Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(6): 1794-8, 2016 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-30052394

RESUMO

To obtain the weaker second harmonic signal of low concentration, reduce the minimum measurable limit and improve the sensitivity and accuracy of absorption measurement, a serious of data processing methods are proposed based on tunable diode laser wavelength modulation spectroscopy. The experiment on lower NH3 concentration at 2.25 µm was carried out in a 10.13 m absorption cell with different concentration. The peak height of the second harmonic signal is maximum at m=2.2, which optimizes the signal-to-noise ratio. In order to guarantee the optimal signal-to-noise ratio, the experiment was carried out by loading the optimal high frequency modulation signal. WMS-2f was performed at a repetitive scan rate of 200 Hz and a current-modulation rate of 15 kHz, wavelength modulation spectroscopy with the optimal signal-to-noise ratio was adopted for its better noise immunity to measure different lower NH3 concentration in the Herriott cell. This survey is focused on the ν2+ν3 bands of absorption spectra near 2.25 µm in near-infrared region at ambient temperature and pressure, the line strengths of 2.25 µm are much larger than the absorption lines in the telecommunication bands, using stronger NH3 absorption lines can offer the potential of lower detection limits. During the data processing, the background signal of the original harmonic should be deducted at first, the second harmonic signal of 0.6×10-6 was obtained in a 10 m long-path Herriott cell after data processing, these signal processing mainly consist of cross-correlation analysis, multiple averages and wavelet transform analysis, the cross-correlation analysis was used to control the shift of center wavelength, the multiple averages and wavelet transform analysis were used to reduce influences of the environment noise, after that we get the revised second harmonic signal and improve the accuracy of the measurement results. The experimental results show that these data processing methods can obviously improve the signal quality and reduce the minimum measurable limit about 100 times lower than before. The experiment doesn't need to add any laboratory equipment and can well restrain the influence of the environmental noise and other disturbance, so these signal process combined with wavelength modulation technique will be more useful for on-line gas detection technology.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(6): 1639-42, 2015 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-26601382

RESUMO

In order to on-line measure the trace ammonia slip of the commercial power plant in the future, this research seeks to measure the trace ammonia by using tunable diode laser absorption spectroscopy under ambient temperature and pressure, and at different temperatures, and the measuring temperature is about 650 K in the power plant. In recent years lasers have become commercially available in the near-infrared where the transitions are much stronger, and ammonia's spectroscopy is pretty complicated and the overlapping lines are difficult to resolve. A group of ammonia transitions near 4 433.5 cm(-1) in the v2 +v3 combination band have been thoroughly selected for detecting lower concentration by analyzing its absorption characteristic and considering other absorption interference in combustion gases where H2O and CO2 mole fraction are very large. To illustrate the potential for NH3 concentration measurements, predictions for NH3, H2O and CO2 are simultaneously simulated, NH3 absorption lines near 4 433.5 cm(-1) wavelength meet weaker H2O absorption than the commercial NH3 lines, and there is almost no CO2 absorption, all the parameters are based on the HITRAN database, and an improved detection limit was obtained for interference-free NH3 monitoring, this 2.25 µm band has line strengths several times larger than absorption lines in the 1.53 µm band which was often used by NH3 sensors for emission monitoring and analyzing. The measurement system was developed with a new Herriott cell and a heated gas cell realizing fast absorption measurements of high resolution, and combined with direct absorption and wavelenguh modulation based on tunable diode laser absorption spectroscopy at different temperatures. The lorentzian line shape is dominant at ambient temperature and pressure, and the estimated detectivity is approximately 0.225 x 10(-6) (SNR = 1) for the directed absorption spectroscopy, assuming a noise-equivalent absorbance of 1 x 10(-4). The heated cell experiments with controlled the temperature were performed to validate the sensing strategy. Here the Wavelength Modulation Spectroscopy (WMS) strategy was usually used to measure lower gas concentration for high noise immunity to the non-absorption transmission losses. The great agreement 2f signal with the calibrated concentration is within the uncertainty at different temperatures by using simple digital signal processing such as multiple averages, wavelet analysis and so on. The denoise processing has a great advantage in application and implementation over other noise suppression techniques. The result provided a good basis for trace ammonia escape detection based on tunable diode laser absorption spectroscopy.

3.
World J Gastroenterol ; 6(5): 693-698, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11819676

RESUMO

AIM:To determine the expression and clinical significance of chromogranin A and cathepsin D in hepatocellular carcinoma (HCC).METHODS:Double immunofluorescence stain-ing techniques combined with laser confocal scanning microscopy (LSCM) was used to investigate chromogranin A and cathepsin D expressions in 85 HCC patients.RESULTS:Cathepsin D was expressed in 3 normal liver tissues, while in HCC the staining showed regional variation and the fraction of strongly stained cells increased as the tumors became less differentiated and usually clinically more malignant.Cells which showed strong positivity for cathepsin D were present in 71/85(83.5%) cases. Strong expression of cathepsin D in cancer cells was related to histopathological features. They were more common in grade 3-4 (26/28, 92.9%) and grade 2 (46/53, 86.8%) tumors than in grade 1 tumors (1/4, 25.0%)(P <0.01). No significant correlation was found between age and cathepsin D expression. In patients with positive cathepsin D reaction, the mean age was 52.1± 2.8 years (range 32-68 years) and in the group with negative reaction, the mean age was 51.3± 4.5 years (range 28-71 years). No obvious relationship was observed between CgA expression in cancer cells and the histopathological features. The CgA positive rate was 75.0% (3/4) in grade 1, 71.7% (38/53) in grade 2,and 71.4% (20/28) in grade 3-4(P >0.05) tumors. The coexpression of CgA and cathepsin D was found by double labeled immunofluorescence staining techniques. The processing of cathepsin D was disturbed in HCC cells and accumulated in the cells.Cathepsin D had proteolytic activity and autocrine mitogenic effect, suggesting their functions in invasion. These findings demonstrated that the expression of cathepsin D in HCC had prognostic value.CONCLUSION:Chromogranin A and cathepsin D are expressed in a high proportion of HCC and the existence of cathepsin D in HCC might be related to processing of CgA. This is clearly a subject for further studies because of its potential clinical applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA