Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Mater ; 19(4)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38697199

RESUMO

Porous tantalum scaffolds offer a high degree of biocompatibility and have a low friction coefficient. In addition, their biomimetic porous structure and mechanical properties, which closely resemble human bone tissue, make them a popular area of research in the field of bone defect repair. With the rapid advancement of additive manufacturing, 3D-printed porous tantalum scaffolds have increasingly emerged in recent years, offering exceptional design flexibility, as well as facilitating the fabrication of intricate geometries and complex pore structures that similar to human anatomy. This review provides a comprehensive description of the techniques, procedures, and specific parameters involved in the 3D printing of porous tantalum scaffolds. Concurrently, the review provides a summary of the mechanical properties, osteogenesis and antibacterial properties of porous tantalum scaffolds. The use of surface modification techniques and the drug carriers can enhance the characteristics of porous tantalum scaffolds. Accordingly, the review discusses the application of these porous tantalum materials in clinical settings. Multiple studies have demonstrated that 3D-printed porous tantalum scaffolds exhibit exceptional corrosion resistance, biocompatibility, and osteogenic properties. As a result, they are considered highly suitable biomaterials for repairing bone defects. Despite the rapid development of 3D-printed porous tantalum scaffolds, they still encounter challenges and issues when used as bone defect implants in clinical applications. Ultimately, a concise overview of the primary challenges faced by 3D-printed porous tantalum scaffolds is offered, and corresponding insights to promote further exploration and advancement in this domain are presented.


Assuntos
Materiais Biocompatíveis , Substitutos Ósseos , Osso e Ossos , Osteogênese , Impressão Tridimensional , Tantálio , Engenharia Tecidual , Alicerces Teciduais , Tantálio/química , Alicerces Teciduais/química , Porosidade , Humanos , Materiais Biocompatíveis/química , Engenharia Tecidual/métodos , Animais , Substitutos Ósseos/química , Teste de Materiais , Regeneração Óssea
2.
Front Bioeng Biotechnol ; 11: 1219745, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37790252

RESUMO

Objective: This study aimed to evaluate the biomechanical effectiveness of 3D-printed integrated acetabular prosthesis (IAP) and modular acetabular prosthesis (MAP) in reconstructing the acetabulum for patients with Crowe III developmental dysplasia of the hip (DDH). The results of this study can provide a theoretical foundation for the treatment of Crowe III DDH in total hip arthroplasty (THA). Methods: Finite element (FE) analysis models were created to reconstruct Crowe III DDH acetabular defects using IAP and MAP. The contact stress and relative micromotion between the acetabular prosthesis and the host bone were analyzed by gradually loading in three increments (210 N, 2100 N, and 4200 N). In addition, five patients with Crowe III DDH who underwent IAP acetabular reconstruction were observed. Results: At the same load, the peak values of IAP contact stress and relative micromotion were lower than those of MAP acetabular reconstruction. Under jogging load, the MAP metal augment's peak stress exceeded porous tantalum yield strength, and the risk of prosthesis fracture was higher. The peak stress in the bone interface in contact with the MAP during walking and jogging was higher than that in the cancellous bone, while that of IAP was higher than that of the cancellous bone only under jogging load, so the risk of MAP cancellous bone failure was greater. Under jogging load, the relative micromotion of the MAP reconstruction acetabular implant was 45.2 µm, which was not conducive to bone growth, while under three different loads, the relative micromotion of the IAP acetabular implant was 1.5-11.2 µm, all <40 µm, which was beneficial to bone growth. Five patients with IAP acetabular reconstruction were followed up for 11.8 ± 3.4 months, and the Harris score of the last follow-up was 85.4 ± 5.5. The imaging results showed good stability of all prostheses with no adverse conditions observed. Conclusion: Compared with acetabular reconstruction with MAP, IAP has a lower risk of loosening and fracture, as well as a better long-term stability. The application of IAP is an ideal acetabular reconstruction method for Crowe III DDH.

3.
Transplantation ; 107(12): e328-e338, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37643028

RESUMO

BACKGROUND: Orthotopic cardiac xenotransplantation has seen substantial advancement in the last years and the initiation of a clinical pilot study is close. However, donor organ overgrowth has been a major hurdle for preclinical experiments, resulting in loss of function and the decease of the recipient. A better understanding of the pathogenesis of organ overgrowth after xenotransplantation is necessary before clinical application. METHODS: Hearts from genetically modified ( GGTA1-KO , hCD46/hTBM transgenic) juvenile pigs were orthotopically transplanted into male baboons. Group I (control, n = 3) received immunosuppression based on costimulation blockade, group II (growth inhibition, n = 9) was additionally treated with mechanistic target of rapamycin inhibitor, antihypertensive medication, and fast corticoid tapering. Thyroid hormones and insulin-like growth factor 1 were measured before transplantation and before euthanasia, left ventricular (LV) growth was assessed by echocardiography, and hemodynamic data were recorded via a wireless implant. RESULTS: Insulin-like growth factor 1 was higher in baboons than in donor piglets but dropped to porcine levels at the end of the experiments in group I. LV mass increase was 10-fold faster in group I than in group II. This increase was caused by nonphysiological LV wall enlargement. Additionally, pressure gradients between LV and the ascending aorta developed, and signs of dynamic left ventricular outflow tract (LVOT) obstruction appeared. CONCLUSIONS: After orthotopic xenotransplantation in baboon recipients, untreated porcine hearts showed rapidly progressing concentric hypertrophy with dynamic LVOT obstruction, mimicking hypertrophic obstructive cardiomyopathy in humans. Antihypertensive and antiproliferative drugs reduced growth rate and inhibited LVOT obstruction, thereby preventing loss of function.


Assuntos
Transplante de Coração , Obstrução da Via de Saída Ventricular Esquerda , Humanos , Animais , Masculino , Suínos , Xenoenxertos , Transplante Heterólogo/métodos , Papio , Fator de Crescimento Insulin-Like I , Anti-Hipertensivos , Projetos Piloto , Hipertrofia Ventricular Esquerda , Transplante de Coração/efeitos adversos , Transplante de Coração/métodos
4.
Orthop Surg ; 15(5): 1264-1271, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36896785

RESUMO

OBJECTIVE: The treatment of acetabular defects is one of the most difficult challenges of revision of total hip arthroplasty (RTHA), and tantalum is regarded as a promising bone substitute material. This study aims to investigate the effectiveness of 3D printed acetabular augment used in RTHA for the treatment of acetabular bone defect. METHODS: A retrospective analysis of the clinical data of seven patients who had undergone RTHA was carried out using 3D printed acetabular augment from January 2017 to December 2018. The CT data of the patients were exported to Mimics 21.0 software (Materialise, Leuven, Belgium), and the acetabular bone defect augment were designed, printed and then implanted during operation. The postoperative Harris score, visual analogue scale (VAS) score and prosthesis position were observed to evaluate the clinical outcome. A I-test was used for preoperative and postoperative comparison of the paired-design dataset. RESULTS: A firm attachment of the bone augment to the acetabulum during operation without any complications was found during the follow-up time 2.8-4.3 years. The VAS score of all patients was found 6.9 ± 1.4 before operation and was 0.7 ± 0.7 at the last follow-up (P ≤ 0.001), and the Harris hip scores, were 31.9 ± 10.3 and 73.3 ± 12.8 before operation, and at the last follow-up (P ≤ 0.001), respectively. Moreover, no loosening sign between the bone defect augment and the acetabulum was observed during the entire implantation period. CONCLUSION: 3D printed acetabular augment is effective in reconstructing the acetabulum following an acetabular bone defect revision, which enhances the hip joint function and eventually makes a satisfactory stable prosthetic.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Acetábulo/cirurgia , Tantálio , Estudos Retrospectivos , Reoperação , Impressão Tridimensional , Falha de Prótese , Seguimentos , Resultado do Tratamento
5.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 37(3): 353-359, 2023 Mar 15.
Artigo em Chinês | MEDLINE | ID: mdl-36940996

