Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Sci ; 27(12): 1257-60, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22156257

RESUMO

Retention behaviors of pyrazine and alkylpyrazines on various stationary phases in reversed-phase liquid chromatography were examined. An abnormal temperature effect on the retention of alkylpyrazines with a mobile phase consisting of acetonitrile and water was observed when changing the column temperature. On the other hand, no similar trend was found with a methanol-water mobile phase. For all the columns investigated in this work, the above tendency to the temperature-dependence was consistently observed, suggesting that the abnormal temperature effect on the retention of alkylpyrazines could be mainly induced by an acetonitrile-based mobile phase.


Assuntos
Cromatografia Líquida/métodos , Pirazinas/química , Temperatura
2.
J Chromatogr A ; 1216(14): 2848-53, 2009 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-19013578

RESUMO

Fiber-packed sample preparation device was applied to the simultaneous derivatization/preconcentration of ethylene oxide (EO) in air samples. The polymer-coated filaments were packed longitudinally into the needle, and hydrogen bromide (HBr) was loaded onto the filaments in the preconditioning process. Simultaneous derivatization with HBr in the needle was made during the sampling process of the gaseous EO, and the corresponding derivatized analyte, 2-bromoethanol, was desorbed by passing a small amount of methanol through the extraction needle in the heated gas chromatograph (GC) injector. The basic extraction/desorption parameters for EO have been evaluated. The limit of detection (LOD), limit of quantification (LOQ) and the relative standard deviation (RSD) of run-to-run repeatability were 1.8 ng/L, 5.4 ng/L and less than 4%, respectively, with an extraction time of about 10 min. Satisfactory storage performance for three days at room temperature was also confirmed.


Assuntos
Métodos Analíticos de Preparação de Amostras/instrumentação , Etanol/análogos & derivados , Óxido de Etileno/análise , Etanol/análise , Cromatografia Gasosa-Espectrometria de Massas , Ácido Bromídrico/química
3.
Anal Bioanal Chem ; 393(3): 861-9, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18818906

RESUMO

A miniaturized sample preparation technique that uses a fine-fiber-packed needle as the extraction medium is reviewed, especially in relation to its application to the analysis of volatile organic compounds by gas chromatography. When the needle was packed longitudinally with a bundle of fine filaments (12 microm o.d.) which were also surface-coated with polymeric materials, successful sample preconcentration was obtained. Improved sensitivity was also established by introducing simultaneous derivatization reactions into the extraction process in the fiber-packed needle. The storage performance of the needle clearly demonstrated the potential of the technique for typical on-site sampling during environmental analysis. In this short review, the fiber-packed extraction needle developed by the authors is summarized along with applications that use the fiber-packed needle as a miniaturized extraction device.


Assuntos
Métodos Analíticos de Preparação de Amostras/instrumentação , Cromatografia Gasosa/instrumentação , Cromatografia Gasosa/métodos , Polímeros/química , Sensibilidade e Especificidade , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...