and the spread-out Bragg Peak PBS fields to extrapolate the PBS dose rate to high cyclotron beam currents 350, 500, and 800 nA. The impact of the effective field dose rate from cyclotron current, spot spacing, slew time and field size were studied. RESULTS: When scanning magnet slew time and energy switching time are not considered, single energy effective field FLASH dose rate (≥40 Gy/s) can only be achieved with less than 4 × 4 cm2 fields when the cyclotron output current is above 500 nA. Slew time and energy switching time remain the limiting factors for achieving high effective dose rate of the field. The dose rate-time structures were obtained. The amount of the total dose delivered at the FLASH dose rate in single energy layer and volumetric field was also studied. CONCLUSION: It is demonstrated that while it is difficult to achieve FLASH dose rate for a large field or in a volume, local FLASH delivery to certain percentage of the total dose is possible. With further understanding of the FLASH radiobiological mechanism, this study could provide guidance to adapt current clinical multi-field proton PBS delivery practice for FLASH proton radiotherapy.


Assuntos
Terapia com Prótons , Prótons , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
4.
Br J Radiol ; 93(1116): 20190619, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-32960655

RESUMO

OBJECTIVES: Prompt gamma (PG) imaging has previously been demonstrated for use in proton range verification of a brain treatment with a homogeneous target region. In this study, the feasibility of PG imaging to detect anatomic change within a heterogeneous region is presented. METHODS: A prompt gamma camera recorded several fractions of a patient treatment to the base of skull. An evaluation CT revealed a decrease in sinus cavity filling during the treatment course. Comparison of PG profiles between measurement and simulation was performed to investigate range variations between planned and measured pencil beam spot positions. RESULTS: For one field, an average over range of 3 mm due to the anatomic change could be detected for a subset of spots traversing the sinus cavity region. The two other fields appeared less impacted by the change but predicted range variations could not be detected. These results were partially consistent with the simulations of the evaluation CT. CONCLUSION: We report the first clinical application of PG imaging that detected some of the expected small regional proton range deviations due to anatomic change in a heterogeneous region. However, several limitations exist with the technology that may limit its sensitivity to detect range deviations in heterogeneous regions. ADVANCES IN KNOWLEDGE: We report on the first detection of range variations due to anatomic change in a heterogeneous region using PGI. The results confirm the feasibility of using PG-based range verification in highly heterogeneous target regions to identify deviations from the treatment plan.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Raios gama , Prótons , Tomografia Computadorizada por Raios X , Estudos de Viabilidade , Humanos
5.
Int J Radiat Oncol Biol Phys ; 107(1): 79-87, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31987966

RESUMO

PURPOSE: We hypothesized that the radiation dose in high-ventilation portions of the lung better predicts radiation pneumonitis (RP) outcome for patients treated with proton radiation therapy (PR) and photon radiation therapy (PH). METHODS AND MATERIALS: Seventy-four patients (38 protons, 36 photons) with locally advanced non-small cell lung cancer treated with concurrent chemoradiation therapy were identified, of whom 24 exhibited RP (graded using Common Terminology Criteria for Adverse Events v4.0) after PR or PH, and 50 were negative controls. The inhale and exhale simulation computed tomography scans were deformed using Advanced Normalization Tools. The 3-dimensional lung ventilation maps were derived from the deformation matrix and partitioned into low- and high-ventilation zones for dosimetric analysis. Receiver operating curve analysis was used to study the power of relationship between RP and ventilation zones to determine an optimal ventilation cutoff. Univariate logistic regression was used to correlate dose in high- and low-ventilation zones with risk of RP. A nonparametric random forest process was used for multivariate importance assessment. RESULTS: The optimal high-ventilation zone definition was determined to be the higher 45% to 60% of the ventilation values. The parameter vV20Gy_high (high ventilation volume receiving ≥20 Gy) was found to be a significant indicator for RP (PH: P = .002, PR: P = .035) with improved areas under the curve compared with the traditional V20Gy for both photon and proton cohorts. The relationship of RP with dose to the low-ventilation zone of the lung was insignificant (PH: P = .123, PR: P = .661). Similar trends were observed for ventilation mean lung dose and ventilation V5Gy. Multivariate importance assessment determined that vV20Gy_high, vV5_high, and mean lung dose were the most significant parameters for the proton cohort with a combined area under the curve of 0.78. CONCLUSION: Dose to the high-ventilated regions of the lung can improve predictions of RP for both PH and PR.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/fisiopatologia , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/radioterapia , Terapia com Prótons/efeitos adversos , Ventilação Pulmonar/efeitos da radiação , Pneumonite por Radiação/etiologia , Idoso , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Feminino , Humanos , Masculino , Radiometria
6.
Phys Med Biol ; 64(12): 125024, 2019 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-31044743