RESUMO

Objective: To summarize the characteristics and biomechanical research progress of common acetabular reconstruction techniques in patients with Crowe type Ⅱ and Ⅲ developmental dysplasia of the hip (DDH) undergoing total hip arthroplasty (THA), and provide references for selecting appropriate acetabular reconstruction techniques for clinical treatment of Crowe type Ⅱ and Ⅲ DDH. Methods: The domestic and foreign relevant literature on biomechanics of acetabular reconstruction with Crowe type Ⅱ and Ⅲ DDH was reviewed, and the research progress was summarized. Results: At present, there are many acetabular reconstruction techniques in Crowe type Ⅱ and Ⅲ DDH patients undergoing THA, with their own characteristics due to structural and biomechanical differences. The acetabular roof reconstruction technique enables the acetabular cup prosthesis to obtain satisfactory initial stability, increases the acetabular bone reserve, and provides a bone mass basis for the possible secondary revision. The medial protrusio technique (MPT) reduces the stress in the weight-bearing area of the hip joint and the wear of the prosthesis, and increases the service life of the prosthesis. Small acetabulum cup technique enables shallow small acetabulum to match suitable acetabulum cup to obtain ideal cup coverage, but small acetabulum cup also increases the stress per unit area of acetabulum cup, which is not conducive to the long-term effectiveness. The rotation center up-shifting technique increases the initial stability of the cup. Conclusion: Currently, there is no detailed standard guidance for the selection of acetabular reconstruction in THA with Crowe type Ⅱ and Ⅲ DDH, and the appropriate acetabular reconstruction technique should be selected according to the different types of DDH.


Assuntos
Artroplastia de Quadril , Displasia do Desenvolvimento do Quadril , Luxação Congênita de Quadril , Prótese de Quadril , Humanos , Acetábulo/cirurgia , Luxação Congênita de Quadril/cirurgia , Displasia do Desenvolvimento do Quadril/complicações , Displasia do Desenvolvimento do Quadril/cirurgia , Articulação do Quadril/cirurgia , Artroplastia de Quadril/métodos , Resultado do Tratamento , Estudos Retrospectivos
6.
Biomater Transl ; 4(3): 166-179, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38283089

RESUMO

With continuous developments in additive manufacturing technology, tantalum (Ta) metal has been manufactured into orthopaedic implants with a variety of forms, properties and uses by three-dimensional printing. Based on extensive research in recent years, the design, processing and performance aspects of this new orthopaedic implant material have been greatly improved. Besides the bionic porous structure and mechanical characteristics that are similar to human bone tissue, porous tantalum is considered to be a viable bone repair material due to its outstanding corrosion resistance, biocompatibility, bone integration and bone conductivity. Numerous in vitro, in vivo, and clinical studies have been carried out in order to analyse the safety and efficacy of these implants in orthopaedic applications. This study reviews the most recent advances in manufacturing, characteristics and clinical application of porous tantalum materials.

7.
Xenotransplantation ; 28(1): e12636, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32841431

RESUMO

BACKGROUND: Successful preclinical transplantations of porcine hearts into baboon recipients are required before commencing clinical trials. Despite years of research, over half of the orthotopic cardiac xenografts were lost during the first 48 hours after transplantation, primarily caused by perioperative cardiac xenograft dysfunction (PCXD). To decrease the rate of PCXD, we adopted a preservation technique of cold non-ischemic perfusion for our ongoing pig-to-baboon cardiac xenotransplantation project. METHODS: Fourteen orthotopic cardiac xenotransplantation experiments were carried out with genetically modified juvenile pigs (GGTA1- KO/hCD46/hTBM) as donors and captive-bred baboons as recipients. Organ preservation was compared according to the two techniques applied: cold static ischemic cardioplegia (IC; n = 5) and cold non-ischemic continuous perfusion (CP; n = 9) with an oxygenated albumin-containing hyperoncotic cardioplegic solution containing nutrients, erythrocytes and hormones. Prior to surgery, we measured serum levels of preformed anti-non-Gal-antibodies. During surgery, hemodynamic parameters were monitored with transpulmonary thermodilution. Central venous blood gas analyses were taken at regular intervals to estimate oxygen extraction, as well as lactate production. After surgery, we measured troponine T and serum parameters of the recipient's kidney, liver and coagulation functions. RESULTS: In porcine grafts preserved with IC, we found significantly depressed systolic cardiac function after transplantation which did not recover despite increasing inotropic support. Postoperative oxygen extraction and lactate production were significantly increased. Troponin T, creatinine, aspartate aminotransferase levels were pathologically high, whereas prothrombin ratios were abnormally low. In three of five IC experiments, PCXD developed within 24 hours. By contrast, all nine hearts preserved with CP retained fully preserved systolic function, none showed any signs of PCXD. Oxygen extraction was within normal ranges; serum lactate as well as parameters of organ functions were only mildly elevated. Preformed anti-non-Gal-antibodies were similar in recipients receiving grafts from either IC or CP preservation. CONCLUSIONS: While standard ischemic cardioplegia solutions have been used with great success in human allotransplantation over many years, our data indicate that they are insufficient for preservation of porcine hearts transplanted into baboons: Ischemic storage caused severe impairment of cardiac function and decreased tissue oxygen supply, leading to multi-organ failure in more than half of the xenotransplantation experiments. In contrast, cold non-ischemic heart preservation with continuous perfusion reliably prevented early graft failure. Consistent survival in the perioperative phase is a prerequisite for preclinical long-term results after cardiac xenotransplantation.


Assuntos
Transplante de Coração , Animais , Xenoenxertos , Papio , Perfusão , Suínos , Transplante Heterólogo
8.
J Heart Lung Transplant ; 39(8): 751-757, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32527674

RESUMO

BACKGROUND: The demand for donated human hearts far exceeds the number available. Xenotransplantation of genetically modified porcine organs provides an alternative. In 2000, an Advisory Board of the International Society for Heart and Lung Transplantation set the benchmark for commencing clinical cardiac xenotransplantation as consistent 60% survival of non-human primates after life-supporting porcine heart transplantations. Recently, we reported the stepwise optimization of pig-to-baboon orthotopic cardiac xenotransplantation finally resulting in consistent success, with 4 recipients surviving 90 (n = 2), 182, and 195 days. Here, we report on 4 additional recipients, supporting the efficacy of our procedure. RESULTS: The first 2 additional recipients succumbed to porcine cytomegalovirus (PCMV) infections on Days 15 and 27, respectively. In 2 further experiments, PCMV infections were successfully avoided, and 3-months survival was achieved. Throughout all the long-term experiments, heart, liver, and renal functions remained within normal ranges. Post-mortem cardiac diameters were slightly increased when compared with that at the time of transplantation but with no detrimental effect. There were no signs of thrombotic microangiopathy. The current regimen enabled the prolonged survival and function of orthotopic cardiac xenografts in altogether 6 of 8 baboons, of which 4 were now added. These results exceed the threshold set by the Advisory Board of the International Society for Heart and Lung Transplantation. CONCLUSIONS: The results of our current and previous experimental cardiac xenotransplantations together fulfill for the first time the pre-clinical efficacy suggestions. PCMV-positive donor animals must be avoided.


Assuntos
Rejeição de Enxerto/etiologia , Transplante de Coração/métodos , Doadores de Tecidos , Animais , Sobrevivência de Enxerto , Humanos , Suínos , Transplante Heterólogo
9.
Zhongguo Zhen Jiu ; 40(12): 1338-42, 2020 Dec 12.
Artigo em Chinês | MEDLINE | ID: mdl-33415879

RESUMO

Professor ZHANG Ren's clinical experience of acupuncture for glaucoma is summarized. Professor ZHANG believes that key pathogenesis of glaucoma is stagnation of qi and blood in the eyes, obstruction of xuanfu in the eyes, and obstruction of meridians. The treatment should focus on the eye, with smoothing the liver and keeping functional state of six-fu as priority; he also emphasizes the acupoint selection based on the combination of disease differentiation and syndrome differentiation, and pays attention to the application of acupuncture method of promoting qi circulation and inducting qi movement. Professor ZHANG proposes that the patients should be treated according to different types, and stresses the importance of using comprehensive treatment and emotional adjustment method, as well as early intervention, long-term adherence and regular treatment.


Assuntos
Terapia por Acupuntura , Glaucoma , Meridianos , Pontos de Acupuntura , Glaucoma/terapia , Humanos , Masculino , Síndrome
10.
Zhongguo Zhen Jiu ; 39(4): 445-50, 2019 Apr 12.
Artigo em Chinês | MEDLINE | ID: mdl-30957459

RESUMO

Needle retention is an important step in the acupuncture procedure. How to optimize scientifically the duration of needle retention according to individual case has been considered in the medical circle. In this paper, by collecting the literatures on needle retention from the early Qin dynasty to the contemporary time, the evolution of the needle retention from a short duration to a long one with the productivity improvement was elaborated. On the base of the views of the medical scholars of all dynasties, it was concluded that the ultimate purpose of needle retention is to improve the effects of acupuncture on the premise of ensuring the safety of acupuncture. Hence, the clinical physician should optimize the duration of needle retention cautiously in compliance with the tolerance of patient so as to save the time cost of both physician and patient, avoid the occurrence of tolerable effect of acupuncture and reduce the potential safety hazard of acupuncture induced by the long duration of needle retention.


Assuntos
Terapia por Acupuntura , Moxibustão , Médicos , Humanos , Agulhas , Fatores de Tempo
12.
Nature ; 564(7736): 430-433, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30518863

RESUMO

Heart transplantation is the only cure for patients with terminal cardiac failure, but the supply of allogeneic donor organs falls far short of the clinical need1-3. Xenotransplantation of genetically modified pig hearts has been discussed as a potential alternative4. Genetically multi-modified pig hearts that lack galactose-α1,3-galactose epitopes (α1,3-galactosyltransferase knockout) and express a human membrane cofactor protein (CD46) and human thrombomodulin have survived for up to 945 days after heterotopic abdominal transplantation in baboons5. This model demonstrated long-term acceptance of discordant xenografts with safe immunosuppression but did not predict their life-supporting function. Despite 25 years of extensive research, the maximum survival of a baboon after heart replacement with a porcine xenograft was only 57 days and this was achieved, to our knowledge, only once6. Here we show that α1,3-galactosyltransferase-knockout pig hearts that express human CD46 and thrombomodulin require non-ischaemic preservation with continuous perfusion and control of post-transplantation growth to ensure long-term orthotopic function of the xenograft in baboons, the most stringent preclinical xenotransplantation model. Consistent life-supporting function of xenografted hearts for up to 195 days is a milestone on the way to clinical cardiac xenotransplantation7.


Assuntos
Transplante de Coração , Xenoenxertos/transplante , Papio , Suínos , Transplante Heterólogo , Animais , Anticorpos/análise , Anticorpos/sangue , Proteínas do Sistema Complemento/análise , Enzimas/sangue , Fibrina/análise , Galactosiltransferases/deficiência , Galactosiltransferases/genética , Xenoenxertos/patologia , Humanos , Fígado/enzimologia , Masculino , Proteína Cofatora de Membrana/genética , Proteína Cofatora de Membrana/metabolismo , Miocárdio/enzimologia , Necrose , Perfusão , Contagem de Plaquetas , Tempo de Protrombina , Trombomodulina/genética , Trombomodulina/metabolismo , Fatores de Tempo
13.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 29(12): 1148-1152, 2017 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-29216954

RESUMO

OBJECTIVE: Klebsiella pneumoniae carbapenemases-producing Klebsiella pneumoniae (KPC-Kp) has caused a global public health crisis, and the severity of its infection is associated with high mortality in hospitalized patients. Therefore, the KPC-Kp prevention methods and the corresponding treatment strategy exploration are imminent. The risk factors and the treatment progress of KPC-Kp colonization or infection are reviewed in this paper to explore corresponding preventive measures and treatment strategies for clinical prevention and treatment.


Assuntos
Infecções por Klebsiella , Antibacterianos , Proteínas de Bactérias , Humanos , Klebsiella pneumoniae , Fatores de Risco , beta-Lactamases
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...