1.
Anal Bioanal Chem ; 416(2): 509-518, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37989848

RESUMO

The application of standing surface acoustic wave (SSAW) tweezers based on backpropagation superposition to achieve precise behavior manipulation of microscale cells and even nanoscale bacteria has been widely studied and industrialized. However, the structure requires multiple transducer components or full channel resonance. It is very challenging to design a simple structure for nano-control by complex acoustic field. In this study, a reflector-interdigital transducer (R-IDT) acoustofluidic device based on unilateral coherence enhancement is proposed to achieve SSAW definition features of periodic particle capture positions. The SAW device based on a unilateral transducer can not only generate leaky-SAW in water-filled microchannel, but also have a contribution of spherical waves in the vibration area of the substrate-liquid interface due to the Huygens-Fresnel diffractive principle. Both of them form a robust time-averaged spatial periodicity in the pressure potential gradient, accurately predicting the lateral spacing of these positions through acoustic patterning methods. Furthermore, a reflector based on Bragg-reflection is used to suppress backward transmitted SAW and enhance forward conducted SAW beams. By using a finite element model, R-IDT structure's amplitude enhances 60.78% compared to single IDT structure. The particle manipulation range of the diffractive acoustic field greatly improves, verified by experimental polystyrene microspheres. Besides, biocompatibility is conformed through red blood cells and Bacillus subtilis. We investigate the overall shift of periodic pressure field that can still occur when the phase changes. This work provides a simpler and low-cost solution for the application of acoustic tweezer in biological cell culture and filtering.

2.
Micromachines (Basel) ; 14(11)2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-38004845

RESUMO

In micron or nano smart sensing systems, piezoelectric cantilever beams are distributed as major components in microsensors, actuators, and energy harvesters. This paper investigates the performance of four cantilever beam devices with "electric-force" conversion based on the inverse piezoelectric effect of lithium niobate (LiNbO3, LN) single-crystal materials. A new compact piezoelectric smart device model is proposed, designed as a single mass block connected by four beams, where devices exhibit smaller lateral errors (0.39-0.41%). The relationship between the displacement characteristics of cantilever beams and driving voltage was researched by applying excitation signals. The results show that the device has the maximum displacement at a first-order intrinsic frequency (fosc = 11.338 kHz), while the displacement shows a good linear relationship (R2 = 0.998) with driving voltage. The square wave signals of the same amplitude have greater "electrical-force" conversion efficiency. The output displacement can reach 12 nm, which is much higher than the output displacement with sinusoidal excitation. In addition, the relative displacement deviation of devices can be maintained within ±1% under multiple cycles of electrical signal loading. The small size, high reliability, and ultra-stability of Si-LN ferroelectric single-crystal cantilever beam devices with lower vibration amplitudes are promising for nanopositioning techniques in microscopy, diagnostics, and high-precision manufacturing applications.

3.
Anal Chim Acta ; 1255: 341138, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37032055

RESUMO

Obtaining highly purified intact living cells from complex environments has been a challenge, such as the isolation of circulating tumor cells (CTCs) from blood. In this work, we demonstrated an acoustic-based ultra-compact device for cell sorting, with a chip size of less than 2 × 1.5 cm2. This single actuator device allows non-invasive and label-free isolation of living cells, offering greater flexibility and applicability. The device performance was optimized with different-sized polystyrene (PS) particles and blood cells spiked with cancer cells. Using the narrow-path travelling surface acoustic wave (np-TSAW), precise isolation of 10 µm particles from a complex mixture of particles (5, 10, 20 µm) and separation of 8 µm and 10 µm particles was achieved. The purified collection of 10 µm particles with high separation efficiency (98.75%) and high purity (98.1%) was achieved by optimizing the input voltage. Further, we investigated the isolation and purification of CTCs (MCF-7, human breast cancer cells) from blood cells with isolation efficiency exceeding 98% and purity reaching 93%. Viabilities of the CTCs harvested from target-outlet were all higher than 97% after culturing for 24, 48, and 72 h, showing good proliferation ability. This novel ultra-miniaturized microfluidic chip demonstrates the ability to sorting cells with high-purity and label-free, providing an attractive miniaturized system alternative to traditional sorting methods.


Assuntos
Técnicas Analíticas Microfluídicas , Células Neoplásicas Circulantes , Humanos , Células Neoplásicas Circulantes/patologia , Separação Celular/métodos , Linhagem Celular Tumoral , Microfluídica/métodos , Som
4.
Biosensors (Basel) ; 12(12)2022 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-36551146

RESUMO

Multifunctional, integrated, and reusable operating platforms are highly sought after in biochemical analysis and detection systems. In this study, we demonstrated a novel detachable, reusable acoustic tweezer manipulation platform that is flexible and versatile. The free interchangeability of different detachable microchannel devices on the acoustic tweezer platform was achieved by adding a waveguide layer (glass) and a coupling layer (polydimethylsiloxane (PDMS) polymer film). We designed and demonstrated the detachable multifunctional acoustic tweezer platform with three cell manipulation capabilities. In Demo I, the detachable acoustic tweezer platform is demonstrated to have the capability for parallel processing and enrichment of the sample. In Demo II, the detachable acoustic tweezer platform with capability for precise cell alignment is demonstrated. In Demo III, it was demonstrated that the detachable acoustic tweezer platform has the capability for the separation and purification of cells. Through experiments, our acoustic tweezer platform has good acoustic retention ability, reusability, and stability. More capabilities can be expanded in the future. It provides a simple, economical, and multifunctional reusable operating platform solution for biochemical analysis and detection systems.


Assuntos
Acústica , Polímeros , Vidro
5.
Biosensors (Basel) ; 12(6)2022 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-35735547

RESUMO

As a basis for biometric and chemical analysis, issues of how to dilute or concentrate substances such as particles or cells to specific concentrations have long been of interest to researchers. In this study, travelling surface acoustic wave (TSAW)-based devices with three frequencies (99.1, 48.8, 20.4 MHz) have been used to capture the suspended Polystyrene (PS) microspheres of various sizes (5, 20, 40 µm) in sessile droplets, which are controlled by acoustic field-induced fluid vortex (acoustic vortex) and aggregate into clusters or rings with particles. These phenomena can be explained by the interaction of three forces, which are drag force caused by ASF, ARF caused by Leaky-SAW and varying centrifugal force. Eventually, a novel approach of free transition between the particle ring and cluster was approached via modulating the acoustic amplitude of TSAW. By this method, multilayer particles agglomerate with 20 µm wrapped around 40 µm and 20 µm wrapped around 5 µm can be obtained, which provides the possibility to dilute or concentrate the particles to a specific concentration.


Assuntos
Microfluídica , Som , Acústica , Microesferas , Tamanho da Partícula , Poliestirenos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...