RESUMO

The purpose of this study is to evaluate the effect of an intravenous (IV) contrast agent on proton therapy dose calculation using dual-energy computed tomography (DECT). Two DECT methods are considered. The first one, [Formula: see text], attempts to accurately predict the proton stopping powers relative to water (SPR) of contrast enhanced (CE) DECT images, while the second generates a virtual non-contrast (VNC) volume that can be processed as a native non-contrast (NC) one. Both methods are compared against single-energy computed tomography (SECT). The accuracy of SPR predicted for different concentrations of IV contrast diluted in water is first evaluated using simulated data. Results then are validated in an experimental set-up comparing SPR predictions for both NC and CE images to measurements made with a multi-layer ionisation chamber (MLIC). Finally, the impact of IV contrast on dose calculation using both SECT and DECT is evaluated for one liver and one head and neck patient. Using simulated data, DECT is shown to be less sensitive to the presence of IV contrast than SECT, although the performance of the [Formula: see text] method is sensitive to the level of beam hardening considered. For different concentrations of IV contrast diluted in water, experimental MLIC measurement of SPR agrees with DECT predictions within 3% while SECT introduce errors above 20%. This error in the SPR value results in a range error of up to 3.2 mm (2.6%) for proton beams calculated on SECT CE patient images. The error is reduced below 1 mm using DECT with the [Formula: see text] and VNC methods. Globally, it is observed that the influence of IV contrast on proton therapy dose calculation is mitigated using DECT over SECT. In patient anatomies, the VNC approach provides the best agreement with the reference dose distribution.


Assuntos
Algoritmos , Meios de Contraste , Imagens de Fantasmas , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Terapia com Prótons/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X/instrumentação
7.
Cancers (Basel) ; 10(11)2018 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-30400263

RESUMO

Background: Radiotherapy treatment planning is increasingly automated and knowledge-based planning has been shown to match and sometimes improve upon manual clinical plans, with increased consistency and efficiency. In this study, we benchmarked a novel prototype knowledge-based intensity-modulated proton therapy (IMPT) planning solution, against three international proton centers. Methods: A model library was constructed, comprising 50 head and neck cancer (HNC) manual IMPT plans from a single center. Three external-centers each provided seven manual benchmark IMPT plans. A knowledge-based plan (KBP) using a standard beam arrangement for each patient was compared with the benchmark plan on the basis of planning target volume (PTV) coverage and homogeneity and mean organ-at-risk (OAR) dose. Results: PTV coverage and homogeneity of KBPs and benchmark plans were comparable. KBP mean OAR dose was lower in 32/54, 45/48 and 38/53 OARs from center-A, -B and -C, with 23/32, 38/45 and 23/38 being >2 Gy improvements, respectively. In isolated cases the standard beam arrangement or an OAR not being included in the model or being contoured differently, led to higher individual KBP OAR doses. Generating a KBP typically required <10 min. Conclusions: A knowledge-based IMPT planning solution using a single-center model could efficiently generate plans of comparable quality to manual HNC IMPT plans from centers with differing planning aims. Occasional higher KBP OAR doses highlight the need for beam angle optimization and manual review of KBPs. The solution furthermore demonstrated the potential for robust optimization.

8.
Phys Med ; 50: 1-6, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29891088

RESUMO

PURPOSE: Passive scattering proton radiotherapy utilizes beam-specific compensators to shape the dose to the distal end of the tumor target. These compensators typically require therapists to enter the treatment room to mount between beams. This study investigates a novel approach that utilizes a single patient-specific bolus to accomplish the role of multi-field compensators to improve the efficiency of the treatment delivery. METHODS: Ray-tracing from the proton virtual source was used to convert the beam-specific compensators (mounted on the gantry nozzle) into an equivalent bolus thickness on the patient surface. The field bolus contours were combined to create a single bolus. A 3D acrylic bolus was milled for a head phantom. The dose distribution of the compensator plan was compared to the bolus plan using 3D Gamma analysis and film measurements. Boluses for two clinical patients were also designed. RESULTS: The calculated phantom dose distribution of the original proton compensator plan was shown to be equivalent to the plan with the surface bolus. Film irradiations with the proton bolus also confirmed the dosimetric equivalence of the two techniques. The dose distribution equivalency of the bolus plans for the clinical patients were demonstrated. CONCLUSIONS: We presented a novel approach that uses a single patient-specific bolus to replace patient compensators during passive scattering proton delivery. This approach has the potential to reduce the treatment time, the compensator manufacturing costs, the risk of potential collision between the compensator and the patient/couch, and the waste of compensator material.


Assuntos
Imagens de Fantasmas , Terapia com Prótons/instrumentação , Espalhamento de Radiação , Humanos , Medicina de Precisão
9.
Phys Med Biol ; 63(5): 055016, 2018 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-29513647

RESUMO

A major source of uncertainty in proton therapy is the conversion of Hounsfield unit (HU) to proton stopping power ratio relative to water (SPR). In this study, we measured and quantified the accuracy of a stoichiometric dual energy CT (DECT) SPR calibration. We applied a stoichiometric DECT calibration method to derive the SPR using CT images acquired sequentially at [Formula: see text] and [Formula: see text]. The dual energy index was derived based on the HUs of the paired spectral images and used to calculate the effective atomic number (Z eff), relative electron density ([Formula: see text]), and SPRs of phantom and biological materials. Two methods were used to verify the derived SPRs. The first method measured the sample's water equivalent thicknesses to deduce the SPRs using a multi-layer ion chamber (MLIC) device. The second method utilized Gafchromic EBT3 film to directly compare relative ranges between sample and water after proton pencil beam irradiation. Ex vivo validation was performed using five different types of frozen animal tissues with the MLIC and three types of fresh animal tissues using film. In addition, the residual ranges recorded on the film were used to compare with those from the treatment planning system using both DECT and SECT derived SPRs. Bland-Altman analysis indicates that the differences between DECT and SPR measurement of tissue surrogates, frozen and fresh animal tissues has a mean of 0.07% and standard deviation of 0.58% compared to 0.55% and 1.94% respectively for single energy CT (SECT) and SPR measurement. Our ex vivo study indicates that the stoichiometric DECT SPR calibration method has the potential to be more accurate than SECT calibration under ideal conditions although beam hardening effects and other image artifacts may increase this uncertainty.


Assuntos
Osso e Ossos/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Rim/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Imagens de Fantasmas , Prótons , Tomografia Computadorizada por Raios X/métodos , Animais , Osso e Ossos/efeitos da radiação , Encéfalo/efeitos da radiação , Calibragem , Bovinos , Rim/efeitos da radiação , Músculo Esquelético/efeitos da radiação , Suínos , Tomografia Computadorizada por Raios X/normas
10.
Phys Imaging Radiat Oncol ; 8: 17-22, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33458411

RESUMO

BACKGROUND AND PURPOSE: Photon Stereotactic Body Radiotherapy (SBRT) for primary and metastatic tumors of the liver is challenging for larger lesions. An in silico comparison of paired SBRT and Stereotactic Body Proton Therapy (SBPT) plans was performed to understand the potential advantages of SBPT as a function of tumor size and location. METHODS AND MATERIALS: Theoretical tumor volumes with maximum diameter of 1-10 cm were contoured in the dome, right inferior, left medial, and central locations. SBRT and SBPT plans were generated to deliver 50 Gy in 5 fractions, max dose <135%. When organs-at-risk (OAR) constraints were exceeded, hypothetical plans (not clinically acceptable) were generated for comparison. Liver normal tissue complication probability (NTCP) models were applied to evaluate differences between treatment modalities. RESULTS: SBRT and SBPT were able to meet target goals and OAR constraints for lesions up to 7 cm and 9 cm diameter, respectively. SBPT plans resulted in a higher integral gross target dose for all lesions up to 7 cm (mean dose 57.8 ±â€¯2.3 Gy to 64.1 ±â€¯2.2 Gy, p < 0.01). Simultaneously, SBPT spared dose to the uninvolved liver in all locations (from 11.5 ±â€¯5.3 Gy to 8.6 ±â€¯4.4 Gy, p < 0.01), resulting in lower NTCP particularly for larger targets in the dome and central locations. SBPT also spared duodenal dose across all sizes and positions (from 7.3 ±â€¯1.1 Gy to 1.1 ±â€¯0.3 Gy, p < 0.05). CONCLUSION: The main advantages of SBPT over SBRT is meeting plan goals and constrains for larger targets, particularly dome and central locations, and sparing dose to uninvolved liver. For such patients, SBPT may allow improvements in tumor control and treatment safety.

11.
Int J Radiat Oncol Biol Phys ; 99(1): 210-218, 2017 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-28816148

RESUMO

PURPOSE: To report the first clinical results and value assessment of prompt gamma imaging for in vivo proton range verification in pencil beam scanning mode. METHODS AND MATERIALS: A stand-alone, trolley-mounted, prototype prompt gamma camera utilizing a knife-edge slit collimator design was used to record the prompt gamma signal emitted along the proton tracks during delivery of proton therapy for a brain cancer patient. The recorded prompt gamma depth detection profiles of individual pencil beam spots were compared with the expected profiles simulated from the treatment plan. RESULTS: In 6 treatment fractions recorded over 3 weeks, the mean (± standard deviation) range shifts aggregated over all spots in 9 energy layers were -0.8 ± 1.3 mm for the lateral field, 1.7 ± 0.7 mm for the right-superior-oblique field, and -0.4 ± 0.9 mm for the vertex field. CONCLUSIONS: This study demonstrates the feasibility and illustrates the distinctive benefits of prompt gamma imaging in pencil beam scanning treatment mode. Accuracy in range verification was found in this first clinical case to be better than the range uncertainty margin applied in the treatment plan. These first results lay the foundation for additional work toward tighter integration of the system for in vivo proton range verification and quantification of range uncertainties.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Câmaras gama , Terapia com Prótons/métodos , Cintilografia/métodos , Fracionamento da Dose de Radiação , Desenho de Equipamento , Estudos de Viabilidade , Humanos , Cintilografia/instrumentação , Planejamento da Radioterapia Assistida por Computador
12.
Radiother Oncol ; 120(3): 532-536, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27247058

RESUMO

BACKGROUND AND PURPOSE: To quantify intra-treatment vaginal motion in women treated with daily endorectal balloon (ERB) placement and external beam radiotherapy for gynecologic cancers. MATERIALS AND METHODS: Eighteen post-hysterectomy women with gynecologic cancers underwent computed tomography (CT) simulation scans and daily treatment with ERB. Fiducial markers were placed at the vaginal apex prior to simulation and patients were counseled on a pre-treatment bladder filling protocol. Weekly to biweekly verification CT scans were used to calculate the intra-treatment change in bladder volumes, rectal volumes, and fiducial coordinates along all axes. The planning target volume (PTV) margins required to encompass 95% of intra-treatment fiducial movement were calculated using the van Herk margin recipe. RESULTS: The median bladder volume was 223 (range, 29-879)cc for verification CT scans. Mean intra-treatment fiducial displacements were 1.7 (range, 0-9.1)mm, 2.9 (range, 0-15.5)mm, and 2.5 (range, 0-11.8)mm along the left-right (L/R), superior-inferior (S/I), and anterior-posterior (A/P) axes, respectively. The van Herk PTV margins were 3mm (L/R), 10mm (S/I) and 7mm (A/P). CONCLUSION: When compared to existing studies, the use of daily ERB with post-hysterectomy radiotherapy reduces vaginal motion along the A/P axis. The impact of variable bladder filling on vaginal motion is most evident along the S/I axis.


Assuntos
Neoplasias dos Genitais Femininos/radioterapia , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Vagina/fisiopatologia , Adulto , Idoso , Feminino , Marcadores Fiduciais , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Humanos , Histerectomia , Imobilização , Pessoa de Meia-Idade , Movimento , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/patologia , Bexiga Urinária/fisiopatologia , Adulto Jovem
13.
Acta Oncol ; 55(7): 828-33, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27145164

RESUMO

PURPOSE/OBJECTIVES: To optimize delivery of post-prostatectomy radiation (PPRT) with protons by examining dosimetric effects of variations in physician contouring, organ motion, and patient alignment during a course of PPRT. MATERIAL AND METHODS: We enrolled 10 patients receiving PPRT in a prospective imaging study. All patients underwent combined computed tomography (CT)/magnetic resonance imaging (MRI) simulation with endorectal balloon (ERB) and received intensity modulated radiation therapy (IMRT) per institutional standards. Study patients underwent weekly MRI verification scans in the treatment position. Three radiation oncologists contoured clinical target volumes (CTV) on initial and verification scans using two consensus guidelines (RTOG and EORTC). We generated IMRT, double scattering (DS), and pencil beam scanning (PBS) proton plans and examined the dosimetric impact of contour variations, inter-fraction motion, and patient alignment techniques. RESULTS: Inter-observer variations in contouring reduced median CTV coverage (D100) by 0.9% for IMRT plans, 2.8% for DS proton plans, 3.4-4.9% for PBS Proton Plans. Inter-fraction changes in target volumes due to internal organ motion resulted in a median loss of target dose coverage (D98) of 0% with IMRT, 3.5% with DS, and 8.1-8.3% with PBS. Median bladder V65Gy increased during the treatment course with all techniques (6.0-7.5%). Changes in the median rectal V60Gy remained small regardless of the treatment technique (0.5-3.1% increase). Alignment to the ERB after cranio-caudal bony alignment reduced CTV displacement compared to bony alignment alone, and as a result CTV coverage (D98) changed <2% with IMRT, DS, and PBS. CONCLUSION: Proton-based treatments are more sensitive to changes in inter-fraction organ motion during PPRT compared to IMRT, and therefore motion management and patient alignment methods are critical. Patient alignment using bony anatomy as well as the ERB minimizes displacement of the CTV, and reduces variation in target dose coverage particularly for PBS proton therapy.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/radioterapia , Adenocarcinoma/cirurgia , Humanos , Masculino , Variações Dependentes do Observador , Órgãos em Risco , Cuidados Pós-Operatórios/métodos , Estudos Prospectivos , Prostatectomia , Neoplasias da Próstata/cirurgia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Reto/efeitos da radiação , Tomografia Computadorizada por Raios X/métodos , Bexiga Urinária/efeitos da radiação
14.
Int J Radiat Oncol Biol Phys ; 95(1): 549-559, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27084664

RESUMO

PURPOSE: An adaptive proton therapy workflow using cone beam computed tomography (CBCT) is proposed. It consists of an online evaluation of a fast range-corrected dose distribution based on a virtual CT (vCT) scan. This can be followed by more accurate offline dose recalculation on the vCT scan, which can trigger a rescan CT (rCT) for replanning. METHODS AND MATERIALS: The workflow was tested retrospectively for 20 consecutive lung cancer patients. A diffeomorphic Morphon algorithm was used to generate the lung vCT by deforming the average planning CT onto the CBCT scan. An additional correction step was applied to account for anatomic modifications that cannot be modeled by deformation alone. A set of clinical indicators for replanning were generated according to the water equivalent thickness (WET) and dose statistics and compared with those obtained on the rCT scan. The fast dose approximation consisted of warping the initial planned dose onto the vCT scan according to the changes in WET. The potential under- and over-ranges were assessed as a variation in WET at the target's distal surface. RESULTS: The range-corrected dose from the vCT scan reproduced clinical indicators similar to those of the rCT scan. The workflow performed well under different clinical scenarios, including atelectasis, lung reinflation, and different types of tumor response. Between the vCT and rCT scans, we found a difference in the measured 95% percentile of the over-range distribution of 3.4 ± 2.7 mm. The limitations of the technique consisted of inherent uncertainties in deformable registration and the drawbacks of CBCT imaging. The correction step was adequate when gross errors occurred but could not recover subtle anatomic or density changes in tumors with complex topology. CONCLUSIONS: A proton therapy workflow based on CBCT provided clinical indicators similar to those using rCT for patients with lung cancer with considerable anatomic changes.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Água Corporal/diagnóstico por imagem , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/efeitos da radiação , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Estudos Retrospectivos
15.
J Appl Clin Med Phys ; 17(2): 427-440, 2016 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-27074464

