Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Radiography (Lond) ; 30(1): 408-415, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38176131

RESUMO

INTRODUCTION: This study aimed to compare the vascular enhancement and radiation dose in preoperative transcatheter aortic valve implantation (TAVI) computed tomography (CT) with a reduced contrast medium (CM) using volume scans in 256-multidetector row CT (MDCT) with a standard CM using 64-MDCT. METHODS: This study included 78 patients with preoperative TAVI CT with either 64- or 256-MDCT. The CM was injected at 1.5 mL/kg in the 64-MDCT group and 1.0 mL/kg in the 256-MDCT group. We compared vascular enhancement of the aortic root and access routes, image quality (IQ) scores, and radiation dose in both groups. RESULTS: Despite the reduced CM (by 33 %) in the 256-MDCT group, the mean vascular enhancement of the right and left subclavian arteries was significantly higher than that in the 64-MDCT group [284 and 267 Hounsfield units (HU) vs. 376 and 359 HU; p < 0.05]; however, no significant differences in the mean vascular enhancement in the ascending aorta, abdominal aorta at the celiac level, and bilateral common femoral arteries were observed between the two groups (p > 0.05 for all). The median IQ scores at the aortic root were higher in the 256-MDCT group than in the 64-MDCT group (3 vs. 4; p < 0.05), and those at the femoral access routes were comparable (4 vs. 4; p = 0.33). The mean effective dose was significantly reduced by 30 % in the 256-MDCT group (23.6 vs. 16.3 mSv; p < 0.05). CONCLUSION: In preoperative TAVI CT, volume scans using 256-MDCT provide comparable or better vascular enhancement and IQ with a 30 % reduction in CM and radiation dose than those using 64-MDCT. IMPLICATIONS FOR PRACTICE: Volume scan using 256-MDCT for preoperative TAVI CT may reduce CM and radiation dose in TAVI patients with renal dysfunction.


Assuntos
Estenose da Valva Aórtica , Iodo , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Tomografia Computadorizada Multidetectores , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Doses de Radiação , Aorta Abdominal
2.
Radiologia (Engl Ed) ; 64(6): 525-532, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36402538

RESUMO

INTRODUCTION AND OBJECTIVES: Obtaining CCTA images with optimal injection location such as the arm or leg is important to avoid the artifacts caused by the CM. This study compares the computed tomography (CT) numbers and visualization scores of the three-dimensional (3D) images of the lumens of the blood vessels in the arm or leg during cardiac computed tomography angiography (CCTA) in neonatal and infant patients. PATIENTS OR MATERIALS AND METHODS: Between January 2017 and January 2020, 253 consecutive patients were considered for inclusion. We used the estimated propensity scores as a function of the demographic data, including age, body weight, and injection location (right or left side) in the arm (n = 58) and leg (n = 58) of neonatal and infant patients. We compared the mean CT numbers of the pulmonary artery, ascending aorta, and left superior vena cava; contrast-noise ratios (CNR); and visualization scores between the arm and leg as the injection locations. RESULTS: The mean CT numbers during CCTA for the arm and leg were 479.4 and 461.3 HU in the ascending aorta, 464.2 and 448.1 HU in the pulmonary artery, and 232.8 and 220.1 HU in the left superior vena cava, respectively. The mean image noise (SD) and CNR values, respectively, were 38.9 HU and 12.1 for the arm as the injection location and 39.1 HU and 12.3 for the leg as the injection location. The median visualization scores of volume rendering of the 3D images were 3.0 and 3.0 for the arm and leg injection sites, respectively. There were no significant differences in the mean CT numbers of the ascending aorta, pulmonary artery, and left superior vena cava; SD value; CNR; and visualization scores between the arm and leg injection locations. CONCLUSIONS: The CT numbers of the lumen of the blood vessel and visualization scores of the 3D images of the arm and leg injection locations are equal during CCTA in neonatal and infant patients with congenital heart disease.


Assuntos
Meios de Contraste , Veia Cava Superior , Humanos , Lactente , Recém-Nascido , Braço/diagnóstico por imagem , Perna (Membro) , Tomografia Computadorizada por Raios X/métodos
3.
Radiología (Madr., Ed. impr.) ; 64(6): 525-532, Nov-Dic. 2022. ilus, graf, tab
Artigo em Espanhol | IBECS | ID: ibc-211649

