Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Phys Med Biol ; 66(7)2021 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-32998127

RESUMO

Dual-energy computed tomography (DECT) has been shown to allow for more accurate ion therapy treatment planning by improving the estimation of tissue stopping power ratio (SPR) relative to water, among other tissue properties. In this study, we measured and compared the accuracy of SPR values derived using both dual- and single-energy CT (SECT) based on different published conversion algorithms. For this purpose, a phantom setup containing either fresh animal soft tissue samples (beef, pork) and a water reference or tissue equivalent plastic materials was designed and irradiated in a clinical proton therapy facility. Dosimetric polymer gel was positioned downstream of the samples to obtain a three-dimensional proton range distribution with high spatial resolution. The mean proton range in gel for each tissue relative to the water sample was converted to a SPR value. Additionally, the homogeneous samples were probed with a variable water column encompassed by two ionization chambers to benchmark the SPR accuracy of the gel dosimetry. The SPR values measured with both methods were consistent with a mean deviation of 0.2%, but the gel dosimetry captured range variations up to 5 mm within individual samples.Across all fresh tissue samples the SECT approach yielded significantly greater mean absolute deviations from the SPR deduced using gel range measurements, with an average difference of 1.2%, compared to just 0.3% for the most accurate DECT-based algorithm. These results show a significant advantage of DECT over SECT for stopping power prediction in a realistic setting, and for the first time allow to compare a large set of methods under the same conditions.


Assuntos
Terapia com Prótons , Tomografia Computadorizada por Raios X , Animais , Bovinos , Imagens de Fantasmas , Prótons , Radiometria
3.
Phys Med Biol ; 65(24): 245045, 2020 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-33157544

RESUMO

A deeper understanding of biological mechanisms to promote more efficient treatment strategies in proton therapy demands advances in preclinical radiation research. However this is often limited by insufficient availability of adequate infrastructures for precision image guided small animal proton irradiation. The project SIRMIO aims at filling this gap by developing a portable image-guided research platform for small animal irradiation, to be used at clinical facilities and allowing for a precision similar to a clinical treatment, when scaled down to the small animal size. This work investigates the achievable dosimetric properties of different lowest energy clinical proton therapy beams, manipulated by a dedicated portable beamline including active focusing after initial beam energy degradation and collimation. By measuring the lateral beam size in air close to the beam nozzle exit and the laterally integrated depth dose in water, an analytical beam model based on the beam parameters of the clinical beam at the Rinecker Proton Therapy Center was created for the lowest available clinical beam energy. The same approach was then applied to estimate the lowest energy beam model of different proton therapy facilities, Paul Scherrer Institute, Centre Antoine Lacassagne, Trento Proton Therapy Centre and the Danish Centre for Particle Therapy, based on their available beam commissioning data. This comparison indicated similar beam properties for all investigated sites, with emittance values of a few tens of mm·mrad. Finally, starting from these beam models, we simulated propagation through a novel beamline designed to manipulate the beam energy and size for precise small animal irradiation, and evaluated the resulting dosimetric properties in water. For all investigated initial clinical beams, similar dosimetric results suitable for small animal irradiation were found. This work supports the feasibility of the proposed SIRMIO beamline, promising suitable beam characteristics to allow for precise preclinical irradiation at clinical treatment facilities.


Assuntos
Terapia com Prótons/instrumentação , Animais , Estudos de Viabilidade , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Síncrotrons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...