RESUMO

The aim of this work is to demonstrate the feasibility of using water-equivalent thickness (WET) and virtual proton depth radiographs (PDRs) of intensity corrected cone-beam computed tomography (CBCT) to detect anatomical change and patient setup error to trigger adaptive head and neck proton therapy. The planning CT (pCT) and linear accelerator (linac) equipped CBCTs acquired weekly during treatment of a head and neck patient were used in this study. Deformable image registration (DIR) was used to register each CBCT with the pCT and map Hounsfield units (HUs) from the planning CT (pCT) onto the daily CBCT. The deformed pCT is referred as the corrected CBCT (cCBCT). Two dimensional virtual lateral PDRs were generated using a ray-tracing technique to project the cumulative WET from a virtual source through the cCBCT and the pCT onto a virtual plane. The PDRs were used to identify anatomic regions with large variations in the proton range between the cCBCT and pCT using a threshold of 3 mm relative difference of WET and 3 mm search radius criteria. The relationship between PDR differences and dose distribution is established. Due to weight change and tumor response during treatment, large variations in WETs were observed in the relative PDRs which corresponded spatially with an increase in the number of failing points within the GTV, especially in the pharynx area. Failing points were also evident near the posterior neck due to setup variations. Differences in PDRs correlated spatially to differences in the distal dose distribution in the beam's eye view. Virtual PDRs generated from volumetric data, such as pCTs or CBCTs, are potentially a useful quantitative tool in proton therapy. PDRs and WET analysis may be used to detect anatomical change from baseline during treatment and trigger further analysis in adaptive proton therapy.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Processamento de Imagem Assistida por Computador/métodos , Terapia com Prótons , Água/química , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Estadiamento de Neoplasias , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
16.
J Appl Clin Med Phys ; 16(3): 4959, 2015 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-26103473

RESUMO

In electron and proton radiotherapy, applications of patient-specific electron bolus or proton compensators during radiation treatments are often necessary to accommodate patient body surface irregularities, tissue inhomogeneity, and variations in PTV depths to achieve desired dose distributions. Emerging 3D printing technologies provide alternative fabrication methods for these bolus and compensators. This study investigated the potential of utilizing 3D printing technologies for the fabrication of the electron bolus and proton compensators. Two printing technologies, fused deposition modeling (FDM) and selective laser sintering (SLS), and two printing materials, PLA and polyamide, were investigated. Samples were printed and characterized with CT scan and under electron and proton beams. In addition, a software package was developed to convert electron bolus and proton compensator designs to printable Standard Tessellation Language file format. A phantom scalp electron bolus was printed with FDM technology with PLA material. The HU of the printed electron bolus was 106.5 ± 15.2. A prostate patient proton compensator was printed with SLS technology and polyamide material with -70.1 ± 8.1 HU. The profiles of the electron bolus and proton compensator were compared with the original designs. The average over all the CT slices of the largest Euclidean distance between the design and the fabricated bolus on each CT slice was found to be 0.84 ± 0.45 mm and for the compensator to be 0.40 ± 0.42 mm. It is recommended that the properties of specific 3D printed objects are understood before being applied to radiotherapy treatments.


Assuntos
Elétrons , Impressão Tridimensional/instrumentação , Prótons , Radioterapia Conformacional/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Espalhamento de Radiação
17.
Int J Radiat Oncol Biol Phys ; 91(5): 1034-40, 2015 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-25832694

RESUMO

PURPOSE: To compare the extent of tumor motion between 4-dimensional CT (4DCT) and cine-MRI in patients with hepatic tumors treated with radiation therapy. METHODS AND MATERIALS: Patients with liver tumors who underwent 4DCT and 2-dimensional biplanar cine-MRI scans during simulation were retrospectively reviewed to determine the extent of target motion in the superior-inferior, anterior-posterior, and lateral directions. Cine-MRI was performed over 5 minutes. Tumor motion from MRI was determined by tracking the centroid of the gross tumor volume using deformable image registration. Motion estimates from 4DCT were performed by evaluation of the fiducial, residual contrast (or liver contour) positions in each CT phase. RESULTS: Sixteen patients with hepatocellular carcinoma (n=11), cholangiocarcinoma (n=3), and liver metastasis (n=2) were reviewed. Cine-MRI motion was larger than 4DCT for the superior-inferior direction in 50% of patients by a median of 3.0 mm (range, 1.5-7 mm), the anterior-posterior direction in 44% of patients by a median of 2.5 mm (range, 1-5.5 mm), and laterally in 63% of patients by a median of 1.1 mm (range, 0.2-4.5 mm). CONCLUSIONS: Cine-MRI frequently detects larger differences in hepatic intrafraction tumor motion when compared with 4DCT most notably in the superior-inferior direction, and may be useful when assessing the need for or treating without respiratory management, particularly in patients with unreliable 4DCT imaging. Margins wider than the internal target volume as defined by 4DCT were required to encompass nearly all the motion detected by cine-MRI for some of the patients in this study.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Colangiocarcinoma/diagnóstico , Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Hepáticas/diagnóstico , Fígado , Imagem Cinética por Ressonância Magnética/métodos , Movimento , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Colangiocarcinoma/diagnóstico por imagem , Colangiocarcinoma/patologia , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Carga Tumoral
18.
Radiat Oncol ; 9: 225, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-25365935

RESUMO

BACKGROUND: Intensity modulated arc therapy (IMAT) has been widely adopted for Stereotactic Body Radiotherapy (SBRT) for lung cancer. While treatment dose is optimized and calculated on a static Computed Tomography (CT) image, the effect of the interplay between the target and linac multi-leaf collimator (MLC) motion is not well described and may result in deviations between delivered and planned dose. In this study, we investigated the dosimetric consequences of the inter-play effect on target and organs at risk (OAR) by simulating dynamic dose delivery using dynamic CT datasets. METHODS: Fifteen stage I non-small cell lung cancer (NSCLC) patients with greater than 10 mm tumor motion treated with SBRT in 4 fractions to a dose of 50 Gy were retrospectively analyzed for this study. Each IMAT plan was initially optimized using two arcs. Simulated dynamic delivery was performed by associating the MLC leaf position, gantry angle and delivered beam monitor units (MUs) for each control point with different respiratory phases of the 4D-CT using machine delivery log files containing time stamps of the control points. Dose maps associated with each phase of the 4D-CT dose were calculated in the treatment planning system and accumulated using deformable image registration onto the exhale phase of the 4D-CT. The original IMAT plans were recalculated on the exhale phase of the CT for comparison with the dynamic simulation. RESULTS: The dose coverage of the PTV showed negligible variation between the static and dynamic simulation. There was less than 1.5% difference in PTV V95% and V90%. The average inter-fraction and cumulative dosimetric effects among all the patients were less than 0.5% for PTV V95% and V90% coverage and 0.8 Gy for the OARs. However, in patients where target is close to the organs, large variations were observed on great vessels and bronchus for as much as 4.9 Gy and 7.8 Gy. CONCLUSIONS: Limited variation in target dose coverage and OAR constraints were seen for each SBRT fraction as well as over all four fractions. Large dose variations were observed on critical organs in patients where these organs were closer to the target.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/cirurgia , Neoplasias Pulmonares/cirurgia , Movimento (Física) , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Carcinoma Pulmonar de Células não Pequenas/patologia , Tomografia Computadorizada Quadridimensional , Humanos , Pulmão/fisiologia , Neoplasias Pulmonares/patologia , Órgãos em Risco , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Respiração , Estudos Retrospectivos
19.
Med Dosim ; 39(2): 139-45, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24661778

RESUMO

With traditional photon therapy to treat large postoperative pancreatic target volume, it often leads to poor tolerance of the therapy delivered and may contribute to interrupted treatment course. This study was performed to evaluate the potential advantage of using passive-scattering (PS) and modulated-scanning (MS) proton therapy (PT) to reduce normal tissue exposure in postoperative pancreatic cancer treatment. A total of 11 patients with postoperative pancreatic cancer who had been previously treated with PS PT in University of Pennsylvania Roberts Proton Therapy Center from 2010 to 2013 were identified. The clinical target volume (CTV) includes the pancreatic tumor bed as well as the adjacent high-risk nodal areas. Internal (iCTV) was generated from 4-dimensional (4D) computed tomography (CT), taking into account target motion from breathing cycle. Three-field and 4-field 3D conformal radiation therapy (3DCRT), 5-field intensity-modulated radiation therapy, 2-arc volumetric-modulated radiation therapy, and 2-field PS and MS PT were created on the patients' average CT. All the plans delivered 50.4Gy to the planning target volume (PTV). Overall, 98% of PTV was covered by 95% of the prescription dose and 99% of iCTV received 98% prescription dose. The results show that all the proton plans offer significant lower doses to the left kidney (mean and V18Gy), stomach (mean and V20Gy), and cord (maximum dose) compared with all the photon plans, except 3-field 3DCRT in cord maximum dose. In addition, MS PT also provides lower doses to the right kidney (mean and V18Gy), liver (mean dose), total bowel (V20Gy and mean dose), and small bowel (V15Gy absolute volume ratio) compared with all the photon plans and PS PT. The dosimetric advantage of PT points to the possibility of treating tumor bed and comprehensive nodal areas while providing a more tolerable treatment course that could be used for dose escalation and combining with radiosensitizing chemotherapy.


Assuntos
Neoplasias Pancreáticas/radioterapia , Terapia com Prótons/métodos , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/métodos , Humanos , Neoplasias Pancreáticas/cirurgia , Estudos Retrospectivos
20.
J Appl Clin Med Phys ; 14(3): 4138, 2013 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-23652247

RESUMO

One of the main components in a Calypso 4D localization and tracking system is an electromagnetic array placed above patients that is used for target monitoring during radiation treatment. The beam attenuation and beam spoiling properties of the Calypso electromagnetic array at various beam angles were investigated. Measurements were performed on a Varian Clinac iX linear accelerator with 6 MV and 15 MV photon beams. The narrow beam attenuation properties were measured under a field size of 1 cm × 1 cm, with a photon diode placed in a cylindrical graphite buildup cap. The broad beam attenuation properties were measured under a field size of 10 cm × 10 cm, with a 0.6 cc cylindrical Farmer chamber placed in a polystyrene buildup cap. Beam spoiling properties of the array were studied by measuring depth-dose change from the array under a field size of 10 cm × 10 cm in a water-equivalent plastic phantom with an embedded Markus parallel plate chamber. Change in depth doses were measured with the array placed at distances of 2, 5, and 10 cm from the phantom surface. Narrow beam attenuation and broad beam attenuation from the array were found to be less than 2%-3% for both 6 MV and 15 MV beams at angles less than 40°, and were more pronounced at more oblique angles. Spoiling effects are appreciable at beam buildup region, but are insignificant at depths beyond dmax. Dose measurements in a QA phantom using patient IMRT and VMAT treatment plans were shown to have less than 2.5% dose difference with the Calypso array. The results indicate that the dose difference due to the placement of Calypso array is clinically insignificant.


Assuntos
Fenômenos Eletromagnéticos , Neoplasias/patologia , Neoplasias/radioterapia , Fótons , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica