Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eye Vis (Lond) ; 9(1): 27, 2022 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-35794666

RESUMO

BACKGROUND: Glaucoma is the leading cause of irreversible blindness. Normal tension glaucoma (NTG) is a subset of open-angle glaucoma, demonstrating glaucomatous optic nerve damage in the absence of raised intraocular pressure (IOP). NTG is more prevalent in Asian populations. While generally slow-progressing, NTG may be associated with significant central visual field loss. In recent years, minimally invasive glaucoma surgery has been added to the armamentarium of glaucoma surgery. This prospective study aims to evaluate 12-month surgical outcomes of combined iStent inject (Glaukos Corporation, Laguna Hills, CA) implantation and phacoemulsification in Asian eyes with NTG. METHODS: This is a prospective, single-centre case series of 30 eyes followed up until 12 months after surgery. Outcome measures included IOP, number of glaucoma medications, best-corrected visual acuity (BCVA) and intra and postoperative complications. RESULTS: Mean age of subjects was 73.1 ± 6.3 years. Majority were ethnic Chinese (n = 27, 90%). Baseline medicated mean IOP was 13.8 ± 2.4 mmHg and mean number of glaucoma medications was 1.3 ± 0.7. Mean Humphrey visual field mean deviation was - 13.7 ± 7.6. The mean IOP reduction at all timepoints from postoperative month (POM) 3 onwards was statistically significant (all P < 0.05), with mean reduction of 1.2 mmHg (95% CI: 0.1-2.2, P = 0.037) by POM12. There was statistically significant reduction in mean number of medications from postoperative day (POD) 1 onwards (all P < 0.05), with mean decrease of 1.0 medication (95% CI: 0.9-1.1, P < 0.001) by POM12. By POM12, 25 (83.3%) eyes were medication-free. Three (10%) eyes had stent occlusion by iris requiring laser iridoplasty. One eye had gross hyphema which resolved on conservative management before POM1. Mean BCVA improved from the baseline 0.3 ± 0.3 logMAR to 0.1 ± 0.1 logMAR postoperatively (P < 0.001). There were no major adverse or sight-threatening events. No eyes required further glaucoma surgery during the 12-month follow-up period. CONCLUSION: Asian eyes with NTG which underwent combined iStent inject implantation and phacoemulsification demonstrated a significant and sustained reduction in IOP and glaucoma medications, up to 12 months postoperatively.

4.
BMC Ophthalmol ; 18(1): 315, 2018 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-30526537

RESUMO

BACKGROUND: Despite the potential usefulness of optical coherence tomography angiography in retinal and optic disc conditions, the reliability of the imaging modality remains unclear. This study set out to measure the microvascular density of macula and optic disc by mean of optical coherence tomography angiography and report the repeatability of the vessel density measurements. METHODS: Cross sectional observational cohort study. Subjects with normal eyes were recruited. Two sets of optical coherence tomography angiography images of macula and optic nerve head were acquired during one visit. Novel in-house developed software was used to count the pixels in each images and to compute the microvessel density of the macula and optic disc. Data were analysed to determine the measurement repeatability. RESULTS: A total of 176 eyes from 88 consecutive normal subjects were recruited. For macular images, the mean vessel density at superficial retina, deep retina, outer retina and choriocapillaries segment was OD 0.113 and OS 0.111, OD 0.239 and OS 0.230, OD 0.179 and OS 0.164, OD 0.237 and OS 0.215 respectively. For optic disc images, mean vessel density at vitreoretinal interface, radial peripapillary capillary, superficial nerve head and disc segment at the level of choroid were OD 0.084 and OS 0.085, OD 0.140 and OS 0.138, OD 0.216 and OS 0.209, OD 0.227 and OS 0.236 respectively. The measurement repeatability tests showed that the coefficient of variation of macular scans, for right and left eyes, ranged from 6.4 to 31.1% and 5.3 to 59.4%. Likewise, the coefficient of variation of optic disc scans, for right and left eyes, ranged from 14.3 to 77.4% and 13.5 to 75.3%. CONCLUSIONS: Optical coherence tomography angiography is a useful modality to visualise the microvasculature plexus of macula and optic nerve head. The vessel density measurement of macular scan by mean of optical coherence tomography angiography demonstrated good repeatability. The optic disc scan, on the other hand, showed a higher coefficient of variation indicating a lower measurement repeatability than macular scan. Interpretation of optical coherence tomography angiography should take into account test-retest repeatability of the imaging system. TRIAL REGISTRATION: National Healthcare Group Domain Specific Review Board ( NHG DSRB ) Singapore. DSRB Reference: 2015/00301.


Assuntos
Macula Lutea/irrigação sanguínea , Disco Óptico/irrigação sanguínea , Vasos Retinianos/citologia , Adulto , Estudos Transversais , Feminino , Angiofluoresceinografia/métodos , Humanos , Macula Lutea/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Disco Óptico/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/métodos
5.
Int J Ophthalmol ; 8(2): 342-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25938053

RESUMO

AIM: To determine angle closure agreements between gonioscopy and anterior segment optical coherence tomography (AS-OCT), as well as gonioscopy and spectral domain OCT (SD-OCT). A secondary objective was to quantify inter-observer agreements of AS-OCT and SD-OCT assessments. METHODS: Seventeen consecutive subjects (33 eyes) were recruited from the study hospital's Glaucoma clinic. Gonioscopy was performed by a glaucomatologist masked to OCT results. OCT images were read independently by 2 other glaucomatologists masked to gonioscopy findings as well as each other's analyses of OCT images. RESULTS: Totally 84.8% and 45.5% of scleral spurs were visualized in AS-OCT and SD-OCT images respectively (P<0.01). The agreement for angle closure between AS-OCT and gonioscopy was fair at k=0.31 (95% confidence interval, CI: 0.03-0.59) and k=0.35 (95% CI: 0.07-0.63) for reader 1 and 2 respectively. The agreement for angle closure between SD-OCT and gonioscopy was fair at k=0.21 (95% CI: 0.07-0.49) and slight at k=0.17 (95% CI: 0.08-0.42) for reader 1 and 2 respectively. The inter-reader agreement for angle closure in AS-OCT images was moderate at 0.51 (95% CI: 0.13-0.88). The inter-reader agreement for angle closure in SD-OCT images was slight at 0.18 (95% CI: 0.08-0.45). CONCLUSION: Significant proportion of scleral spurs were not visualised with SD-OCT imaging resulting in weaker inter-reader agreements. Identifying other angle landmarks in SD-OCT images will allow more consistent angle closure assessments. Gonioscopy and OCT imaging do not always agree in angle closure assessments but have their own advantages, and should be used together and not exclusively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA