Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev. esp. cardiol. (Ed. impr.) ; 75(10): 787-797, oct. 2022. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-211050

RESUMO

Introducción y objetivos El índice de resistencia microcirculatoria (IRM) medido tras una angioplastia primaria (ICPp) por infarto agudo de miocardio con elevación del segmento ST (IAMCEST) se asocia con la aparición de obstrucción microvascular (OMV) y eventos clínicos adversos. Para evaluar la OMV tras una ICPp exitosa por IAMCEST sin guías de presión ni administración de agentes hiperémicos, variables que parecen limitar la adopción del IRM en el laboratorio de hemodinámica, se investiga la viabilidad y la utilidad de la medición del IRM mediante resonancia magnética cardiaca (RMC) (angio-IRM). Métodos El estudio incluyó a 285 pacientes con IAMCEST sometidos a ICPp y RMC. Con un programa informático comercial, se calculó el angio-IRM del vaso culpable tras la ICPp exitosa. Se evaluaron la OMV, el tamaño del infarto y el índice de rescate miocárdico medidos una mediana de 3 [rango intercuartílico, 3-5] días después de la ICPp. Resultados De la población total, 154 pacientes (54,0%) mostraron valores de angio-IRM elevados (> 40 U) en el vaso culpable. La OMV fue significativamente más frecuente en los pacientes con angio-IRM> 40 U que en aquellos con angio-IRM ≤ 40 U (el 88,3 frente al 32,1%; p <0,001). El tamaño del infarto, la extensión de la OMV y el área en riesgo fueron significativamente mayores en los pacientes con angio-IRM> 40 U que con angio-IRM ≤ 40 U (p <0,001 para todas las comparaciones). El angio-IRM mostró una capacidad de discriminación de OMV significativamente mayor que el grado de flujo TIMI o de blush miocárdico (área bajo la curva, 0,821, 0,504 y 0,496 respectivamente; p <0,001). Conclusiones El angio-IRM se asoció significativamente con el tamaño del infarto, la extensión de la OMV y el área en riesgo. Cifras altas del angio-IRM (> 40 U) tras una ICPp por IAMCEST fueron muy predictivas de OMV en la RMC (AU)


Introduction and objectives The index of microcirculatory resistance (IMR) measured after primary percutaneous coronary intervention (PCI) for ST-segment elevation myocardial infarction (STEMI) is associated with microvascular obstruction (MVO) and adverse clinical events. To evaluate MVO after successful primary PCI for STEMI without pressure wires or hyperemic agents, we investigated the feasibility and usefulness of functional angiography-derived IMR (angio-IMR). Methods The current study included a total of 285 STEMI patients who underwent primary PCI and cardiac magnetic resonance (CMR). Angio-IMR of the culprit vessel after successful primary PCI was calculated using commercial software. MVO, infarct size, and myocardial salvage index were assessed using CMR, which was obtained a median of 3.0 days [interquartile range, 3.0-5.0] after primary PCI. Results Among the total population, 154 patients (54.0%) showed elevated angio-IMR (> 40 U) in the culprit vessel. MVO was significantly more prevalent in patients with angio-IMR> 40 U than in those with angio-IMR ≤ 40 U (88.3% vs 32.1%, P <.001). Infarct size, extent of MVO, and area at risk were significantly larger in patients with angio-IMR> 40 U than in those with angio-IMR ≤ 40 U (P <.001 for all). Angio-IMR showed a significantly higher discriminatory ability for the presence of MVO than thrombolysis in myocardial infarction flow grade or myocardial blush grade (area under the curve: 0.821, 0.504, and 0.496, respectively, P <.001). Conclusions Angio-IMR was significantly associated with CMR-derived infarct size, extent of MVO, and area at risk. An elevated angio-IMR (> 40 U) after primary PCI for STEMI was highly predictive of the presence of MVO in CMR (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Imageamento por Ressonância Magnética , Estudos Prospectivos , Circulação Coronária , Angiografia
2.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-334109

RESUMO

<p><b>OBJECTIVE</b>To compare the results of femoral head replacement (FHR) and total hip replacement (THR) in treatment of subcapital femoral neck fractures (SFNF).</p><p><b>METHODS</b>Between May 1987 and July 1998, 56 elderly patients (6 5-90 years; average 73.5 years) with SFNF were treated with prosthetic replacement. Six cases were treated with unipolar FHR, 18 cases with Bateman bipolar FHR, and 32 cases with Bateman bipolar THR. All domestic prostheses were installed with cement.</p><p><b>RESULTS</b>There was no significant difference between the 2 groups in operating time and blood transfusion. Forty-nine patients were followed-up for an average of 5 years and 10 months. No wound infection or death was related to surgery. Complications in Group FHR were significantly higher than that i n Group THR.</p><p><b>CONCLUSIONS</b>Since FHR is difficult to fit the bony acetabulum, it is only indicated for senile cases with poor conditions. However, the bi polar THR installed with cement is indicated for most elderly patients. Since th e femoral head and acetabulum can fit each other completely, it is more stable for taking weight-bearing earlier with less complications.</p>


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Artroplastia de Quadril , Cimentos Ósseos , Fraturas do Colo Femoral , Diagnóstico por Imagem , Cirurgia Geral , Prótese de Quadril , Radiografia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...