RESUMO

Introducción y objetivos: En la obtención de imágenes de angiografía por cardiotomografía (ACT) es importante escoger una ubicación adecuada para inyectar el medio de contraste (p. ej., el brazo o la pierna) a fin de evitar la formación de artefactos que este provoca. En este estudio se comparan los valores de tomografía computarizada (TC) y las puntuaciones de visualización de las imágenes tridimensionales (3D) de los lúmenes de los vasos sanguíneos del brazo y la pierna durante la ACT en pacientes neonatos y lactantes. Pacientes o materiales y métodos: Entre los meses de enero de 2017 y enero de 2020 se evaluaron 253 pacientes de forma consecutiva para determinar su inclusión en el estudio. Se utilizaron las puntuaciones de propensión estimadas en función de los datos demográficos, incluidos la edad, el peso corporal y la ubicación de la inyección (lado derecho o izquierdo) en el brazo (n=58) y la pierna (n=58) de los pacientes neonatos y lactantes. A continuación, se compararon los valores medios de TC de la arteria pulmonar, la aorta ascendente y la vena cava superior izquierda; las relaciones contraste-ruido (RCR); y las puntuaciones de visualización del brazo y la pierna como lugares de inyección. Resultados: Los valores medios de TC durante la ACT para el brazo y la pierna fueron de 479,4 y 461,3 UH en la aorta ascendente, de 464,2 y 448,1 UH en la arteria pulmonar y de 232,8 y 220,1 UH en la vena cava superior izquierda, respectivamente. Los valores medios de ruido de la imagen (DE) y de RCR fueron, respectivamente, de 38,9 y 12,1 UH para el brazo y de 39,1 y 12,3 UH para la pierna. Las puntuaciones medias de visualización de la representación del volumen de las imágenes 3D fueron de 3,0 y 3,0 para los lugares de inyección del brazo y la pierna, respectivamente.(AU)


Introduction and Objectives: Obtaining CCTA images with optimal injection location such as the arm or leg is important to avoid the artifacts caused by the CM. This study compares the computed tomography (CT) numbers and visualization scores of the three-dimensional (3D) images of the lumens of the blood vessels in the arm or leg during cardiac computed tomography angiography (CCTA) in neonatal and infant patients. Patients or Materials and Methods: Between January 2017 and January 2020, 253 consecutive patients were considered for inclusion. We used the estimated propensity scores as a function of the demographic data, including age, body weight, and injection location (right or left side) in the arm (n=58) and leg (n=58) of neonatal and infant patients. We compared the mean CT numbers of the pulmonary artery, ascending aorta, and left superior vena cava; contrast–noise ratios (CNR); and visualization scores between the arm and leg as the injection locations. Results: The mean CT numbers during CCTA for the arm and leg were 479.4 and 461.3 HU in the ascending aorta, 464.2 and 448.1 HU in the pulmonary artery, and 232.8 and 220.1 HU in the left superior vena cava, respectively. The mean image noise (SD) and CNR values, respectively, were 38.9 HU and 12.1 for the arm as the injection location and 39.1 HU and 12.3 for the leg as the injection location. The median visualization scores of volume rendering of the 3D images were 3.0 and 3.0 for the arm and leg injection sites, respectively. There were no significant differences in the mean CT numbers of the ascending aorta, pulmonary artery, and left superior vena cava; SD value; CNR; and visualization scores between the arm and leg injection locations. Conclusions: The CT numbers of the lumen of the blood vessel and visualization scores of the 3D images of the arm and leg injection locations are equal during CCTA in neonatal and infant patients with congenital heart disease.(AU)


Assuntos
Humanos , Recém-Nascido , Meios de Contraste/administração & dosagem , Angiografia , Cardiotocografia , Pediatria , Cardiopatias Congênitas , Pontuação de Propensão , Radiologia , Serviço Hospitalar de Radiologia , Diagnóstico por Imagem , Estudos Retrospectivos
5.
Radiography (Lond) ; 28(2): 420-425, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34702665

RESUMO

INTRODUCTION: To compare the computed tomography (CT) number for paediatric cardiac computed tomography angiography (CCTA) and visualisation score of the three-dimensional (3D) images using the conventional T-shaped extended tube (T-tube) and spiral flow-generating extended tube (spiral-tube) connected between the contrast injector and cannula. METHODS: In total, 108 patients suspected to have congenital heart disease (CHD) were considered for inclusion. We utilised the T-tube for intravenous contrast and spiral-tube in 54 patients each. Observers individually inspected randomized volume rendering images of the internal thoracic artery, each acquired from the with or without spiral-tube groups, using a four-point scale. We compared the mean CT number of the ascending aorta (AAO) and pulmonary artery (PA), contrast noise ratio (CNR), CT number for the AAO and PA enhancement ratio, and the visualisation scores between the groups. RESULTS: There were no significant differences in patient characteristics between the with or without spiral-tube groups (p > 0.05). The mean CT number ±standard deviation for the AAO and PA, and the CNR without or with spiral-tube groups were 441.2 ± 89.2 and 489.8 ± 86.1 HU for the AAO, 436.3 ± 100.6 and 475.3 ± 85.2 HU for the PA, and 9.5 ± 2.2 and 10.8 ± 2.4 for the CNR, respectively (p < 0.05). In the spiral-tube group, the CT number, CNR, and visualisations score of the 3D images were significantly higher for the AAO and PA than those in the T-tube group (p < 0.05). CONCLUSION: The spiral-tube proved to be beneficial in improving the CT number for the AAO and PA, CNR, and visualisation score compared with the conventional T-tube during paediatric CCTA. IMPLICATIONS FOR PRACTICE: The spiral-tube may allow the visualisation of smaller blood vessels than those visualised by the conventional T-tube for paediatric patients in CCTA.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Criança , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Coração , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
6.
Radiography (Lond) ; 28(2): 412-419, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34702666

