Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int Heart J ; 65(1): 155-158, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38296570

RESUMO

Unroofed coronary sinus syndrome is a rare congenital cardiac anomaly, involving some anatomical variations. Approximately 60% of patients with unroofed coronary sinus syndrome have a concomitant atrial septal defect, which is termed unroofed coronary sinus atrial septal defect (CSASD). The precise detection of these abnormalities has been usually difficult with conventional echocardiography, mostly due to its small and complex structures. Herein, we report a case with unroofed coronary sinus atrial septal defect, in which preoperative contrast-enhanced computed tomography (CT) was useful in the operative decision making. We successfully repaired the defective roof of the coronary sinus with a bovine patch, while eliminating the inter-atrial shunt. The patient's postoperative course was uneventful with no residual shunt.


Assuntos
Seio Coronário , Cardiopatias Congênitas , Comunicação Interatrial , Idoso , Humanos , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Seio Coronário/anormalidades , Ecocardiografia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/cirurgia , Síndrome , Tomografia Computadorizada por Raios X
2.
Artigo em Inglês | MEDLINE | ID: mdl-37289552

RESUMO

A 56-year-old man, suspected of having ST-segment elevation myocardial infarction due to spontaneous coronary artery dissection, underwent emergency percutaneous coronary intervention. Although he had moderate aortic regurgitation with aortic root dilation and mild heart failure, it was controlled with medications. Two weeks after discharge, he was readmitted with severe heart failure due to severe aortic regurgitation and underwent an aortic root replacement. Intraoperative findings revealed that localized dissection of the sinus of Valsalva involved the right coronary artery, resulting in coronary artery dissection. In cases of spontaneous coronary artery dissection, attention should be paid to coronary artery dissection caused by localized aortic root dissection.

3.
Gen Thorac Cardiovasc Surg ; 68(9): 938-942, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31894504

RESUMO

OBJECTIVES: Small-sized bioprosthetic valves are sometimes associated with suboptimal hemodynamic performance, leading to a patient-prosthesis mismatch. Trifecta pericardial valves are designed to improve hemodynamic performance. The purpose of this study was to investigate the hemodynamic properties of small-sized Trifecta valves and their efficacy in preventing a patient-prosthesis mismatch. METHODS: This was a retrospective analysis of 108 patients undergoing surgical aortic valve replacement with a Trifecta valve of 23 mm or less in a single Japanese institution. The hemodynamic performance was evaluated with an echocardiography examination in all patients after surgery, and the development of a patient-prosthesis mismatch was judged with the measured in vivo indexed effective orifice area. RESULTS: There was one early and seven late mortalities. There were no valve explants due to structural valve deterioration. Postoperative mean pressure gradients of 19-, 21-, and 23-mm valves were 15.1, 11.4, and 9.0 mmHg, respectively. The effective orifice area of 19-, 21-, and 23-mm valves was 1.41, 1.69, and 1.78 cm2, respectively. Patient-prosthesis mismatch occurred in 14 patients (1 severe and 13 moderate) and the incidence was 13.0% (15.4% in 19 mm, 18.0% in 21 mm, and 3.3% in 23 mm). CONCLUSIONS: The small-sized Trifecta valves showed excellent hemodynamic performance and were associated with a low incidence rate of patient-prosthesis mismatch.


Assuntos
Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Hemodinâmica , Complicações Pós-Operatórias/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Valvopatia Aórtica/cirurgia , Ecocardiografia , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Período Pós-Operatório , Desenho de Prótese , Estudos Retrospectivos
4.
Interact Cardiovasc Thorac Surg ; 28(6): 992-993, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30715369

RESUMO

In the surgical treatment of acute aortic dissection, the attachment of the dissected wall using surgical glue can be an effective procedure to stabilize the fragile dissected wall. A 42-year-old man underwent aortic root replacement for acute type A aortic dissection. However, after aortic declamping, he experienced severe myocardial impairment, which required an additional procedure of coronary artery bypass grafting. The unexpected myocardial ischaemia can be attributed to the inattentional use of surgical glue.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Circulação Coronária/fisiologia , Vasos Coronários/diagnóstico por imagem , Complicações Intraoperatórias , Isquemia Miocárdica/etiologia , Adesivos Teciduais/farmacologia , Adulto , Dissecção Aórtica/diagnóstico , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Ponte de Artéria Coronária , Vasos Coronários/cirurgia , Humanos , Masculino , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...