RESUMO

INTRODUCTION: This study aimed to compare the correlation between the computed tomography (CT) enhancement rate of the venous to portal venous phase (VP-ER) and the extracellular volume (ECV) fraction with shear-wave ultrasound elastography (USE) findings in patients with liver fibrosis. METHODS: We included 450 patients with clinically suspected liver cirrhosis who underwent triphasic dynamic CT studies and USE. We compared the USE results with the unenhanced CT phase, with enhancement in the hepatic artery phase (HAP), portal venous phase (PVP), and venous phase (VP), and with the ECV fraction and the VP-ER. We also compared the area under the curve (AUC) of the receiver operating characteristic (ROC) curve of the ECV fraction and VP-ER with that of the values obtained with USE. RESULTS: The VP-ER was the most highly correlated with the liver stiffness value determined with USE (Pearson's correlation coefficient: r = 0.37), followed by enhancement in the PVP (r = -0.25), CT number on unenhanced CT scans (r = -0.22), the ECV fraction (r = 0.19), enhancement in the VP (r = 0.059), and enhancement in the HAP (r = -0.023) (all p < 0.01). The VP-ER showed a significantly higher AUC than the ECV fraction (0.75 vs 0.62) when the liver stiffness was >15 kPa in USE studies (p = 0.04). CONCLUSION: Compared to the ECV fraction, the VP-ER is more useful for predicting all degrees of liver fibrosis on routine triphasic dynamic CT images. IMPLICATIONS FOR PRACTICE: Although improvement is needed, the VP-ER has a higher diagnostic ability for liver fibrosis than the ECV fraction in clinical practice.


Assuntos
Técnicas de Imagem por Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Humanos , Cirrose Hepática/diagnóstico por imagem , Veia Porta/diagnóstico por imagem , Curva ROC , Tomografia Computadorizada por Raios X
7.
Radiography (Lond) ; 28(1): 61-67, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34404578

RESUMO

INTRODUCTION: Deep learning approaches have shown high diagnostic performance in image classifications, such as differentiation of malignant tumors and calcified coronary plaque. However, it is unknown whether deep learning is useful for characterizing coronary plaques without the presence of calcification using coronary computed tomography angiography (CCTA). The purpose of this study was to compare the diagnostic performance of deep learning with a convolutional neural network (CNN) with that of radiologists in the estimation of coronary plaques. METHODS: We retrospectively enrolled 178 patients (191 coronary plaques) who had undergone CCTA and integrated backscatter intravascular ultrasonography (IB-IVUS) studies. IB-IVUS diagnosed 81 fibrous and 110 fatty or fibro-fatty plaques. We manually captured vascular short-axis images of the coronary plaques as Portable Network Graphics (PNG) images (150 × 150 pixels). The display window level and width were 100 and 700 Hounsfield units (HU), respectively. The deep-learning system (CNN; GoogleNet Inception v3) was trained on 153 plaques; its performance was tested on 38 plaques. The area under the curve (AUC) obtained by receiver operating characteristic analysis of the deep learning system and by two board-certified radiologists was compared. RESULTS: With the CNN, the AUC and the 95% confidence interval were 0.83 and 0.69-0.96, respectively; for radiologist 1 they were 0.61 and 0.42-0.80; for radiologist 2 they were 0.68 and 0.51-0.86, respectively. The AUC for CNN was significantly higher than for radiologists 1 (p = 0.04); for radiologist 2 it was not significantly different (p = 0.22). CONCLUSION: DL-CNN performed comparably to radiologists for discrimination between fatty and fibro-fatty plaque on CCTA images. IMPLICATIONS FOR PRACTICE: The diagnostic performance of the CNN and of two radiologists in the assessment of 191 ROIs on CT images of coronary plaques whose type corresponded with their IB-IVUS characterization was comparable.


Assuntos
Aprendizado Profundo , Placa Aterosclerótica , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Redes Neurais de Computação , Placa Aterosclerótica/diagnóstico por imagem , Estudos Retrospectivos
8.
Radiography (Lond) ; 28(2): 440-446, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34844859

RESUMO

INTRODUCTION: To investigate how changing the injection duration at cardiac computed tomography angiography (CCTA) affects contrast enhancement in newborns and infants. METHODS: Included were 142 newborns and infants with confirmed congenital heart disease who underwent CCTA between January 2015 and December 2018. In group 1 (n = 71 patients), the injection duration was 8 s; in group 2 (n = 71) it was 16 s. Our findings were assessed by one-to-one matching analysis to estimate the propensity score of each patient. We compare the CT number for the pulmonary artery (PA), ascending aorta (AAO), left superior vena cava (SVC), AAO and PA enhancement ratio, and the scores for visualization between the two groups. RESULTS: In group 1, median CT number and ranges was 345 (211-591) HU in the AAO, 324 (213-567) HU in the PA, and 62 (1-70) HU in the SVC. These values were 465 (308-669) HU, 467 (295-638) HU, and 234 (67-443) HU, respectively, in group 2 (p < 0.05). The median score for volume-rendering visualization on 3D images of the CCTA was 2 in group 1 and 3 in group 2; the score for visualization of the left SVC of the maximum intensity projection images was 2 in group 1 and 3 in group 2 (p < 0.05). The CT number for the AAO and PA enhancement ratio was 15.2 in group 1 and 9.2 in group 2 (p < 0.05). CONCLUSION: The 16-sec injection protocol yielded significantly higher CT numbers for the AAO, PA, and the SVC than the 8-sec injection protocol; the visualization scores were also significantly higher in group 2. IMPLICATIONS FOR PRACTICE: In newborns and infants, the longer injection time for CCTA yields stable and higher contrast enhancement at identical CM concentrations.


Assuntos
Angiografia por Tomografia Computadorizada , Veia Cava Superior , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Humanos , Lactente , Recém-Nascido , Artéria Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Veia Cava Superior/diagnóstico por imagem
9.
Radiography (Lond) ; 27(3): 888-896, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33820690

RESUMO

INTRODUCTION: With intra-arterial digital subtraction angiography (DSA) considered as the gold standard, we compared the diagnostic value of computed tomography angiography (CTA) and computed tomography-digital subtraction angiography (CT-DSA in hemodialysis (HD) patients suspected of having lower limb peripheral artery disease (PAD). METHODS: In this retrospective study, we enrolled 220 HD patients with suspected PAD. CT-DSA images were obtained by subtracting unenhanced images from enhanced images. The research team calculated the area under the curve (AUC), sensitivity, specificity, positive and negative predictive value (PPV, NPV), and recorded the diagnostic accuracy between the CTA and CT-DSA images using the DSA as gold standard. Visual evaluation of calcifications in the peripheral arteries were also compared between CTA and CT-DSA images. RESULTS: At the above-knee level, the CTA AUC [95% confidence interval (CI)] was 0.68 (CI 0.64-0.72), sensitivity and specificity were 60 and 81%, PPV and NPV were 85 and 53%, and accuracy was 67%. Below the knee, these values were 0.66 (CI 0.62-0.70), 71 and 79%, 79 and 47%, and 66%. For CT-DSA, above-knee, the AUC [95% CI] was 0.88 (CI 0.85-0.91), sensitivity and specificity were 84 and 92%, PPV and NPV were 89 and 97%, and accuracy was 93%. Below the knee, these values were 0.95 (CI 0.93-0.97), 95 and 93%, 96 and 83%, and 93%. The scores for the visualization of calcification in the peripheral arteries was significantly higher for CT-DSA than CTA (p < 0.05). CONCLUSIONS: CT-DSA helps to assess stenotic PAD with high calcification in the lower extremities of HD patients. IMPLICATIONS FOR PRACTICE: On CT-DSA images, the severity of vascular calcification can be assessed for HD patients suspected of PAD of the lower extremities.


Assuntos
Doença Arterial Periférica , Angiografia Digital , Humanos , Extremidade Inferior/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Diálise Renal , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
10.
Radiography (Lond) ; 27(3): 920-926, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33762147

RESUMO

INTRODUCTION: We compared the diagnostic performance of morphological methods such as the major axis, the minor axis, the volume and sphericity and of machine learning with texture analysis in the identification of lymph node metastasis in patients with thyroid cancer who had undergone contrast-enhanced CT studies. METHODS: We sampled 772 lymph nodes with histology defined tissue types (84 metastatic and 688 benign lymph nodes) that were visualised on CT images of 117 patients. A support vector machine (SVM), free programming software (Python), and the scikit-learn machine learning library were used to discriminate metastatic-from benign lymph nodes. We assessed 96 texture and 4 morphological features (major axis, minor axis, volume, sphericity) that were reported useful for the differentiation between metastatic and benign lymph nodes on CT images. The area under the curve (AUC) obtained by receiver operating characteristic analysis of univariate logistic regression and SVM classifiers were calculated for the training and testing datasets. RESULTS: The AUC for all classifiers in training and testing datasets was 0.96 and 0.86, at the SVM for machine learning. When we applied conventional methods to the training and testing datasets, the AUCs were 0.63 and 0.48 for the major axis, 0.70 and 0.44 for the minor axis, 0.66 and 0.43 for the volume, and 0.69 and 0.54 for sphericity, respectively. The SVM using texture features yielded significantly higher AUCs than univariate logistic regression models using morphological features (p = 0.001). CONCLUSION: For the identification of metastatic lymph nodes from thyroid cancer on contrast-enhanced CT images, machine learning combined with texture analysis was superior to conventional diagnostic methods with the morphological parameters. IMPLICATIONS FOR PRACTICE: Our findings suggest that in patients with thyroid cancer and suspected lymph node metastasis who undergo contrast-enhanced CT studies, machine learning using texture analysis is high diagnostic value for the identification of metastatic lymph nodes.


Assuntos
Neoplasias da Glândula Tireoide , Tomografia Computadorizada por Raios X , Humanos , Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Aprendizado de Máquina , Neoplasias da Glândula Tireoide/diagnóstico por imagem
11.
Clin Radiol ; 75(1): 79.e9-79.e18, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31662200

RESUMO

AIM: To examine whether Positron Emission Tomography Response Criteria in Solid Tumours (PERCIST) is useful to predict tumour response and prognosis of patients with oesophageal cancer who received neoadjuvant chemoradiotherapy (NACRT) followed by surgery. MATERIALS AND METHODS: This multicentre retrospective study included 60 patients with oesophageal cancer who underwent 2-[18F]-fluoro-2-deoxy-d-glucose positron-emission tomography/computed tomography (18F-FDG-PET/CT) before and after NACRT prior to surgery from January 2007 and June 2016. The correlation between pathological response and PERCIST was assessed by χ2 test. The prognostic significance was assessed by the Kaplan-Meier method and Cox regression analysis. RESULTS: There were 30 responders and 30 non-responders pathologically. The complete metabolic response (CMR), partial metabolic response (PMR), stable metabolic disease (SMD), and progressive metabolic disease (PMD) were seen in 22, 29, seven, and two patients, respectively. There was a significant correlation between pathological response and PERCIST (p<0.001). Forty patients showed eventual progression, and 20 patients were alive without progression between the start of NACRT and last clinical follow-up (median follow-up period; 27 months [range, 3-107]). Pathological stage and PERCIST were significant for progression-free survival (PFS; p=0.044 and 0.006, respectively) and also significant for overall survival (OS; p=0.009 and 0.001, respectively) at univariate analysis. Pathological lymph node staging was also significant for OS at univariate analysis (p=0.018). At multivariate analysis, PERCIST remained significant and independent for PFS (hazard ratio [HR]: 1.59, p=0.046) and OS (HR: 1.82, p=0.008). CONCLUSION: PERCIST may be useful for predicting tumour response and prognosis of patients with oesophageal cancer who received NACRT.


Assuntos
Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/terapia , Tomografia por Emissão de Pósitrons , Adulto , Idoso , Quimiorradioterapia , Neoplasias Esofágicas/patologia , Feminino , Fluordesoxiglucose F18 , Humanos , Japão , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Terapia Neoadjuvante , Valor Preditivo dos Testes , Prognóstico , Compostos Radiofarmacêuticos , Estudos Retrospectivos
12.
AJNR Am J Neuroradiol ; 37(12): 2328-2333, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27516241

RESUMO

BACKGROUND AND PURPOSE: DWI with conventional single-shot EPI of the pituitary gland is hampered by strong susceptibility artifacts. Our purpose was to evaluate the feasibility of intravoxel incoherent motion assessment by using DWI based on TSE of the normal anterior pituitary lobe. MATERIALS AND METHODS: The intravoxel incoherent motion parameters, including the true diffusion coefficient (D), the perfusion fraction (f), and the pseudo-diffusion coefficient (D*), were obtained with TSE-DWI in 5 brain regions (the pons, the WM and GM of the vermis, and the genu and splenium of the corpus callosum) in 8 healthy volunteers, and their agreement with those obtained with EPI-DWI was evaluated by using the intraclass correlation coefficient. The 3 intravoxel incoherent motion parameters in the anterior pituitary lobe were compared with those in the brain regions by using the Dunnett test. RESULTS: The agreement between TSE-DWI and EPI-DWI was moderate (intraclass correlation coefficient = 0.571) for D, substantial (0.699) for f', but fair (0.405) for D*. D in the anterior pituitary lobe was significantly higher than in the 5 brain regions (P < .001). The f in the anterior pituitary lobe was significantly higher than in the 5 brain regions (P < .001), except for the vermian GM. The pituitary D* was not significantly different from that in the 5 brain regions. CONCLUSIONS: Our results demonstrated the feasibility of intravoxel incoherent motion assessment of the normal anterior pituitary lobe by using TSE-DWI. High D and f values in the anterior pituitary lobe were thought to reflect its microstructural and perfusion characteristics.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Hipófise/diagnóstico por imagem , Adulto , Artefatos , Feminino , Humanos , Masculino , Movimento (Física)
13.
Clin Radiol ; 71(12): 1284-1288, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27146898

RESUMO

AIM: To evaluate the effectiveness of motion-sensitised driven-equilibrium (MSDE)-prepared balanced magnetic resonance cholangiopancreatography (MRCP) in a gadolinium ethoxybenzyl diethylene triamine pentaacetic acid (Gd-EOB-DTPA)-enhanced study compared to conventional T2-weighted MRCP. MATERIALS AND METHODS: Fifteen patients (seven male and eight female patients) prospectively underwent conventional three-dimensional turbo spin-echo T2-weighted MRCP and MSDE-balanced MRCP using a 1.5 T MRI system after hepatobiliary phase image acquisition. For quantitative evaluation, the contrast-to-noise ratio (CNR) of the common hepatic duct to liver tissue was calculated. For qualitative analysis, two radiologists evaluated the depiction of the biliary system and main pancreatic duct (MPD) using a scoring system. Signal suppression of the portal vein (PV) and hepatic vein (HV) on MSDE-balanced MRCP was also scored. RESULTS: MSDE-balanced MRCP showed significantly higher CNR than T2-weighted MRCP. For all biliary structures, the mean depiction scores of MSDE-balanced MRCP were significantly higher than those of T2-weighted MRCP, whereas the mean depiction score of MPD with MSDE-balanced MRCP was significantly lower than that of T2-weighted MRCP. Signal suppression of the PV and HV was thought to be clinically sufficient. CONCLUSIONS: MSDE-balanced MRCP more clearly depicted biliary structures compared with T2-weighted MRCP in a Gd-EOB-DTPA-enhanced study. This sequence may be utilised for routine MRCP on Gd-EOB-DTPA-enhanced MRI.


Assuntos
Sistema Biliar/diagnóstico por imagem , Colangiopancreatografia por Ressonância Magnética/métodos , Meios de Contraste , Gadolínio DTPA , Aumento da Imagem/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Estudos Prospectivos , Reprodutibilidade dos Testes
14.
AJNR Am J Neuroradiol ; 37(1): 58-65, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26405082

RESUMO

BACKGROUND AND PURPOSE: Glioblastoma multiforme is highly aggressive and the most common type of primary malignant brain tumor in adults. Imaging biomarkers may provide prognostic information for patients with this condition. Patients with glioma with isocitrate dehydrogenase 1 (IDH1) mutations have a better clinical outcome than those without such mutations. Our purpose was to investigate whether the IDH1 mutation status in glioblastoma multiforme can be predicted by using MR imaging. MATERIALS AND METHODS: We retrospectively studied 55 patients with glioblastoma multiforme with wild type IDH1 and 11 patients with mutant IDH1. Absolute tumor blood flow and relative tumor blood flow within the enhancing portion of each tumor were measured by using arterial spin-labeling data. In addition, the maximum necrosis area, the percentage of cross-sectional necrosis area inside the enhancing lesions, and the minimum and mean apparent diffusion coefficients were obtained from contrast-enhanced T1-weighted images and diffusion-weighted imaging data. Each of the 6 parameters was compared between patients with wild type IDH1 and mutant IDH1 by using the Mann-Whitney U test. The performance in discriminating between the 2 entities was evaluated by using receiver operating characteristic analysis. RESULTS: Absolute tumor blood flow, relative tumor blood flow, necrosis area, and percentage of cross-sectional necrosis area inside the enhancing lesion were significantly higher in patients with wild type IDH1 than in those with mutant IDH1 (P < .05 each). In contrast, no significant difference was found in the ADC(minimum) and ADC(mean). The area under the curve for absolute tumor blood flow, relative tumor blood flow, percentage of cross-sectional necrosis area inside the enhancing lesion, and necrosis area were 0.850, 0.873, 0.739, and 0.772, respectively. CONCLUSIONS: Tumor blood flow and necrosis area calculated from MR imaging are useful for predicting the IDH1 mutation status.


Assuntos
Neoplasias Encefálicas/genética , Imagem de Difusão por Ressonância Magnética/métodos , Glioblastoma/genética , Isocitrato Desidrogenase/genética , Adulto , Idoso , Área Sob a Curva , Neoplasias Encefálicas/irrigação sanguínea , Neoplasias Encefálicas/patologia , Estudos Transversais , Feminino , Glioblastoma/irrigação sanguínea , Glioblastoma/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Mutação , Prognóstico , Curva ROC , Estudos Retrospectivos , Marcadores de Spin
16.
AJNR Am J Neuroradiol ; 35(1): 95-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23868152

RESUMO

BACKGROUND AND PURPOSE: 3D turbo field echo with diffusion-sensitized driven-equilibrium preparation is a non-echo-planar technique for DWI, which enables high-resolution DWI without field inhomogeneity-related image distortion. The purpose of this study was to evaluate the feasibility of diffusion-sensitized driven-equilibrium turbo field echo in evaluating diffusivity in the normal pituitary gland. MATERIALS AND METHODS: First, validation of diffusion-sensitized driven-equilibrium turbo field echo was attempted by comparing it with echo-planar DWI. Five healthy volunteers were imaged by using diffusion-sensitized driven-equilibrium turbo field echo and echo-planar DWI. The imaging voxel size was 1.5 × 1.5 × 1.5 mm(3) for diffusion-sensitized driven-equilibrium turbo field echo and 1.5 × 1.9 × 3.0 mm(3) for echo-planar DWI. ADCs measured by the 2 methods in 15 regions of interests (6 in gray matter and 9 in white matter) were compared by using the Pearson correlation coefficient. The ADC in the pituitary anterior lobe was then measured in 10 volunteers by using diffusion-sensitized driven-equilibrium turbo field echo, and the results were compared with those in the pons and vermis by using a paired t test. RESULTS: The ADCs from the 2 methods showed a strong correlation (r = 0.79; P < .0001), confirming the accuracy of the ADC measurement with the diffusion-sensitized driven-equilibrium sequence. The ADCs in the normal pituitary gland were 1.37 ± 0.13 × 10(-3) mm(2)/s, which were significantly higher than those in the pons (1.01 ± 0.24 × 10(-3) mm(2)/s) and the vermis (0.89 ± 0.25 × 10(-3) mm(2)/s, P < .01). CONCLUSIONS: We demonstrated that diffusion-sensitized driven-equilibrium turbo field echo is feasible in assessing ADC in the pituitary gland.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Hipófise/anatomia & histologia , Adulto , Encéfalo/anatomia & histologia , Química Encefálica , Difusão , Feminino , Voluntários Saudáveis , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Dentomaxillofac Radiol ; 41(7): 601-4, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22752322

RESUMO

OBJECTIVE: The aim of this study was to assess the feasibility of ultrashort echo time (UTE) imaging in the visualization of middle ear ossicles in normal subjects. METHODS: 12 young adult volunteers (males/females = 6/6, age 25-44 years, mean 30.3 years) with normal hearing levels underwent MRI studies using a 3.0 T clinical unit with an eight-channel SENSE head coil. For each subject, the whole head was imaged using a three-dimensional dual-echo UTE imaging sequence with radial trajectory and the following parameters: field of view, 240 × 240 × 240 mm; matrix, 320 × 320; flip angle, 7°; repetition time/echo time (TE)1/TE2, 8.0 ms/0.14 ms/1.8 ms; acquisition voxel size, 0.75 × 0.75 × 0.75 mm; number of signals averaged, 1; imaging time, 27 min 20 s. Subsequently, subtraction images were obtained by subtracting long TE (1.8 ms) images from short TE (0.14 ms) images. By using these three images, the visibility of the bilateral middle ear ossicles was evaluated. Moreover, as a reference for the UTE findings, CT images of the temporal bone were obtained in one volunteer. RESULTS: In all subjects, the middle ear ossicles were clearly visualized as a high signal intensity spot surrounded by a signal void of air on short TE images bilaterally, while they were not visible in long TE images in any of the subjects. The subtraction images provided better contrast of the ossicles. CONCLUSION: We demonstrated the feasibility of UTE imaging of the middle ear ossicle in normal subjects.


Assuntos
Ossículos da Orelha/anatomia & histologia , Imagem Ecoplanar/métodos , Adulto , Ossículos da Orelha/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Estudos Prospectivos , Técnica de Subtração , Osso Temporal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
18.
AJNR Am J Neuroradiol ; 32(10): 1904-10, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21778248

RESUMO

BACKGROUND AND PURPOSE: Few studies have investigated the relationship between ADC and clinical outcome in HNSCC. Our hypothesis has that relatively high pretreatment ADC would correlate with local failure of HNSCC treated with radiation therapy. MATERIALS AND METHODS: This includes prospective and validation studies. Seventeen patients treated with radiation therapy for primary HNSCC completed the prospective study. Variables considered to affect local failure including MR imaging-related parameters such as ADC and its change ratio were compared between patients with local failure and controls, and those showing difference or association with local failure were further tested by survival analysis. Furthermore, variables were analyzed in 40 patients enrolled in the validation study. RESULTS: Relatively high ADC calculated with b-values (300, 500, 750, and 1000 s/mm(2)) before treatment, high ADC increase ratio, and treatment method (chemoradiotherapy versus radiation therapy alone) revealed significant difference between patients with local failure and controls or association with local failure. In Cox proportional hazard testing, high ADC before treatment alone showed significant association with local failure (P = .0186). In the validation study, tumor volume before treatment, high ADC before treatment, T stage (T12 versus T34), and treatment method showed significance. Tumor volume before treatment (P = .0217) and high ADC before treatment (P = .0001) revealed significant association with local failure in Cox proportional hazard testing. High ADC before treatment was superior to tumor volume before treatment regarding association with local failure. CONCLUSIONS: These results suggest pretreatment ADC obtained at high b-values as well as tumor volume correlate with local failure of HNSCC treated with radiation therapy.


Assuntos
Algoritmos , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeça e Pescoço/patologia , Neoplasias de Cabeça e Pescoço/radioterapia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Falha de Tratamento
19.
AJNR Am J Neuroradiol ; 32(10): 1915-8, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21778245

RESUMO

BACKGROUND AND PURPOSE: Previous reports have shown that DWI is useful in detecting cholesteatoma. SS-EPI is the most widely used DWI technique. However, SS-EPI may have susceptibility artifacts due to field inhomogeneity in the imaging of the temporal bone region. Our purpose was to prospectively evaluate the advantage of MS-EPI for the diagnosis of middle ear cholesteatoma by comparing it with SS-EPI. MATERIALS AND METHODS: We studied 29 patients with preoperatively suspected acquired cholesteatoma. Each patient underwent an MR imaging examination including both SS-EPI and MS-EPI by using a 1.5T MR imaging scanner. Images of the 29 patients (58 temporal bones including 30 with and 28 without cholesteatoma) were reviewed by 2 independent neuroradiologists. The confidence level for the presence of cholesteatoma was graded on a scale of 0-2 (0 = none, 1 = equivocal, 2 = definite). Interobserver agreement as well as sensitivity, specificity, and accuracy were assessed for the 2 readers. RESULTS: Excellent interobserver agreement was shown for both MS-EPI (κ = 0.856) and SS-EPI (κ = 0.820). MS-EPI was associated with higher sensitivity (76.7%) and accuracy (87.9%) than SS-EPI (sensitivity = 50.0%, accuracy = 74.1%) (P < .05), while both methods showed 100% specificity. CONCLUSIONS: Compared with SS-EPI, MS-EPI improves the accuracy of the diagnosis of acquired middle ear cholesteatomas.


Assuntos
Colesteatoma da Orelha Média/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Aumento da Imagem/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
20.
AJNR Am J Neuroradiol ; 32(4): 664-70, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21292797

RESUMO

BACKGROUND AND PURPOSE: MSDE preparation is a technique for black-blood imaging. Our purpose was to evaluate the usefulness of a 3D TSE sequence with MSDE preparation in detecting brain metastases by comparing it with conventional sequences. MATERIALS AND METHODS: Postcontrast images of 227 patients who were suspected of having brain metastasis were prospectively obtained by using 3 T1-weighted 3D sequences: a gradient-echo sequence (MPRAGE), TSE-noMSDE, and TSE-MSDE. The number of visualized blood vessels and the lesion-to-normal CNR were compared among the 3 sequences. An observer test involving 9 radiologists was performed, and their diagnostic performance by using TSE-MSDE, MPRAGE, and combined TSE-MSDE and MPRAGE was compared by means of an FOM as an index of diagnostic performance derived by the JAFROC analysis, sensitivity, FP/case, and reading time. RESULTS: TSE-MSDE resulted in significantly better vessel suppression than the other 2 methods. TSE with and without MSDE resulted in significantly higher CNRs than MPRAGE. In the observer test, significantly higher sensitivity and FOM as well as significantly shorter reading time were achieved by TSE-MSDE compared with MPRAGE, but FP/case was significantly higher with TSE-MSDE. Combined TSE-MSDE/MPRAGE resulted in significantly higher sensitivity and FOM and similar FP/case and reading time compared with MPRAGE alone. CONCLUSIONS: With blood vessel suppression and increased CNR, TSE-MSDE improves radiologists' performances in detecting brain metastases compared with MPRAGE, but it may increase FP results. Combined with MPRAGE, TSE-MSDE achieves high diagnostic performance while maintaining a low FP rate.


Assuntos
Neoplasias Encefálicas/secundário , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Neoplasias Pulmonares/patologia , Neurorradiografia/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Neoplasias da Mama/patologia , Artérias Cerebrais/anatomia & histologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Bucais/patologia , Neurorradiografia/estatística & dados numéricos , Variações Dependentes do Observador , Neoplasias Pancreáticas/patologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...